Panduit PZNWE14 Installation Manual

Page 1
© Panduit Corp. 2008
Contents:
1 - Enclosure 1 - Aluminum Mounting Plate 1 - Mounting Template 1 - Hardware Kit
- (2) Adhesive Mounting Clips
- (1) RTV Silicone Sealant Pack
- (6) # 10-32 x 3/8” Screws
- (2) # 6-32 x 1/4” Screws
- (1) UTP or STP M
- (1) 2 Position Surface Mount Box
- (2) UTP or STP 2’ CAT 6 Patch Cord
- (4) Cable Ties
INI-COM TX6 Plus Jack Module

PANZONE NEMA 4X/IP66 Rated Wireless Access Point Enclosure

Part Numbers:PZNWE14,PZNWE14S
INSTRUCTIONS CM332A

PZNWE14 (Shown Open)

Note: Installer should use the following assembly instructions as a guideline to mount desired Wireless Access Point (WAP), External Antennas, and Powering
Device. In the following instructions a C WAP are shown being installed, however any similar sized WAP with external antennas can be installed in a similar manner.
ISCO AIRONET AIR-AP1242AG-x-K9, CISCO AIRONET AIR-AP1252A6-x-K9, and a CISCO AIRONET AIR-AP1310G-x-K9

Assembly Instructions:

1. Use the supplied Mounting Template as a guide to locate the hole locations required on the Aluminum Mounting Plate. The supplied
Aluminum Mounting Plate
Supplied Mounting Template
FOR TECHNICAL SUPPORT www.panduit.com/resources/install_maintain.asp
Drill the mounting plate per the supplied template choosing the appropriate assembly scenario
Page 1 of 10
Page 2
INSTRUCTIONS CM332A
Cisco Wireless Series
Steps
1240 Series
1250 Series
Steps 6 -10
Steps 11-15
2. Attach the Mounting Plate to the enclosure to with the supplied #10-32 x 3/8” screws and washers.
Supplied # 10-32 x 3/8” screw and flat washers

