tronic, mechanical, photocopying, recording or otherwise, without written permission from Panduit. No patent liabilityis assumed with respect to the use of the
information contained herein.
Although every precaution hasbeen taken in the preparation of thisbook, Panduitassumes no responsibility for errors or omissions. Neither is any liability
assumed for damages resulting from the use of the information contained herein.
- 2 -
Page 3
OptiCam 2 FS133 Termination Tool User Manual
Table of Contents
OptiCam 2 FS133 Termination Tool Overview5
Safety Precautions7
Safety Glasses7
Isopropyl Alcohol (92% or better)7
Disposal of Bare Fibers7
Laser Light7
Cable Handling8
Tool Set Up9
Component Identification14
Buffer Stripping Steps16
250μm Coated Fiber Strip16
900μm Tight-Buffered Fiber Strip16
Jacketed Cable Strip17
250μm Coated Fiber Termination Using OptiCom Fanout Kit17
Buffer Stripping18
Cleave Fiber Steps19
Prep Stripped Fiber19
Score & Cleave19
OptiCam 2 Tool Operation - LC21
Select Connector Options21
Load Connector21
Connector Test22
- 3 -
Page 4
OptiCam 2 FS133 Termination Tool User Manual
Insert Cleaved Fiber22
Cam Connector23
Review Test Results23
Assemble Connector and Boot25
LC Connector and Boot25
SC Connector and Boot26
ST Connector and Boot27
Tool Care and Maintenance28
Connect-It App Use31
- 4 -
Page 5
OptiCam 2 FS133 Termination Tool User Manual
OptiCam 2 FS133 Termination Tool Overview
WARNING
Read and understand the instructions and safety information in thismanual
before operating this tool. Failure to observe this warning can result in bodily
injury.
Warning: Riskof fire. Battery can explode or leak and cause injury if installed
backwards, disassembled, charged, crushed, or exposed to fire or high tem-
perature.
CAUTION
Caution - Use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous radiation expos-
ure. The laser is emitted from the LC connector located at the top of the tool.
See the next page illustration for connector location.
l Never point the laser into the eyes of others.
l Do Not stare directlyat the laser beam.
l Do Not set up tool to work at eye level or operate the tool on a reflect-
ive surface as the laser could be pr ojected into your eyes or the eyes
of others.
Viewing the laser output with certain opticalinstruments (for example, eye
loupes, magnifiers, and microscopes) within a distance of 3.9” (99 mm) may
pose an eye hazard.
TECHNICAL INFORMATION
l Recommended Use: Withavailablelaunch cords and cradles only
l Laser Dio de Type: IEC 60825-1 Class 1 Laser product
l Co nn ectors: LC, SC, ST, single mode and multimode, Panduit con-
nectors only
l Power Supp ly: 2 size AA (type L91) 1.5voltLithium Iron Disulfide bat-
teries, MaxDischarge: 2.5 amp continuous, included. Size AA alkaline
batteries can be used at a reduced rate battery life. Tool can also be
powered without batteries through the power/data (5 VDC, 1 amp
max) port on the side of the tool.
l Rat ed Battery Life: Approximately8 hours (continuous use)
l Firmware Up dates: Use power/data port on the side of the tool to
connect to PC, visit www.panduit.com for latest firmware
l Environment: FOR INDOOR USE ONLY, Maxaltitude 2000m, Pol-
lution degree 2
l Operating Temperature: +32° F to +104° F (0° C to +40° C), <93%
RH, non-condensing
l Sto rage Temperature: -40° F to +158°F (-40°C to +70°C)
l Overall Dimension s: 2.1" H x2.8" W x9.1" L (53mm x 71mm x
231mm)
l Weight: 9.0 oz (255 g) without batteries
Remove the batteries when storing for an extended period of time to avoid
damage to the tool should the batteries deteriorate.
Tool Storage
After all connector terminations are complete, detach the launch cord from the toolby disconnecting the LC connector at the top of the tool. Detach the ferrule
adapter from the cradle and put dust capson both endsof the launch cord. Place tool, launch cord, and cradle in a protective case.
Tool Use
This toolis to be used for the termination of Panduit OptiCam connectors only. The tool emits a non-visible laser beam, which, when used in conjunction with
the launchcord and cradle, aids inproper connector termination.
