Paradox EVO48, EVO192, Digiplex EVO48, Digiplex EVO192, DGP2-648BL User Manual

EVO48
EVO192
User Guide
We hope this product performs to your complete satisfaction. Should you have any
questions or comments, please visit www.paradox.com and send us your comments.
Table of Contents
Introduction ....................................... 2
Basic Operation ................................. 3
Confidential Mode ..................................... ... ... ..4
MG-REM2 Feedback .......................... 5
Full/Force Arming Indicators .............................5
Stay/Sleep Arming Indicators .... ... ... ... .... ... ... ... ..5
Other Indicators ................................................5
Partitioned System ............................ 6
Area Display ......................................................6
Arming ................................................ 7
Exit Delay Timer ........... ... ... ...............................7
Regular Arming .................................................7
Stay Arming ......................................................7
Instant Arming ...................................................7
Force Arming ....................................................7
Bypass Programming ........................................7
Keyswitch Arming .............................................8
Auto-Arming ......................................................9
Disarming ......................................... 10
Entry Delay Timer ...........................................10
Disarming an Armed System ..........................10
Alarm Memory Display ....................................10
Access Codes .................................. 11
System Master Code (Default 123456) ...........11
Copy User Options ..........................................11
User Labels .................. ... ... ... .... ... ...................11
Deleting User Access Codes ..........................13
Programming User Access Codes ..................13
User Options ............................................. ... ...15
Access Control User Options ..........................15
How Access Control Works ............................18
Trouble Display ............................... 19
Trouble Display ...............................................19
Event Record Display .....................................20
Additional Features ......................... 21
Programmable Outputs (PGMs) .....................21
Keypad Settings ..............................................21
Modifying illumination settings on the DGP2-648BL LED 21
Setting Time & Date ........................................21
Programming Chime Zones ............................ 22
Panic Alarms ...................................................22
Quick Function Buttons ...................................22
VDMP3 Plug-In Voice Dialer ........... 23
Calling the VDMP3 (outside line) ....................23
Receiving a Call From the VDMP3 (alarm in system) 23
Testing and Maintenance ............... 25
Burglar Alarm Testing .....................................25
Fire Alarm Testing ...........................................25
System Maintenance ... ...................................25
System Test ....... ... ... .... ...................................25
Fire and Burglar Alarms ................. 26
Standard Fire Zone .........................................26
Delayed Fire Zone ..........................................26
Fire Safety Tips ...............................................26
Minimizing Home Fire Hazards .......................27
Home Fire Warning System ......... ... ... ... .... ... ...27
Burglar Alarm ..................................................27
Appendix 1: Hebrew Special Characters ........28
Appendix 2: Russian Special Characters ........29
Appendix 3: Greek Special Characters ...........30
Index ................................................. 31
Using Access Control ..................... 17
Entering & Exiting ...........................................17
Arming and Disarming with Card ................. ...17
1.0 Introduction
Your EVO System is an advanced technology security system that will provide you with reliable security protection and powerful features that are easy to use. The elegant and user-friendly keypads will allow you easy access to your security system's functions and information at the touch of a button.
Messages will be displayed differently depending on the keypad you have selected.The 32-character screen on LCD keypads will display messages and menus to guide you through the system’s operations. Your installer can even customize the messages on LCD keypads for your home or business.The LED display of the DGP2-648BL will let you assess the system status at a glance.
Since you will communicate your instructions to your system through the keypad, please read this manual carefully and have your installer explain basic system operation.
1.1 Legend
Indicates a warning or an important note.
Indicates useful information or a tip.
[
TEXT] Indicates information that must be entered on the keypad.
LCD
LED
Indicates an LCD Keypad instruction or information.
Indicates a DGP2-648BL instruction or information.
2 User Guide
2.0 Basic Operation
The LCD screen will guide you with detailed messages.
Use the arrow buttons to scroll through the current menu when the arrows appear in the LCD screen.
AC Light: ON = AC power OFF = Power failure
STATUS Light: When Green:
ON = All zones are closed. OFF = One or more zones are open. FLASH = Exit Delay in progress
When Red: ON = Area(s) armed OFF = Area(s) disarmed
The keypad will display the status
of all its assigned areas.
ACTION Lights: (Access, Stay, Force, Byp, Mem, Trbl and Prg) Lights will illuminate according to the status of the system.
Numerical Lights: (Zones) ON = Zone is open OFF = Zone is closed (OK) FLASHES = Zone / fire loop
AC Light:
ON = AC Power (OK) OFF = Power failure
AREA Lights: (A1, A2, A3 and A4) ON = Area armed OFF = Area disarmed FLASH = Area in alarm
STATUS Light: When green:
ON = All zones closed OFF = One or more zones are open FLASH = Exit Delay in progress
When red:
ON = Area(s) armed OFF = Area(s) disarmed FLASH = System in Alarm
For all keypads, the [ENTER] key will save and exit, and the [CLEAR] key will exit without saving.
[ENTER] and [CLEAR] represent the LCD/LED keypads’ enter and clear keys unless both keys are
shown to have a different function.
The following sections will introduce you to the functions of the buttons, lights, and messages on your keypad.
Figure 1: LCD Keypad Basic Overview
Figure 2: DGP2-648BL LED Keypad Overview
EVO Systems 3
LCD LED
2.1 Auditory Feedback (Beep Tones)
When you enter information on the keypad, the keypad will guide you with beep tones to communicate the acceptance or rejection of your entries.
Confirmation Beep: When an operation (i.e. arming/disarming) is successfully entered or when the system switches to a new status/mode, the keypad emits an intermittent beep tone (“
Rejection Beep: When the system reverts to a previous status, or when an operation is incorrectly entered, the keypad emits a continuous beep tone (“
BEEP-BEEP-BEEP-BEEP-BEEP”).
BEEEEEEEEEEP”).
LCD LED
2.2 Confidential Mode
Y our inst aller can program keypads to not display the status of your system a utomatically by changing the keypad to Confidential Mode.
In Confidential Mode:
The zones and status messages will NOT be displayed
The indicator lights will NOT illuminate
Depending on how your keypad was programmed by your installer, you must either press a button or enter your user access code to illuminate the indicator lights and activate Normal Mode.
4 User Guide
3.0 MG-REM2 Feedback
If your system includes the Wireless Zone Expansion module (MG-RTX3), it will be able to support the Two-Way Remote Control (MG-REM2). This remote allows you to change the status of the system, and it also provides visual and auditory feedback.
3.1 Full/Force Arming Indicators
Action LED Sequence Auditory Sequence
Disarming Green on Two beeps
Exit delay Red / green slow flash Confirmation beep
Arming / Entry Delay Red on Confirmation beep
Alarm Red fast flash Alarm beep
3.2 Stay/Sleep Arming Indicators
Action LED Sequence Auditory Sequence
Disarming Green on Two beeps
Exit delay Yellow / green slow flash Confirmation beep
Arming / Entry Delay Yellow on Confirmation beep
Alarm Red fast flash Alarm beep
3.3 Other Indicators
Action LED Sequence Auditory Sequence
PGM on/off Yellow on Confirmation beep
EVO Systems 5
4.0 Partitioned System
Your installer can set your keypad to recognize separate protected areas. A separated system is called a partitioned system, which can be useful in situations where shared security systems are more practical. For example, a company that has both an office and a warehouse area, can arm and disarm each area separately while controlling access to each area. Therefore, one person may have access to only one area, whereas another person may have access to all areas. Access to the areas is determined by the User Access Code.
