INSTALLATION INSTRUCTIONS
Z23C-** Preconfigured Network Zone System
V00028MW
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 1 of 11
Page 2
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
TABLE OF CONTENTS
V00028MW
Overview of Products Specs / Tools Needed Safety Information / Warnings Wall Mounting Bracket Installation Wall Mounting Removable Gland Plate Reversible Door Integrated Layout Recommended Installation Instructions for: Cage Removal Power Entry
Page 3 Page 4 Page 5 Page 6 Page 7 Page 7 Page 8 Page 9
Uplink Entry Downlink Entry Patch Cord Routing
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 2 of 11
Page 3
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
V00028MW
R
A
B
Q
C
L
J I
H
G
D
F
E
Preconfigured Network Zone System Z23C-** configurations include the following:
Pictured Above Not Pictured A). 24" x 36" Enclosure S). Hook and Loop Ties B). Preconfigured Back Panel T). CAT6 Copper Patch Cords (16) C). Strain Relief Bar U). CAT6 Mini-Com Modules (16) D). 48 Port Patch Panel V). Cable Tie Push Mounts E). Gland Plate W). Cable Ties F). Ground Bar X). LC Fiber Patch Cords (4) G). 21.0" Din Rail Y). High Voltage Barrier H). Accessory Side Panels I). 17.75" Din Rail (2) J). Fiber Spool L). LC Fiber Optic Modules (6) Q). Fiber Surface Mount Box R). 700 mm L-rings
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 3 of 11
Page 4
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS

Preconfigured Network Zone Z23C-** Specifications

V00028MW

Enclosure Rating

Installation

UL Type 4/12 and IP66 (IEC 60529), NEMA 4X available

Wall mount with optional outside-mount flange

Height Width Depth

Dimensions

Weight

36.0”

(914 mm)

90 lbs. (40.8 kg)

24.0”

(610 mm)

11.7”

(297 mm)

