For more information about Cisco Compatible Solutions visit
https://marketplace.cisco.com/catalog and search Panduit.
Cabinet Systems
Energy Efficient Data
Center Cabinet and
Containment Systems
Page 2
Using the Panduit Energy
Efficient Data Center Cabinet
System, you can greatly
improve the energy efficiency
of your data center while
confidently increasing
your kW per cabinet density
to increase utilization of your
data center space.
Factors Effecting Efficiency
• Inlet temperatures
• ∆T across heat exchanger
• Capacity utilization
Efficiency Influencers
• Inlet temperatures
• Set points
• Hot air/cold air leakage and recirculation
• Server/CRAH fan speeds
• kW per cabinet density
Enabling Improved Efficiency
• Seal every gap for complete separation
of cooling and exhaust air
• Direct cold air to where it needs to go
• Contain cooling and exhaust air for
maximum cooling capacity efciency
• Monitor to maintain operational and
energy efciency
Reduce Operational Costs, Improve
Capacity Utilization, and Lower
Power Usage Effectiveness (PUE)*
Driven by explosive data processing growth, Data Center Managers face multiple, competing
demands: reducing operational costs, improving energy efciency, and optimizing available
capacity, while sustaining a low total cost of ownership.
To meet these demands while minimizing the risk to service levels, the available data center
space is often underutilized while being overprovisioned with excess power and cooling capacity
regardless of actual IT equipment and space utilization. Today, a typical data center consumes
about 3-5kW per cabinet due to power and cooling concerns, while the available cabinet space
can accommodate 15kW or more per cabinet if managed effectively.
As energy and construction costs continue to rise, over-provisioning and under-utilization are no
longer sustainable. Energy costs related to cooling account for approximately 37% of the overall
data center power consumption
Air
Movement
12%
Cooling
25%
1
and are one of the fastest rising data center operational costs2.
Electricity
Transformer
UPS 10%
Lighting
Etc.,
3%
IT
Equipment
50%
2
visit www.panduit.com/Cabinets
Average data center energy usage allocation
*Power Usage Effectiveness – a metric used to measure how effectively input power is used. It is expressed as a ratio of
power available to power used.
1 Average Data Center Energy Usage Allocation , Lawrence Berkeley National Laboratory 2007
2 451 Research has published 'Highly Energy-Efcient Datacenters in Practice,' October 2012
1
Page 3
Power and cooling capacity remain the top targets for efciency improvement and optimization of
cooling capacity is often the simplest way for data center operators to realize short term savings
and directly impact PUE
Panduit Labs research conrms that raising the supply air temperature in a data center is one of
the most effective means to reduce energy consumption. In addition, higher return temperatures
enable a higher CRAH ∆T across the heat exchangers allowing the cooling system to operate
more efciently.
A key way to realize this energy efciency potential and enable maximum capacity utilization is to
eliminate the mixing of cold and hot air within the cabinet and at the room level delivering higher
return air temperatures to the cooling system and allowing higher room set points.
3
.
1°C rise in chiller water temperature translates into
3-4% cooling system energy savings4.
3 How To Measure Energy Consumption In Your Data Center, Gartner Core RAS Research Note G00205428, 8 September 2010
4 Design Considerations for Datacom Equipment Centers ASHRAE 2005, ISBN 1-931862-94-X. Page 138
visit www.panduit.com/Cabinets
3
Page 4
Complete Hot Air/Cold Air Separation is Critical
$0
$20,000
$40,000
$60,000
$80,000
$100,000
$120,000
Leading Server
Cabinet Competitor
Panduit
Leading Network
Cabinet Competitor
15kW20kW25kW30kW33kW
to Energy Efficiency and Capacity Utilization
Panduit’s Energy Efcient Data Center Cabinet System offers containment, in-cabinet ducting, and improved sealing that optimizes air separation and provide
superior energy savings compared to competitive offerings.
Optimized energy efciency and capacity utilization begin with improved sealing. Even small air leaks within a cabinet will impact data center energy efciency,
regardless of the heat load. Leaks allow hot air recirculation forcing IT equipment inlet fans to work harder and consume more energy, limiting per cabinet power
utilization. Panduit
The graphics below illustrate the impact these leaks have on inlet temperatures. By preventing hot air recirculation, a more consistent inlet temperature gradient
can be realized across the entire front of the cabinet allowing the data center set point to be raised. This results in reduced cooling expense leading to the ability
to increase density power usage per cabinet, and increase available capacity.
®
Net-Access™ Cabinets reduce the air leakage typical in competitive cabinets by as much as 80%.
Improved sealing coupled with containment leads to a $500 annual savings in cooling costs
per cabinet for high density applications at $ .10 per kWh at 15kW per cabinet7.
Inlet Air Temperature Gradients at
Front of Cabinets Comparison
15kW20kW25kW30kW33kW
7
Impact of Net-Access™ Cabinet with
Net-Contain™ Containment System on
Cooling Energy Costs vs. Competition
7
Panduit® Net-Access™ Cabinets
Annual Cooling Energy Costs
Leading Server Cabinet Competitor
Power per Cabinet
Leading Network Cabinet Competitor
With improved cabinet sealing, in-cabinet ducting, containment, and monitoring, the results show you can significantly
increase energy efficiency by raising the set point temperature in the entire data center.
Scan to learn how Panduit delivered
a 27% energy savings with Energy
Efficient Cabinets and Containment.
4
visit www.panduit.com/Cabinets
7 Maximizing Cooling Energy Efciency with Effective Cabinet Sealing, Panduit White Paper RKAT01-WW-ENG, March 2013
Page 5
Increase Density to Optimize Data Center Capacity
Panduit Net-Access™ PDUs, integrated into thermally optimized Net-Access™ Cabinets, enable data center managers to realize higher capacity utilization and
reduced OpEx and CapEx costs.
Typical cabinets are loaded to 5 to 7kW on average, which is often far less than the physical space available within the cabinet resulting in overprovisioning or
the need to build expensive new whitespace.
15kW
Gartner estimates that data center floor
space costs $4,900 per cabinet annually
in CapEx and OpEx (excluding power
and cooling) regardless of
capacity utilization.*
Impact of Increasing Density
kW
kW
5
5
kW
kW
5kW5
5
5kW5
5
kW
kW
5
kW
100 kW
5
kW
$98,000
kW
kW
5
5
kW
kW
5kW5
5
5kW5
5
kW
kW
5
kW
5
kW
5-7kW
15
kW
15
kW
15
kW
15
kW
$4,900 per Cabinet Space
15kW15
kW
100 kW
15
kW
$34,300
Typical Density
High Density
Increasing the density of a 100kW data center can reduce
floor space costs from $98,000 to $34,300 and yield up to
$63,700 in annual savings versus competitive offerings.
visit www.panduit.com/Cabinets
5
Page 6
Seal, Direct, Contain, and Monitor
to Improve your PUE
Panduit Energy Efficient Data Center Cabinet System provides
total separation allowing higher data center set points and
reduced cooling system energy consumption by up to 40%.
Seal every gap for complete separation of
cooling and exhaust air
Net-Access™ Cabinets and Sealing Accessories eliminate leakage through
the cabinet structure preventing re-circulation of hot exhaust air back into
equipment inlets.
Direct cold air to where it needs to go
Net-Access™ In-Cabinet Ducting directs cool air directly into the
intake fans preventing recirculation and reducing inlet air temperature
by as much as 14°C, lowering fan energy consumption6.
Contain cooling and exhaust air for maximum
cooling capacity efficiency
Net-Contain™ Vertical Exhaust Duct and Cold Aisle Containment Systems
eliminate hot air recirculation and mixing with cold air allowing room and
chilled water temperature set points to be raised and PUE to be lowered.
Monitor to maintain operational and energy efficiency
Once the physical infrastructure has been optimized for thermal efciency,
Panduit® SmartZone™ Solutions allow continuous monitoring
of highly accurate, granular PUE measurements in real-time to maintain
thermal efciency in dynamic data center environments.