4.1 Area Display
The Area Status Display enables you to see the status of the individual areas within a partitioned system. Your installer can partition the system into separate areas.
To view the status of the areas:
1. Enter your
2. Press the button corresponding to the area (i.e. 1, 2,...8), or use the [S] and [T] buttons and press
3. Press
[ACCESS CODE], and then press the [1] button.
[ENTER] when the area you want to view appears on the screen.
[CLEAR] to exit.
LCD
LED
In Area Status Display mode, the following information will scroll on the LCD screen:
ready: if all zones in the selected area are closed.
not ready: if zones in the selected area are open.
Front Door Open: if there is an open zone within that area.
Trouble(s): (section 9.0 on page 19) if a trouble has occurred.
Alarms in Memory: (section 6.3 on page 10) if an alarm has occurred.
Armed; Force Armed; Instant Armed; Stay Armed: displays the arming status of the selected area.
In Area Status Display, the following will illuminate for the area selected:
The area lights (A1, A2, A3, and A4) if the associated area is armed. For example, if you have selected area 3 and it is currently armed, A3 will illuminate.
The numerical light(s) representing any open zone(s) in a corresponding area or areas.
•The M
•The T
•The S
•The F
•The B
EM action light if any alarms have occurred.
RBL action light if any troubles are occurring.
TAY action light if the area is Stay or Instant Armed. ORCE action light if the area is Force Armed. YP action light if zones are bypassed.
6 User Guide
5.0 Arming
When your system is armed, it can respond to any breach in the protected zones by causing an alarm and sending a report to your monitoring station.
LCD LED
LCD LED
LCD LED
LCD LED
5.1 Exit Delay Timer
When you arm your system, it will trigger the Exit Delay Timer to provide you with enough time to exit the protected area before the system is armed.
5.2 Regular Arming
This method is used for the everyday arming of your system. All zones within the protected area must be closed to Regular arm the system.
To Regular arm the system:
1. Enter your [
2. Press the [
3. If you have access to more than one area, select the area(s) you wish to Regular arm (refer to section 4.1 on page 6).
ACCESS CODE].
ARM] button.
5.3 Stay Arming
Stay arming will partially arm your system to permit you to remain in your home or office by arming the outer zones (perimeter) of the protected area (i.e. doors and windows).
To Stay arm:
1. Enter your [
2. Press the [
3. If you have access to more than one area, select the area(s) you wish to Stay arm (refer to section 4.1 on page 6).
ACCESS CODE].
STAY] button.
5.4 Instant Arming
This feature is the same as Stay arming except that there is no Entry Delay. Therefore, any armed zone that is breached will immediately generate an alarm.
LCD LED
LCD LED
To Instant arm:
1. Enter your [
2. Press the [5] button.
3. If you have access to more than one area, select the area(s) you wish to Instant arm (refer to section 4.1 on page 6).
ACCESS CODE].
5.5 Force Arming
Force arming allows you to quickly arm your system when zones are open. However, once the open zone is closed, your system will then arm that zone as well.
To Force arm:
1. Enter your [
2. Press the [
3. If you have access to more than one area, select the area(s) you wish to Force arm (refer to section 4.1 on page 6).
ACCESS CODE].
FORCE] button.
5.6 Bypass Programming
You can bypass certain zones when you arm the protected area(s). When a zone is bypassed, it will be ignored the next time your system is armed. Once your area is disarmed, the system will unbypass the zone.
To Bypass a zone:
1. Enter your [
2. Press the [
ACCESS CODE].
BYP] button.
EVO Systems 7
3. Enter the zone number (i.e. 01, 02,...96), or use the [S] and [T] buttons and press
BYP] once the zone you want to bypass appears on the screen. If bypassed, the byp
[
light does not appear on the screen and the keypad emits a rejection beep, you may not have access to bypass that zone.
4. Repeat step 3 until all zones you want to bypass have been selected.
5. Press the [
ENTER] button to save and exit.
To view all bypassed zones.
1. Enter your [
2. Press the [
ACCESS CODE].
BYP] button.
3. Scroll through the zones using the [S] and [T] buttons to view zone status. (LCD Keypads)
In order to bypass a zone, the following conditions must be met:
• The zone must have the Bypass option programmed by your installer.
• The Bypass option must be enabled in your User Options.
• Your user access code must have access to the zone’s Area Assignment.
• The zone’s area must be disarmed before the zone can be bypassed.
Fire Zones cannot be bypassed.
5.6.1 Bypass Recall
Bypass Recall reinstates the zones that were bypassed the last time your system was armed.
LCD LED
To activate Bypass Recall:
1. Enter your [
2. Press the [
3. Press the
ACCESS CODE].
BYP] button.
[MEM] button.
Zones bypassed the last time your system was armed are bypassed.
4. Press the [
ENTER] button to save and exit.
5.6.2 One-Touch Buttons
If enabled by your installer, you can access the following features without using your user access code by pressing and holding the desired One-Touch button.
Table 1: One Touch Button
Button Feature
[ARM] Regular arm
[
STAY] Stay arm
[
FORCE] Force arm
[
BYP] Bypass Programming
[
DISARM] Disarm a Stay/Instant armed area
[5] Instant arm [6] Change display settings [7] View Event Record display (LCD Keypads only)
LCD LED
5.7 Keyswitch Arming
A key can be used to arm and disarm your system using two forms of keyswitches. With a Maintained Keyswitch, place the key in the “ON” position to arm your system, and place the key in the “OFF” position to disarm your system. With a Momentary Keyswitch, place the key in the “ON” position briefly then place it back in the “OFF” position to arm the system. Repeat this process to disarm with a Momentary Keyswitch.
8 User Guide
LCD LED
5.8 Auto-Arming
If enabled by your installer, you can set the time that an area will arm itself automatically.
5.8.1 Timed Auto-Arming
Y our installer can set T imed Auto-Arming to function in either Force or S tay arming mode. A sixty-second (default value) Exit Delay sequence will begin prior to your system automatically arming itself at the programmed time.
To set the Auto-Arming timer:
1. Enter your [
ACCESS CODE].
2. Press the [0] button.
3. Press the [
4. If you have access to more than one area, press the area’s
[S] and [T] buttons and press the [
MEM] button.
number , or use the
ACC] button when the area you want to
program appears on the screen.
5. Enter the time you want the area to be armed according to the 24-hour clock (i.e. 9 a.m. is 09:00 and 9 p.m. is 21:00).
6. Press the [
ENTER] button to save and exit.
If you are using the DGP2-648BL LED keypad, The flash if a time is not already programmed. The
MEM action light will
PRG action light, the area
light of the chosen area, and the first number of the previous time set will illuminate (
10 light = zero).
5.8.2 No Movement Auto-Arming
Your system can be programmed to send a report to your monitoring station and/ or arm the system if there is no activity in the area during a specified period of time. Your installer can set No Movement Auto-Arming to function in either Regular or Stay arming mode.
