Preconfigured Network Zone System Z11C-** configurations include an enclosure and cable
management.
V00028RH
Be sure wall is capable of supporting cabinet and equipment.
DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITIES
The practices contained herein are designed as a guide for use by persons having technical skill at their own discretion and risk. Panduit
does not guarantee any favorable results or assume any liability in connection with these instructions. Local, State, Federal, and Industry
Codes and Regulations, as well as manufacturers requirements, must be consulted before proceeding with any project. Panduit Corp.
makes no representations of nor assumes any responsibility for the accuracy or completeness set forth herein.
Panduit disclaims any liability arising from any information contained herein or for the absence of same.
SAFETY INFORMATION
The information and instructions contained in this document are not intended to be utilized as a substitute for proper training and
experience in the safe installation and operation of product. Prior to installation, it is the Buyer’s responsibility to consult with the
appropriate local Authority Having Jurisdiction (AHJ) for all applicable codes, permits, regulations and standards.
This product, including any equipment that may be installed inside, should only be installed and serviced by a licensed electrical
contractor, or competent technician, that meets the following qualifications;
·Is thoroughly familiar with this product and the instructions for installation and operation
·Is trained (accredited) in industry-accepted safe operating practices and procedures regarding identification and mitigation of
high- and low- voltage hazards and situations.
·Is trained to identify and install appropriately-sized Branch Circuit Disconnect(s) with appropriately-sized Branch-Circuit
Protective Rating and Short-Circuit Current Rating (SCCR), before connecting Panduit product to the branch circuit.
·Is trained and authorized to energize, de-energize, clear and ground power distribution equipment.
Is trained in the care and use of appropriate PPE (personal protective equipment) including, but not limited to; arc-flash protective clothing, safety glasses, face shield, hard hat, gloves and non-conductive tools (clamp stick, hot stick, etc.).
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Enclosure may be mounted on any wall utilizing Unistrut or by drilling directly into any concrete wall.
There are two mounting hole locations on the top flange and two locations at the bottom flange.
Step 1:
Drill holes 7.25"-10" apart horizontally and 16" apart vertically.
Step 2:
Mount the enlosure with the locks to the right and secure.
INSTALLATION INSTRUCTIONS
Wall Mounting
V00028RH
16"
7.25"-10"
Hole Locations for Wall Mounting
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
The enclosure comes with the door opening to the left.
The door may be reversed to open to the right.
Step 1: Remove screws and washers from door hinges.
Step 2: Turn door 180 degrees and mount to opposite side of enclosure using same screws and washers.
**New Hole locations will have to be drilled or punched out.**
Detail View-2 Places
Step 1
V00028RH
Torque 33 in-lbs.
Detail View-2 Places
Step 2
Removable Gland Plate
The Gland Plate, located on the bottom of the enclosure, is removable for machining to accept bulkhead connectors or compression fittings.
To remove gland plate, unfasten the (10) nuts and (10) flat washers attached to the threaded studs of the gland plate and remove plate
from the enclosure.
When reinstalling the gland plate, ensure the nuts are tightened until the gland plate flanges make contact with the enclosure surface.
Remove nuts and washers
Gland Plate
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us
Recommended Installation Instructions for Bundled Accessories
Preconfigured Network
Stratix 5700 Industrial
DIN Rail
Switch
Cable management L-rings
mounted to the side accessory panel
V00028RH
Run incoming 24 VDC power
through conduit installed on top or
bottom gland plate. Install power
wiring according to the field wiring
diagram. (Conduit or cord grips
provided by customer)
Ground Wire
Power Entry
For Technical Support: http://www.panduit.com/wcs/Satellite?pagename=PG_Wrapper&friendlyurl=/en/support/contact-us