5
5 Impact of Air Containment Systems, Panduit White Paper #WP-20, June 2012
6 The Use of In-Cabinet Ducting to Improve Inlet Air Temperatures, Panduit White Paper RKAT02--WW-ENG, December 2012
6
visit www.panduit.com/Cabinets
Page 7
Net-Contain™ Vertical
Exhaust Duct
FiberRunner® and
Wyr-Grid® Overhead Cable
Pathway Systems
Sealing
Accessories
Net-Access™
S-Type Cabinets
Panduit® SmartZone™ Solutions
Net-Access™
N-Type Cabinets
The Energy Efcient Data Center Cabinet System can be seamlessly integrated with all elements of the Panduit Converged Infrastructure Solutions, including
Overhead Cable Pathway Systems, High Speed Data Transport (HSDT) Cabling, Grounding and Bonding and Physical Infrastructure Systems.
Software and Hardware
visit www.panduit.com/Cabinets
7
Page 8
Seal Every Gap for Complete Separation
of Cold Intake and Hot Exhaust Air
Cabinet Top Seal
Net-Access
pre-installed 1.5" x 5" or 3.5" x 5" cabinet top
covers and cable protection bezels to eliminate
air leakage from unused cable entry holes.
™
Cabinets are provided with
Complete Air Seal Features Reduce Air Leakage
Throughout the Cabinet Structure by as much as 25%
Net-Access™ Cabinets have been designed to eliminate every
possible air gap other than those needed to mount equipment.
This minimizes by-pass air and recirculation in the cabinet
providing lower inlet temperatures.
7
Tool-Less Blanking Panels
Snap-In Panels optimize cooling efciency
by eliminating bypass airow and hot air
mixing in cabinets.
Scan to learn more about the
Cool Boot® product overview.
8
visit www.panduit.com/Cabinets
Cool Boot® Cabinet Top Air Sealing Fitting
Eliminate air leakage where data cable bundles enter
the cabinet.
Cool Boot® Raised Floor Grommet
Stop bypass air in new or retrot raised oor applications
where power and data cable pass through a cutout into a
rack or cabinet, saving $46 per oor tile cutout annually8.
7 Maximizing Cooling Energy Efciency with Effective Cabinet Sealing, Panduit White Paper RKAT01-WW-ENG, March 2013
8 The Importance of Air Sealing Grommets to Improving Smart Data Center Cooling Efciency, Panduit White Paper #WW-CPWP-04, August 2008
Page 9
Direct Cold Air To Where It Is Needed
Net-Direct™ Inlet Ducts enable optimized containment
by effectively directing airflow to improve
network reliability
• Inlet duct solutions deliver cooling air directly from the
cold aisle into the intake fans of switches
• Inlet ducts are completely passive, requiring no energy
to operate and eliminating a point of failure
• Ensures front to back cooling airow which enables
an effective deployment of network switches with
a Net-Contain
• Inlet ducts enable reduced fan power energy consumption
by allowing lower fan speeds, improving the reliability
of the switch
Available for:Cisco^ Nexus, Catalyst and MDS Switches and Juniper EX Series Switches
™
Cold Aisle Containment deployment
Direct Hot Air To Where It Needs To Exhaust
Net-Direct™ Exhaust Ducts direct hot exhaust air out
of a cabinet away from adjacent devices within
non-contained environments
• Exhaust duct solutions channel hot exhaust air directly to
the hot aisle, away from the cold air inlet of adjacent switches
• Exhaust ducts are completely passive, requiring no energy
to operate and eliminating a point of failure
• Ensures switch exhaust airow is directed to the hot aisle
enabling effective deployment of network switches with a
standard hot aisle/cold aisle conguration
• Exhaust ducts enable reduced fan power energy consumption
by allowing lower fan speeds, improving the reliability
of the switch
Patented9 In-Cabinet Ducting optimizes cooling system efciency by establishing front-to-back airow
patterns through the cabinet.
Available for: Cisco^ Nexus and Catalyst Switches
^Cisco is a registered trademark of Cisco Technology, Inc.
9 Patents #8,035,965, #7,855,885 and #7,595,985 - Network Cabinet with Thermal Air Flow Management System
visit www.panduit.com/Cabinets
9
Page 10
Contain Cold Air or Hot Air to Maximize Cooling
and Space Capacity Utilization
Net-Contain™ Aisle Containment Systems
Deliver Efficient Cooling for High Density Applications
Data Center Managers, challenged to maximize the utilization of available rack-space and cooling capacity, often increase the power density per cabinet.
As cabinet power densities rise, containment architectures are the optimal approach, ensuring uniform cooling air temperature is delivered to equipment in
high density PODs allowing full utilization of available cabinet space and cooling capacity.
Scan to view the Panduit® Net-Contain™ Cold Aisle Containment
Application at EMC’s Durham North Carolina Data Center.
Net-Contain™ Aisle Containment System Benefits
• Data Center Design Versatility – Translucent panels provide built-in provisions for re suppression, environmental monitoring, security devices and other utilities to accommodate all application requirements
• Complete Application Flexibility – System can be used for slab oor or raised oor applications. Modular design enables varying aisle widths and accommodates intermixed Net-Access™ Cabinet widths and in-row coolers to support various network architectures
and heat densities
• Reduced Operational Costs – Sliding doors allow easy accessibility for efcient moves, adds and changes and automatically return to closed position optimizing air containment. Net-Contain™ Components are engineered to seal, minimizing leakage to less than 3%
10
visit www.panduit.com/Cabinets
Page 11
Net-Contain™ Vertical Exhaust Duct
Above Ceiling Hot Air Return
Raised Floor Cold Air Supply*
ColdAisle
ColdAisle
ColdAisle
Hot
Aisle
Hot
Aisle
Data Center Utilizing Panduit ® Net-Contain™Vertical Exhaust Duct
•Uniform distribution of coolair reaching thetop of the cabinet
•Hotexhaust air is isolated and ducted directlyto CRAH units
Passive Cooling for High Density Applications
Net-Contain™ Vertical Exhaust Duct (VED) Systems optimize cooling energy utilization to support high density heat loads to enable 30kw or greater per cabinet.
VEDs passively separate hot exhaust air from cooling air and direct hot exhaust air from active equipment into the Computer Room Air Handler (CRAH)
air return system, allowing higher return air temperature improving CRAH and heat exchanger system efciency up to 40% or more.
Above Ceiling Hot Air Return
Cold
Aisle
Hot
Aisle
Raised Floor Cold Air Supply*
Cold
Aisle
Hot
Aisle
Typical Data Center
•Cool air does not reach the top portions of the cabinets,
making servers in the top rack units vulnerable to overheating
•Hot exhaust air follows complex airow path back to
CRAH units
Above Ceiling Hot Air Return
Cold
Aisle
Cold
Aisle
Hot
Aisle
Raised Floor Cold Air Supply*
Cold
Aisle
Data Center Utilizing Panduit ® Net-Contain™
Vertical Exhaust Duct
•Uniform distribution of cool air reaching the top of the cabinet
Scan to view the Panduit® Net-Contain™ Vertical
•Hot exhaust air is isolated and ducted directly to CRAH units
Exhaust Duct Application at Cisco Allen Data Center.
Net-Contain™ Vertical Exhaust Duct System Benefits
• Flexibility and Versatility – Multiple sizes, heights and adjustable height features allow system to adapt to virtually any data center structure including slab oors or raised oors and facilities with or without drop ceilings
• Speed Deployment and Reduce Installation Cost – Fast, simple assembly and integral ceiling seal reduce installation time by 30% compared to competitive offerings
• Enhance Your Data Center Environment – Vertical Exhaust Duct and Net-Access™ Cabinets with sealed, solid rear doors dampen
equipment noise
• Bond Vertical Exhaust Duct with single connection improves system reliability and protection to personnel – Entire VED is fully electrically bonded to the cabinet requiring no grounding whips for protection of equipment and personnel
visit www.panduit.com/Cabinets
Hot
Aisle
Cold
Aisle
11
Page 12
Monitor to Maintain Operational
and Energy Efficiency
Data center managers are challenged to maintain and manage energy efciency gains in a highly dynamic, virtualized environment in which power consumption,
environmental and capacity utilization variables are constantly changing. Without the ability to monitor these variables in the data center, efciency gains, PUE
reductions and the ability to maximize capacity utilization while maintaining SLA’s will erode over time leading to a higher total cost of ownership.
PUE
2.0
1.5
1.0
OPEX
increases as
PUE Rises
Time
Energy Efficiency Managed
when Monitored with
Panduit
®
SmartZone™ Solutions
Un-Monitored
PUE
Increased
TCO
Panduit® SmartZone™ Solutions
Enable Real-Time Monitoring, Visualization, and Reporting
Panduit® SmartZone™ Solutions offer software, hardware and services that provide management information by monitoring power and environmental
conditions in real time from the entire facility, down into individual cabinets. This capability enables the data center manager to optimize capacity and reduce
CapEx and OpEx costs.