EVO Systems 9
6.0 Disarming
When your system is disarmed, it deactivates any alarms in progress, and it deactivates the zones so the alarm will not be triggered if zones are breached.
LCD LED
LCD LED
6.1 Entry Delay Timer
Y our installer will program designated entry points (i.e. the front door) with an Entry Delay Timer. This delay gives you time to enter the armed premises and enter your code to disarm your system before the alarm is triggered.
6.2 Disarming an Armed System
You can only disarm an area to which your user access code is assigned. User access codes with the “Arm Only” (section 7.6 on page 15) option enabled cannot disarm an armed system.
How do I disarm the system?
1. Enter your [
2. Press the [ area(s) you wish to disarm (refer to section 6.2 on page 10).
To disarm a system in alarm:
1. Enter your [
2. In the case of a false alarm, call your monitoring station quickly to advise them of the false alarm.
In the case of a burglar alarm, leave the premises and call the Police from a safe location.
ACCESS CODE].
DISARM] button. If you have access to more than one area, select the
ACCESS CODE].
6.3 Alarm Memory Display
When an alarm occurs in a zone:
The area and zone (i.e. Alarm Area 1 - Front Door) are displayed / zone’s LED flashes even when the system is armed. The notification continues until disarming, even if the zone is restored. (EVO641 / EVO641R only)
The alarm memory will be erased after the next alarm occurs and a valid code has been entered.
LCD
LED
10 User Guide
To view the alarms that occurred the last time the system was armed:
1. When the system is disarmed, the LCD keypad’s screen will display Alarm in Memory: Press [mem]. The DGP2-648BL LED’s MEM action light will illuminate.
2. Press the [
Each zone that was breached while armed will appear below Alarm in:.
MEM action light will flash and the numerical light(s) for each zone whose alarm
The was triggered will illuminate.
3. Press the [
MEM] button.
CLEAR] button to exit the Alarm Memory Display.
7.0 Access Codes
Access Codes allow access to the system. Your system supports up to 999 user access codes. Codes are given a User Number between 002 and 999 (User Number 001 is the System Master Code). Your installer will program user access codes to be four, six, or variables of one to six digits in length. Each digit can be any value between zero and nine. If your installer programmed your system to accept a variable code length, you have to press the [ access code.
ENTER] button after entering your user
LCD LED
LCD
7.1 System Master Code (Default 123456)
The System Master Code will give you access to all the features available on your system, as well as the ability to add, modify, or delete any user acc ess codes. We suggest that you change this code to prevent others from accessing and changing options without authorization. Y our inst aller can set the System Master Code to be either 4 or 6 digits in length.
To change the System Master Code:
1. Enter the current [S
YSTEM MASTER CODE] (default: 123456).
2. Press the [0] button.
3. Press the [
ACC] button.
4. Enter the numbers [0] [0] and [1].
5. Enter a [
6. Press the [
NEW CODE].
ENTER] button to save and exit.
The System Master Code has access to all Access Control doors and all Access Control features at all times. Only the card’s serial number and the choice of arming method can be changed. If the other options are manually changed, the System Master Code will immediately revert to its original programming.
You can assign a label (name) to a user access code at any point during the “Programming User Access Code” process. Refer to section 7.3 on page 11 to assign a User Label.
7.2 Copy User Options
This feature allows you to copy the User Options, Access Control Options, and Area Assignments from one user access code to another. All User Options are copied except the User Code, Card Assignment, and User Label.
LCD
To copy user options:
1. Enter your [
ACCESS CODE] (System Master Code or user access code with Master
feature).
2. Press the [0] button, and then the [
ACC] button.
3. Enter the 3-digit User number you wish to copy TO.
4. Press the [
MEM] button.
5. Enter the 3-digit User number you wish to copy FROM.
6. Enter a user code. If the user code is of variable length, press the [
ENTER] button after
entering the user code. If necessary, assign an Access card (step 13 in section 7.5.1 on page 14) and User Label (section 7.3 on page 11).
7. Press [
ENTER] to save and exit.
7.3 User Labels
User labels personalize user access codes and can be assigned by pressing [ENTER] at any point after step 4 during the programming of user access codes (refer to section
7.5.1 on page 14). For Example, LCD keypads can display John Smith Select Action. To program a user label:
1. At any point after step 4 in section 7.5.1 on page 14:
2. Press the [
ENTER] button.
3. Type the desired characters as detailed in section 7.3.1 on page 12 and section 7.3.2 on page 12.
EVO Systems 11
4. Press the [S] button to move the cursor to a new space.
5. Repeat steps 2 and 3 until the desired label is complete.
6. Press the [
ENTER] button to save and exit.
7.3.1 Keypad Buttons
Every numeric button on the LCD keypads is assigned a set of letters. To obtain the desired letter using the numeric buttons on your keypad, press the button until the desired letter appears on the screen. For example, if you wanted to enter the letter “C” you would press the [1] button three times (refer to Table 2 on page 12). If using a Hebrew keypad, refer to Table 6 in Appendix 1: Hebrew Special Characters on page 28. If using a Russian keypad, refer to Table 8 in Appendix 2: Russian Special Characters on page 29. If using a Greek keypad, refer to Table 10 in Appendix 3: Greek Special Characters on page 30.
Table 2: Keypad Letter Assignments
Key
Press Key
Once
Press Key
Twice
Press Key
Three Times
[1] A B C [2] D E F [3] G H I [4] J K L [5] M N O [6] P Q R [7] S T U [8] V W X [9] Y Z
7.3.2 Special Function Keys
[STAY] = Insert Space Pressing the [
FORCE] = Delete
[ Pressing the [
STAY] key inserts a blank space in the current cursor position.
FORCE] key will delete the character or blank space found at the
current cursor position.
ARM] = Delete Until the End
[ Pressing the [
ARM] key will delete all characters and spaces to the right of the
cursor and at the cursor's position.
DISARM] = Numeric Keys / Alphanumeric Keys
[ Every time the [
DISARM] key is pressed it will toggle from numeric keys to
alphanumeric keys and vice versa. Numeric: Keys [0] to [9] represent numbers 0 to 9.
BYP] = Lower Case / Upper Case
[
Every time the [BYP] key is pressed it will toggle the case setting from lower to upper case and vice versa.
[
MEM] = Special Characters
After pressing the [
MEM] key, the cursor will turn into a flashing black square.
Using Table 3 on page 13, enter the 3-digit number that represents the desired symbol. If using a Hebrew keypad, see Hebrew Special Characters Catalogue on page 28. If using a Russian keypad, see Russian Special Characters Catalogue on page 29. If using a Greek keypad, see Greek Special Characters Catalogue on page 30
12 User Guide
Table 3: Special Characters Catalogue
032 048 064 080 096 112 128 144 160 176 192 208 224 240
033 049 065 081 097 113 129 145 161 177 193 209 225 241
034 050 066 082 098 114 130 146 162 178 194 210 226 242
035 051 067 083 099 115 131 147 163 179 195 211 227 243
036 052 068 084 100 116 132 148 164 180 196 212 228 244
037 053 A069 085 101 117 133 149 165 181 197 213 229 245
038 054 070 086 102 118 134 150 166 182 198 214 230 246
039 055 071 087 103 119 135 151 167 183 199 215 231 247
040 056 072 088 104 120 136 152 168 184 200 216 232 248
041 057 073 089 105 121 137 153 169 185 201 217 233 249
042 058 074 090 106 122 138 154 170 186 202 218 234 250
043 059 075 091 107 123 139 155 171 187 203 219 235 251
044 060 076 092 108 124 140 156 172 188 204 220 236 252
045 061 077 093 109 125 141 157 173 189 205 221 237 253
LCD LED
LCD LED
046 062 078 094 110 126 142 158 174 190 206 222 238 254
047 063 079 095 111 127 143 159 175 191 207 223 239 255
Polish
Hungarian
Turkish
001 002 003 004 005 006 007
001 002 003
001
7.4 Deleting User Access Codes
To delete user access codes, follow steps 1 to 4 in section 7.5.1 on page 14, but press the [CLEAR] button in Step 4. Once the information is erased, press the [ENTER] button to save and exit.