Tool Care and Handling
l Laser tools ar e precision instruments, which should be handled with care. See Safety Precautions.
l Avoid shock, vibrations, and extreme heat.
l Avoid dust and water that could obstruct laser.
l Keep tool dry and clean.
l Check batteries regularly to avoid deterioration.
l Remove batteries if the tool is to be stored for an extended period.
- 5 -
Page 6
OptiCam 2 FS133 Termination Tool User Manual
l This tool containsno user-serviceable parts.
l The laser output isnot adjustable.
l Contact Panduit Corp. for service needs.
Do not Throw Away
This symbol indicates the need for separate collectionof electrical and electronic equipment waste. Separating electronic waste can halt the potential adverse
effects on the environment and human health as a result of the hazardous substances in electricaland electronic equipment. This waste should be returned
to the pr oper collection facility.
Compliance Symbols
Complies with IEC 60825- 1 Ed. 3 (2014).
Complies with F DA performance standards for laser products except for deviations pur suant to Laser Notice No. 50, dated May 15, 2014.
This device compiles with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and (2) this device must accept any interference received, including any interference that may cause
undesired operation.
La operación de este equipo está sujeta a las siguientes dos condiciones: (1) es posible que este equipo o dispositivo no cause interferencia perjudicial y (2)
este equipoo dispositivo debe aceptar cualquier interferencia, incluyendo la que pueda causar su operación no deseada.
CAN ICES-3(B)/NMB-3(B)
IMPORTANT: DO NOT remove any labels from this tool.
- 6 -
Page 7
Safety Precautions
Safety Glasses
WARNING: It is strongly recommended that safety glasses be worn when handling bare optical
fiber. The bare fiber is very sharp and can easily damage the eye.
Isopropyl Alcohol (92% or better)
WARNING: Flammable.
OptiCam 2 FS133 Termination Tool User Manual
Contact with alcohol can cause irritation to the eyes. In case of contact with eyes, flush with water for at least 15 minutes.
Always use alcohol with proper levels of ventilation.
In case of ingestion, consult a physician immediately.
Disposal of Bare Fibers
WARNING: Pick up and discard all pieces of bare fiber with sticky tabs. Do not let cut pieces
of fiber stick to clothing or drop in the work area, where they are hard to see and can cause
injury.
Laser Light
DO NOT VIEW DIRECTLY WITH OPTICAL INSTRUMENTS. CLASS 1M LASER PRODUCT.
Viewing the laser output with certain optical instruments (for example, magnifiers and microscopes) within a distance of 100
mm may pose an eye hazard.
- 7 -
Page 8
OptiCam 2 FS133 Termination Tool User Manual
CAUTION: Use of controls of adjustments or performance of procedures other than those specified herein may result in
hazardous radiation exposure.
l Never point the laser into the eyes of others
l Do not stare directly at the laser beam.
Do not set up tool to work at eye level or operate the tool on a reflective surface as the laser could be projected into your eyes, or
the eyes of others.
Cable Handling
WARNING: Fiber optic cable can be damaged by excessive pulling, twisting, crushing or bending stresses. Consult the
appropriate specification sheets as provided by your cable vendor. Any damage may decrease optical performance.
To Ensure Best Termination
l Make sure the batteries are new and fresh.
l Make sure the launch cord is in good condition, the split sleeve is in good condition, and the ferrule end face is clean and not
scratched.
- 8 -
Page 9
Tool Set Up
Various components of the OptiCam 2 Tool:
OptiCam 2 FS133 Termination Tool User Manual
1. Select the proper Launch Cord and Cradle. For each connector type, select the correct launch cord and cradle for termination use.
Connector Type, Launch Cord, and Cradle cross reference table
Connector TypeLaunch CordCradle*
LC single mode
LC multimode: OM1, OM2, OM3, and
OM4
SC single mode
SC multimode: OM1, OM2, OM3, and
OM4
ST single mode
ST multimode: OM1, OM2, OM3, and
OM4
yellow cable, 1.25mm single mode(P/N: FOLPC-
1.25SM)
orange cable, 1.25mm multimode(P/N: FOLPC-
1.25MM)
yellow cable, 2.5mm single mode(P/N: FOLPC-
2.5SM)
orange cable, 2.5mm multimode(P/N: FOLPC-
2.5MM)
yellow cable, 2.5mm single mode(P/N: FOLPC-
2.5SM)
orange cable, 2.5mm multimode(P/N: FOLPC-
2.5MM)
LC cradle, black (P/N: FLCC2)
LC cradle, black (P/N: FLCC2)
SC cradle, gray (P/N: FSCC2)
SC cradle, gray (P/N: FSCC2)
ST cradle, gray (P/N: FSTC2)
ST cradle, gray (P/N: FSTC2)
*Each cradle contains a marking to identify it as type LC, SC, or ST.
