Panduit Z22C-6 Installation Manual

Page 1
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
Z22C-** Preconfigured Network Zone System
V00028NW
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 1 of 12
Page 2
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
TABLE OF CONTENTS
V00028NW
Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10
Page 11 Page 11
Uplink Entry Downlink Entry Patch Cord Routing
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 2 of 12
Page 11 Page 11 Page 12
Page 3
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
V00028NW
A
B
C
D
L
K
J
I
H
G
E
Integrated Network Zone System Z22C-**configurations include the following:
Pictured Above A). 24" x 24" Enclosure B). Preconfigured Back Panel C). Strain Relief Bar D). Management Slack L-rings E). Gland Plate F). Ground Bar G). 21.0" Din Rail H). Accessory Side Panels I). Fiber Spool J). 17.75" Din Rail K). LC Fiber Optic Modules (6) L). Fiber Surface Mount Box
F
Not Pictured M). Hook and Loop Ties N). Cable Tie Push Mounts O). Cable ties P). High Voltage Barrier Q). LC Fiber Patch Cords (2) R). CAT6 Copper Patch Cords (8) S). CAT6 Mini-Com Modules (8)
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 3 of 12
Page 4
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
Preconfigured Network Zone Z22C-** Specifications
V00028NW
Enclosure Rating Installation
Dimensions
Weight
Tools and supplies needed to complete install of Preconfigured Zone System: (not included)
· Fiber-optic trunk cable: FSPD504 or similar
UL Type 4/12 and IP66 (IEC 60529), NEMA 4X available Wall mount with optional outside-mount flange
Height Width Depth
24”
(610 mm)
24”
(610 mm)
11.7”
(297 mm)
75 lbs. (34.0 kg)
· Tools to cut enclosure sidewalls: Greenlee punch or similar
· LC Fiber-optic connectors: FLCDMCXAQY or similar
· Fiber-optic termination tools: OptiCam termination kit or similar
· Category 6 copper cable for downlinks: PUR6504BU-UY or similar
· Copper cable termination tools: wire cutters, EGJT tool
· Rigid conduit for power and copper downlink cables
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 4 of 12
· 5/16” bolts for wall mounting of steel enclosure
· #6 AWG Infrastructure ground cable: RGEJ660PF or similar
· 3/8" bolts for wall mounting of stainless steel enclosure
· 3/8" socket or box wrench ground bar
Page 5
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
SAFETY INFORMATION
V00028NW
DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES
The practices contained herein are designed as a guide for use by persons having technical skill at their discretion and risk. Panduit does not guarantee any favorable results or assume any liability in connection with these instructions. Local, State, Federal, and Industry Codes and Regulations, as well as manufacturers requirements, must be consulted before proceeding with any project. Panduit Corp. makes no representations of nor assumes any responsibility for the accuracy or completeness set forth herein. Panduit disclaims any liability arising from any information contained herein or for the absence of same.
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 5 of 12
Page 6
© Panduit Corp. 2014
Wall Mounting Bracket Installation
Note: The enclosure may be mounted to the wall without the mounting brackets
Step 1: Turn enclosure on its side with the locks orientated
towards the top. Using Latch Tool, turn both locks towards
each other to open door. Step 2: Install Wall Mounting Brackets into back of the enclo-
sure aligning threaded studs on brackets to holes located in back of the enclosure. Be sure obround mounting holes on the wall mounting bracket align outward. Step 3: Secure Wall Mounting brackets using sealing washers and (1) per threaded stud.
Torque spec:
Steel Enclosure: 5/16" washers = 30 in-lbs Stainless Steel Enclosure: 3/8" washers = 40 in-lbs Step 4: Close Door. Using Latch Tool, turn both locks to secure the door.
If Mounting Flanges are not used:
For Steel Enclosure: Use 5/16" Sealing Washer (supplied) and a 5/16" Bolt (not supplied) in the locations where the threaded studs in the mounting flanges would go to mount enclosure directly to wall. For Stainless Steel Enclosure: Use 3/8" Sealing Washer (sup­plied) and a 3/8" Bolt (not supplied) in the locations where the threaded studs in the mounting flanges would go to mount enclosure directly to wall.
