Heat Trace

PA27801A01
HTMLT Tie
Pipe Diameter
Part Number
Width (in.)
Length (in.)
ST2MT/ST4MT Tools
Std. Pkg.
Qty.
HTMLT2.7WEH-LP
0.50
10.2
1.0
50
HTMLT4WEH-LP
0.50
14.3
2.0
50
HTMLT6WEH-LP
0.50
20.5
3.0, 4.0
50
HTMLT8WEH-LP
0.50
26.8
6.0
50
HTMLT10WEH-LP
0.50
33.0
7.0, 8.0
50
HTMLT12WEH-Q
0.50
42.2
9.0, 10.0
25
HTMLT16WEH-Q
0.50
54.8
11.0, 12.0, 14.0
25
HTMLT26WEH-Q
0.50
86.2
16.0, 20.0, 24.0
25
HTMLT38WEH-Q
0.50
123.9
26.0 - 36.0
25

Installation Instr uctions

© Panduit Corp. 2015
Safety glasses must be worn at all times by all persons within ten (10) feet o f working metal tie installation tool. CAUTION: Be aware of the ejection of metal cable tie scrap from tool.
Safety gloves must be worn while applying metal ties using this tool.
DO NOT use tool on live electrical sources.
DO NOT place fingers near gripper during tool actuation. Fingers may be pinched by moving gripper.
1. Determine minimum acceptable required length for Heat Trace Wave-Ty
Nominal pipe diameters are based on either inside diameter (ID) or outside diameter (OD); and there are a number of schedules available throughout the internet.
ID is used for pipes sized from 0 – 12 inches. Greater than 12 inch pipe is typically measured in terms of OD.
The Panduit Heat Trace Wave Ty can cover pipes ranging from 1 inch up to 36 inches.
2. Use look up table for pipe diameters and Heat Trace Wave Ty part numbers.
Rev. 00 12-2015
If you have a pipe diameter that is not listed on the table, mov e to the next highest s ize;, i.e., 5 inch pipe diameter. This would require the use of the HTMLT8WEH-LP for the ST2MT/ST4MT tool
3. Once you have selected th e right size He at Trace Wav e Ty, go to actual onsite instal lation. For purp oses of installing heat trace, first position heat trace against the pipe.
Page: 1 of 2
Page 2
© Panduit Corp. 201
5
HEAT TRACE
WITH ST2MT & ST4MT
ST4MT). Once HTMLT tie is
6. Once tail is positioned through head of tool, begin squeezing handle

Tel: 1-800-777-3300

Tel: +31-546-580-452 • Fax: +31-546-580-441
Tel: 65 6379 6700 • Fax: 65 6379 6759
INSTALLATION INSTRUCTIONS
4. Once positioned in p lace, wrap HTMLT tie aroun d pipe and heat trace every 12 inches. Fe ed the tail into the head of the wave ty and manual position and ti ghten. Do n ot posit ion h ead of tie ov er the heat trace.
5. Use recommended tool for Heat Trace application (either RT2HT, ST2MT or positioned and hand tightened around pipe and heat trace, begin feeding tail through side entry head of tool.
to begin tightening HTMLT tie. As you tighten Heat Trace Wave Ty, you should begin to notice that heat trace is getting pulled in contact with the pipe. Repeat s qu e ez ing mot ion w ith han dle u nti l hea t tr ace is tight and secure aga ins t pip e.
7. Do not over tighten HTMLT ties. As tie begins to tighten around pipe, you may begin to notice that wave begins to flatten out. Be sure to stop tightening tie prior to wave becoming flat.
8. Once heat trace is in contact with pipe and is tight and secure, move cutting handle upward t o engage cutting action on t he ST4MT and remove excess material. For the ST2MT keep tool engaged and twist counter clockwise (turn to the right) to cut off excess material.
9. Repeat every 12 inches until heat trace is completely attached along the entire length of the pipe.
www.panduit.com
EU Website: www.panduit.com/emea
Email: emeatoolservicecenter@panduit.com
Latin America Website: www.panduit.com
Asia/Pacific Email: cs-ap@panduit.com
U.S.A. Email:
techsupport@panduit.com
Email::cs-la@panduit.com
Page: 2 of 2
U.S.A. Technical Support:
Panduit Europe • EMEA Service Center
Latin America:
Tel: 52 (333) 666-2501 • Fax: 52 (333) 666-2510
Asia/Pacific:
Loading...