- 9 -
Page 10
OptiCam 2 FS133 Termination Tool User Manual
2. To load or replace batteries, remove the battery cover using a Phillips screwdriver.
3. Insert 2 size AA (type L91) 1.5volt Lithium Iron Disulfide batteries, follow the polarity markings in the compartment. Then
replace the cover and secure it using the Phillips screw driver.
Note: The OptiCam 2 Tool does not charge batteries
WARNING: Risk of Fire.Battery can explode or leak and cause injury if installed backwards, disassembled,
charged, crushed, or exposed to fire or high temperature.
4. The protective film on the Camera Aperture has a removal tab. The protective film on the LCD display can be removed by
peeling from one corner.
Note: Remove the protective film from the Camera Aperture before operating the tool.
5. Before attaching the launch cord, first clean the launch cord on both ends. Refer to the Tool Care and Maintenance section of these instructions for proper technique.
6. Install the correct OptiCam 2 launch cord and OptiCam 2 cradle. An LC connector on the launch cord attaches to a port at
the top of the tool, and the unique adapter attaches it to the cradle.
- 10 -
Page 11
OptiCam 2 FS133 Termination Tool User Manual
7. Please refer to the Connector Type, Launch Cord, and Cradle Cross Reference Table to make sure you are using the
proper combination of cord, cradle, connector, and orientation.
8. When attaching the metal adapter to the cradle for LC terminations, the opening on the side of the barrel should be placed
facing the tool.
9. The cradle attaches to the tool magnetically. Position the cradle onto the tool with either a left or right orientation, and the
magnets will properly align the cradle. Right and left orientations are shown below (LC launch cord and LC Cradle are
shown).
10. Power on by using the center of the navigation button. The first time the tool is powered on, the language will need to be
selected.
- 11 -
Page 12
OptiCam 2 FS133 Termination Tool User Manual
11. Use the navigation button to navigate to the menus and to Connector Type , and select the correct connector options:
Menu > Connector Type.
12. Use the navigation button to select the correct information. The selected text will become red. Click Save.
Note: To ensure proper function of the tool, check that settings on the tool match the cord, cradle, con-
nector, and orientation being used.
13. To select the Insertion Loss (IL) Threshold, use the navigation button to navigate to the menus and to Tool Settings,
then scroll down to IL Threshold. The settings window will allow you to select the desired threshold by moving the nav-
igation button up and down and selecting Save, which will exit out of this topic.
- 12 -
Page 13
OptiCam 2 FS133 Termination Tool User Manual
14. To load the connector, first clean the connector ferrule end face using Panduit’s best
practices for cleaning fiber components. LC and SC connector loading: A) Insert a
connector while the launch cord is tilted up to receive the connector. B) Tilt the connector down and ensure the connector backbone snaps in to the cradle. This image
shows the new metal ferrule adapter for LC launch cords.
15. To load an ST connector: A) Rotate the ST connector into the cradle. B) Rotate the
retaining clip over the connector. C) Secure the clip with the audible “click”. D) Place
the launch cord on the connector end with the split sleeve attaching to the connector
ferrule.
Note: ST requires that the user hold the launch cord in place.
16. The OptiCam 2 has a data port on the side of the tool which can be used to install firmware updates. The current version
of the software on the tool can be determined in the System Menu on the tool.
17. Update the tool to the most recent firmware available at Panduit.com > Support > Download Center > Soft-ware/Firmware/Printers > OptiCam 2 Termination Tool.
- 13 -
Page 14
OptiCam 2 FS133 Termination Tool User Manual
Component Identification
LC Connectors, Launch Cord, and Cradle
SC Connectors, Launch Cord, and Cradle
ST Connectors, Launch Cord, and Cradle
Alignment Key must be in the alignment tab to cam properly. Additionally, the flat sides on the back bone will line up into the key
slot of the cradle with the etched, rounded side facing down.