INSTALLATION INSTRUCTIONS
Step 1
V00028NW
Latch Tool
Wall Mounting Brackets
Step 2
Sealing Washer
Hex Nut
(not provided)
Detail View
Step 3
Washer
(provided)
Screw
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 6 of 12
Page 7
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
Wall Mounting
Enclosure may be mounted on any wall utilizing Unistrut or by drilling directly into any concrete wall. There are two mounting hole locations on the top flange and two locations at the bottom flange.
Step 1:
Drill holes 19.25"-22" apart horizontally and 26" apart vertically.
Step 2:
Mount the enlosure with the locks to the right and secure.
If mounting flanges are not used:
The holes in the wall will be 22.5" apart horizontally and 34.5" apart vertically.
V00028NW
Hole Locations for Wall Mounting
Backview for wall mounting
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 7 of 12
Page 8
© Panduit Corp. 2014
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
V00028NW
Removable Gland Plate
The Gland Plate, located on the bottom of the enclosure, is removable for machining to accept bulkhead connectors or compression fittings. Remove (12) screws and (12) flat washers on the bottom of the enclosure to remove plate from the enclosure. Accommoda­tions for incoming conduit have been supplied on the enclosure. A 1/2” conduit plug is installed in the recommended incoming power location. Recommend installation of IP66 rated conduit fittings that comply with the IEC codes that are applicable to the intended application. When reinstalling the gland plate, ensure the screws are tightened until the gland plate flanges make contact with the enclosure surface.
Plug
Gland plate
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 8 of 12
Page 9
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
Reversible Door
The enclosure comes with the door opening to the left. The door may be reversed to open to the right.
Step 1: Remove pins from the door hinges. Step 2: Remove screws and door hinges Step 3: New Hole locations will have to be drilled or punched out. Reinstall hinges and screws on opposite side. Step 4: Turn door 180 degrees and mount to the opposite side of the enclosure. Insert the same pins to secure the door.
V00028NW
STEP 2
STEP 3
Torque 33 in-lbs.
STEP 1
Add silicone to bolts (6x) (not supplied)
STEP 4
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 9 of 12
Page 10
© Panduit Corp. 2014
Stratix Din Rail Mounted Switch (Not Provided)
Din Rail Mount Copper Patch Box (Not Provided)
INSTALLATION INSTRUCTIONS
Proposed Layout
V00028NW
Din Rail Mount Copper Module (One Provided) for up to 8 CAT6 Mini-Com Modules
Push Mounts (Provided)
Electrical Circuit Breakers and Terminals (Not Provided)
Industrial Switch Power Supplies (Not Provided)
Panduit Uninterrupted Power Supply (Not Provided)
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 10 of 12
Page 11
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
V00028NW
Remove(3) #10-32 screws
Cage Removal
Recommended Installation Instructions for Power Entry
Remove plug in gland plate and replace with conduit fitting. Recommend installation of IP66 rated conduit fit­tings that comply with the IEC codes that are applicable to the intended application.
Connect infrastruc­tural ground to ground
Power Conduit Entry
Recommended Installation Instructions for Uplink Entry
Uplink Cable (fiber shown) spooled in the surface mount box
Uplink Cable Conduit Entry
Recommended Installation Instructions for Downlink Entry
Slack loop formed around the L-ring cable managers
Downlink Cable Conduit Entry
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Page 11 of 12
Page 12
© Panduit Corp. 2014
Patch cords supported by the strain relief bar and L-ring managers, routed from the switch to the patch module
INSTALLATION INSTRUCTIONS
Patch Cord Routing
V00028NW
Slack tied to towel bar with hook and loop ties. (Provided)
Fiber patch cord slack on the side mounted spool
For Instructions in Local Languages
http://www.panduit.com/wcs/Satellite?pagename=PG_Wrap-
and Technical Support:
per&friendlyurl=/en/support/contact-us
www.panduit.com
Page 12 of 12
E-mail:
tp-csdebt@panduit.com