Installing Cisco 1240 and 1250 Series wireless access point

Mounting plate drilled per the supplied template
3. Install a straight liquid tight conduit connector in line with the electrical box mount location
4. For incoming cables install a cord grip such as PANDUIT part number PZNF2 or conduit fitting on the bottom surface of the enclosure in line with supplied
surface mount box. Apply RTV silicone to the surface of the collar, of the ecollar and of the cord grip O-ring to maintain a liquid tight seal.
Cord Grip Hex Nut
Conduit Connector Locknut
Bottom surface of installed enclosure
Liquid tight straight thru cord grip for data cable / POE entry
Bulkhead antenna extender CISCO part number AIR-ACC2537-060, for external antenna mounting.
Note:
-Cisco 1240 Series requires up to four antennas.
-Cisco 1250 Series requires up to six antennas
-Cisco 1300 Series requires up to two antennas
Bulkhead mount hex nuts
5. Install a bulkhead antenna extender, CISCO part number AIR-ACC2537-060 to the bottom
surface of the enclosure as shown. Apply RTV silicone to the surface of the collar of the extender to maintain a liquid tight seal. The desired mount hole diameter is.53”.
Note: Identify the Cisco Wireless Series you are currently working with before continuing on to the next page.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 2 of 10
NEMA 4X RATED FITTINGS CABLE DIA. (INCHES)
PZNF1 PZNF2 PZNF3
.115" - .250" .230" - .395" .170" - .450"
Page 3
INSTRUCTIONS CM332A
Cisco 1240 Series Instructions
6. Fasten a 2” x 4” electrical box in line with the incoming conduit fitting with the supplied #10-32 thread cutting screws. Fasten the WAP
mounting plate to the aluminum mount plate with the supplied #10-32 thread cutting screws,.
2 Position Surface Mounting Box Base
Installed Aluminum Mounting Plate
CISCO WAP Mounting Plate
2” x 4” x 1 7/8” deep electrical box.
#10-32 Pan Head Thread Cutting Screws
7. Fasten the supplied 2 position surface mount box base the wall of the enclosure as shown using the double sided tape. Alternatively, the
base can be mounted to the aluminum back plate with the supplied (2) #6-32 flat head thread cutting screws.
8. Run the network cable into the enclosure and terminate to the MINI-COM TX6 jack module installed in the surface mount box. Insert one
end of the 2’ patch cord supplied into the opposite end of the jack module and route to the wireless access point RJ45 port as shown.
2’ Patch cord supplied
2 position surface mount box
C
ISCO AP1242AG shown
Incoming network cable
For Technical Support: www.panduit.com/resources/install_maintain.asp
Wireless access point ethernet port
Page 3 of 10
Page 4
INSTRUCTIONS CM332A
9. The CISCO AC power adapter supplied with the wireless access point can be located as shown, providing power to the wireless access
point. Slack the excess cable beside the adapter as shown.
10. Attach the required external antennas to the bulkhead fittings installed on the bottom surface of the enclosure. Wrap the excess
bulkhead cable slack around the mounted wireless access point.
2 Position surface mount box base
2’ Patch Cord supplied
Slack excess power cable beside the adapter as shown
Incoming data/POE cable
2.4 Ghz dipole antenna C
ISCO
AIR-ANT4941 locations shown
For Technical Support: www.panduit.com/resources/install_maintain.asp
C
ISCO AP1242AG shown
5.0 Ghz dipole antenna C
ISCO
AIR-ANT5135D-R locations shown
Page 4 of 10
Page 5
INSTRUCTIONS CM332A
Cisco 1250 Series Instructions
11. Fasten a 2” x 4” electrical box in line with the incoming conduit fitting with the supplied #10-32 thread cutting screws. Fasten the WAP
mounting plate to the aluminum mount plate with the supplied #10-32 thread cutting screws,.
2 Position Surface Mounting Box Base
CISCO WAP Mounting Plate
Installed Aluminum
Mounting Plate
2” x 4” x 1 7/8” deep electrical box.
#10-32 Pan Head Thread Cutting Screws
12. Fasten the supplied 2 position surface mount box base the wall of the enclosure as shown using the double sided tape. Alternatively, the
base can be mounted to the aluminum back plate with the supplied (2) #6-32 flat head thread cutting screws.
13. Run the network cable into the enclosure and terminate to the MINI-COM TX6 jack module installed in the surface mount box. Insert one
end of the 2’ patch cord supplied into the opposite end of the jack module and route to the wireless access point RJ45 port as shown.
2’ Patch cord supplied
2 position surface mount box
ISCO AP1252AG shown
C
Incoming network cable
For Technical Support: www.panduit.com/resources/install_maintain.asp
Wireless access point ethernet port
Page 5 of 10
Page 6
INSTRUCTIONS CM332A
L
o
o
p
a
n
t
e
n
n
a
w
i
r
e
s
l
a
c
k
a
r
o
u
n
d
t
h
e
w
i
r
e
l
e
s
s
a
c
c
e
s
s
p
o
i
n
t
.
14. The CISCO AC power adapter supplied with the wireless access point can be located as shown, providing power to the wireless access
point. Slack the excess cable beside the adapter as shown.
15. Attach the required external antennas to the bulkhead fittings installed on the bottom surface of the enclosure. Wrap the excess
bulkhead cable slack around the mounted wireless access point.
(A) 2.4 Ghz dipole antenna CISCO
2 Position surface mount box base
Slack excess power cable beside the adapter as shown
AIR-ANT4941 locations shown
2’ Patch Cord supplied
A
Incoming data/POE cable
A
A
B
A
A
A
B
B
B
B
B
ISCO AP1242AG shown
C
(A) 2.4 Ghz dipole antenna C AIR-ANT4941 locations shown
For Technical Support: www.panduit.com/resources/install_maintain.asp
ISCO
Page 6 of 10
(B) 5.0 Ghz dipole antenna C AIR-ANT5135D-R locations shown
ISCO
Page 7
INSTRUCTIONS CM332A

