COPPER COMPRESSION CONNECTORS
C
Panduit Corp. 2016
INSTALLATION INSTRUCTIONS T-PMPI-62-PC
COPPER COMPRESSION CONNECTOR INSTALLATION
1. Use a connector marked for the wire size and wire material to be used. NEVER
use a copper connector on aluminum wire.
2. Strip wire insulation to approximate length shown on tool chart. DO NOT nick
or ring the conductor strands.
3. Clean the wire.
4. Insert stripped wire into connector until the wire stops.
5. Using installation tooling shown on other side, insert connector in die and crimp
between color bands or knurl markings. REQUIRED NUMBER OF
COMPRESSIONS SHOWN IN ( ).
6. After crimping, inspect for sharp edges, flash or burrs and remove if present.
HEAT SHRINK INSULATION INSTRUCTION
1. Refer to Panduit catalog or www.panduit.com for heat shrink material information,
tubing size, voltage rating, and shrink temperature.
2. Cut tubing to length allowing insulation coverage as desired. Allow a minimum
of 1-1/2" inch overlap on wire insulation.
3. Shrink with a standard propane torch or heat gun. MOVING FROM CRIMPED
PORTION OF CONNECTOR TOWARD INSULATED WIRE. Adhesive flow at
ends indicate shrinkage complete.
*Heat shrink insulation, blank tongues, & non-plated lugs not tested by TELCORDIA.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 1 of 4
Rev 10

C
Panduit Corp. 2016
Tool Chart for Compression ConnectorsType LCB, LCC, LCP, and SCL with Copper Cable
INSTALLATION INSTRUCTIONS T-PMPI-62-PC
Panduit Part
Number
L=Lug
S=Splice
LCB10
LCC10
SCL10
LCB8
LCC8
SCL8
LCB6
LCBN6
LCC6
LCCN6
SCL6
LCB4
LCBN4
LCC4
LCCN4
SCL4
LCB2
LCBN2
LCC2
LCCN2
SCL2
LCB1
LCBN1
LCC1
LCCN1
SCL1
LCB1/0
LCBN1/0
LCC1/0
LCCN1/0
SCL1/0
LCB2/0
LCBN2/0
LCC2/0
LCCN2/0
SCL2/0
LCB3/0
LCBN3/0
LCC3/0
LCCN3/0
SCL3/0
LCB4/0
LCBN4/0
LCC4/0
LCCN4/0
SCL4/0
LCB250
LCBN250
LCC250
LCCN250
SCL250
Std. Wire Size
AWG
#14 – #10 STR
#12 – #10 SOL
#8 STR
#8 SOL
#6 SOL
#6
#4 – #3 STR
#2 SOL
#2
#1
1/0
2/0
3/0
4/0
250 kcmil
Wire Strip
Length (in.)
9/16
3/4
7/8*
1-1/16
1-1/8
1-1/8
1-1/4
1-7/16
1-3/8
1-1/2
1-3/8
1-9/16
1-1/2
1-9/16
1-1/2
1-5/8
1-11/16
1-5/8
CT-2300/ST
CT-2300/STINT
1
P10
(2)
CT-2300/STAUS
CT-2300/STUK
CT-2300/TO
CD-570
12-10
(2)
CT-1570 CT-1701
12-10
(2)
— — — —
— — — —
— — — —
— — — —
— — — —
— — — — —
— — — — —
— — — — —
— — — — —
— — — — —
CT-600A
CT-570CH
12-10
(2)
CT-2920/CCP
CT-2600/L
(2)
(2)
(2)
(2)
(2)
(2)
(3)
(3)
