Conductor Sequence
Insertion Sequence
T568A T568B
1WH/GRN WH/ORG
2GRN ORG
3WH/ORG WH/GRN
4BLU BLU
5 WH/BLU WH/BLU
6ORG GRN
7 WH/BRN WH/BRN
8BRN BRN
INSTALLATION INSTRUCTIONS
Remove approximately 1.0" (25.4mm) of cable
jacket, untwist pairs and straighten conductors.
PN85L
Place conductors in proper sequence (see table at
left) and trim conductors to 7/16" (11mm) using wire
snipping tool (CWST).
Insert conductors individually in the proper
sequence (See above table).
Remove cable from conductor retention
slot, keeping conductors held in position by
placing thumb and forefinger at cable jacket
end.
Notes:
1. Panduit Crimp Tool MPT5-8AS recommended for crimping.
2. Terminates most 24-26 AWG stranded or solid conductor with an insulation diameter of 0.035" - 0.040".
3. For information on grounding and bonding refer to TIA/EIA 607.
As with all Wiring Accessories, the following statements apply:
1. Never install communications wiring during a lightning storm.
2. Never install communications wiring in wet locations unless the jack is specifically designed for use in wet locations.
3. Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface.
4. Use caution when installing or modifying communication wiring.
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
Pull conductors until cable jacket is at
conductor retention slot.
Place conductors in guide troughs, number
1-8 left to right with latch down as shown.
Apply slight downward pressure as you
insert conductors until they are fully
extended and under the plug contacts.
www.panduit.com
Page 1 of 1
Trim conductors flush using wire snipping
tool.
1. Place plug in die until it clicks.
Maintain pressure by pushing cable
into plug.
2. Complete termination by closing the
die set fully and releasing.