Category 5e 28-30 AWG Modular Plug
4
Orient cable
manager as
shown
8
1
7
Tr i m
conductors
flush
9
MPT5-8AS
Panduit recommends using MPT5-8AS
tool for use with Category 5e 28/30
AWG Plug termination.
Part Numbers: MP528, MP530
© Panduit Corp. 2013
MP528 Specifications
• Cable jacket diameter 0.140 - 0.160 in.
• 28 AWG stranded or solid conductor
maximum insulated diameter 0.024 in.
• Panduit recommends T568B wiring
Gauge
Identification
(clear)
scheme for use with cable constructed
with the brown pair opposing the
orange pair.
INSTALLATION INSTRUCTIONS
Wiring Sequence
8
Pin #
T568B BRN
T568A BRN
7
BRN/
WHT
BRN/
WHT
6
GRN
ORG
5
BLU/
WHT
BLU/
WHT
4
BLU
BLU
3
GRN/
WHT
ORG/
WHT
2
ORG
GRN
1
ORG/
WHT
GRN/
WHT
Gauge
Identification
(tinted)
PN547B
MP530 Specifications
• Cable jacket diameter 0.122 - 0.130 in.
• 30 AWG stranded maximum insulated
diameter 0.021 in.
• Panduit recommends T568B wiring
scheme for use with cable constructed
with the brown pair opposing the
orange pair.
www.panduit.com/resources/install_maintain.asp