(3)
(4)
CT-2600/LINT
CT-2600/LUK
CT-2600/LAUS
CT-2600/TO
KC4-8
Red
(1)
#8 STR
#8 SOL ONLY
KC4-6
Blue
(1)
KC4-4
Gray
(1)
KC4-2
Brown
(1)
KC4-1
Green
(1)
KC4-1/0
Pink
(1)
KC4-2/0
Black
(2)
KC4-3/0
Orange
(2)
KC4-4/0
Purple
(2)
KC4-250
Yellow
(2)
1
CT-1700
— — — — — — — —
Red P21
(3)
Blue P24
(3)
Gray P29
(3)
Brown P33
(3)
Green P37
(4)
CT-720
CD-720-1
Red P21
CD-720-1
Blue P24
CD-720-1
Gray P29
CD-720-1
Brown P33
CD-720-2
Green P37
CD-720-2
Pink P42
CD-720-2
Black P45
CD-720-2
Orange P50
CD-720-3
Purple P54
CD-720-3
Yellow P62
A
See Tool List
Below
CD-2001-8
Red P21
(2)
CD-2001-6
Blue P24
(2)
CD-2001-4
Gray P29
(2)
CD-2001-2
Brown P33
(2)
CD-2001-1
Green P37
(2)
CD-2001-1/0
Pink P42
(2)
CD-2001-2/0
Black P45
(3)
CD-2001-3/0
Orange P50
(3)
CD-2001-4/0
Purple P54
(3)
CD-2001-250
Yellow P62
(3)
See Tool List
Below
CD-920-8
Red P21
CD-920-6
Blue P24
CD-920-4
Gray P29
CD-920-2
Brown P33
CD-920-1
Green P37
CD-920-1/0
Pink P42
CD-920-2/0
Black P45
CD-920-3/0
Orange P50
CD-920-4/0
Purple P54
CD-920-250
Yellow P62
B
(1)
(1)
(1)
(1)
(1)
(2)
(3)
(3)
(3)
(3)
CT-2920/CCPINT
CT-2920/CCPUK
CT-2920/CCPAUS
CT-2920/CCPTO
CT-920CH/CCP
with UA12ID
Indenter Die
— —
— —
STD
(1)
STD
(1)
STD
(1)
STD
(1)
STD
(1)
STD
(1)
STD
(1)
STD
(1)
C
See Uni-Die™
Dieless Tools
Below
#4 – #2 AWG
#2 AWG
SOL Only
(1)
#6 – #2 AWG
(1)
#6 – #1 AWG
(1)
#6 – 1/0 AWG
(2)
#4 – 2/0 AWG
(2)
#2 – 3/0 AWG
(2)
#1 – 4/0 AWG
(2)
1/0 AWG –
250 kcmil
(3)
CT-3980
CT-3980/INT
CT-3980/UK
CT-3980/AUS
CT-3980/TO
Uni-Die™
Dieless Tool
STD
(1)
STD
(1)
STD
(1)
STD
(1)
STD
(1)
STD
(1)
STD
(1)
STD
(1)
STD
(1)
STD
(1)
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
www.panduit.com
Page 2 of 4
E-mail:
cs@panduit.com
Phone:
800-777-3300
Rev 10

C
Panduit Corp. 2016
INSTALLATION INSTRUCTIONS T-PMPI-62-PC
Tool Chart for Compression Connectors Type LCB, LCC, LCP, and SCL with Copper Cable
Panduit Part
Number
L=Lug
S=Splice
LCB300
LCBN300
LCC300
LCCN300
SCL300
LCB350
LCBN350
LCC350
LCCN350
SCL350
LCB400
LCBN400
LCC400
LCCN400
SCL400
LCB500
LCBN500
LCC500
LCCN500
LCP500
SCL500
LCB600
LCBN600
LCC600
LCCN600
SCL600
LCB750
LCBN750
LCC750
LCCN750
LCP750
SCL750
LCB800
LCBN800
LCC800
LCCN800
LCB1000
LCBN1000
LCC1000
LCCN1000
LCP1000
SCL1000
LCB1250
LCC1250
LCP1250
Std. Wire Size
AWG
300 kcmil
350 kcmil
400 kcmil
500 kcmil
600 kcmil
750 kcmil
800 kcmil
1000 kcmil
1250 kcmil
Wire Strip
Length (in.)