7.5 Programming User Access Codes
The System Master and Users with the Master feature can program user access codes with User Options and Area Assignments. The section 7.5.1 on page 14 describes the steps you would follow to program user access codes. If you wish to program user access codes using the NEware Software, please contact your installer for information.
If the keypad emits a rejection beep at any point during the programming procedure, you may have chosen an existing user code or you do not have access to certain User Options (section 7.6) and Area Assignments (step 7 in section 7.5.1 on page 14). Users with the Master feature can only assign User Options and Area Assignments that they are assigned to. For example, if a User with the Master feature is assigned User Option 1 and Area 2, they can only assign Option 1 and Area 2 to a user access code.
EVO Systems 13
LCD LED
Note:
- For a detailed description of the Acce ss Contro l
NOTE: If no area is assigned, and if PGMs are programmed by your installer, the user can only control the PGMs. Refer to section 10.1 on page 21 for a more detailed explanation of PGMs.
User Options, see section 7.7 on page
User Labels on page 11.
Notes:
- For a detailed description of the User Options, see section 7.6 on page 15.
- By default, all users can regular arm the system.
7.5.1 Programming User Settings
14 User Guide
LCD LED
7.6 User Options
Options [1] and [2]: Master Feature
When option When option access codes (P.I.N. only) and User Labels.
[1] is OFF, the User cannot program other users into the system. [1] is ON and option [2] is OFF, the user can program and modify user
When both options create or modify user access codes, User Options, User Access Control Options, Access Card Numbers, User Labels and Area Assignments according to their own programming. For example, if the Full Master User has access to area #1 and option the Full Master user can only assign area #1 and option
Option [3]: Duress When option someone forces a user to arm or disarm an area(s). By entering a user access code (P.I.N.) reserved for the Duress feature, the system will arm or disarm the area(s), and then send a silent alarm to the monitoring station.
Option [4]: Bypass When option deactivate zones when arming the area(s).
Option [5]: Arm Only When option areas with either a card or code, but cannot disarm. When the option is OFF, the user can either arm or disarm assigned areas.
Option [6]: Stay & Instant Arm When option Stay or Instant arm their assigned areas.
Option [7]: Force Arm When option their assigned areas.
[1] and [2] are ON, the user has Full Master rights. The user can
[4] (Bypass) only,
[4] to other users in the system.
[3] is ON, the Duress feature is enabled. This feature is used when
[4] is ON, the Bypass feature is enabled. This feature allows the user to
[5] is ON, the Arm Only feature is enabled. The user can arm assigned
[6] is ON, the Stay and Instant arm features are enabled. The user can now
[7] is ON, the Force arm feature is enabled. The user can now Force arm
LCD
Option [8]: Area Access
When option user access code. When option areas it controls. For example, the keypad is assigned area 1 only, and your user access code is assigned areas 1 to 8. If the option is ON, you can access all eight areas from the keypad. If the option is OFF, you can only access area 1.
[8] is ON, the keypad will permit access to all the areas assigned to the
[8] is OFF, the keypad will only permit access to the
By default all users can Regular arm the system.
7.7 Access Control User Options
Option [1]: Access Control
When option Control is enabled in the system. A user that is not assigned to any partition, but has the Access Control option (Option [1]) enabled, can now gain access to an access control door by entering a code # (P.I.N.) and then pressing the option is OFF, the user cannot access an Access Control door.
Option [2]: Can Disarm with Access Card When option Access Control door. When option
17.
[1] is ON, the user can gain access to an access control door when Access
[ACC] keypad key. When the
[2] is ON, a User’s Access Control card can unlock and disarm an armed
[2] is OFF, follow the settings in option [8] on page
For option User Options must be disabled (refer to section 7.6 on page 15).
[2] to function in the ON position, option [5] “Arm Only” in the
EVO Systems 15
Option [3]: Card with Extended Unlocked Period
When option [3] is ON, “Extended Unlocked Period” is enabled. “Extended Unlocked Period” refers to the time period programmed into each Access Control door by your installer that extends the unlocked time of the door. For example, if your installer sets the Unlocked period of the door to 30 seconds and the Extended Unlocked Period to 15 seconds, a user access code with “Extended Unlocked Period” enabled will have a total of 45 seconds to pass through the door.
Options [4] and [5]: Arming with Card Options (refer to section 8.2.1 on page 17). You can either Regular arm, Stay arm, Force arm, or Disable the Arming with Card feature.
[4] and [5] define the type of arming when arming with an Access Control card
[4] ON, [5] OFF = Regular Arm [4] OFF, [5] ON = Stay Arm [4] and [5] ON = Force Arm [4] and [5] OFF = Disable the Arming with Card feature
Option [6]: Add Tolerance Window to Schedule
When option extends a user’s scheduled access period through an Access Control door by the amount programmed by your installer. For example, if the user’s assigned schedule for the door is Monday to Friday from 9:00 a.m. to 5:00 p.m., and your installer sets the “Tolerance Window” at one hour, the user with the “Schedule Tolerance Window” enabled will be able to enter and exit one hour before and after their scheduled time for that door.
[6] is ON, the Schedule Tolerance Window feature is enabled. This feature
Option [7]: Code Follows Schedule
When option hours assigned in step 8 in section 7.5.1 on page 14. When the option is OFF, users can use their access codes at any time.
Option [8]: Card to Unlock and Code to Disarm Option user can use an Access Control card to unlock an armed Access Control door, however the user must enter a user access code to disarm the armed area. When option OFF, a user can gain access to an Access Control door only if the door’s area(s) is already disarmed.
[7] is ON, users can use their access codes only during their scheduled
[8] functions only if option [2] in section 7.7 is OFF. When option [8] is ON, a
[8] is
For option [8] to function in the ON position, option [5] “Arm Only” in the User Options must be disabled (refer to section 7.6 on page 15).
16 User Guide
8.0 Using Access Control
LCD LED
8.1 Entering & Exiting
Depending on how your system is installed and on the type of keypad, there are various ways to enter and exit Access Control doors:
Present your Access Control card to the reader or the EVO641R or DGP2-641RB keypad. The system will verify that the card is allowed access according to its assigned Access Level and Schedule. If it is accepted, the system will unlock the door. The reader’s light can be programmed by the installer to turn green or extinguish briefly to indicate that the door can be opened.