Power and environmental monitoring is only one component of Panduit’s DCIM offering. SmartZone™ Software also enables the tracking, allocation,
and utilization of critical IT assets within your data center.
12
visit www.panduit.com/Cabinets
Page 13
Rack Power Distribution Units (PDUs)
Power and Environmental Hardware
As power densities increase, monitoring of power and environmental information using an intelligent rack power distribution unit (PDU) is critical to
preventing power overload and downtime. Panduit supports power and environmental management through two distinct intelligent PDU families:
SmartZone™ Network-Enabled Rack PDUs that connect directly to the network and SmartZone™ Gateway-Enabled Rack PDUs which connect
via a gateway. SmartZone™ Rack PDUs integrate seamlessly into Panduit® SmartZone™ Software, enabling real-time monitoring of physical
infrastructure power consumption, temperature, and humidity levels for enhanced system reliability and operational efciencies. (See pages 34
and 37 for a list of PDU and sensor part numbers).
Panduit’s comprehensive rack PDU offering is available globally in a variety of power congurations to match typical applications, and can be
congured to meet customer specic needs.
Rack Power Distribution Units (PDUs) – Safely and efciently manage and distribute power to multiple devices through a single
power connector to enhance scalability of network build outs.
Through integration with the SmartZone™ Software Suite, rack PDUs send power and temperature readings to allow:
• Automated documentation and visualization of power utilization and environmental conditions
• Recognition and notication of faults or power disruptions
• Identication of available related capacity
Environmental Sensors – Environmental Sensors are available in wired or wireless options, to measure and trend environmental
conditions such as temperature and humidity levels, at the cabinet level. These intelligent sensors transmit real-time environmental information,
providing notication of exceeded thresholds to quickly identify and resolve issues, identify hot and cold spots in the data center and automate
collection of real-time and accurate environmental information.
These sensors send cabinet-level information to the SmartZone™ Software to allow:
• Automated documentation and visualization of temperature and humidity levels
• Recognition and notication of exceeded temperature thresholds and/or other environmental-specic concerns
• Trending analysis to uncover developing thermal issues that may impact optimal performance and efciency
visit www.panduit.com/Cabinets
13
Page 14
Net-Access™ N-Type Cabinets
Optimum Accessibility and Cable Management for High Density Applications
Net-Access™ N-Type Cabinets are the rst choice for data center managers and systems
integrators specifying high density network, storage and compute applications that
require optimal thermal management and the capacity to manage high cable densities.
Integral cabinet air seal features and integration with passive hot and cold air containment
components drive efcient utilization of cooling capacity and reduce cooling energy
consumption. The Net-Access™ inset frame design efciently manages large quantities of
cables and provides space for unmatched access reducing operational costs. This industry
leading design also maximizes airow and provides easy access to equipment for ongoing
operational efciencies, providing exceptional value in a 800mm (31.5") wide enclosure.
Inset frame provides up to 10%
more space for cable management
and cooling airflow
Industry leading inset cabinet frame posts
create a large area for airow to provide
proper heat dissipation and enable easy
access to equipment, in-cabinet ducting
and cabling, speeding deployments and
reducing operational costs.
Dual hinged doors speed deployments
and moves, adds, and changes up to 30%
IT staff is scarce, downtime is expensive.
For a 120 rack dynamic data center, our
cabinets save you up to an hour a day,
adding up to $18,250 per year savings
for your staff.
Efficiently manage high
cable densities
Modular snap in ngers align with rack
spaces to simplify cable management,
providing proper bend radius control and
organizing cables for faster moves, adds
and changes and installations.
14
visit www.panduit.com/Cabinets
Page 15
Open rail mounting creates more
cable management space and
equipment positioning flexibility
High strength frame eliminates need for
support members between rails, providing
unobstructed space between the frame
and the side panels.
Vertical split side panels
enable fast access to equipment
Innovative vertical split side panels
and optional vertical split hinged side
panels allow fast easy access to end
of row network equipment and cabling,
eliminating time consuming handling.
Innovative Leveling Feet Design
Reduces Cabinet Installation
Time up to 80%
Heavy duty, M14 thread top drive
leveling feet are easily accessed and
allow cabinets to be leveled in less time
than typical leveling feet.
Bond cabinets to the
telecommunications grounding
infrastructure with single connection,
reducing installation time
Entire cabinet is fully electrically
bonded, requiring no grounding whips
to doors or side panels for protection
of equipment and personnel.
visit www.panduit.com/Cabinets
15
Page 16
Net-Access™ S-Type Cabinets
Cost Effective and Versatile Cabinets for all Data Center
Applications and Facilities Designs
Net-Access™ S-Type Cabinets provide data center managers and systems integrators an
unprecedented range of features in a cost effective cabinet platform for server, network,
and pre-congured cabinet applications.
Integral cabinet air seal features and seamless integration with passive hot and cold air containment
components provide efcient utilization of cooling capacity, and contribute to reduced cooling energy
consumption. An innovative frame design maximizes RU utilization saving as much as 15% of the oor
space while safely accommodating equipment loads. Offered in a variety of widths, heights,
and depths, they can be specied for a variety of applications in any facility to meet the diverse
application needs of today’s data centers.
700mm (28") W
600mm (24") W
Large selection of standard cabinet widths, heights, and depths offered in:
• 600mm (24"), 700mm (28"), and 800mm (31.5") Widths
• 1070mm (42") and 1200mm (48") Depths
• 42 RU, 45 RU, and 48 RU Heights
• Black and White Color Option
• Static Load Rating 1,364kg (3,000 lb.)
• Rolling Load Rating 1,136kg (2,500 lb.)
800mm (31.5") W
16
visit www.panduit.com/Cabinets
Page 17
Out-Set Cable Entry Improves
Floor Space Utilization up to 5%
Network cable entry locations are
outside of equipment area, allowing
top 2 RUs to be used, optimizing
cabinet utilization and saving
oor space.
Zero RU E-Rail Vertical Patching Adds
Capacity and Improves Floor Space
Utilization by 10%
Unique Zero RU E-Rail is the industy's
only vertical patching system for 600mm
(24") wide cabinets integrating with
Quick-Net™ Copper and Fiber Cabling
Systems, optimizing cabinet utilization
and saving oor space.
Innovative Leveling Feet Design
Reduces Cabinet Installation
Time by 80%
Heavy duty, M14 thread top drive
leveling feet are easily accessed and
allow cabinets to be leveled in less time
than typical leveling feet.
A 15% savings in floor space means you can build a 420 server POD
with 10 server cabs versus a competitors' cabinet that would require
12 server cabinets to hold equivalent amount of servers.
CapEx savings10 $900/ft2 x 16ft2 = $14,400 capital savings per POD.
10) Cost Model: Dollars per kW plus Dollars per Square Foot of Computer Floor, Uptime 2008
visit www.panduit.com/Cabinets
17
Page 18
Simplify and Accelerate Data Center Deployments
Net-Access™ Cabinets Enable Convergence of Network Equipment
Converged Infrastructure Solutions Add Value
and Reduce Installation Time and Cost
Dynamic rated Net-Access™ N-Type and S-Type Cabinets allow
pre-installation of IT equipment for faster deployments and time to
production. Panduit Converged Infrastructure Solutions are fully tested and
validated physical infrastructures that ensure best practice installations
and optimal system performance. Each conguration accelerates
deployment and promotes rapid upgrades requiring zero recongurations
and downtime.
Fast, Single Part Number Quoting and Procurement
Simply attach pre-priced, robust Converged Infrastructure Solutions to
active gear quotes:
• Reduce quote time
• Procure complete infrastructures with a single part number
• Ensure accurate delivery of all parts to the job site
Maximize the Speed of Deployment and
Overall Execution
Converged Infrastructure Solutions can save up to 80% in deployment time.