2-5/16
2
2-5/16
2
2-3/8
2-1/8
2-9/16
2-1/4
2-3/4
2-11/16
2-15/16
2-7/8
3
3-1/16
3
3-3/8
CT-2600/L
CT-720
CD-720-4
White P66
CD-720-5
Red P71
CD-720-6
Blue P76
CD-720-7
Brown P87
CT-2600/LINT
CT-2600/LUK
CT-2600/LAUS
CT-2600/TO
KC4-300
(4)
(4)
(4)
(4)
— —
— — —
— — —
— — —
— — —
White
(2)
—
—
—
A
See Tool List
Below
CD-2001-300
White P66
(3)
CD-2001-350
Red P71
(3)
CD-2001-400
Blue P76
(4)
CD-2001-500
Brown P87
(4)
***KC22-600B
Green
(4)
B
See Tool List Below
CD-920-300
White P66
(3)
CD-920-350
Red P71
(3)
CD-920-400
Blue P76
(3)
CD-920-500
Brown P87
(3)
CD-920-600
Green P94
(4)
CD-920-750
Black P106
(4)
Orange P107
(4)
White P125
(4)
Yellow P140
(4)
4
4
4
4
CD-940-750
CD-940-800
CD-940-1000
CD-940-1250
CT-2920/CCP
CT-2920/CCPINT
CT-2920/CCPUK
CT-2920/CCPAUS
CT-2920/CCPTO
CT-920CH/CCP
with UA12ID
Indenter Die
STD
(1)
STD
(1)
STD
(1)
STD
(1)
STD
(1)
STD
(1)
— — —
— — —
— — —
C
See Uni-Die™
Dieless Tools
Below
2/0 AWG –
300 kcmil
3/0 AWG –
350 kcmil
4/0 AWG –
400 kcmil
4/0 AWG –
500 kcmil
250 – 600
kcmil
500 – 750
kcmil
CT-3980
CT-3980/INT
CT-3980/UK
CT-3980/AUS
CT-3980/TO
Uni-Die™
Dieless Tool
STD
STD
STD
STD
STD
(1)
(1)
(1)
(1)
(1)
—
(3)
(3)
(3)
(3)
(3)
(3)
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
www.panduit.com
Page 3 of 4
E-mail:
cs@panduit.com
Phone:
800-777-3300
Rev 10

C
Panduit Corp. 2016
INSTALLATION INSTRUCTIONS T-PMPI-62-PC
Tool Chart for Compression Connectors Type LCB, LCC, LCP, and SCL with Copper Cable
Panduit Part Number
L=Lug
S=Splice
LCB1500
LCC1500
LCP1500
LCB2000
LCC2000
LCP2000
1
The crimp die pockets are integrated into the tool frame.
3
CD-920 dies can be used with CT-940CH and CT-2940 tools with die adapter
4
CD-940 dies to be used exclusively with CT-940CH series and CT-2940 series tools
5
Maximum size: 500 kcmil lugs and 250 kcmil splices.
6
Maximum size: 250 kcmil lugs and splices. No extended wire range.
9
Maximum size: 600 kcmil lugs and splices.
Std. Wire Size
AWG
1500 kcmil
2000 kcmil
Wire Strip Length (in.)
3-3/8
3-5/8
B
See Tool List Below
CD-940-1500
Green P150
(4)
—
Burndy Tool
Y60B
4
Burndy Die
L46RT
(3)
Burndy Die
L48RT
(4)
* LCC8-12 wire strip length is 7/8"
*** KC22-600B crimp die for used with CT-3001/ST and CT-3001/CCP series tools.
CT-2001, CT-2001/L, CT-2001/LE, CT-2002, CT-2002/L, CT-3001, CT-3001/E, CT-3001/ST, CT-3001/STINT, CT-3001/STUK, CT3001/STAUS, CT-3001/TO, CT-3001/CCP, CT-3001/CCPINT, CT-3001/CCPUK, CT-3001/CCPAUS, CT-3001/CCPTO
A
CT-920, CT-920/CV, CT-920CH, CT-920CH/CV, CT-920CH/CCP, CT-930, CT-930CH, CT-930LPCH
9
, CT-940CH/BJO3, CT-2920,
CT-2920/CCP, CT-2920/CCPINT, CT-2920/CCPUK, CT-2920/CCPAUS, CT-2920/CCPTO, CT-2930, CT-2930/L, CT2930/LE, CT-2931, CT-2931/ST,
CT-2931/STINT, CT-2931/STUK, CT-2931/STAUS, CT-2931/TO, CT-2931/STCV, CT-2931/STCVINT, CT-2931/STCVUK, CT-2931/STCVAUS,
B
CT-2931/CVTO, CT-2940
3
, CT-2940/L3, CT-2940/LE
3
CT-980, CT-980CH, CT-980LPCH6, CT-29505, CT-2980, CT-2980/L, CT-2980/LE, CT-2980/ST, CT-2980/STINT, CT-2980/STUK, CT2980/STAUS, CT-2980/TO, CT-2981, Extended Wire Range
C
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
www.panduit.com
Page 4 of 4
E-mail:
cs@panduit.com
Phone:
800-777-3300
Rev 10