When the motion detector detects movement (Request for Exit), it will unlock the door to permit passage from inside.
Enter your user access code on the keypad and press
[ACC].
If the Access Control door is on a “Door Unlocked Schedule”, you may be able to open Access Control doors without using a user access code or an Access Control card. Depending on the door’s programming, the door can remain unlocked during the entire programmed schedule or the door can unlock once a valid Access Control card is presented to the reader during the schedule and then will remain unlocked for the remainder of the schedule.
EVO641R /
LCD
DGP2-641RB only
EVO641R /
LCD
DGP2-641RB only
8.2 Arming and Disarming with Card
8.2.1 Arming with Card
presented to a door during its assigned Schedule (refer to step 8 in section
7.5.1 on page 14).
presented to a door within its assigned Access Level (refer to step 8 in section
7.5.1 on page 14).
programmed to allow arming (options
assigned to all areas that are assigned to the Access Control door (refer to step 7 in section 7.5.1 on page 14), or assigned to at least one of the areas assigned to the Access Control door depending on how your installer has programmed the Access Control door.
8.2.2 Disarming with Card
To disarm and unlock an Access Control door when the area assigned to it is armed, present your Access Control card to the reader or EVO641R / DGP2­641RB keypad (door). The Access Control card must be:
presented to a door during its assigned Schedule (refer to step 8 in section
7.5.1 on page 14).
presented to a door within its assigned Access Level (refer to step 8 in section
7.5.1 on page 14).
programmed to allow disarming (option [2] in section 7.7 on page 15).
assigned to all areas that are assigned to the Access Control door (refer to step 7 in section 7.5.1 on page 14), or assigned to at least one of the areas assigned to the Access Control door depending on how your installer has programmed the Access Control door.
[4] and [5] in section 7.7 on page 15).
EVO Systems 17
LCD LED
8.3 How Access Control Works
To illustrate how Access Control functions, we will use three simple Access Control System examples:
Figure 3: Example A
Bonnie’s Access Control card is programmed with Access Level 01 and Schedule 01. If she presents her card to the reader or the EVO641R / DGP2-641RB keypad on Door 02 on Tuesday, August 3 at 3:00 p.m., she will gain access to the room.
Figure 4: Example B
If Bonnie presents her card to the reader or the EVO641R / DGP2-641RB keypad on Door 02 on Saturday or on a Holiday at 3:00 p.m., she will be denied access.
Figure 5: Example C
If we change Bonnie’s Access Level to 02 and she presents her card to the reader or the EVO641R / DGP2-641RB keypad on Door 02 on T uesday, August 3 at 3:00 p.m., she will be denied access.
18 User Guide
9.0 Trouble Display
LCD LED
LCD
LED
9.1 Trouble Display
If your system experiences any problems, Trouble(s) [TRBL] to View will appear on the screen, or the troubles that occur in the area(s) to which the keypad has been assigned. Potential troubles have been sorted into eight groups. Only the troubles which are relevant to you are listed and described below. If a trouble that is not described or listed below appears, contact your installer. To view the Trouble Display:
1. Press the [
The Group Heading with the trouble will appear on the screen. Press the [S] and [T] buttons to scroll between the Groups experiencing a trouble.
On the DGP2-648BL LED keypad, The light(s) representing group heading number(s) will illuminate.
2. Press the [
TRBL action light will illuminate. The Trouble Display will only display the
TRBL] button.
TRBL action light will flash and the numerical
NUMBER] of the Trouble you wish to view.
We strongly suggest that if any troubles occur, contact your installer immediately to have your system serviced.
9.1.1 Group 1: System
[1] AC Failure
The control panel has detected a power failure. This means that your system is running on the backup battery. If this trouble occurs when your establishment is not experiencing a power failure, call your installer for repairs.
[2] Battery Trouble
The backup battery is disconnected, needs to be recharged, or replaced.
[5] Bell Absent
The system has detected that the bell or siren is not connected.
9.1.2 Group 2: Communicator
[1] TLM1
The control panel is unable to access the main telephone line.
[2] to [5] Fail to Communicate (1 to 4)
The control panel tried all assigned telephone numbers and failed to contact the monitoring station.
[6] Fail to Communicate PC
The control panel is unable to communicate with the WinLoad software.
9.1.3 Group 5: Zone Tamper
The zone(s) that was tampered with will be displayed on the LCD screen.
9.1.4 Group 6: Zone Low Battery
If a wireless device's battery needs to be replaced, the zone that is assigned to the device will be displayed on the LCD screen.
9.1.5 Group 7: Zone Fault
A wireless device is no longer communicating with its receiver, or a connection or CleanMe
TM
trouble is occurring with your smoke detectors.
EVO Systems 19
9.1.6 Group 8: Clock Loss
The time and date have been reset to the default. This is the only trouble that we recommend that you correct. Clock Loss [8] to Set will appear on the LCD screen after you press the [
TRBL] button or the [] key. Refer to section 10.4 on page 21
to set the time and date.
LCD
9.2 Event Record Display
The Event Record Display will record the user-initiated actions that occurred in your system as well as any alarms or troubles (i.e. “Access Granted”). You will only be able to view the events that occurred in the area(s) assigned to your user access code.
-Only available on LCD keypads. To view the Event Record:
1. Enter your [
2. Press the [7] button.
3. If you have access to more than one area, select the area(s) you wish to view.
4. Use the [S] and [T] buttons to scroll between the events.
5. Press the [ Once you have entered Event Record Display mode, you can change the order that the
Event Record screens appear by pressing the [7] button. If you already know the number of the event you want to view, press the [ the event's number.
ACCESS CODE].
CLEAR] button to exit.
MEM] button after step 3 above, and then enter
20 User Guide
10.0 Additional Features
*This feature cannot be accessed via One-Touch Buttons (see section 5.6.2 on page 8).
When keypad mute is enabled, only confirmation, rejection, and key-press beeps are audible.
EVO641 / EVO641R only
LCD LED
LCD
10.1 Programmable Outputs (PGMs)
Your system includes Programmable Outputs (PGMs) that can be programmed by your installer. A PGM triggers when a predetermined event or series of events occurs in your system. The PGMs can be programmed to reset smoke alarms, turn on light switches, open or close garage doors and much more. Ask your installer about this useful feature.
10.2 Keypad Settings
You can modify the keypad settings to suit your needs.
1. Scrolling Speed refers to the amount of time that a message will remain on the screen before moving to the next message.
2. Backlight refers to the illumination behind the buttons and LCD screen.
3. Contrast refers to how dark or pale characters will appear on the screen.
Figure 6: Modifying LCD screen settings on LCD Keypads
LED
10.3 Modifying illumination settings on the DGP2-648BL LED
To modify illumination settings:
1. Enter your
[ACCESS CODE]. Your keypad will emit a Confirmation Beep. The ACCESS
action light will flash.
2. Press the [6] key. Your keypad will emit a Confirmation Beep, the Prg action light will illuminate and the numerical light for the current setting will illuminate.
T
3. Use the [S] and [
] keys to increase or decrease the illumination. The range is
between numerical light 1 to 8 (1 being the lowest and 8, the brightest).
[ENTER] key to save and exit.
ACCESS CODE] and press the [TRBL] button.