• Solutions arrive pre-assembled, kitted, and ready to rack and roll
• Factory installed cable managers, patch cable kits, and cabling
instructions ensure a precise deployment and
professional appearance
Deployment
Fulllment
Design
Plan
Assess
Time to Production
TypicalPanduit Converged
Infrastructure Solutions
Reduced Time to Production
up to 80%
Arrive factory designed, tested,
and validated to improve:
• Assessment time up to 80%
• Planning time up to 80%
• Design time up to 80%
• Fulllment time up to 90%
• Deployment time up to 65%
Refer to Panduit Converged
Infrastructure Solutions For Cisco^
Nexus, UCS, and Catalyst Platforms,
RKCB34--SA-ENG
Converged Infrastructure for
Nexus 7009 "Heavy Copper"
Major Private Cloud Provider
reduced system assembly
time by up to 7 hours per
cabinet, improving cost
and speeding delivery.
^Cisco is a registered trademark of Cisco Technology, Inc.
18
visit www.panduit.com/Cabinets
Page 19
Net-Access™ Cabinet and Thermal Management
Solution for Cisco^ Nexus 7018 Switch
Panduit offers a Net-Access™ Cabinet solution designed to meet the thermal and
operating requirements of the modular, high density Cisco^ Nexus 7018 Switch.
Based on a standard 800mm (31.5") wide Net-Access™ N-Type Cabinet, an
easy to use expansion module provides space to route and manage high
densities of cables. Internal ducting enables front to back cooling air ow
and improved reliability.
Simple conversion for
Standard 800mm N-Type Cabinet
Extension kit enables 800mm
Net-Access™ N-Type Cabinet to be
extended to 1,000mm (40") wide, reducing
shipping costs and simplifying handling.
Passive inlet and exhaust duct
ensures cooling airflow
Prevents recirculation of exhaust air into
the switch, ensuring lower inlet temperature
and reduced fan energy consumption.
Cable management fingers
route, manage and protect
high cable densities
Fingers align with rack spaces to
ensure proper bend radius and superior
management of high densities of I/O
cables, keeping them clear of cold air
ow while maintaining access to power
supplies and fan modules, reducing
operational costs.
Net-Access™ N-Type Cabinet with Cisco^ Nexus 7018
Extension Kit Installed
^Cisco is a registered trademark of Cisco Technology, Inc.
visit www.panduit.com/Cabinets
19
Page 20
Net-Access™ Integral Cabinet Top Cable Routing System
Speed deployments and optimize overhead space utilization
Net-Access™ Cabinets are available with an Integral Cabinet Top Cable Routing System that protects, routes, and manages large
quantities of twisted pair data cables into and out of any Net-Access™ Cabinet. This versatile system is integral to the top of the cabinet
and easily integrates with other cable pathways used throughout the data center, providing up to a 30% reduction in installation costs.
Net-Access
20
™
Integral Cabinet Top Cable Routing System deployed on Net-Access™ Cabinets.
visit www.panduit.com/Cabinets
Page 21
Net-Access™ N-Type Cabinet Specifications
• Welded and assembled steel frame construction
• Easy maintenance powder coat nish
• Adjustable rear equipment rails with continuous positioning,
xed front rails
• Large cable entry/cable access
• Doors include keyed swing handles
• Side panels
• Dual hinge door for maximum accessibility between
adjacent cabinets
• Cabinet supplied with 2 sets of high density cable management
ngers (SN25F)
Net-Access
• Welded and assembled steel frame construction
• Easy maintenance powder coat nish
• Adjustable rear equipment rails with continuous positioning,
xed front rails
• Doors include keyed swing handles
• Side panels include keyed quarter-turn latches
• Large cable entry/cable access
• PDU brackets (SPDUBRK) included
™
S-Type Cabinet Specifications
• Cable entry holes are equipped with plastic sealing plugs
• UL 2416 standard compliant and have been static load tested to
1,360kg (3,000 lb.)
• EIA-310-E compliant
• Rolling Load of 1,136kg (2,500 lb.)
• Cabinet ships assembled, one per pallet
• N-Type Cabinets include hardware kit: #12-24 screws,
or M6 screws and cage nuts
• Casters are supplied separately
• Cable entry holes are equipped with plastic sealing plugs
• UL 2416 standard compliant and have been static load tested to
1,360kg (3,000 lb.)
• EIA-310-E compliant
• Rolling Load of 1,136kg (2,500 lb.)
• Cabinet ships assembled, one per pallet
• S-Type Cabinets include hardware kit: M6 screws, and cage nuts
• Vertical airdams included
• Casters are pre-installed
Net-Access™ Cable Capacity Charts
Top Cap Opening Cable Capacity
AreaCable Capacities
Cat. 6A
Opening SizeIn.
5" x 3.5"
5" x 1.5"
Cabinet Size
(mm)In.
15.6100.76382901272275698
6.542.226343753952398
2
AreaCable Capacities
2
Cm.
Cm.
2
2
0.354"
(8.99mm)
Cat. 6A
0.354"
(8.99mm)
N-Type (Front Side)
800x107043.8282.71782322523576381599
800x120043.8282.71782322523576381599
S-Type (Rear Side)
600x1070
600x1200
700x1070
700x1200
800x107046.3298.41872452673766731688
800x120076.3491.930940444062111102783
18.5119.47598106150269675
30.5196.81231611762484441113
32.4208.91311711862634711181
53.4344.42162823084347771948
Cat. 6A
0.310"
(7.87mm)
Cable Pathways (Per Side)
Cat. 6A
0.310"
(7.87mm)
Cat. 6A
0.297"
(7.54mm)
Cat. 6A
0.297"
(7.54mm)
Cat. 6
0.250"
(6.35mm)
Cat. 6
0.250"
(6.35mm)
Cat. 5e
0.187"
(4.75mm)
Cat. 5e
0.187"
(4.75mm)
visit www.panduit.com/Cabinets
Fiber
(3mm)
Fiber
(3mm)
QuickNet
Cassettes
™
21
Page 22
™
Net-Access
N-Type and S-Type Cabinet
Offering and Availability Overview
Multiple cabinet solutions to meet your project goals – from standard cabinets for quick turnaround to customer congured cabinet
for specic deployments, Net-Access™ N-Type and S-Type Cabinets provide a complete solution to meet customer requirements.
Quick
Turnaround
Net-Access™ N-Type and S-Type Standard Cabinets
™
N-Type and S-Type Standard Congured Cabinets
Net-Access
™
N-Type and S-Type Customer Congured Cabinets
N-Type and S-Type
Customer Congured Cabinets
• Congured to customer specications
• Multiple widths
• Multiple heights
• Multiple depths
• With or without side panels
• Black, white or gray nish
• Door options
• Thermal options
• Equipment rail options
• Top cap options
• Caster options
• Standard accessories pre-installed
to customer specications
Build to
Order
N-Type and S-Type
Standard Cabinets
• Quick turnaround
• 3 widths – 600mm, 700mm, 800mm
• 2 heights – 42 RU, 45 RU
• 2 depths – 1070mm, 1200mm
• With or without side panels
• Black nish
• Standard doors
Net-Access
Options
N-Type and S-Type
Standard Congured Cabinets
• 3 widths – 600mm, 700mm, 800mm
• 3 heights – 42 RU, 45 RU, 48 RU
• 2 depths – 1070mm, 1200mm
• With or without side panels
• Black or white nish
• Door options
• Thermal options
• Equipment rail options
• Top cap options
• Caster options
Net-Access™ N-Type and S-Type Standard Cabinets
42 RUN8212BS8212BS7212BS6212B
45 RUN8512BS8512BS7512BS6512B
With Side Panels
Without Side
Panels
42 RUN8222BS8222BS7222BS6222B
45 RUN8522BS8522BS7522BS6522B
42 RUN8219BS8219BS7219BS6219B
45 RUN8519BS8519BS7519BS6519B
42 RUN8229BS8229BS7229BS6229B
45 RUN8529BS8529BS7529BS6529B
N-Type Standard Components:
• #12-24 tapped rails
• Dual hinge front door/split rear door
• No PDU brackets
• Two sets of ngers
• Solid side panels
• No casters
22
visit www.panduit.com/Cabinets
N-Type WidthS-Type Width
800mm800mm700mm600mm
1070mm depth
1200mm depth
1070mm depth
1200mm depth
S-Type Standard Components:
• Cage nut rails
• Single hinge front door/split rear door
• Caster and PDU brackets included
• Cable management optional
Page 23
Net-Access™ N-Type Standard Configured Cabinets
SeriesWidthHeightDepthSide PanelsColorStandard Options (Select Only One)
N8 = 800mm2 = 42 RU
5 = 45 RU
8 = 48 RU
*Standard side panel. **Includes #12-24 tapped equipment rails. V, Y and YT - Only available for 1200mm deep cabinets. See page 25.