- 14 -
Page 15
OptiCam 2 FS133 Termination Tool User Manual
Connector Types with Colors
Fiber TypeBackbone Color (LC, SC)Boot Color
OM3, OM4 (50µm)AquaAqua
OM2 (50µm)BlackBlack
OM1 (62.5µm)BeigeBeige
OS1, OS2 (Single mode)BlueBlue
- 15 -
Page 16
OptiCam 2 FS133 Termination Tool User Manual
Buffer Stripping Steps
250μm Coated Fiber Strip
1. Install the boot. Insert the fiber end through the small end of the boot. Slide the boot
back out of the way.
2. Place one build-up tube (F250BT) onto the fiber and slide it back out of the way.
3. Place an insertion mark on the build-up
tube at 0.59” (15mm) for LC and 0.43”
(11mm) for SC/ST, from the end of the
tube closest to the end of the fiber.
4. Use buffer stripper to strip at least 1.18"
(30mm) of coating.
5. Place an insertion mark on the coated
fiber 2" (51mm) from the end of the
stripped coating.
IMPORTANT! 250µm Coated Fiber Stripping Dimensions. Due to printing variations, use a rigid scale for
stripping dimensions, or the appropriate Panduit laminated template.
6. Slide the leading edge of the build-up tube to the start of the coating after cleaving the fiber.
900μm Tight-Buffered Fiber Strip
1. Insert the fiber end through the small end of the 900μm boot. Slide the boot back out of the
way.
2. Use buffer stripper to strip at least 1.18" (30mm) of buffer.
3. Use the marking pen to place an insertion mark at 0.59” (15mm) for LC and 0.43” (11mm) for
SC/ST, back from the end of the stripped buffer.
IMPORTANT! 900µm Coated Fiber Stripping Dimensions. Due to printing variations, use a rigid scale for
stripping dimensions, or the appropriate Panduit laminated template.
- 16 -
Page 17
OptiCam 2 FS133 Termination Tool User Manual
Jacketed Cable Strip
1. If using duplex cable, split the two cables
approximately 6" (152mm) or as needed.
2. Following the stripping dimensions, use the
marking pen to mark the cable jacket at 1.89”
(48mm) for LC, and 1.73" (44mm) for SC/ST,
from the end.
3. Strip off the cable at the jacket removal mark.
To reduce wear on the jacket stripper blades,
do not slide the blades along the aramid yarn.
Instead, use the tool to cut through the jacket,
then pull off the jacket by hand.
4. Insert the fiber through the small end of the appropriate boot for your specific cable type. Use the boot to fold the aramid
yarn back over the jacket, holding it out of the way.
5. Use the marking pen to place a buffer length mark on the buffer at 0.71” (18mm) for LC, and 0.55" (14mm) for SC/ST,
from the edge of the jacket. Place an insertion mark at 0.59” (15mm) for LC and 0.43" (11mm) for SC/ST, back from the
first mark.
IMPORTANT! Due to printing variations, use a rigid scale for stripping dimensions, or the appropriate Panduit laminated template.
6. Use the marking pen to place a mark on the buffer at the edge of the jacket. This mark should remain at the edge of the
jacket after buffer stripping.
7. Use the buffer stripper to strip the buffer to the buffer length mark.
250μm Coated Fiber Termination Using OptiCom Fanout Kit
1. Install the Fanout Kit (FO6CB, FO12CB) according to the installation instructions FS047.
2. Feed the 250μm coated fibers through the 900μm fanout tubing until at least 30mm of fiber
protrudes from the end of the tubing. Trim the coated fibers to length at 30mm.
- 17 -
Page 18
OptiCam 2 FS133 Termination Tool User Manual
3. To reduce the amount of fiber movement, place a drop of
adhesive (Loctite 401 or equivalent Cyanoacrylate adhesive)
at the point that the coated fibers exit the 3mm cable jacket.
250μm coated fibers need to be taut between cable jacket
and the fanout tube assembly.
4. Place the 900μm boots onto the fanout tubing and slide them
back out of the way.
5. Place an insertion mark on the fanout tubing, at 0.59” (15mm) for LC and 0.43" (11mm) for SC/ST, back from the end of
the tubing.
