
1-Zone Expansion Module V2.0
(DGP2-ZX1)
panel Inst allation & Reference Manual) as well as through the
WinLoad Sec urit y Managem ent Softwar e (refe r to the WinLoad
Software Online Help for more informat ion).
Section [001] - Option [1]
Tamper Recognition
The DGP2-ZX1 com es equipped w ith an on-board tamper s witch.
When option [1] is enabled in sec tion [001] and the tamper s witch
is triggered, a Module Tamper report will be sent to the control
panel via the combus.
Instructions
DGP2ZX1-EI03
The 1-Zone Expansion Module (D GP2-ZX1) is an interface
between the DigiplexNE or Digiplex control panels and any
hardwired detection devices. The DGP2-ZX1 connects to the
DigiplexNE/Digiplex control panels’ combus providing you with one
additional hardwired input.
INSTALLATION
The DGP2-ZX1 modules are connected to the control panel’s
combus in a star and/or daisy chain configuration. The combus
consists of four wires t hat provide power and t wo-way
communication between the control panel and all modules
connected to it. Connect the four terminals labeled red, black,
green, and yellow of each DGP2-ZX1 t o the c orresponding
terminals on the control panel as shown in Figure 1 on the back of
this instruction. Please refer to the appropriate control panel’s
Installation & Reference Manual for maximum allowable installation
distance from the control panel.
ZONE CONN E CTIO NS
Each DGP2-Z X1 has one hardwired input terminal that will allow
you to connect up t o t wo (with AT Z enabled) non-bus det ection
devices to the DigiplexNE/Digiplex system. Each device connected
to the DGP2-ZX1’s input term inal m ust be ass igned to a zone in
the cont rol panel and the z one’s parameters mus t be def ined. For
more information, please refer to the appropriate control panel
Installation & Reference Manual. The DGP2-ZX1 will communicate
the st atus of t he z ones to the control panel through the com bus.
Connect the devices to the DGP2-ZX1 as shown in Figure 1 on the
back of this sheet.
The DGP2-ZX1 follows the ATZ and EOL definitions set
i n t he Digipl e x NE /Di giplex co nt rol pa ne ls .
PRO GRAMM ING M ET HO D
From any keypad connec ted to the combus:
STEP 1: Press and hold the [0] ke y
STEP 2: Enter the [
STEP 3: Enter section [953] (DGP-848) / [4003] (DGP-N E96)
STEP 4: Enter the DGP2-Z X1’s 8-digit [
STEP 5: Enter the 3-digit [
STEP 6: Enter the required data
INSTA LLER CODE]
SERIAL NUMBER]
SECTION] you want to program
INPUT SPEED TIMIN GS
The input s peed defines how quickly the input terminal on the
DGP2-ZX1 responds t o an open zone. The control panel will only
respond if the zone remains open for the duration of the Input
Speed. All other zone definitions and options don’t come into effect
until the control panel has responded. This feature prevents any
momentary glitches from causing an alarm or unnecessary
reporting.
Input Speed = Base Time x Time Value.
Section [002]
Base Time
This section determ ines the unit of tim e to be multiplied by t he
Time Value.
000 = 15 milliseconds
001 = 1 second
002 = 1 minute
Section [003]
Time Value
Enter a 3-digit decimal value bet ween 001 and 255. This decimal
value will be multiplied by the Base Time to determine the input
speed. For example, if section [002] = 001 and section [003] = 030,
the Input Speed will be 30 seconds.
SPECIFICATI ONS
On-board tamper s witch: Yes
Voltage: 9-16 VDC
Current consumption: 28mA maximum
Number of inputs : 1
Number of zones : 1 (2 w ith ATZ enabled) standard z one
Input speed: 15ms - 255 minutes
Power-up indication: Green LED illuminat ed
Proper operation: Red LED flashes
Locate indication: Green LED flashes
Combus failure
Indication: Green and red LEDs flash alternat ely
Locate deactivation: Press tamper s witch
H u mi d i ty: 95 % ma ximu m
Please note the following:
• The serial number is locat ed on the DGP2-ZX1’s PC board.
• We recommend that you use the DGP2-ZX1’s programming
sheet found in the DigiplexNE/Digiplex Modules’ Programming
Guide to keep track of what was programmed and how.
• This module can also be programmed using the control panel’s
Module Broadcas t Feature (refer to the appropriate control

Figure 1: Connecting the DGP2-ZX1
© 2001-2003 Paradox Security Systems Ltd.
DigiplexNE, D igiplex, GuardWall and WinLoad are trademarks or registered trademarks of Paradox Security Systems Ltd. or its af filiates in
Canada, t he United Stat es and/or other countries. All rights reserved.
PRINTED IN CANADA - 06/2003