Panduit NRVCB Installation Manual

Page 1
© Panduit Corp. 2009
20.25” = 19” RACK
24.25” = 23” RACK TYP
6.75 (10.0) [12.0]
16.00” = 19” RACK
20.00” = 23” RACK TYP
2.12 TYP
12.5 TYP
3.00 TYP
1.25 TYP
11.00 (14.25) [16.25]
Center of manager is forward approxi­mately 0.9” from center of rack
Center of rack
Mounting
Kits
Front/Rear Front Only
CMR19X47 CMR19X84 CMR23X84 CMR19X84NU
CMR19X84S NRD6
NRV6 NRVF6
NRVCB NFR84 CMR4P84 CMR4P84CN CMR4P84NU NRD10
NRV10 NRVF10
or CMR4P84D23 CMR4P84D23CN CMR4P84D23NU CMR4P84D23CNNU NRD12
NRV12 NRVF12
WMPVSMK R4P R4PCN R4P23 R4P23CN
R4P36 R4P36CN R4P42 R4P42CN
VERTICAL CABLE
MANAGEMENT
Racks
NRVCB
Doors
3” Deep R2P Series of 2 Post Racks
PART NUMBERS
NETRUNNER High Capacity Vertical Managers
INSTRUCTIONS CM392C
Location Guide for Center Mounting
(CMR19X84 with NRVCB)
Dimensions in (...) parenthesis are for 10” Vertical Cable Management Dimensions in [...] brackets are for 12” Vertical Cable Management
Standard Rack Installation
2
Bracket Installation
Note:
When installing between two racks use part number NRVCB for the additional brackets required. Bracket is keyed to be installed in the correct orientation.
Note:
Cable retainers
4
must point upward
1
Bottom Mounting Location
Mounting Orientation
3
FOR TECHNICAL SUPPORT www.panduit.com/resources/install_maintain.asp
#12-24 Screws
Location pin(s)
Top Mounting Location
Page 1 of 2
#12-24 Screws
Page 2
INSTRUCTIONS CM392C
4-Post Rack Installation using Brackets. Note: Step 1 is the same as for the Standard Rack.
2
#12-24 Screws
Tap ped Mounting Holes
Back of Post
Mounting
Bottom half of Manager
Bracket
4 Places
3
Location pin(s)
Installation Instructions NFR84 and 4-Post Racks using WMPVSMK side mounting kit
Note: Mount the racks to the floor.
1
Location pin(s)
2
#12-24 Screws
3/8 Bolt, Lock Washer & Nut
4
Top Half o f Manager
3
3/8 Bolt, Lock Washer & Nut
Opening and Closing Cover
Door
Door Latches
Finger
Tabs
Installation
Line up finger tabs with door latches. Then squeeze door
and fingers together to engage
(4 places).
To o pe n, grasp back of
door and push top button
with thumb. Repeat with
bottom button.
To close, grasp cable
retainers and door until
latched
Top Latch Buttons
Bottom Latch Buttons
Removal
To remove door, press bottom
latches first, then press top latch
bottons while holding door
Wire Retainer Installation (WR5E)
Use thumb to release wire retainer for removal
For instuctions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
www.panduit.com
Page 2 of 2