6. Place a coating removal mark on the coated fiber 3mm from the end of the fanout tubing. Strip the coating up to the coating removal mark. Note: The 3mm of coating extending from the end of the tubing is intended to compensate for fiber
movement within the fanout tubing during termination.
Buffer Stripping
1. Remove no more than 1/4" (6mm) of buffer at a time to avoid breaking the fiber.
2. Hold the buffer stripper such that the tool is at a 90-degree angle to the fiber to ensure
clean cut of buffer.
3. Position the fiber in the tool's V-notches. Squeeze the handles and pull toward the end
of the fiber.
- 18 -
Page 19
Cleave Fiber Steps
Prep Stripped Fiber
1. Remove and dispose of any remaining fiber scraps in the cleaving
tool.
2. Clean bare fiber using an isopropyl alcohol (92% concentration)
soaked lint-free wipe. The fiber should be free of all coating and
residue. To prevent contamination, do not set fiber down or
allow it to touch anything after cleaning.
3. Hold the cleaving
tool in your hand and
depress the fiber
clamp lever to raise
the fiber clamp.
Insert the end of the
fiber into the Vgroove and under the
fiber clamp. Release
the fiber clamp lever
when the end of the buffer is located at the 7mm mark (±0.5mm). This length is critical to termination.
OptiCam 2 FS133 Termination Tool User Manual
Score & Cleave
1. This is a critical step for successful termination. Gently hold the buffered fiber against the groove in the base plate
using thumb and forefinger of your free hand. With your other thumb, gently push down on the housing until the ceramic
blade contacts the fiber only once. DO NOT cut the fiber with the ceramic blade. Release the housing so that the blade is
no longer contacting the fiber.
2. Hold the tool in one hand while still holding the fiber against the base plate. Bend the base plate down until the fiber
breaks. To prevent contamination, do not re-clean the fiber, do not set fiber down, or allow it to touch anything
after cleaving.
- 19 -
Page 20
OptiCam 2 FS133 Termination Tool User Manual
IMPORTANT: Do not clean fiber after cleaving. Replace the ceramic blade in the cleaving tool after
every 1000 cleaves, or if installation yield decreases. Replacement blades (FJQCVRB) are available.
- 20 -
Page 21
OptiCam 2 FS133 Termination Tool User Manual
OptiCam 2 Tool Operation - LC
Select Connector Options
1. Use the navigation button to navigate to the menus and to “Connector Type”, and select the correct connector options:
Menu > Connector Type.
2. Use the navigation button to select the correct information. The selected text will become red. Click Save.
The orientation of the connector indicates the direction that the fiber is inserted from. If Auto is selected, the tool
will determine this orientation automatically.
Note: To ensure proper function of the tool, check that settings on the tool match the cord, cradle, connector, and orientation being used.
Load Connector
A) Insert a connector while the launch cord is tilted up to receive the connector. B) Tilt the connector down, ensure the connector backbone snaps in to the cradle.
- 21 -
Page 22
OptiCam 2 FS133 Termination Tool User Manual
Note: Each connector has slightly different cradle operation. Refer to the individual connectors’ specific instructions in
the Tool Set Up section.
Connector Test
To start the connector test, select the Next icon,
pressing the navigation button directly down. The
tool will perform a background test of the connector.
After passing the background test, the Insert Fiber
command will display automatically.
Note: While performing the steps it is important to
avoid touching the connector except when camming the connector to get the best results from the tool.
Insert Cleaved Fiber
Insert cleaved fiber and maintain gentle forward
pressure while waiting for the CAM & Test command to appear on the screen.
- 22 -
Page 23
OptiCam 2 FS133 Termination Tool User Manual
Cam Connector
LC Camming requires that the whole connector rotate. When the screen displays the CAM & Test
command, A) Maintain gentle forward pressure on the field fiber, and B) “Cam” the connector, then
select the Next arrow to perform the test.
SC Camming requires that the key “Fin” rotates, and the rest of the connector remains in place.
Note: This image shows the new metal ferrule adapter for LC launch cords.
Detail A
ST Camming
ST Camming is done by rotating the key lever of the cradle, which engages the internal camming parts of the connector.
Review Test Results
Verify that the IL value meets project requirements.