Standard Congurations have 6 characters with only one standard option sufx.
N8212B
™
Net-Access
SeriesWidthHeightDepthSide PanelsColorStandard Options (Select Only One)
S6 = 600mm
7 = 700mm
8 = 800mm
*Standard side panel. P - Only available for 600mm wide S-Type Cabinets. V and V9 - Only available for 1200mm deep cabinets. See page 25.
S-Type Standard Configured Cabinets
2 = 42 RU
5 = 45 RU
8 = 48 RU
1 = 1070mm
2 = 1200mm
1 = 1070mm
2 = 1200mm
2 = 2 Side Panels*
9 = No Side Panel
2 = 2 Side Panels*
9 = No Side Panel
B = Black
W = White
B = Black
W = White
C = Cage Nut Rails
E = Single Hinge Front Door and Cage Nut Rails
S = No Doors**
T = Integral Cabinet Top Cable Routing System**
TC = Integral Cabinet Top Cable Routing System and
Cage Nut Rails
U = Vertical Blanking and Cage Nut Rails
V = VED Ready**
Y = VED Ready and Cage Nut Rails
YT = VED Ready, Cage Nut Rails, and Integral Cabinet Top
Cable Routing System
A = Switch Congured with Front Cable Management
(PDU bracket not included)
A9 = Switch Congured with Front Cable Management and
No Casters
F = Vertical Cable Management Fingers
P = Vertical Patching Equipment Rails
S = No Doors
T = Integral Cabinet Top Cable Routing System
T9 = Integral Cabinet Top Cable Routing System and
No Casters
V = VED Ready
V9 = VED Ready and No Casters
9 = No Casters
Standard Congurations have 6 characters with only one standard option sufx.
S6212B
Net-Access™ N-Type and S-Type Customer Configured Cabinets
Cabinets can be congured to customers' specications. Multiple options are listed below, below, but may not be available for all
congurations. For other possible options please contact your sales person or Customer Service.
• Multiple Widths
• Multiple Heights
• Multiple Depths
• Doors – Single Hinge, Dual Hinge,
Split Doors, or None
• Side Panels – 0, 1, or 2
• Black, White or Gray Finish
• #12-24 Tapped or Cage Nut Rails
• Standard, VED, Integral Cabinet Top Cable
Routing System, or VED and Integral Cabinet
Top Cable Routing System
• Vertical Patching
• Vertical Air Dams
• Cable Management
• Casters
• PDU Brackets
• Combination Locks
visit www.panduit.com/Cabinets
23
Page 24
Net-Access™ N-Type and S-Type Cabinets with
Integral Cabinet Top Cable Routing System
N-Type WidthS-Type Width
800mm800mm700mm600mm
42 RUN8212BTS8212BTS7212BTS6212BT
45 RUN8512BTS8512BTS7512BTS6512BT
48 RUN8812BTS8812BTS7812BTS6812BT
With Side Panels
Without Side
Panels
For other colors replace sufx B (Black) with W (White).
42 RUN8222BTS8222BTS7222BTS6222BT
45 RUN8522BTS8522BTS7522BTS6522BT
48 RUN8822BTS8822BTS7822BTS6822BT
42 RUN8219BTS8219BTS7219BTS6219BT
45 RUN8519BTS8519BTS7519BTS6519BT
48 RUN8819BTS8819BTS7819BTS6819BT
42 RUN8229BTS8229BTS7229BTS6229BT
45 RUN8529BTS8529BTS7529BTS6529BT
48 RUN8829BTS8829BTS7829BTS6829BT
1070mm depth
1200mm depth
1070mm depth
1200mm depth
N-Type Integral Top Cabinet Components:
• 12-24 tapped rails
• Dual hinge front door/split rear door
• No PDU brackets
• Two sets of ngers
• No casters
S-Type Integral Top Cabinet Components:
• Cage nut rails
• Single hinge front door/split rear door
• No cable management
• Caster and PDU brackets included
24
visit www.panduit.com/Cabinets
Page 25
Net-Access™ N-Type and S-Type Vertical Exhaust Duct
(VED) Cabinets (VED Sold Separately)
N-Type WidthS-Type Width
800mm800mm700mm600mm
42 RUN8222BVS8222BVS7222BVS6222BV
With Side Panels
Without Side
Panels
* VED cabinets only available in 1200mm depths.
For other colors replace sufx B (Black) with W (White).
45 RUN8522BVS8522BVS7522BVS6522BV
48 RUN8822BVS8822BVS7822BVS6822BV
42 RUN8229BVS8229BVS7229BVS6229BV
45 RUN8529BVS8529BVS7529BVS6529BV
48 RUN8829BVS8829BVS7829BVS6829BV
1200mm depth
1200mm depth
N-Type VED Cabinet Components:
• #12-24 tapped rails
• Dual hinge front door/solid rear door
• No PDU brackets
• 2 sets of ngers
• VED top cap ready
• Vertical blanking panels with pass-throughs
• Rear oor seals
• No casters
S-Type VED Cabinet Components:
• Cage nut rails
• Single hinge front door/solid single hinge rear door
• No cable management
• VED top cap ready
• Vertical blanking panels
• Front and rear oor seals
• Caster and PDU brackets included
Net-Contain™ Vertical Exhaust Ducts (VEDs)
Part NumberDescription
Net-Contain™ Vertical Exhaust Duct for Net-Access™ N-Type and S-Type Cabinets
C2VED**I1626^^ Net-Contain™ VED **mm width cabinet – 406mm (16") up to 660mm (26") height – ^^ colored.
C2VED**I2638^^ Net-Contain™ VED **mm width cabinet – 660mm (26") up to 965mm (38") height – ^^ colored.
N2EOR1BA1070B1xEnd of row oor seal for 1070mm deep cabinet.
N2EOR1CA1200B1xEnd of row oor seal for 1200mm deep cabinet.
S2EOR1BA1070B1xEnd of row oor seal for 1070mm deep cabinet.
S2EOR1CA1200B1xEnd of row oor seal for 1200mm deep cabinet.
C2FAB06A1200B1xFront or back oor seal for 600mm wide cabinet.
C2FAB07A1200B1xFront or back oor seal for 700mm wide cabinet.
C2FAB08A1200B1xxFront or back oor seal for 800mm wide cabinet.
N*RT
S*RP
visit www.panduit.com/Cabinets
31
Page 32
Net-Direct™ In-Cabinet Ducting
CDE1
CDE2
CNLTD21B2
CNLTD52A2
CNLTD142A3
CNLTD72A3
DIBBC2314S21W
Part NumberDescription
Inlet Ducts
CDE1Net-Direct™ Air Inlet Duct, 1 RU that resides below the switch provides cold aisle airow to Cisco^ 4948,
CDE2Net-Direct
CNLTD21B2Net-Direct
CNLTD52A2Net-Direct
CNLTD142A3Net-Direct
CNLTD72A3Net-Direct
DIBBC2314S21W Net-Direct
DIRLC2214M21W Net-Direct
DIRBB2007S21W Net-Direct
4928, and 4924. Optimized for use in server cabinet applications.
™
Air Inlet Duct, 1 RU that resides in-line and below switch provides cold aisle airow to
Cisco^ Nexus N2K-C2148T-1GE, N2K-C2248TP-1GE, and N2K-C2232PP-10GE fabric extenders and
Cisco^ WS-C4948E-F, WS-C4948E-F-S, and WS-C4948E-F-E. Optimized for use in server
cabinet applications.
™
Air Inlet Duct designed for Cisco^ Catalyst 4900M switch. Consists of one 2 RU inlet duct
and a side duct.
™
Air Inlet Duct designed for Cisco^ Catalyst 6504-E switch. Consists of 2 RU top and 2 RU
bottom inlet ducts and a side duct.
™
Air Inlet Duct designed for Cisco^ Nexus 7009 switch. Consists of 3 RU top and 3 RU bottom
inlet ducts and a side duct.
™
Air Inlet Duct designed for Cisco^ MDS 9506 switch. Consists of 3 RU top and 3 RU bottom
inlet ducts and a side duct.
™
Air Inlet Duct designed for Cisco^ MDS 9513 switch. Consists of 2 RU top and 3 RU bottom
inlet ducts and a side duct.