LCD
4. Press the
10.4 Setting Time & Date
To reset the time and date:
1. Enter your [
2. Press the [8] button.
3. To change the time, place the cursor under the number you want to change by using the [S] button and enter the time according to a 24-hour clock (i.e. 9 a.m. is 09:00 and 9 p.m. is 21:00).
4. To change the date, place the cursor under the number you want to change and enter the correct date according to year/month/day.
5. Press the [
ENTER] button to save and exit.
EVO Systems 21
LED
On the DGP2-648BL LED keypad, follow this procedure:
1. Enter your [
ACCESS CODE] and press the [TRBL] button.
2. Press the [8] button.
3. Enter the hour and minutes according to the 24-hour clock (i.e. 9AM is 09:00 and 9PM is 21:00).
4. Enter the correct date according to yyyy/mm/dd.
5. Press
[CLEAR].
LCD LED
LCD LED
10.5 Programming Chime Zones
Y ou can program the keyp ad to emit a rapid, intermittent beep tone when ever designated zones are opened or only when opened between certain hours. These zones are referred to as Chime Zones. Your installer can also program your Chime zones to beep upon closure.
How do I program chime zones?
1. Enter your [
ACCESS CODE].
2. Press the [9] key.
3. Press the [1] key to chime a zone. Enter the number corresponding to the zone to be
[S]
and
[T]
chimed, or use the
buttons to scroll the list of zones. Press the button to chime or unchime the zone that appears on the screen. Press save.
OR
Press the [2] button to set the time period a chimed zone will beep. Enter the time that the chimed zone(s) will start beeping when opened (HH:MM). Enter the time that the chimed zone(s) will stop beeping when opened (HH:MM).
[
CLEAR
]
4. Press
to exit chime programming.
10.6 Panic Alarms
Your system can be programmed to send an alarm to your monitoring station to request help from the police, a medical facility , the fire department, or anyo ne you wish when you press a predetermined combination of buttons. To generate a panic alarm, simultaneously press and hold the button combinations displayed in Table 4 on page 22. Your installer can program the alarm to be either silent or audible.
[
ENTER
[ACC]
]
to
LCD LED
Table 4: Panic Buttons
Panic Alarm Types
Buttons to be pressed and held
simultaneously
Emergency Panic Press & hold the [1] and [3] buttons Auxiliary Panic Press & hold the [4] and [6] buttons Fire Panic Press & hold the [7] and [9] buttons
10.7 Quick Function Buttons
You will only need to use the Quick Function Buttons upon your installer ’s or monitoring station's request. Only the System Master Code or user access codes with the Master feature enabled will be able to access these functions.
To access the Quick Function Buttons:
1. Enter your [
2. Press the [0] button.
3. Press the:
STAY] to send a test report to the monitoring station.
[
FORCE] to call the WinLoad software.
[
ARM] to answer the WinLoad software.
[ [
DISARM] to cancel communication with the WinLoad software.
ACCESS CODE]
22 User Guide
11.0 VDMP3 Plug-In Voice Dialer
The VDMP3 is a voice-assisted module that can be programmed to call up to 8 telephone numbers in the event of an alarm. You can also call the VDMP3 from an outside line, enabling you to arm or disarm the system as well as activate up to 8 PGMs.
11.1 Calling the VDMP3 (outside line)
Connected to an answering machine:
1. From an outside line, dial the telephone number to which the VDMP3 is connected.
2. When the line rings, hang up the telephone.
3. Dial the telephone number again within the time limit set by your installer.
4. When the VDMP3 answers the line, you are prompted to enter your access code.
5. Options are given to arm/disarm (1) and control features (PGMs) (2).
Not connected to an answering machine:
1. From an outside line, dial the telephone number to which the VDMP3 is connected.
2. When the VDMP3 answers the line, you are prompted to enter your access code.
3. Options are given to arm/disarm (1) and control features (PGMs) (2).
11.2 Receiving a Call From the VDMP3 (alarm in syste m)
When the VDMP3 calls because of an alarm in the system, the option is given to disarm the system or disconnect (##). If you hang up without disarming or disconnecting, the VDMP3 calls the next telephone number on its list (see Telephone Numbers in VDMP3 Setup Instructions).
EVO Systems 23
24 User Guide
12.0 Testing and Maintenance
12.1 Burglar Alarm Testing
Two people are needed to complete this test. One person will watch the screen on the keypad while the other person walks around the protected areas and opens the zones (i.e. opens the doors and windows that are protected, walk in the path of the motion detectors, etc.). The screen will display the opened zones, but if a zone does not register, contact your installer.
12.2 Fire Alarm Testing
Do NOT use an open flame or burning materials to test your fire detection devices. Your installer will provide details on the best way to test your system.
12.3 System Maintenance
Under normal use your system requires no maintenance other than regular testing. We recommend that your installer change the battery every three years.
LCD LED
12.4 System Test
Speak to your installer before conducting a System Test since the system must be programmed to respond to the test instructions. It is normally recommended that you conduct the system test once a week, but contact your installer for instructions concerning your particular system.
To conduct the system test:
1. Call your monitoring station to advise them that you are testing your system.
2. Enter your [
3. Press the [8] button.
The system will test all its connections and can send a report to your monitoring station. If the system detects a problem, the Trouble Display will show on the screen (refer to section 9.0 on page 19). Call your installer for repairs if any troubles occur.
ACCESS CODE].
EVO Systems 25
13.0 Fire and Burglar Alarms
LCD LED
LCD LED
13.1 Standard Fire Zone
During a fire alarm, the bell/siren emits an intermittent sound (BEEP-BEEP-BEEP) until silenced or reset. If the zone is a St andard Fire Zone, your system can immediately send an alert to your monitoring station.
To disarm a false alarm:
1. Enter your [
ACCESS CODE] on the keypad.
2. Call your monitoring station quickly to advise them of the false alarm.
The Fire Zone may reset itself once the problem has cleared. If it does not, simultaneously press and hold the [
CLEAR] and [ENTER] buttons for two
seconds.
13.2 Delayed Fire Zone
If the zone is a Delayed Fire Zone, there is an automatic delay before your system contacts your monitoring station. Refer to Figure 7 on page 27 to prevent unnecessary reporting of false alarms.
If the fire alarm is accidentally triggered:
1. Press the [
2. Clear the problem from the area (i.e. clear the smoke from around the smoke detector).
3. If the problem remains after 90 seconds, the alarm will sound again. Press [ again.
4. The system will delay reporting the alert for another 30 seconds.
CLEAR] button within 30 seconds of the alarm.
CLEAR]
If you are unable to cancel the false alarm, your system will send an alert. Call your monitoring station to advise them of the false alarm.
The Fire Zone may reset itself once the smoke has cleared. If it does not, simultaneously press and hold the [
CLEAR] and [ENTER] buttons for two
seconds or speak to your installer.
13.3 Fire Safety Tips
How should you prepare in case of a fire in your home or business?
Remind everyone to escape first, and then call for help.
Develop a fire escape plan and designate a meeting place outside.
Practice the escape plan frequently.
Plan two ways to escape from every room, if possible.
Practice feeling the way out with eyes closed.
Instruct everyone never to stand up during a fire, always crawl under the smoke and keep mouths covered.
