NETKEY
1
Puck
Notch
Orient jack
as shown
Label
(NKSPB)
2
CWST
Trim pair separator and/or
filler if present.
3
T568AT568B
P4 P3
P1 P2
P4 P2
P1 P3
4
Do not untwist
more then 1/8"
from the IDC
tower
Option 1 Option 2
(T568B shown)
5
PDT110
Tool
(T568B shown)
NETWORK COMPONENTS
CONTRACTOR GRADE
NetKey Category 5e, 6 & 6A Jack Modules
Part Number: NKP5E88M**, NK688M**, NK6X88M**
© Panduit Corp. 2013
INSTALLATION INSTRUCTIONS
NK406C
Retention
Cap
** Denotes color.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 1 of 2
![](/html/ca/ca94/ca94f42c89ebac68505cd2bd29d45ec272a07f946f7bf4b8fa4c7765e3a8eae0/bg2.png)
© Panduit Corp. 2013
11
Depress latch on jack
and gently tilt out.
INSTALLATION INSTRUCTIONS
NK406C
Notes:
1. For specified performance, follow TIA/EIA 568-B installation guidelines.
2. Jack Modules can terminate PVC or Plenum rated 22-26 AWG solid or stranded IWC cable with 0.048 inch (1.2 mm) maximum insulated
conductor outside diameter.
3. Jack Modules may be re-terminated a minimum of 20 times.
4. For technical and performance information, consult PANDUIT Technical Support.
As with all Communication Components, the following statements apply:
1. Never install communications wiring during a lightning storm.
2. Never install communications wiring in wet locations unless the jack is specifically designed for use in wet locations.
3. Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface.
4. Use caution when installing or modifying communication wiring.