™
Air Inlet Duct designed for Cisco^ Catalyst 6509-E switch. Consists of 2 RU top and 2 RU
bottom inlet ducts and a side duct.
™
Air Inlet Duct designed for Cisco^ Nexus 7004 switch. Consists of one 2 RU inlet duct and
a side duct.
Exhaust Ducts
DERLCC6509ANet-Direct™ Air Exhaust Duct for Net-Access™ N-Type 1070mm Depth Cabinets.
DERLCC9513ANet-Direct
DERLCC7009ANet-Direct
Designed for Cisco^ 6509 switch.
™
Air Exhaust Duct for Net-Access™ N-Type 1070mm Depth Cabinets.
Designed for Cisco^ 9513 switch.
™
Air Exhaust Duct for Net-Access™ N-Type 1070mm Depth Cabinets.
Designed for Cisco^ 7009 switch.
DERLCC6513ANet-Direct
DIRLC2214M21W
^Cisco is a registered trademark of Cisco Technologies, Inc.
DIRBB2007S21W
Exhaust Ducts
32
visit www.panduit.com/Cabinets
™
Air Exhaust Duct for Net-Access™ N-Type 1070mm Depth Cabinets.
Designed for Cisco^ 6513 switch.
Page 33
Net-Direct™ In-Cabinet 7018 Ducting and 7018 Accessories
Part NumberDescription
7018 Ducting Solution
DIEBCC7018B
DIRLD0425S27W
DIEBCC7018BNet-Direct™ Air Inlet and Exhaust Ducting (blanking panels not included) designed for Cisco^ Nexus
DIRLD0425S27WNet-Direct
DIRLC7018VP51Net-Direct
DIRLC7018VP4248 Net-Direct
7018 switch in a 1000mm wide Net-Access™ N-Type Cabinet.
™
Cisco^ Nexus 7018 switch in a 1000mm wide Net-Access
Cisco^ Nexus 7018 switch in a 1000mm wide Net-Access™ N-Type Cabinet.
Cisco^ Nexus 7018 switch in a 1000mm wide Net-Access™ N-Type Cabinet .
Air Inlet Ducting with left and right side blanking panels for 42/48 RU cabinet designed for
™
Air Inlet Ducting with left and right side blanking panels for 51 RU cabinet designed for
™
Air Inlet Ducting with right side only blanking panel for 42/48RU cabinet designed for
™
N-Type Cabinet .
7018 Cabinet Kits
N1000EXTExtension kit to expand 800mm wide x 1200mm deep Net-Access™ N-Type Cabinet to 1000mm.
For use with cabinets N8229BS, N8529BS, and N8829BS.
7018 Vertical Blanking Panels
DIRLC7018VP51
NVBPA7018BVertical blanking panels with pass-through holes for 42 RU through 48 RU 1000mm wide cabinet.
N-Type Cabinet Split Doors
N2SD1000One set of split doors (used front or back) for 1000mm wide Net-Access™ N-Type Cabinet 42 RU.
™
N-Type Cabinet 45 RU.
DIRLC7018VP4248
N5SD1000One set of split doors (used front or back) for 1000mm wide Net-Access
N8SD1000One set of split doors (used front or back) for 1000mm wide Net-Access™ N-Type Cabinet 48 RU.
NVPDUB7018Net-Access® N-Type PDU Bracket for 1000mm wide cabinets.
N1000EXT
NVBPA7018B
NVPDUB7018
^Cisco is a registered trademark of Cisco Technologies, Inc.
visit www.panduit.com/Cabinets
33
Page 34
SmartZone™ Network-Enabled Rack PDUs North America
Part NumberDescription
P1L2B1L2N16BQA0For aggregate and per outlet power monitoring with switching, 30 A Single Phase, Horizontal Rack PDU, 208V, 12
P1T2B1L2N08ATA0For aggregate and per outlet power monitoring, 30 A Single Phase Horizontal Rack PDU, 208V, 6 IEC C-13 and 2
Q1L1B1F0A24AFA0For aggregate and per outlet power monitoring with switching, 20 A Single Phase Vertical Rack PDU, 208V, 18 IEC
Q1L2B1L2N24AFA0For aggregate and per outlet power monitoring with switching, 30 A Single Phase Vertical Rack PDU, 208V, 18 IEC
Q1L2B1P3N24AFA0For aggregate and per outlet power monitoring with switching, 30 A Three Phase Vertical Rack PDU, 208V, WYE,
Q1L2B2G6N24AFA0For aggregate and per outlet power monitoring with switching, 60 A Three Phase Vertical Rack PDU, 208V, Delta,
Q1N2B1L2N30AHA0For aggregate power monitoring, 30 A Single Phase, Vertical Rack PDU, 208V, 24 IEC C-13 and 6 IEC C-19
Q1N2B1N3N30AHA0 For aggregate power monitoring, 30 A Three Phase Vertical Rack PDU, 208 V, Delta, 24 IEC C-13 and 6 IEC C-19
Q1N2B2W6N30AHA0 For aggregate power monitoring, 60 A Three Phase Vertical Rack PDU, 208V, Delta, 24 IEC C-13, 6 IEC C-19
Q1S2B2C3N24AFA0For aggregate power monitoring with switching, 60 A Single Phase Vertical Rack PDU, 208V, 18 IEC C-13 and 6
Q1S2B2G6N24AFA0For aggregate power monitoring with switching, 60 A Three Phase Vertical Rack PDU, 208V, Delta, 18 IEC C-13
Q1S2B2T6N24AFA0For aggregate power monitoring with switching, 50 A Three Phase Vertical Rack PDU, 208V, Delta, 18 IEC C-13
Q1T2B2C3N24AFA0For aggregate and per outlet power monitoring, 60 A Single Phase Vertical Rack PDU, 208V, 18 IEC C-13 and 6
IEC C-13 and 4 IEC C-19 locking receptacles, and NEMA L6-30P plug
IEC C-19 locking receptacles, and NEMA L6-30P plug.
C-13 and 6 IEC C-19 receptacles, and NEMA L6-20P plug.
C-13 and 6 IEC C-19 locking, and NEMA L6-30P plug.
18 IEC C-13 and 6 IEC C-19 locking receptacles, and NEMA L21-30P plug.
18 IEC C-13 and 6 IEC C-19 locking receptacles, and IEC 60309 - 9H 3P+E blue splash proof plug.
locking receptacles, and NEMA L6-30P plug.
receptacles, and NEMA L15-30P twist lock plug.
receptacles, and IEC 60309-9H 3P+E plug.
IEC C-19 locking receptacles, and IEC 60309 - 9H blue splash proof plug.
and 6 IEC C-19 locking receptacles, and IEC 60309 - 9H 3P+E blue splash proof plug.
and 6 IEC C-19 locking receptacles, and NEMA CS-8365c plug.
IEC C-19 locking receptacles, and IEC 60309 -6H 2P+E plug.
34
visit www.panduit.com/Cabinets
Page 35
SmartZone™ Network-Enabled Rack PDUs Global
Part NumberDescription
P1T1B3H0A08ATA0For aggregate and per outlet power monitoring, 16 A Single Phase Horizontal Rack PDU, 230V 6 IEC C-13 and 2
Q1L2B2P6M24AFA0For aggregate and per outlet power monitoring with switching, 32 A Three Phase Vertical Rack PDU, 230V/400V,
Q1L2B3J2M24AFA0For aggregate and per outlet power monitoring with switching, 32 A Single Phase Vertical Rack PDU, 230V, 18 IEC
Q1N1B3H0A30AHA0 For aggregate power monitoring, 16 A Single Phase Vertical Rack PDU, 230V, 24 IEC C-13 and 6 IEC C-19
Q1N2B2P6M30AHA0 For aggregate power monitoring, 32 A Three Phase Vertical Rack PDU, 230/400V, WYE, 24 IEC C-13 and 6 IEC
Q1N2B2Q0A30AHA0 For aggregate power monitoring, 16 A Three Phase Vertical Rack PDU, 230/400V, WYE, 24 IEC C-13 and 6 IEC
Q1N2B3J2M30AHA0 For aggregate power monitoring, 32 A Single Phase Vertical Rack PDU, 230V, 24 IEC C-13 and 6 IEC C-19
Q1S2B2P6M24AFA0For aggregate power monitoring with switching, 32 A Three Phase Vertical Rack PDU, 230V/400, WYE, 18 IEC
Q1S2B2Q0A24AFA0For aggregate power monitoring with switching, 16 A Three Phase Vertical Rack PDU, 230V/400V, WYE, 18 IEC
Q1S2B3J2M24AFA0For aggregate power monitoring with switching, 32 A Single Phase Vertical Rack PDU, 230V, WYE, 18 IEC C-13
Q1T1B3H0A24AFA0For aggregate and per outlet power monitoring, 16 A Single Phase Vertical Rack PDU, 230V, WYE, 18 IEC C-13
IEC C-19 locking receptacles, and IEC 60309-6H 2P+E plug.
