MINI-COM RCA and S-Video
110 Style Punchdown Modules
Part Numbers: CJRY**, CJRR**, CJRW**, CJSV**
© Panduit Corp. 2007
INSTALLATION INSTRUCTIONS PN194D
TERMINATION INSTRUCTIONS
STEP 1
Remove approximately 1" of cable jacket. (CAUTION: Do not damage conductors.) Fan out twisted pairs
for termination.
STEP 2
Use the PDT110 Single Wire Punchdown tool to punchdown conductors in the orientation shown.
RCA Module
Signal Ground
Signal
Signal and Signal Ground use one twisted pair
S-Video Module
Chrominance
Chrominance Ground
Luminance Ground
Luminance
Chrominance and Chrominance Ground use one twisted pair
Luminance and Luminance Ground use one twisted pair
Modules should appear as shown below when terminated.
S-Video Module RCA Module
** Denotes color.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 1 of 2

INSTALLATION INSTRUCTIONS PN194D
STEP 3
Install the P110RC2 wire retention cap onto the connector block.
Modules should appear as shown below when completed.
S-Video Module RCA Module
OPTIONAL STEP
Use the optional AVPDB Punchdown Fixture Coin
to align and hold the module for termination.
Set module into fixture by aligning slot in module with tab on
fixture. Snap in place. Do not use connector block to snap in
place. To remove module from fixture, apply pressure to tab on
fixture, tilt module, and lift out.
Connector Block
INSTALLATION TIPS:
1. PAN-PUNCH product terminates most 22-26 AWG solid or stranded IWC wire with a .050" (1.27mm) max. o.d., either PVC or Plenum rated.
2. Never install wire into a slot previously used for a larger gauge.
3. Be careful to strip back cable jacket only as required for termination.
4. Use care to maintain pair twists to within 0.5 inches (13mm) of the termination strip.
5. When stripping cable jacket, be careful not to cut the insulation on the individual wires.
6. Avoid sharp bends when routing cable.
As with all Wiring Accessories, the following statements apply:
1. Never install communications wiring during a lightning storm.
2. Never install communications wiring in wet locations unless the product is specifically designed for use in wet locations.
3. Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface.
4. Use caution when installing or modifying communication wiring.