1.0 BASIC OPERATION
The Esprit 616, 626, 636 and 646 keypads all
function in the same way, but display the visual
feedback differently.
1.1 VISUAL FEEDBACK
The numbers, symbols, lights and keys on the keypad
communicate the status of your system as described
below.
Figure 1: Overview of the 616 & 626 Keypads
![](/html/6c/6c89/6c89dc9c786b84074e12f5727705987c6aeb924462dad0f49332ae4cc437bfda/bg5.png)
Esprit Keypads 3
Figure 2: Overview of the 636 & 646 Keypads
![](/html/6c/6c89/6c89dc9c786b84074e12f5727705987c6aeb924462dad0f49332ae4cc437bfda/bg6.png)
4 User’s Manual
1.2 ZONES
The Esprit control panel can support up to 24 zones.
When a zone is opened or breached its
corresponding key will light up on the keypad. For
example, if zone 5 were to open, the 5 key will light up
on the keypad. The Esprit’s keypads will show the
status of the zones through keys 1 to 12. By default,
keys 1 to 12 will display the status of zones 1 to 12.
Press the [2ND] button and keys 1 to 12 will now
display the status of zones 13 to 24 respectively.
1.3 PARTITIONING
Your Esprit system is equipped with a partitioning
feature that can divide your alarm system into two
distinct areas (System A and System B). User access
codes can arm or disarm one system or both systems
simultaneously. In partitioning mode, when System A
is armed, the [STAY] key flashes. If System B is
armed, the [AWAY] key flashes. If both systems are
armed, both of these keys will be flashing.
2.0 ACCESS CODES
2.1 PROGRAMMING USER CODES
In addition to the master code, the Esprit control
panel can be programmed to accept up to 48 user
codes.
![](/html/6c/6c89/6c89dc9c786b84074e12f5727705987c6aeb924462dad0f49332ae4cc437bfda/bg7.png)
Esprit Keypads 5
Note: Avoid programming simple or
obvious access codes, such as your
telephone number, address or codes such
as 1234.
To create or modify access codes, follow the steps
indicated in section2.2. The master code and user
codes are identified by a 2 digit “code number”.
2.2 CREATING USER CODES
1) Press [ENTER] and then enter your master code
(default 474747) or user 1 code. You will hear
the “confirmation” beep and the [ENTER] key will
flash.
2) Enter the two digit “code number” (01-48) for the
user code you wish to program (or 00 to change
the master code). You will hear the
“confirmation” beep and the [ENTER] key will stay
on.
3) Key in 4 or 6-digit user access code and press
[ENTER]. The “confirmation” beep will be heard
again. The [ENTER] key will flash. You may
continue programming other user codes, or
press [CLEAR] to exit programming mode.
Note: [2ND] key flashes if location is empty
(no code programmed).
![](/html/6c/6c89/6c89dc9c786b84074e12f5727705987c6aeb924462dad0f49332ae4cc437bfda/bg8.png)
6 User’s Manual
2.3 DURESS CODES
The last user code (user 48) can be programmed to
report a “duress code”. If you are forced to arm or
disarm your system under threat, a duress code can
be entered to produce a silent alarm at the monitoring
station. Check with your installer to see if this option
is active on your system.
2.4 DELETING A USER CODE
3.0 ARMING & DISARMING
3.1 EXIT DELAY
After entering a valid arming sequence, an exit delay
timer will provide you with time to exit the protected
area before the system arms. The keypad may beep
during the exit delay.
How do I delete a user code?
1) Press the [ENTER] key.
2) Enter your [MASTER CODE] (default 474747).
3) Enter the 2-digit [CODE NUMBER] (01-48) to be deleted.
4) Press the [2ND] key.
5) Press the [ENTER] key.
6) If you wish to delete another user code, repeat steps 1
to 5. If you wish to exit, press the [CLEAR] key.
![](/html/6c/6c89/6c89dc9c786b84074e12f5727705987c6aeb924462dad0f49332ae4cc437bfda/bg9.png)
Esprit Keypads 7
3.2 REGULAR SYSTEM ARMING
3.3 STAY ARMING
Stay arming allows you to remain in the protected
area while “partially” arming the system (perimeter
zones only, such as doors and windows).
3.4 ONE TOUCH ARMING
One touch system arming - no code required. Check
with your installer if these features are enabled.
3.4.1 Key [10] - Regular Arming:
When the “ready” light is on, pressing key [10]
steadily for 2 seconds automatically arms the system.
How do I Regular Arm the system?
1) The green “READY’ light must be ON in order to arm
the system.
2) Enter your User Code.
After the Confirmation beep, the “ready” light and the
[STAY] and [AWAY] buttons will begin to flash. The exit
delay timer will begin the countdown to arming.
How do I Stay Arm the system?
1) Press the [STAY] button.
2) Enter your User Code.
After the Confirmation beep, the “ready” light and the
[STAY] and [AWAY] buttons will begin to flash. The exit
delay timer will begin the countdown to arming.