WYE 18 IEC C-13 and 6 IEC C-19 locking receptacles, and IEC-60309-6H 3P+N+E plug.
C-13 and 6 IEC C-19 locking receptacles, and IEC-60309-6H 2P+E plug.
receptacles, and IEC 60309-6H 2P+E plug.
C-19 receptacles, and IEC 60309-6H 3P+N+E plug.
C-19 receptacles, and IEC 60309-6H 3P+N+E plug.
receptacles, and IEC 60309-6H 2P+E plug.
C-13 and 6 IEC C-19 locking receptacles, and IEC 60309 -6H 3P+N+E plug.
C-13 and 6 IEC C-19 locking receptacles, and IEC-60309-6H 3P+N+E plug.
and 6 IEC C-19 locking receptacles, and IEC 60309 -6H 2P+E plug.
and 6 IEC C-19 locking receptacles, and IEC 60309-6H 2P+E plug.
visit www.panduit.com/Cabinets
35
Page 36
SmartZone™ Gateway-Enabled Rack PDUs North America
Part NumberDescription
GM-A0252BLFor aggregate power monitoring, vertical, 30 A, single phase, 208V, 24 IEC C-13 and 6 IEC C-19 receptacles,
GM-A0255BLFor aggregate power monitoring, vertical, 30 A, three phase, 208V, delta, 24 IEC C-13 and 6 IEC C-19 receptacles,
GM-A0257BLFor aggregate power monitoring, vertical, 60 A, single phase, 208V, 24 IEC C-13 and 6 IEC C-19 receptacles, IEC
GMPO-A0276BLFor aggregate and per outlet power monitoring, horizontal 1 RU, 30 A, single phase, 208V, 6 IEC C-13 and 2 IEC
GMPO-A0277BLFor aggregate and per outlet power monitoring, vertical, 60 A, single phase, 208V, 18 IEC C-13 and 6 IEC C-19
GMS-A0280BLFor aggregate power monitoring with switching, vertical, 60 A, three phase, 208V, delta, 18 IEC C-13 and 6 IEC
GMS-A0283BLFor aggregate power monitoring with switching, vertical, 60 A, single phase, 208V, 18 IEC C-13 and 6 IEC C-19
GMS-A0284BLFor aggregate power monitoring with switching, vertical, 50 A, three phase, 208V, delta, 18 IEC C-13 and 6 IEC
GMSPO-A0286BLFor aggregate and per outlet power monitoring with switching, horizontal 1 RU, 30 A, single phase, 208V, 12 IEC
GMSPO-A0288BLFor aggregate and per outlet power monitoring with switching, vertical, 60 A three phase, 208V, delta, 18 IEC C-13
GMSPO-A0289BLFor aggregate and per outlet power monitoring with switching, vertical, 30 A, three phase, 208V, WYE, 18 IEC C-13
GMSPO-A0291BLFor aggregate and per outlet power monitoring with switching, vertical, 30 A, single phase, 208V, 18 IEC C-13 and
GMSPO-A0292BLFor aggregate and per outlet power monitoring with switching, vertical, 20 A single phase, 208V, 18 IEC C-13 and
NEMA L6-30P plug, LCD display, with serial port for connection to Gateway.
NEMA L15-30P plug, LCD display, with serial port for connection to Gateway.
60309 - 6H 2P+E, LCD display, with serial port for connection to Gateway.
C-19 locking receptacles, NEMA L6-30P plug, LCD display, with serial port for connection to Gateway.
receptacles, IEC 60309-6H 2P+E plug, LCD display, with serial port for connection to Gateway.
C-19 locking receptacles, IEC 60309 - 6H 3P+E, LCD display, with serial port for connection to Gateway.
receptacles, IEC 60309-6H 2P+E plug, LCD display, with serial port for connection to Gateway.
C-19 locking receptacles, NEMA CS-8365C plug, LCD display, with serial port for connection to Gateway.
C-13 and 4 IEC C-19 locking receptacles, NEMA L6-30P plug, LCD display, with serial port for connection
to Gateway.
and 6 IEC C-19 locking receptacles, IEC-60309-9H 3P+E plug, with serial port for connection to Gateway.
and 6 IEC C-19 locking receptacles, NEMA L21-30P plug, with serial port for connection to Gateway.
6 IEC C-19 locking, NEMA L6-30P plug, with serial port for connection to Gateway.
6 IEC C-19 receptacles, NEMA L6-20P plug, LCD display, with serial port for connection to Gateway.
36
visit www.panduit.com/Cabinets
Page 37
SmartZone™ Gateway-Enabled Rack PDUs Global
Part NumberDescription
GM-A0258BLFor aggregate power monitoring, vertical, 32 A, three phase, 230V/400V, WYE, 24 IEC C-13 and 6 IEC C-19 recep-
GM-A0259BLFor aggregate power monitoring, vertical, 16 A, three phase, 230/400V, WYE 24 IEC C-13 and 6 IEC C-19
GM-A0263BLFor aggregate power monitoring, vertical, 16 A, single phase, 230V, 24 IEC C-13 and 6 IEC C-19 receptacles, IEC
GM-A0265BLFor aggregate power monitoring, vertical, 32 A, single phase, 230V, 24 IEC C-13 and 6 IEC C-19 receptacles, IEC
GMPO-A0275BLFor aggregate and per outlet power monitoring, horizontal 1 RU, 16 A, single phase, 230V, 6 IEC C-13 and 2 IEC
GMPO-A0278BLFor aggregate and per outlet power monitoring, vertical, 16 A, three phase, 230V, 18 IEC C-13 and 6 IEC C-19
GMS-A0281BLFor aggregate power monitoring with switching, vertical, 32 A, single phase, 230V, 18 IEC C-13 and 6 IEC C-19
GMS-A0282BLFor aggregate power monitoring with switching, vertical, 16 A, three phase, 230V/400V, WYE 18 IEC C-13 and 6
GMS-A0285BLFor aggregate power monitoring with switching, vertical, 32 A, three phase, 230V/400, WYE 18 IEC C-13 and 6 IEC
GMSPO-A0287BLFor aggregate and per outlet power monitoring with switching, vertical, 32 A, three phase, 230V/400V, WYE 18 IEC
GMSPO-A0290BLFor aggregate and per outlet power monitoring with switching, vertical, 32 A, single phase, 230V, 18 IEC C-13 and
tacles, IEC 60309 - 6H 3P+N+E plug, LCD display, with serial port for connection to Gateway.
receptacles, IEC 60309-6H 3P+N+E plug, LCD display, with Serial port for connection to Gateway.
60309-6H 2P+E plug, LCD display, with Serial port for connection to Gateway.
60309 - 6H 2P+E plug, LCD display, with Serial port for connection to Gateway.
C-19 locking receptacles, IEC 60309 - 6H 2P+E plug, LCD display, with serial port for connection to Gateway.
locking receptacles, IEC 60309-6H 2P+E plug, LCD display, with serial port for connection to Gateway.
locking receptacles, IEC 60309-6H 2P+E plug, LCD display, with serial port for connection to Gateway.
IEC C-19 locking receptacles, IEC-60309-6H 3P+N+E plug, LCD display, with serial port for connection to Gateway.
C-19 locking receptacles, IEC 60309-6H 3P+N+E plug, LCD display, with serial port for connection to Gateway.
C-13 and 6 IEC C-19 locking receptacles, IEC-60309-6H 3P+N+E plug, with serial port for connection to Gateway.
