Panduit MPS588-C Installation Manual

Page 1
Pan-Plug Category 5e
4.
Snipping tool
(CWST)
Optional WPT-8 Wire Prep Tool
4b1.
4b2.
4b3.
4b4.
5.
Drain Wire
1
8
6.
MPT5-8AS Termination Tool
Shielded Modular Plug
Part Number: MPS588-C
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
Cable Preparation
1. Strip back the cable jacket from the shield and cut away that portion of the cable jacket. Do not cut the shield.The shielded conductors should extend beyond the cable jacket 1.0" [25.4 mm]. (See Fig. 1).
2. Fold the shield back over the cable jacket, then trim the folded shield to 0.38" [9.53 mm]. The shield should wrap smoothly around the outside of the jacketed cable with the conductive surface exposed. (See Fig. 2 & 3).
3. Bend the drain wire back so it lies flat against the folded shield. Take care to orientate the drain wire so it touches the large tab within the modular plug housing and opposite from the strain relief. (See Fig. 4).
Conductor Sequence
T568A T568B
1 WH/GRN WH/ORG
2 GRN/WH ORG/WH
3 WH/ORG WH/GRN
4 BLU/WH BLU/WH
5 WH/BLU WH/BLU
6 ORG/WH GRN/WH
7 WH/BRN WH/BRN
8 BRN/WH BRN/WH
Untwist pairs and straighten conductors.
Cable Jacket
Fig. 1
Fig. 3
Shield
1.0"
[25.4mm]
Fig. 2
Strain
.38"
[9.52mm]
Drain wire
Fig. 4
Relief
Ta b
4a. (without Wire Prep Tool)
Place conductors in proper sequence (see table) and trim conductors to 7/16" (11mm) using wire snipping tool (CWST).
PN234C
Insert conductors individually in the proper sequence (See above table).
Remove cable from conductor retention slot, keeping conductors held in position by placing thumb and forefinger at cable jacket end.
Pull conductors until cable jacket is at conductor retention slot.
Place conductors in guide troughs, number 1-8 left to right with latch down as shown. Apply slight downward pressure as you insert conductors until they are fully extended and under the plug contacts.
Notes:
1. Panduit crimp tool MPT5-8AS recommended for crimping.
2. Terminates most 24-26 AWG stranded or solid conductor with an insulation dia of 0.035" - 0.040".
3. For information on grounding and bonding refer to TIA/EIA 607.
As with all Wiring Accessories, the following statements apply:
1. Never install communications wiring during a lightning storm.
2. Never install communications wiring in wet locations unless the jack is specifically designed for use in wet locations.
3. Never touch un-insulated communications wiring or terminals unless the communication line is disconnected at the network interface.
4. Use caution when installing or modifying communication wiring.
For Instructions in Local Languages
and Technical Support:
www.panduit.com
Page 1 of 1
Trim conductors flush using wire snipping tool.
1. Place plug in die until it clicks. Maintain pressure by pushing cable into plug.
2. Complete termination by closing the die set fully and releasing.