- 23 -
Page 24
OptiCam 2 FS133 Termination Tool User Manual
If the IL does not meet your project requirements, select the cancel icon and repeat the fiber termination process for that connector ID. Selecting forward advances the connector ID number for the tool to do another termination. In both cases, the results
will be recorded in the tool for later retrieval. The OptiCam connector can be reused up to three times.
- 24 -
Page 25
OptiCam 2 FS133 Termination Tool User Manual
Assemble Connector and Boot
LC Connector and Boot
1. Grip the boot by the large end and push the boot forward onto the grooved area of the backbone until it is against the
flange. The insertion mark should be at the end of backbone.
2. Clean the ferrule end face with an alcohol soaked wipe and then a dry wipe. Place the dust cap over the ferrule end.
3. (Optional) With a connector held as shown (latch on top, ferrule facing away), insert the connector into one side of the
duplex clip as shown (clip held with the “A->B” polarity marking upright and facing forward). The upper tab of the clip
should slide into the pocket underneath the latch of the connector, and the lower tab should slide under the connector
housing and “snap”, locking it into place.
Repeat this procedure for the other connector, completing the duplexing step.
Note: When making cable assemblies, be sure to follow the correct “A->B” polarity cross-over
between connectors.
- 25 -
Page 26
OptiCam 2 FS133 Termination Tool User Manual
SC Connector and Boot
1. Grip the boot by the large end and push the boot forward onto the grooved area of the backbone until it is against the
flange. The insertion mark should be at end of backbone.
2. Align the external chamfers on the front of the inner housing assembly with the
internal chamfers at the front of the outer housing.
3. Push the inner housing assembly into the outer housing until it snaps into place.
Once in place the outer housing should be able to move freely back and forth over
the inner housing and boot.
4. The connector can be re-terminated if needed. Make sure that the dust cap is on the ferrule. Grip the outer housing and
push the connector tip down onto a hard surface. The inner housing will release from the outer housing. Remove outer
housing. Slide the boot off the backbone. Un-cam the connector and remove the fiber.
CAUTION: DO NOT push down without a dust cap installed on the ferrule. Doing so could damage the
pre-polished fiber end face.
5. Clean the ferrule end face with a dry wipe. Place the dust cap over the ferrule end.
6. (Optional) Orient the connector as shown with the connector key facing upward in the same
direction as the ‘A’, ‘B’ and ‘KEY’ markings on the duplex clip. Insert the connector into one
side of the clip on a slight angle and rotate into place. The upper and lower legs of the clip slide
over the connector and “snap” when the connector is in place. The connector is fully seated
once the top and bottom connector flanges are inside of the rectangular slots in the clip.
Repeat this procedure for the other connector, completing the duplexing step.
Note: When making cable assemblies, be sure to follow the correct ‘A->B’ polarity cross-over
between connectors.
- 26 -
Page 27
OptiCam 2 FS133 Termination Tool User Manual
ST Connector and Boot
1. Grip the boot by the large end and push the boot forward onto the grooved area of the backbone until it is against the
flange. The insertion mark should be at end of backbone.
2. Clean the ferrule end face with a dry wipe. Place the dust cap over the ferrule end.
3. Slide the boot back to release the aramid yarn. Cut the aramid yarn approximately 0.20" (5mm) past the flange. Flare the
aramid yarn evenly around the perimeter of the grooved area of the backbone. Use tweezers for best results. There will
be a slight gap between the cable jacket and the backbone. Push the boot forward and thread clockwise onto the grooved
area of the backbone until it seats against the flange. Best cable retention is achieved when the aramid yarn protrudes
slightly from the flange area.
- 27 -
Page 28
OptiCam 2 FS133 Termination Tool User Manual
Tool Care and Maintenance
1. The LC connector port and data port protective dust caps must be installed when the
tool is not in use to prevent contamination.
2. The camera aperture should be cleaned periodically with a soft, lint free cloth or with
isopropyl alcohol to remove dust and debris which may interfere with proper camera
operation. Avoid any scratches on the surface. The LC connector port can be cleaned
with clean dry air. Do not use alcohol.
3. The dust caps for both the LC connector (tool end) and the Ferrule Adapter (field connector end) must be installed when the cord is not in use. Do not coil the cable to less
than one-inch diameter at any time to avoid damaging the fiber.
