Panduit POEXTX1 Installation Manual

Page 1
PoE Extenders
Data and Power Over 4-Pair UTP up to 2,000ft (610m)
IP Device
Switch
Local Power Option
Local Power Option
Part Number(s): POEXTX1, POEXRX1, POEXRX4, POEXKIT1, POEXKIT4
© Panduit Corp. 2018
INSTALLATION INSTRUCTIONS
PN636
Installation Steps for Extender Kits
Remove the PoE Extender transmitter (POEXTX1) and receiver (POEXRX1 or POEXRX4) from their packaging.
Ensure your cable is properly terminated before connecting to any PoE Extender product.
Connect the transmitter (POEXTX1) port marked "TO SWITCH" to a port on the switch.
Connect the Category 5e or higher (Category 6 recommended) copper cable from the
t
ransmitter (POEXTX1) port
rked "TO TX".
ma
Using a copper cable or patch cord, connect the IP devices to the receiver (POEXRX1 or POEXRX4) port marked "TO IP DEVICE"
If using the local power option (supplied with POEXKIT1 or POEXKIT4), remove the power supply and cord from the car­ton.
1. Plug the DC barrel connector of the power supply into the PoE Extender box to be locally powered. The 110W
recommended for POEXRX4; the 60W supply can power either the POEXTX1 or POEXRX1. Plug the AC power cord, into the power supply and then into a local AC, grounded outlet.
2. . If the PoE receiver is locally powered and the PoE transmitter is not, the port on the switch or device the PoE
3
transmitter is connected to must be PoE capable
marked "TO RX" to the receiver (POEXRX1 or POEXRX4) port
is
.
Bandwidth Availability
100Mbps full duplex, symmetrical to 2,000 feet (610m) over 4-Pair UTP Copper Cable
1-Port PoE Extender Kit (POEXRX1 + POEXTX1 + 60W, 55V Power Supply)
Product Details (POEXTX1)
Paired with POEXRX1 or POEXRX4
Up to 50W PoE
Need to be locally powered when non-PoE switch is used
IEEE compliant
Product Details (POEXRX1)
Paired with POEXTX1
Up to 50W PoE
PoE on 4 pairs
IEEE compliant
Can be locally powered for additional PoE delivery
4-Port PoE Extender Kit (POEXRX4 + POEXTX1 + 110W, 55V Power Supply)
Product Details (POEXTX1)
Paired with POEXRX1 or POEXRX4
Up to 50W PoE
Need to be locally powered when non-PoE switch is used
IEEE compliant
For Technical Support: www.panduit.com/resources/install_maintain.asp
Product Details (POEXRX4)
Paired with POEXTX1
1 uplink port & 4 downlink ports
Max 30W per downlink port
Supports IEEE compliant devices
Can be locally powered for additional PoE delivery
Page 1 of 4
Page 2
© Panduit Corp. 2018
INSTALLATION INSTRUCTIONS
PoE Length Guidelines for 1-Port Extender Kit
Scenario 1: 1 Port (POEXTX1) Transmitter Box Powered by 50W Power Sourcing Switch (assuming 55VDC output)
PoE
Class Standard
Max
Wattage
at PD
Under
Voltage
Lockout at PDPSE - TX1
TX1 - RX1 - Cable
Distance (ft)
23AWG
1.04Ω/100ft
24AWG
1.43/100ft
RX1 - PD
PN636
1 802.3af 3.84 37 2 802.3af 6.49 37 2000 2000 3 802.3af 12.95 37 1791 1303 4 802.3at 25.5 42 1257 914 5 802.3bt 6 802.3bt
N/A N/A N/A N/A
50ft
2000 2000
N/A N/A N/A N/A
Scenario 2: 1 Port (POEXTX1) Transmitter Box Locally powered (55VDC output)
Max
PoE
Class Standard
1 802.3af 3.84 37 2 802.3af 6.49 37 2000 2000 3 802.3af 12.95 37 1798 1303 4 802.3at 25.5 42 1263 915 5 802.3bt 6 802.3bt
Wattage
at PD
N/A N/A N/A N/A
Under
Voltage
Lockout at PDSW - TX1
Up to 100m
TX1 - RX1 - Cable
Distance (ft)
23AWG
1.04Ω/100ft
2000 2000
N/A N/A N/A N/A
24AWG
1.43/100ft
Scenario 3: 1 Port (POEXRX1) Receiver Box Locally powered (PoE Switch at head end)
Max
PoE
Class
Standard
1 802.3af 3.84 37 2 802.3af 6.49 37 2000 2000 3 802.3af 12.95 37 2000 2000 4 802.3at 25.5 42 2000 2000 5 802.3bt 40 42 2000 2000 6 802.3bt
Wattage
at PD
N/A N/A
Under
Voltage
Lockout at
PD
PSE - TX1
50ft
TX1 - RX1 - Cable
Distance (ft) RX1 - PD
23AWG
1.04Ω/100ft
2000 2000
N/A N/A
24AWG
1.43/100ft
50ft
RX1 - PD
50ft
50ft
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 2 of 4
Page 3
© Panduit Corp. 2018
INSTALLATION INSTRUCTIONS
PoE Length Guidelines for 4-Port Extender Kit
Scenario 1: 4 Port (POEXRX4) Receiver Box Powered by 50W Power Sourcing Switch (assuming 55VDC output)
PoE
Class
(4 ports)
Standard
Total
Wattage
Available
for PD(s)*
Under
Voltage
Lockout at PDPSE - TX1
TX1 - RX4 - Cable
Distance (ft)
23AWG
1.04Ω/100ft
1.43/100ft
24AWG
RX4 - PD(s)
PN636
1 802.3af 15.36 37
2000 2000 2 802.3af 25.96 37 1791 1303 3 802.3af 4 802.3at 5 802.3bt 6 802.3bt
* - Total wattage available refers to the maximum amount of power available at the PD. For example, in Class 2 scenario
above which shows 25.96 W available this can support four Class 2 devices or two Class 3 devices.
