© Panduit Corp. 2006
Refer to the installation and configuration guidelines provided by the manufacturer of the wireless
access point to determine the optimum enclosure installation location and antenna configuration.
PANZONE Wireless Access Point In Ceiling
Brackets
Part Numbers:PZWIFICB,PZWIFIDCB,PZW2X2CB,PZW2X2DCB
INSTRUCTIONS CM316B
Please read these instructions in their entirety prior to installing the enclosu re.
PANDUIT Part #: PZWIFICB - PANZONE Wireless Access
Point In Ceiling Bracket Kit
See Step 2 & 4 for installation instructions See Step 4 for installation instructions
PANDUIT Part #: PZWIFIDCB - PANZONE Wireless
Access Point In Ceiling Bracket Kit
PANDUIT Part #: PZW2X2CB - PANZONE Wireless Access Point
In Ceiling 2’x 2’ Bracket Kit
PANDUIT Part #: PZW2X2DCB - P
Point In Ceiling 2’x 2’ Bracket Kit
ANZONE Wireless Access
See Step 2-3 for installation instructions
Step 1: Knockout Removal
1.1 Remove knockouts in desired cable entry location:
For Conduit - Remove knockout “A”, “B” or “C”. This double
knockout accommodates either 1/2” or 3/4” conduit.
Without Conduit - Remove knockout “A” or “B”. Remove the
1/2” diameter opening.
FOR TECHNICAL SUPPORT www.panduit.com/resources/install_maintain.asp
See Step 4 for installation instructions
Page 1 of 4

INSTRUCTIONS CM316B
Step 2: Install Ceiling Mount Brackets
2.1 Install Ceiling Mount Brackets against side wall of the enclosure with the flanged edge facing away from the enclosure.
(see figure 2) The top of the flanged edge should be even with
the enclosure door.
2.2 Fasten the bracket to the base of the enclosure using four of
the supplied #6-32 Screws.
2.3 Repeat steps for remaining 3 Ceiling Mount Brackets.
PZWIFIDCB ONLY
Step 3: Prepare Ceiling Tile
3.1 When the enclosure will be mounted in a suspended ceiling, a
square hole that is approximately 12 7/8" x 14 5/8" must be
cut in the ceiling tile.
3.2 It is important that the hole be no smaller than 12 5/8" x
14 3/8" and no larger than 13 1/8" x 14 7/8". This will ease
installation and prevent visible gaps around the enclosure
once installed.
Note:The bottom edges of the assembled enclosure brackets can
be used as a guide to trace the square hole size onto the ceiling tile.
PZWIFICB ONLY
Step 4: Prepare Ceiling Tile
4.1 When the enclosure will be mounted in a suspended ceiling, a
square hole that is approximately 12 1/2" x 12 1/2" must be
cut in the ceiling tile.
4.2 It is important that the hole be no smaller than 12 1/4" x 12 1/
4" and no larger than 12 3/4" x 12 3/4". This will ease installation and prevent visible gaps around the enclosure once
installed.
Note:The bottom edges of the assembled enclosure brackets can
be used as a guide to trace the square hole size onto the ceiling tile.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 2 of 4

5.3
3/8” dia hanger wire
mounting holes
(8 places)
3/8” dia hanger wire
mounting holes
(4 places)
PZWIFICB
PZW2X2CB
Step 5: Installing Enclosure in Bracket
5.3
3/8” dia hanger wire
mounting holes
(8 places)
3/8” dia hanger wire
mounting holes
(4 places)
PZWIFIDCB
PZW2X2DCB
5.1 Insert enclosure into bracket as shown align hinges with the
hinge slots in bracket.
5.2 Secure the four sides of the enclosure to the bracket with (4)
#6-32 screws provided with the bracket as shown.
5.3 Hanger wire should be used to hang the enclosure
within a suspended ceiling. Important: Verify hanger
wire meets local building code. Weight of the
enclosure, mounting brackets, and equipment does not
exceed 20 lbs. The enclosure is rated to hold up to
10 lbs of equipment.
5.4 Observe how the hanger wire used to hold the ceiling
support grid is secured to the building structure.
5.5 Remove one tile adjacent to the tile the enclosure will
be mounted in.
5.6 Secure four pieces of hanger wire (not included) to the
building structure. The hanger wire length will be
determined by the installer based on the building
structure dimensions above the suspended ceiling.
Extend the length of the hanger wire beyond the
surface of the ceiling by at least 6".
5.7 Add the cut ceiling tile back to the ceiling support grid.
5.8 Pull one of the four pieces of hanger wire to one corner
of the square opening in the ceiling tile. Pre-bend the
hanger wire at a 90° angle approximately 2 1/2" abo ve
the surface of the ceiling tile. Repeat this step for the
remaining 3 hanger wires measuring to the three
remaining corners of the square opening.
5.9 Insert the enclosure into the cut ceiling tile opening.
5.10 While holding the enclosure flush with the surface of
the ceiling tile, route the hanger wire throu gh one of the
eight 3/8" dia hanger wire mounting holes and bend u p.
Pull the wire upward until the enclosure is flush with the
5.1 1 Visually inspect the edges of the enclosure to verify no
5.12 To secure the enclosure, wrap each hanger wire tightly
5.13 Replace the adjacent ceiling tile.
ceiling tile. Repeat this step using the three remaining
hanger wires to secure the three remaining corners of
the enclosure.
gaps exist between the mounting brackets and surface
of the ceiling tile. If gaps exist, pull the hanger wire
upward until the enclosure is tight against the ceiling
tile.
around itself a minimum of three times.
For Technical Support: www.panduit.com/resources/install_maintain.asp
INSTRUCTIONS CM316B
Page 3 of 4

INSTRUCTIONS CM316B
PZWIFIE
PZWIFIEW
PZWIFIELW
PZWIFIE with PZW2X2CB
PZWIFIEW with PZW2X2CB
PZWIFIE with PZWIFICB
PZWIFIEW with PZWIFICB
PZWIFIELW with PZWIFICB
Designed for Cisco Aironet™ 1200 Series (excludes Cisco Aironet™ 1232 and 1242 Acess Points )
PZWIFIED,
PZWIFIEN,
PZWIFIENA
PZWIFIED with PZW2X2DCB
PZWIFIED with PZWIFIDCB
Designed for Cisco Aironet™ 1232 and 1242 Access Points
Designed for Cisco Aironet™ 1130 Series
Designed for Cisco Aironet™ 1000 Series
PZWIFIELW with PZW2X2CB
For instuctions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
www.panduit.com
Page 4 of 4
E-mail:
cs@panduit.com
Fax:
(708)444-6448