4. The fiber tip of the launch cords should be cleaned every 50 connector terminations. To clean, retract the boot to expose
the cable crimp sleeve. Remove the Ferrule Adapter by holding the crimp sleeve and unthreading from the Ferrule
Adapter Assembly to expose the white ceramic split sleeve.
- 28 -
Page 29
OptiCam 2 FS133 Termination Tool User Manual
Note: 1.25 millimeter cord is shown for reference. The process is the same for the 2.5 millimeter cord.
5. Twist the split sleeve and pull to remove it from the assembly, exposing the tip of the fiber.
6. Wet an area of the fiber optic cleaning system wipes with fiber optic cleaning solution.
7. Clean the ferrule end faces of any connector or launch cord end, using a dry lint-free wipe.
- 29 -
Page 30
OptiCam 2 FS133 Termination Tool User Manual
8. If there is stubborn debris on the ends after dry cleaning, use this method: Using the cleaning solution, moisten one end of
a row on the cleaning box. Drag the tip of the fiber along the fiber cleaning row (example shown in blue) from the wet area
to the dry area. Then repeat the wiping procedure with a dry row (example shown in red).
9. To reassemble the Ferrule Adapter, first inspect the split sleeve for chipping or cracks. Thread the Ferrule Adapter onto
the Ferrule Adapter Assembly until the parts make contact. Hold the Cable Crimp Sleeve and turn the Ferrule Adapter
about 5° to tighten the adapter.
10. Always clean the LC connector end of the launch cord before inserting the connector into the tool. Remove the dust cap
and wipe the end face of the fiber, using the same wet/dry procedure. Insert the connector into the tool immediately after
cleaning.
- 30 -
Page 31
Connect-It
App Overview
OptiCam 2 FS133 Termination Tool User Manual
Connect-It App Use
1. Navigate to the menus of the OptiCam 2 tool and select: Tool Settings > Wireless > On. Then select Exit.
2. Enter the wireless password given when registering the tool at Panduit.com.
3. Turn wireless on.
Note: The tool name is found under Menus > Tool Settings > Tool Name. Rename for ease of use.
4. To create a new project in Connect-It app, enter the project credentials, and then select Create Project File.
- 31 -
Page 32
OptiCam 2 FS133 Termination Tool User Manual
5. Connect to the OptiCam 2 tool by pulling down to refresh the list and selecting the appropriate tool name from the list.
Then select Start Project.
6. The app will indicate that the tool has un-synced records if terminations were done on the tool without the app and tool
being synced. Select OK to sync. This transfers the records of the termination(s) to the project file in the app.
Note: The records will no longer be available on the OptiCam 2 tool.
- 32 -
Page 33
OptiCam 2 FS133 Termination Tool User Manual
7. To export the connector termination data, navigate to the “Project Overview” and select the current project. There are
three available options:
a. Share – enables the file to be emailed;
b. Select – opens the file;
c. Delete – deletes the file from the app.
8. To share, select the Share option. Your mobile device’s default email will open with a CSV attachment containing the
connector data.
9. While the mobile app is connected to the OptiCam 2 tool, open a previous project or create a new project. Verify the tool
settings and connector settings on the Tool Settings tab.
10. Properly set the IL threshold with the drop-down menu.
11. Select the Test Window tab.
- 33 -
Page 34
OptiCam 2 FS133 Termination Tool User Manual
12. Verify the connector type in the Test Window, and then install the connector into the cradle and select Load Connector.
The tool will perform a Background Test and automatically display Insert Fiber.
13. Insert the fiber into the connector. When the fiber is fully inserted, the graphic on the tool will change to Cam & Test.
14. Cam the connector per the connector style of camming, and maintain pressure on the field fiber at the same time.
15. Select Perform Test on the app.
16. The test result will display. Verify that the IL value meets project requirements.
- 34 -
Page 35
OptiCam 2 FS133 Termination Tool User Manual
17. If needed, re-test by using the Re-test icon, or re-terminate using the ReTerminate icon and repeat the fiber clean and
cleave steps. The OptiCam connector can be reused up to three times.
18. To export the connector termination data, navigate to the “Project Overview” and select the current project. There are
three available options:
a. Share – enables the file to be emailed;
b. Select – opens the file;
c. Delete – deletes the file from the app.
19. To share select the Share option. Your mobile device’s default email will open with a CSV attachment containing the connector data.
- 35 -
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.