Instruct everyone never to return to a burning building for any reason; it may cost them their life.
Check smoke alarms regularly. Working smoke alarms dramatically increase everyone's chances of surviving a fire.
26 User Guide
Figure 7: Delayed Fire Zone
13.4 Minimizing Home Fire Hazards
How can you avoid the three most common causes of fires at home?
Never leave cooking food unattended. It’s the leading cause of fire injuries. Cooking fires often result from unattended cooking and human error, rather than mechanical failure.
Stay alert when smoking. Careless smoking is the leading cause of fire deaths. Smoke detectors and smoulder-resistant bedding and upholstered furniture are significant fire deterrents.
Maintain your heating system. Faulty heating systems are the second leading cause of residential fires.
13.5 Home Fire Warning System
Household fires are especially dangerous at night. Fires produce smoke and deadly gases that can overcome occupants while they sleep. To warn against fire, install smoke detectors outside each separate sleeping area in the immediate vicinity of the bedrooms and on each additional story of the family living unit, including basements.
13.6 Burglar Alarm
If your armed system is breached, the burglar alarm devices specific to your system will be triggered. The feedback will vary depending on the type of keypad used. If your keypad is in Normal Mode:
In Alarm will appear on LCD screen.
Bell or siren may be activated.
The keypad may beep. The M
EM action light will illuminate.
In case of a burglar alarm, leave the premises and call the police station from a safe place.
EVO Systems 27
Appendix 1: Hebrew Special Characters
032 048 064 080 096 112 160 176 192 208 224 240
033 049 065 081 097 113 161 177 193 209 225 241
034 050 066 082 098 114 162 178 194 210 226 242
035 051 067 083 099 115 163 179 195 211 227 243
036 052 068 084 100 116 164 180 196 212 228 244
037 053 069 085 101 117 165 181 197 213 229 245
038 054 070 086 102 118 166 182 198 214 230 246
039 055 071 087 103 119 167 183 199 215 231 247
040 056 072 088 104 120 168 184 200 216 232 248
041 057 073 089 105 121 169 185 201 217 233 249
042 058 074 090 106 122 170 186 202 218 234 250
043 059 075 091 107 123 171 187 203 219 235 251
044 060 076 092 108 124 172 188 204 220 236 252
045 061 077 093 109 125 173 189 205 221 237 253
046 062 078 094 110 126 174 190 206 222 238 254
047 063 079 095 111 127 175 191 207 223 239 255
Refer to the following tables when programming the user labels of a Hebrew LCD keypad. Instead of using Table 2 on page 12 and Table 3 on page 13, use Tables 9 and 10 below. Refer to section 7.3 on page 11 for information on programming user labels.
Table 5: Hebrew Keypad Letter Assignment
Table 6: Hebrew Special Characters Catalogu e
28 User Guide
Appendix 2: Russian Special Characters
032 048 064 080 096 112 160 176 192 208 224 240
033 049 065 081 097 113 161 177 193 209 225 241
034 050 066 082 098 114 162 178 194 210 226 242
035 051 067 083 099 115 163 179 195 211 227 243
036 052 068 084 100 116 164 180 196 212 228 244
037 053 A069 085 101 117 165 181 197 213 229 245
038 054 070 086 102 118 166 182 198 214 230 246
039 055 071 087 103 119 167 183 199 215 231 247
040 056 072 088 104 120 168 184 200 216 232 248
041 057 073 089 105 121 169 185 201 217 233 249
042 058 074 090 106 122 170 186 202 218 234 250
043 059 075 091 107 123 171 187 203 219 235 251
044 060 076 092 108 124 172 188 204 220 236 252
045 061 077 093 109 125 173 189 205 221 237 253
046 062 078 094 110 126 174 190 206 222 238 254
047 063 079 095 111 127 175 191 207 223 239 255
Refer to the following tables when programming the user labels of a Russian LCD keypad. Instead of using Table 2 on page 12 and Table 3 on page 13, use Tables 11 and 12 below. Refer to section 7.3 on page 11 for information on programming user labels.
Table 7: Russian Keypad Letter Assignment
Table 8: Russian Special Characters Catalogue
EVO Systems 29
Appendix 3: Greek Special Characters
016 032 048 064 080 096 112 128 144 160 176 192 208 224 240
017 033 049 065 081 097 113 129 145 161 177 193 209 225 241
018 034 050 066 082 098 114 130 146 162 178 194 210 226 242
019 035 051 067 083 099 115 131 147 163 179 195 211 227 243
020 036 052 068 084 100 116 132 148 164 180 196 212 228 244
021 037 053 A069 085 101 117 133 149 165 181 197 213 229 245
022 038 054 070 086 102 118 134 150 166 182 198 214 230 246
023 039 055 071 087 103 119 135 151 167 183 199 215 231 247
024 040 056 072 088 104 120 136 152 168 184 200 216 232 248
025 041 057 073 089 105 121 137 153 169 185 201 217 233 249
026 042 058 074 090 106 122 138 154 170 186 202 218 234 250
027 043 059 075 091 107 123 139 155 171 187 203 219 235 251
028 044 060 076 092 108 124 140 156 172 188 204 220 236 252
029 045 061 077 093 109 125 141 157 173 189 205 221 237 253
030 046 062 078 094 110 126 142 158 174 190 206 222 238 254
031 047 063 079 095 111 127 143 159 175 191 207 223 239 255
Refer to the following tables when programming the user labels of a Greek LCD keypad. Instead of using Table 2 on page 12 and Table 3 on page 13, use Tables 13 and 14 below. Refer to section 7.3 on page 11 for information on programming user labels.