N/A N/A
N/A N/A N/A N/A N/A N/A
50ft
N/A N/A N/A N/A N/A N/A N/A N/A
Scenario 2:1 port (POEXTX1) Transmitter Box Locally powered (55VDC output)
PoE
Class
Standard
(4 ports)
1 802.3af 15.36 37 2 802.3af 25.96 37 1798 1303 3 802.3af 4 802.3at 5 802.3bt 6 802.3bt
* - Total wattage available refers to the maximum amount of power available at the PD. For example, in Class 2 scenario
above which shows 25.96 W available this can support four Class 2 devices or two Class 3 devices.
Total
Wattage
Available
Lockout at
for PD(s)*
N/A N/A
N/A N/A N/A N/A N/A N/A
Under
Voltage
PD
SW - TX1
Up to 100m
TX1 - RX4 - Cable
Distance (ft) RX4 - PD(s)
23AWG
1.04Ω/100ft
24AWG
1.43/100ft
2000 2000
N/A N/A N/A N/A N/A N/A N/A N/A
Scenario 3: 4 port (POEXRX4) Receiver Box Locally powered (PoE Switch at head end)
PoE
Class
Standard
(4 ports)
1 802.3af 15.36 37 2 802.3af 25.96 37 2000 2000 3 802.3af 51.8 37 2000 2000 4 802.3at 102 42 2000 2000 5 802.3bt 6 802.3bt
* - Total wattage available refers to the maximum amount of power available at the PD. For example, in Class 2 scenario
above which shows 25.96 W available this can support four Class 2 devices or two Class 3 devices.
Total
Wattage
Available
for PD(s)*
N/A N/A N/A N/A
Under
Voltage
Lockout at
PD
PSE - TX1
50ft
TX1 - RX4 - Cable
Distance (ft) RX4 - PD(s)
23AWG
1.04Ω/100ft
24AWG
1.43/100ft
2000 2000
N/A N/A N/A N/A
50ft
50ft
50ft
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 3 of 4
Page 4
© Panduit Corp. 2018
INSTALLATION INSTRUCTIONS
PN636
Safety Considerations
These instructions provide basic installation information necessary for the proper and safe functioning of this equipment. Persons installing or maintaining this product must read all the safety instructions and the parts of system grounding, which are applicable to the system being maintained. Only trained, qualified service personnel shall install or maintain this product. Do not attempt to install or service this equipment unless you are skilled in the installation and maintenance of electronic telecommunications equipment and have successfully completed specific training for this equipment.
SYSTEM GROUNDING (EARTHING):
Earth Ground is provided in the POEXKIT1 or POEXKIT4 through the 15A three-wire AC power cord. If replacing this cord, use a cord of the same gauge, insulation, number of conductors, and usage ratings. POEXTX1, POEXRX1 and POEXRX4 have no earth ground connection unless it is provided by shielded, grounded RJ45 connectors. Refer to your cable manufacturer’s earthing ground recommendations and standards listed in the TIA568 specification such as ANSI-J-STD-607-A: Commercial Grounding (Earthing) and Bonding Requirements for Telecommunications.
WARNINGS:
FAILURE TO FOLLOW ALL INSTRUCTIONS MAY RESULT IN IMPROPER EQUIPMENT OPERATION AND/OR RISK OF ELECTRICAL SHOCK. ANY CONNECTION TO AN OUTSIDE PLANT LEAD, AN OFF-PREMISE APPLICATION, OR ANY OTHER EXPOSED PLANT APPLICATION MAY RESULT IN A FIRE OR SHOCK HAZARD, AND/OR DEFECTIVE OPERATION, AND/OR EQUIPMENT DAMAGE.
Keep these instructions with the equipment.
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
Document No. 445-0014-A
www.panduit.com
Page 4 of 4
E-mail:
techsupport@panduit.com
Phone:
866-405-6654
Loading...