6 IEC C-19 locking receptacles, IEC-60309-6H 2P+E plug, with serial port for connection to Gateway.
Part NumberDescription
ZEDIC05-01Digital input sensor for use with voltage-free contacts
ZEDL05-01Door sensor (micro switch type)
ZEDL05-02Door contact sensor (magnetic type)
ZEDL05-01
ZEDL05-02
ZETHL-13
ZETHL-11
ZEPIR-04
ZEPIR-04PIR sensor
ZESMA05-01Smoke detector
ZETHL-11Combined temperature and humidity sensor
ZETHL-13External temperature sensor
visit www.panduit.com/Cabinets
39
Page 40
Blanking Panels and Blanking Shade
Part NumberDescription
TLBP1
Tool-Less Blanking Panels
TLBP1S-V19" (483mm) width for 3/8" cage nut holes (may be used with or without cage nuts installed). 1 RU.
TLBP2
TLBPBPT1S
FLBSIMS
TLBP2S-V19" (483mm) width for 3/8" cage nut holes (may be used with or without cage nuts installed). 2 RU.
TLBP1R-V19" (483mm) width for tapped rails. 1 RU.
TLBP2R-V19" (483mm) width for tapped rails. 2 RU.
Pass-Through Blanking Panels
TLBPBPT1S19" (483mm) width for 3/8" cage nut holes (may be used with or without cage nuts installed).
1 RU, with pass-through areas.
Blanking Shade
FLBSIMSFull-length blanking shade blanks out 1-51 consecutive rack units on standard 19.00" (482.6mm) wide
vertical mounting rails; black.
40
visit www.panduit.com/Cabinets
Page 41
Sealing Accessories
Part NumberDescription
CTGN1X5
CTGN3X5
CTGN6X6
CTCN1X5
CTCN3X5
CTNBZL6X6
Cool Boot ® Cabinet Top Air Sealing Fitting
CTGN1X5Used to seal off 1" x 5" cabinet top openings when cables are routed through the top of a cabinet. Airtight
CTGN3X5Used to seal off 3" x 5" cabinet top openings when cables are routed through the top of a cabinet. Airtight
CTGN6X6Used to seal off 6.5" x 6.5" cabinet top openings when cables are routed through the top of a cabinet.
Cabinet Top Cover and Cable Protection Bezel
CTCN1X5
CTCN3X5
CTNBZL6X6Used to provide a protective edge for cables routed through the 6.5" x 6.5" cabinet top openings after
Blanking Foam Strips
BFS100X2000Adhesive-backed blanking foam strips conform to minimize gaps and prevent bypass air within network
Cool Boot® Raised Floor Air Sealing Grommet
™
fabric and Ultra-Cinch
of network equipment and reduce energy costs. For use with 600mm wide Net-Access
fabric and Ultra-Cinch
of network equipment and reduce energy costs. For use with 700mm, 800mm, and 1000mm wide
Net-Access™ Cabinets.
Airtight fabric and Ultra-Cinch
cooling of network equipment and reduce energy costs. For use with 600mm, 700mm, 800mm, and
1000mm wide Net-Access™ Cabinets.
Used to seal off 1.5" x 5" cabinet top openings. Can also be used to add the CTGN1X5 to openings where the
snap-on cover has been removed. For use with Net-Access™ Cabinets.
Used to seal off 3.5" x 5" cabinet top openings. Can also be used to add the CTGN3X5 to openings where the
snap-on cover has been removed. For use with Net-Access™ Cabinets.
knock-outs are removed. Can also be used to add the CTGN6X6 to openings where knock-out has been
removed. For use with Net-Access
cabinets. Removable and repositionable acrylic-based adhesive is aggressive to provide suitable strength,
however, will not leave residue on equipment. 4.0" x 100" roll perforated 1.0" in width and 20.0" in length.
Tie close top of fabric, minimizing hot air bypass around cables to improve cooling
™
Tie close top of fabric, minimizing hot air bypass around cables to improve cooling
™
Tie close top of fabric, minimizing hot air bypass around cables to improve
™
Cabinets.
™
Cabinets.
BFS100X2000
RFG12X
RFG12X4SMYOverall size of 12" x 4" (304.8mm x 101.6mm) allows for 10.2" x 2.2" (259.1mm x 55.9mm) maximum capac-
ity. Surface mount product can be installed over any opening less than 10.2” x 2.2” (259.1mm x 55.9mm).
RFG12X4YOverall size of 12" x 4" (304.8mm x 101.6mm) allows for 10.2" x 2.2" (259.1mm x 55.9mm) capacity.
Includes exible sub-grommet to prevent damage to cable from sharp edges of cut oor tile.
visit www.panduit.com/Cabinets
41
Page 42
Telecommunications Grounding Accessories
Part NumberDescription
CNBK
RGCBNJ660P22
RGS134-1Y
CNBKGreen bonding cage nut, includes 50 #12-24 bonding cage nuts (.06 – .11 thick panel) and
RGCBNJ660P22Mesh common bonding network (MCBN) jumper kit; #6 AWG (16mm
50 #12-24 x 1/2" bonding screws with #2 Phillips/slotted combo hex head (use 5/16" or 8mm socket).
lug on grounding strip stide; provided with .16oz. (5cc) of antioxidant, two each #12-24 x 1/2", M6 x
12mm, #10-32 x 1/2" and M5 x 12mm thread-forming screws and a copper compression HTAP for
connecting to the SBG (MCBN) in sizes ranging from #6-#2 AWG (16 – 25mm2).
with .16oz (5cc) of antioxidant, one grounding sticker, three each #12-24 x 1/2", M6 x 12mm,
#10-32 x 1/2" and M5 x 12mm thread-forming screws.
provided with .16oz (5cc) of antioxidant, one grounding sticker, three cage nut bonding studs,
eight #12-24 bonding nuts and three stip clips.
ESD protection sticker, 16oz. (5cc) of antioxidant, two cage nut bonding studs and two #12-24
bonding nuts.
provided with two each #12-24 x 1/2" and M6 x 12mm thread-forming screws.
with twenty #12-24 x 1/2" hex head screws installed; mounting hole sets have 5/8" (15.9mm) spacing;
provided with two cage nut bonding studs and four #12-24 bonding nuts.
1
1
1
42
visit www.panduit.com/Cabinets
Page 43
Energy Efficient Data Center Cabinet System
A Part of Panduit’s Converged Infrastructure Solutions
Panduit Converged Infrastructure Solutions embody the next wave of systems integration and risk management by aligning and harmonizing
critical systems to support the delivery of secure, energy-efcient, always-on, real-time data and services. Energy Efcient Cabinet Systems
are one of the key pillars of the Panduit Converged Infrastructure Solutions portfolio that include:
®
Data Center Infrastructure Management (DCIM) — Panduit
end-to-end physical to logical view of your data center and extended enterprise. SmartZone
data center’s space, power, and capacity planning through 10% OpEx savings in energy costs, 75% faster moves, adds, and changes (MACs),
and 80% faster mean time to repair (MTTR).
SmartZone™ Solutions including hardware, software, and services that provide
™
Solutions enable effective optimization of your
Data Center Advisory Services — Panduit Data Center Advisory Services provide a full range of physical infrastructure layer services
to help you assess, design, and maintain resilient, sustainable solutions that deliver operational exibility to reduce costs by up to 20%,
and meet future requirements.
High Speed Data Transport (HSDT) Copper and Fiber Cabling Systems — Panduit HSDT Solutions are both protocol and media
agnostic, delivering maximum exibility during planning, designing, commissioning, and operation of the data center. Our HSDT
Solutions enable advanced network architectures such as 10/40/100 Gig Ethernet LANs and 8/16/32 Gig Fibre Channel SANs and
can provide a 10% improvement in network throughput.
Converged Infrastructures — Panduit helps reduce deployment times up to 65% and mitigates the risk of adopting
new technologies with reliable and robust Converged Infrastructures. Panduit utilizes optimized reference designs collaboratively
engineered with our partners, to enhance the physical infrastructure of their technology platforms and seamlessly integrate physical
and logical systems.
Physical Infrastructure Foundation — Critical to the deployment of our Data Center solution is the physical infrastructure
foundation in the data center, which includes such items as:
Pathways: Provide the best method to route and manage the growing amount of data and power cabling while
ensuring high levels of network performance
Zone Cabling: Serves as a main distribution point for a particular zone, increasing network exibility, manageability,
accessibility, and efciency
Bonding and Grounding: Provides a high quality, visually veriable and dedicated grounding path to maintain
system performance, improve network reliability, and protect network equipment and personnel
Identication and Labeling: Enhance the appearance of installations by presenting a clear and efcient way
to label according to TIA/EIA-606-A standards