WARNING: LASER LIGHT IS INVISIBLE. THE INVISIBLE LIGHT
IS POWERFUL ENOUGH TO DAMAGE YOUR EYES. SERIOUS
DAMAGE TO THE RETINA OF THE EYE IS POSSIBLE. NEVER
LOOK INTO THE END OF A FIBER THAT MAY HAVE A LASER
COUPLED INTO IT. SHOULD ACCIDENTAL EYE EXPOSURE TO
LASER LIGHT BE SUSPECTED, ARRANGE FOR AN EYE
EXAMINATION IMMEDIATELY.
2. CABLE HANDLING
WARNING: FIBER OPTIC CABLE CAN BE DAMAGED BY
EXCESSIVE PULLING, TWISTING, CRUSHING OR BENDING
STRESSES. CONSULT THE APPROPRIATE SPECIFICATION
SHEETS AS PROVIDED BY YOUR CABLE VENDOR. ANY
DAMAGE MAY DECREASE OPTICAL PERFORMANCE.
Important Connector Cleaning Information
Clean all connectors prior to connection. Just like single fiber connectors, all multi-fiber connectors must be properly cleaned
prior to connection to ensure optimum optical performance is achieved. Although interconnect cords and cable assemblies are
shipped from the factory pre-cleaned and protected with a dust cover, the user should never assume the ferrule or connector
has not been contaminated. A contaminated endface may not meet system insertion loss and reflectance requirements or may
cause permanent damage to the fiber(s) when mated to another connector. Therefore, it is recommended that each ferrule
endface or tip be cleaned using this procedure prior to connection.
1. Grip the FMTPFCT, depressing the green lever of the
cleaning tool. The metal shutter on top of the cleaning tool
will open, exposing fresh cleaning material. Fresh material
is exposed each time the green lever is depressed.
2. Position the female MTP* ferrule endface so that the fiber
tips are in contact with the cleaning material. Wipe the
ferrule endface along the cleaning material in the direction
shown on the cleaning tool.
3. Release the green lever of the cassette to cover the
cleaning material.
4. Repeat steps 1, 2 and 3 to ensure that any contamination
is removed.
*MTP is a registered trademark of US Conec Ltd.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 2 of 4
INSTALLATION INSTRUCTIONS PN433
FMTPMFCT Instructions - Cleaning Male MTP* Connectors
1. Grip the FMTPMFCT, depressing the green lever of the
cleaning tool. The metal shutter on top of the cleaning tool
will open, exposing fresh cleaning material. Fresh material
is exposed each time the green lever is depressed.
2. Position the male MTP* ferrule endface so that the fiber
tips are in contact with the cleaning material. Wipe the
ferrule endface along the cleaning material in the direction
shown on the cleaning tool.
3. Release the green lever of the cassette to cover the
cleaning material.
4. Repeat steps 1, 2 and 3 to ensure that any contamination
is removed.
NOTE: The FMTPMFCT MTP* Male Fiber Cleaning Tool is
designed to provide clearance for the connector’s guide
pins allowing the fiber tips to contact the cleaning material.
1. Remove the external connector or dust cover from the
QUICKNET Cassette MTP* adapter.
2. Remove the dust cap from the FIBCCT.
3. Insert the cleaning tool tip into the MTP* adapter as
shown.
NOTE: The FIBCCT Q
UICKNET Cassette MTP* Cleaning
Tool is keyed the same as a MTP* connector. Insert the
cleaning tool tip into the Q
UICKNET MTP* adapter with the
key of the cleaning tool tip matching the keyway of the
adapter.
4. Rotate the tape feeder wheel in the direction indicated on
the cleaning tool.
5. Remove the cleaning tool from the QUICKNET Cassette
MTP* adapter.
6. Repeat steps 3, 4 and 5 to ensure that any contamination
is removed. Replace the dust cap onto the cleaning tool.
7. Clean the external connector as described in the sections
above.
8. Reinstall the external connector into the QUICKNET
Cassette MTP* adapter.
*MTP is a registered trademark of US Conec Ltd.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 3 of 4
INSTALLATION INSTRUCTIONS PN433
FMTPRR6 - Replacing FMTPFCT and FMTPMFCT Cleaning Reel
1. The cleaning reel should only be replaced in a clean and dust free environment. A contaminated cleaning reel may
cause damage to fibers.
2. Use a coin or
screwdriver to
loosen the screw
located on the front
of the FMTPFCT or
FMTPMFCT Fiber
Cleaning Tools.
3. Open and remove
the cover using the
finger grip on the
side of the tool.
Winding Reel
Cleaning Reel
4. Remove the
cleaning reel and
winding reel by
lifting them straight
out of the tool.
Remove the
cleaning tape from
the winding reel.
Do not discard the
5. Place the empty
winding reel next to
the new cleaning
reel as shown.
Detach the
adhesive tape from
the cleaning reel
and attach to the
winding reel.
blue winding reel.
6. Place the winding
reel and the
cleaning reel into
the tool and route
the cleaning tape as
7. Hook the cover on
the tool body and
swing the cover
closed. Tighten the
screw.
shown on the
diagram located on
the tool cover.
8. Depress the green lever a few times and verify that the cleaning tape is advancing properly.
Hooks
*MTP is a registered trademark of US Conec Ltd.
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
www.panduit.com
Page 4 of 4
E-mail:
cs@panduit.com
Fax:
(708) 444-6993
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.