Part Number(s): PND110
© Panduit Corp. 2018
INSTALLATION INSTRUCTIONS
Installation Precautions
• For best results, place the Table Top Box, Tilt Up
in a dry area away from dust.
• To prevent fire or shock, do not expose this unit to
water or moisture. Do not place the unit in direct
sunlight, near heaters or heat-radiating
appliances, or near any liquid. Exposure to direct
sunlight, smoke, or steam can harm internal
components.
• Handle carefully; dropping or jarring can damage
the bezel.
• Never place fingers inside the opening on either
side of the unit. This action could cause injury due
to sharp edges inside.
• Do not place heavy objects on top of the Table
Top Box, Tilt Up. Do not use excessive force to
push down on the top of the unit.
• Disconnect the power cord to turn off the power.
This supplies power to the socket on the pop up
panel. The power outlet should be installed near
the equipment and be easily accessible.
• We recommend using wall outlets with a Ground
Fault Circuit Interrupter (GFCI) for maximum
protection.
• Install all cables according to the instructions
found herein. Do not force or pull any cable that is
attached to the Table Top Box, Tilt Up.
PN624
Parts Included:
(1) Table Top Box
(1) Plate
(1) Mini-Com Faceplate
(1) NetKey Faceplate
(2) Mounting Brackets
(4) Mounting Screws
(2) Table Securing Screws
(2) Wing Nuts
(2) Cable Clamps & Screws
(1) Fastener Tool
Cleaning
• Surfaces should be cleaned with a dry cloth. Never use
strong detergents or solvents such as alcohol or
thinner. Do not use a wet cloth or water to clean the
unit.
Operation
• The Table Top Box, Tilt Up will open easily when the
top is pressed down and then released.
• When the Table Top Box, Tilt Up is not in use, simply
press the top down until it is level with the surface of
the table and then release. The unit will remain hidden
until needed again.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 1 of 4

PRINT UNSCALED AT 100%
© Panduit Corp. 2018
Plate
Mounting Screws
Modules
(Recommended
angled wire cap)
INSTALLATION INSTRUCTIONS
Faceplate
(NetKey or
Mini-com)
PN624
Note:
Modules in these
two positions have
limited clearance
(Recommended
angled wire cap)
Table Top Box,
Tilt Up
Use cut-out
template on
(page 4)
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 2 of 4

PRINT UNSCALED AT 100%
© Panduit Corp. 2018
Mounting
Brackets (2)
Wing Nuts (2)
Table securing
screws (2)
INSTALLATION INSTRUCTIONS
Operator
Interface
PN624
Tabletop
Min. thickness 0.5" [1.27cm]
Max. thickness 3.5" [8.89cm]
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 3 of 4

6.13”
[15.570cm]
7.46”
[18.948cm]
0
1
23
0123
4
5
cm
Inch
R 0.5”
[1.27cm]
PRINT UNSCALED AT 100%
© Panduit Corp. 2018
INSTALLATION INSTRUCTIONS
Tilt Up Table Top Box cut-out template
PN624
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
www.panduit.com