Installing Cisco 1310 Series wireless access point

16. Install a straight liquid tight conduit connector in line with the electrical box mount location.
17. For incoming cables install a cord grip such as PANDUIT part number PZNF2 or conduit fitting on the bottom surface of the enclosure for
the data cable entry. Apply RTV silicone to the surface of the collar of the cord grip to maintain a liquid tight seal.
Conduit Connector Locknut
Cord Grip Hex Nut
Bulkhead antenna extender
PANDUIT part number Liquid tight straight conduit connector
AIR-ACC2537-060, for external
antenna mounting.
Bulkhead mount hex nuts
Liquid tight straight thru cord grip for data cable / POE entry
NEMA 4X RATED FITTINGS CABLE DIA. (INCHES)
PZNF1 PZNF2 PZNF3
.115" - .250" .230" - .395" .170" - .450"
18. Install a bulkhead antenna extender, CISCO part number AIR-ACC2537-060 to the bottom surface of the enclosure as shown.
Apply RTV silicone to the surface of the collar of the extender to maintain a liquid tight seal.The desired mount hole diameter is.53”.
19. Install the wall mount bracket (CISCO part number AIR-ACC2AMK1300) to the CISCO 1310 WAP as shown in the figure below.
Fasten the assembly to the aluminum back plate with the supplied #10-32 thread cutting screws as shown.
Installed aluminum mounting plate
#10-32 pan head thread cutting screws
CISCO 1310 Access Point
1310 wall mount bracket kit,
C
ISCO part number
AIR-ACCWAMK1300 (sold separately)
#10-32 pan head thread cutting screws
2” x 4” x 1 7/8” deep electrical box.
20. Fasten a 2” x 4” electrical box to the aluminum mount plate with the supplied #10-32 thread cutting screws, in line with the incoming
conduit fitting.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 7 of 10
Page 8
INSTRUCTIONS CM332A
21. Fasten the supplied 2 position surface mount box base the wall of the enclosure as shown using the double sided tape.
Alternatively, the base can be mounted to the aluminum back plate with the supplied (2) #6-32 flat head thread cutting screws.
Screws supplied with C
Power injector supplied with Cisco 1310 access point
Coaxial uplink locations
Power supply port
ISCO access point
2 Position surface mount box base with double sided tape. jack module supplied installed in position “1” of the surface mount box
Top surface of the enclosure
Ethernet port
Cisco 1310 access point
22. Attach the power injector supplied with the access point to the mount studs provided on the WAP. Orientate the injector so
that the coaxial uplinks and ethernet port are facing the bottom of the enclosure.
23. Run the network cable into the enclosure and terminate to the jack module installed in the surface mount box. Insert one end of the 2’
patch cord supplied into the opposite end of the jack module and route to the wireless access point RJ45 port as shown.
2’ patch cord supplied
2 position surface mount box
Incoming network cable
1’ dual RG-6 uplink cables connecting the power injector to the access point
CISCO 1310 Series with power injector shown
Wireless access point Ethernet port
24. Attach the 1’ dual RG-6 ethernet uplink cable assembly to the power injector ports and to the corresponding connections on the access
point as shown in the figure above.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 8 of 10
Page 9
INSTRUCTIONS CM332A
25. The CISCO AC power adapter supplied with the wireless access point can be located as shown, providing power to the power injector.
Slack the excess cable beside the adapter as shown.
Slack excess power cable beside the adapter as shown
C
ISCO AC power adapter
Outlet box
Power injector 48 VDC port
1/2” conduit
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 9 of 10
Page 10
INSTRUCTIONS CM332A
26. Attach the required external antennas to the bulkhead fittings installed on the bottom surface of the enclosure. Wrap the excess bulkhead
cable slack around the mounted wireless access point.
C
ISCO 1310 access point shown
Bulkhead antenna extender part number AIR-ACC2537-060
For instuctions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
www.panduit.com
Page 10 of 10
2.4 Ghz dipole antenna AIR-ANT4941 locations shown