IndustrialNet Category 6A RJ45 Field Terminable Plugs
Part Number: ISPS688FA for Ø1.0 - 1.6 mm / 0.039 - 0.063 inch CONDUCTOR INSULATION DIA.
70
S/FTP
1
min. 50mm
(min. 2 inch)
Fold back braid and
remove all foils
U/UTP
min. 50mm
(min. 2 inch)
Trim pair separator
if applicable
3 5
Wire manager WHITE for Ø1.0 - 1.6 mm
(0.039 - 0.063 inch) CONDUCTOR INSULATION DIA.
5 50
0 15
mm
U/FTP
min. 100mm (min. 4 inch)
min. 50mm
(min. 2 inch)
Remove all foils
Wrap drain wire
7 8
approx.
18mm
(0.7 inch)
Technical Support • Phone: 866-405-6654 • Email: techsupport@panduit.com • www.panduit.com PN591E
Part Number: ISPS688FAS for Ø0.85 - 1.0 mm / 0.033 - 0.039 inch CONDUCTOR INSULATION DIA.
SF/UTP
Fold back braid.
Score and remove foil
Trim pair separator
if applicable
min. 50mm
(min. 2 inch)
S/FTP, U/FTP and SF/UTP
Smooth wires before inserting into the wire manager
untwist and insert pairs into the wire manager
Wire manager can be brought to end
position by means of screen cover
2
1
Insert the wire manager
Wire manager GREY for Ø0.85 - 1.0 mm
(0.033 - 0.039) inch
CONDUCTOR INSULATION DIA.
9
Press down evenly with parallel
jaw pliers
86 03 250) to snap housing parts
together
2
(cable end 1)
5mm
(0.2 inch) (0.2 inch)
Presort pairs. Remove pair screen
to 5mm (0.2 inch) max.
(cable end 2)
T568B
4
Center Tool jaws on top and bottom
wire managers during crimping.
Press down evenly with parallel
pliers (required tool, Knipex P.N.:
jaw
86 03 250)
Adjustable cable strain relief.
1
3
(required tool, Knipex P.N.:
(cable end 1)
5mm
Presort pairs. Remove pair screen
to 5mm (0.2 inch) max.
(cable end 2)
T568A
Cut all wires
protruding
0.5mm (0.02 inch) max.
Note: for T568A,
green and orange
pairs will not match
the wire manager
6
Remove assembly aid
Color code
2
4
T568
A B
W - G W - O 1
G O 2
W - O W - G 3
BL BL 4
W - BL W - BL 5
O G 6
W - BR W - BR 7
BR BR 8
RJ45
PIN No.