Table 9: Greek Keypad Letter Assignment
Key Press key once Press key twice
[1] [2] [3] [4] [5] [6] [7] [8]
#$)
&'<
*3 +
-./
01
245
67(
%;9
Table 10: Greek Special Characters Catalogue
Press key three
times
30 User Guide
Index
A
Access Codes
Deleting .................................................................................. 13
Labelling ................................................................................ 11
Programming ......................................................................... 13
System Master ....................................................................... 1 1
User ....................................................................................... 11
Access Control ............................................................................... 15
Entering & Exiting .................................................................. 17
Access Control User Options
Access Control ....................................................................... 1 5
Add Tolerance Window to Schedule ...................................... 1 6
Arming with Card ................................................................... 16
Can Disarm with Access Card ............................................... 15
Card to Unlock and Code to Disarm ...................................... 16
Code Follows Schedule ......................................................... 16
Extended Unlocked Period .................................................... 16
Add Tolerance Window to User Schedule ..................................... 16
Alarm Memory Display ................................................................... 10
Alarm,Testing ................................................................................. 25
Area Access, in User Options ........................................................ 15
Area Display .................................................................................... 6
Arming
Automatic Arming .................................................................... 9
Force Arming ........................................................................... 7
Instant Arming .......................................................................... 7
Keyswitch Arming .................................................................... 8
Regular Arming ........................................................................ 7
Stay Arming ............................................................................. 7
with Card ................................................................................ 17
Auto-Arming
No Movement Auto-Arming ..................................................... 9
Timed Auto-Arming .................................................................. 9
B
Basic Operation ............................................................................... 3
Battery
Disconnected ......................................................................... 1 9
Low, in a Zone ....................................................................... 19
Beep Tones
Confirmation beep ................................................................... 4
in Opened or Closed Zones, see Chime Zones
Rejection beep ......................................................................... 4
Bell Disconnected .......................................................................... 19
Burglar Alarms ............................................................................... 27
Buttons
One-Touch ............................................................................... 8
Quick Function ....................................................................... 22
Bypass
Bypass Recall .......................................................................... 8
Programming ........................................................................... 7
C
Card, Access Control
Arming with ............................................................................ 17
Disarming with ....................................................................... 17
Characters, Special ....................................................................... 13
Chime Zones ................................................................................. 22
Clock, Set Time and Date .............................................................. 21
Code Follows Schedule ................................................................. 16
Copy User Options .........................................................................11
D
Date, Set .........................................................................................21
Deactivating a Security System ......................................................10
Delay Timer
Entry .......................................................................................10
Exit ............................................................................................7
Delayed Fire Zone ..........................................................................26
Deleting User Access Codes ..........................................................13
DGP2-648BL LED Keypad Overview ...............................................3
Disarming
Armed System ........................................................................10
with Card ................................................................................17
Display
Alarms In Memory ..................................................................10
User Actions in Memory .........................................................20
Duress, in User Options ..................................................................15
E
Emergency Buttons ........................................................................22
Entering and Exiting, Access Control Doors ...................................17
Entry Delay Timer ...........................................................................10
Erasing User Access Codes ...........................................................13
Event Record Display .....................................................................20
Exit Delay Timer ...............................................................................7
Extended Unlocked Period .............................................................16
F
Fire
Delayed Fire Zone ..................................................................26
Minimizing Home Fire Hazards ..............................................27
Safety Tips ..............................................................................26
Standard Fire Zone .................................................................26
Warning System .....................................................................27
Fire Alarm, Testing .........................................................................25
Force Arming ....................................................................................7
G
Greek Special Characters ...............................................................30
H
Hebrew Special Characters ............................................................28
I
Ignoring Zones when Arming, see Bypass Programming
Instant Arming ...................................................................................7
K
Keypad, LCD
Buttons .....................................................................................3
Letter Assignment ...................................................................12
Lights ........................................................................................3
Messages .................................................................................3
Settings ...................................................................................21
Keyswitch Arming .............................................................................8
EVO Systems 31
M
Master Code .................................................................................. 11
Master Feature, in User Options .................................................... 15
MG-REM2 Feedback ....................................................................... 5
N
No Movement Auto-Arming ............................................................. 9
O
One Touch Button for the DGP-641BL/RB and the DGP-648 ......... 8
One-Touch buttons .......................................................................... 8
Outputs, Programmable (PGM) ..................................................... 21
P
Panic Alarms .................................................................................. 22
Power Failure, see Trouble
Programmable Outputs (PGM)....................................................... 21
Programming
Chime Zones ......................................................................... 22
User Access Codes ......................................................... 13–15
Q
Quick Function Buttons
Answer Winload Sofware ....................................................... 22
Call Winload Software ........................................................... 22
Cancel Communication with Winload Software ..................... 22
Send Test Report ................................................................... 22
R
Recall, Bypassed Zones .................................................................. 8
Regular Arming ................................................................................ 7
Request for Exit ............................................................................. 17
Russian Special Characters .......................................................... 29
S
Safety Tips, Fire ............................................................................. 26
Schedule
Code Follows ......................................................................... 16
Schedule Tolerance Window, see Add Tolerance to User Schedule
Siren Disconnected ........................................................................ 19
Special Characters ........................................................................ 13
Special Characters, Greek ............................................................. 30
Special Characters, Hebrew .......................................................... 28
Special Characters, Russian ......................................................... 29
Special Function Keys ................................................................... 12
Standard Fire Zone ........................................................................ 26
Stay Arming ..................................................................................... 7
System Master Code ..................................................................... 11
System Test ................................................................................... 25
Timer
Entry Delay .............................................................................10
Exit Delay .................................................................................7
Trouble
AC Failure ...............................................................................19
Battery ....................................................................................19
Bell/Siren Disconnected .........................................................19
Clock .......................................................................................20
Communicator ........................................................................19
Fail to Communicate ...............................................................19
Fail to Communicate PC .........................................................19
Low Battery, Zone ..................................................................19
System ....................................................................................19
TLM1 ......................................................................................19
Zone Fault ..............................................................................19
Zone Tampering .....................................................................19
U
Unlocked Period, Extended ............................................................16
User Labels .....................................................................................11
User Options
Access Control, see Access Control User Options
Area Access ...........................................................................15
Arm Only .................................................................................15
Bypass ....................................................................................15
Copy .......................................................................................11
Duress ....................................................................................15
Force Arm ...............................................................................15
Master Feature .......................................................................15
Programming ..........................................................................15
Stay & Instant Arm ..................................................................15
User Settings ..................................................................................14
V
VDMP3 Plug-In Voice Dialer ...........................................................23
Viewing
Alarms In Memory ..................................................................10
User Actions in Memory .........................................................20
T
Tampered Zones ........................................................................... 19
Testing and Maintenance
Burglar Alarm ......................................................................... 25
Fire Alarm .............................................................................. 25
System Maintenance ............................................................. 25
System Test ........................................................................... 25
Time, Set ....................................................................................... 21
Timed Auto-Arming .......................................................................... 9
EVO Systems 32
Warranty
For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. Your use of the Par adox product signifies your acceptance of all warranty terms and conditions.
BEWARE: Dealers, installers and/or others selling the product are not authorized to modify this warranty or make additional warranties that are binding on the Seller.
© 2002-2007 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 6215399, 6111256, 5751803, 5721542, 52871 11, 5119069, 5077549, 59202 59, 588 6632. Canadian and international patents may also apply.
Digiplex, InTouch, WinLoad and NEware are trademarks or registered trademarks of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries.
Limitations of Alarm Systems
We strongly advise that you review and take into consideration the “Limitations of Alarm Systems” document available on our website at http:// paradox.com/Terms/.
Warning for Connections to Non-Traditional Telephony (eg. VoIP)
Paradox alarm equipment was designed to work effectively around traditional telephone systems. For those customers who are using a Paradox alarm panel connected to a non-traditional telephone system, such as "Voice Over Internet Protocol" (VoIP) that converts the voice signal from your telephone to a digital signal traveling over the Internet, you should be aware that your alarm system may not function as effectively as with traditional telephone systems. For example, if your VoIP equipment has no battery back-up, during a power failure your system's ability to transmit signals to the central station may be compromised. Or, if your VoIP connection becomes disabled, your telephone line monitoring feature may also be compromised. Other concerns would include, without limitation, Internet connection failures which may be more frequent than regular telephone line outages. We therefore strongly recommend that you discuss these and other limitations involved with operating an alarm system on a VoIP or other non­traditional telephone system with your installation company. They should be able to offer or recommend measures to reduce the risks involved and give you a better understanding.
EVO Systems 33
For technical support in Canada or the U.S., call 1-800-791-1919, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST.
For technical support outside Canada and the U.S., call 00-1-450-491-7444, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST.
Please feel free to visit our website at www.paradox.com.
Printed In Canada - 11/2007 paradox.com EVO-EU02
Loading...