Tools and supplies needed to complete install of Preconfigured Zone System (not included):
· Fiber-optic trunk cable: FSPD504 or similar
· LC Fiber-optic connectors: FLCDMCXAQY or similar
· Tools to cut enclosure sidewalls: Greenlee punch or similar
· 5/16” bolts for wall mounting of steel enclosure
· Fiber-optic termination tools: OptiCam termination kit or
similar
· Category 6 copper cable for downlinks: PUR6504BU-UY or
similar
· Copper cable termination tools: wire cutters, EGJT tool
· Rigid conduit for power and copper downlink cables
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 4 of 11
· #6 AWG Infrastructure ground cable: RGEJ660PF or similar
· 3/8" bolts for wall mounting of stainless steel enclosure
· 3/8" socket or box wrench ground bar
Page 5
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
V00028MW
SAFETY INFORMATION
The information and instructions contained in this document are not intended to be utilized as a substitute for proper training and experience in the safe installation and operation of product. Prior to installation, it is the Buyer’s responsibility to consult with the appropriate local Authority Having Jurisdiction (AHJ) for all applicable codes, permits, regulations and standards.
This product, including any equipment that may be installed inside, should only be installed and serviced by a licensed electrical contractor, or competent technician, that meets the following qualifications;
Is thoroughly familiar with this product and the instructions for installation and operation
Is trained (accredited) in industry-accepted safe operating practices and procedures regarding identification and mitigation of high- and low- voltage hazards and situations.
Is trained to identify and install appropriately-sized Branch Circuit Disconnect(s) with appropriately-sized Branch-Circuit Protective Rating and Short-Circuit Current Rating (SCCR), before connecting Panduit product to the branch circuit.
Is trained and authorized to energize, de-energize, clear and ground power distribution equipment.
• Is trained in the care and use of PPE (personal protective equipment) including, but not limited to; arc-flash protective clothing, safety glasses, face shield, hard hat, gloves, and non-conductive tools (clamp stick, hot stick, etc
WARNING
Be sure wall is capable of supporting cabinet and equipment.
DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES
The practices contained herein are designed as a guide for use by persons having technical skill at their own discretion and risk. Panduit does not guarantee any favorable results or assume any liability in connection with these instructions. Local, State, Federal, and Industry Codes and Regulations, as well as manufacturers requirements, must be consulted before proceeding with any project. Panduit Corp. makes no representations of nor assumes any responsibility for the accuracy or completeness set forth herein. Panduit disclaims any liability arising from any information contained
herein or for the absence of same.
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 5 of 11
Page 6
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
Wall Mounting Bracket Installation
Note: The enclosure may be mounted to the wall without the mounting brackets
Step 1: Turn enclosure on its side with the locks orientated
towards the top. Using Latch Tool, turn both locks towards each other to open door. Step 2: Install Wall Mounting Brackets into back of the enclosure aligning threaded studs on brackets to holes located in back of the enclosure. Be sure obround mount­ing holes on the wall mounting bracket align outward. Step 3: Secure wall mounting brackets using the supplied sealing washers use (1) per threaded stud.
Torque spec:
Steel Enclosure: 5/16" washers = 30 in-lbs Stainless Steel Enclosure: 3/8" washers = 40 in-lbs Step 4: Close Door. Using Latch Tool, turn both locks to secure the door.
If Mounting Flanges are not used:
For Steel Enclosure: Use 5/16" Sealing Washer (supplied) and a 5/16" Bolt (not supplied) in the locations where the threaded studs in the mounting flanges would go to mount enclosure directly to wall. For Stainless Steel Enclosure: Use 3/8" Sealing Washer (supplied) and a 3/8" Bolt (not supplied) in the locations where the threaded studs in the mounting flanges would go to mount enclosure directly to wall.
Step 1
Latch Tool
V00028MW
Wall Mounting Brackets
Step 2
Sealing Washer
Hex Nut
Detail View
4 Places
(not provided)
Screw
Step 3
Washer
(provided)
Mounting Flanges not
used (4 places)
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 6 of 11
Page 7
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
Wall Mounting
V00028MW
Enclosure may be mounted on any wall utilizing Unistrut or by drilling directly into any concrete wall. There are two mounting hole locations on the top flange and two locations at the bottom flange.
Step 1:
Drill holes 19.25"-22" apart horizontally and 38" apart vertically.
Step 2:
Mount the enlosure with the locks to the right and secure.
If mounting flanges are not used:
The holes in the wall will be 22.5" apart horizontally and 34.5" apart vertically.
Hole Locations for Wall Mounting
19.25” - 22.0”
22.5”
38”
34.5”
Dimensions for Wall Mounting without Flanges
Removable Gland Plate
Remove the gland plate prior to drilling holes for conduit entry. Accommodations for incoming conduit have been supplied on the enclo­sure. This will help prevent metal shavings from entering the electronic components in the enclosure. Recommend installation of IP66 rated conduit fittings that comply with the IEC codes that are applicable to the intended application. The Gland Plate, located on bottom of the enclosure, is removable for machining to accept bulkhead connectors or compression fittings. To remove gland plate,(12) screws and (12) flat washers attached to the threaded studs of the gland plate and remove plate from the enclo­sure.When reinstalling the gland plate, ensure the nuts are tightened until the gland plate flanges make contact with the enclosure surface.
Gland Plate
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 7 of 11
Page 8
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
Reversible Door
The enclosure comes with the door opening to the left. The door may be reversed to open to the right.
Step 1: Remove pins from the door hinges. Step 2: Remove screws and door hinges Step 3: New Hole locations will have to be drilled or punched out. Reinstall hinges and screws on opposite side. Step 4: Turn door 180 degrees and mount to the opposite side of the enclosure. Insert the same pins to secure the door.
V00028MW
Step 1
Add silicone to bolts (6x) (Not Supplied)
Step 2
Step 4
Step 3
Torque 33 in-lbs.
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 8 of 11
Page 9
© Panduit Corp. 2014
Stratix din rail mounted switches with expansion modules. (Not provided)
INSTALLATION INSTRUCTIONS V00028MW
Proposed Integrated Layout
Din Rail Mount Copper Patch Box (Not provided)
Push Mounts (Provided)
Industrial Switch Power Supplies (Not provided)
Electrical Circuit Breakers and Terminals (Not provided)
Panduit Uninterrupted Power Supply (Not provided)
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 9 of 11
Page 10
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
V00028MW
Remove(3) #10-32 screws and washers
Cage Removal
Recommended Installation
Instructions for Power Entry
Remove plug in gland plate and replace with conduit fitting. Recommend installation of IP66 rated conduit fit­tings that comply with the IEC codes that are applica­ble to the intended applica­tion.
Connect Infrastructural ground to ground bar
Power Conduit Entry
Recommended Installation
Instructions for Uplink Entry
Uplink cable (fiber shown) spooled in the surface mount box
Uplink Cable Conduit Entry
Recommended Installation
Instructions for Downlink Entry
Service loop formed behind the patch panel or on top of the cable management L rings.
Downlink Cable Conduit Entry
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 10 of 11
Page 11
© Panduit Corp. 2014
Patch cords supported by the strain relief bar and L-ring managers, routed from the switch to the patch panel (Switch not included) Secure with hook and loop that is provided
INSTALLATION INSTRUCTIONS
Recommended Installation Instructions
for Patch Cord Routing
V00028MW
Route fiber cord from surface mount box to switch. Route fiber patch cord slack on the fiber spool in between box and switch.
For Instructions in Local Languages
and Technical Support:
For Technical Support: http://www.panduit.com/wcs/Satel-
lite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
www.panduit.com
Page 11 of 11