Panduit ISPS688FAS Installation Manual

Page 1
IndustrialNet Category 6A RJ45 Field Terminable Plugs
Part Number: ISPS688FA for Ø1.0 - 1.6 mm / 0.039 - 0.063 inch CONDUCTOR INSULATION DIA.
70
S/FTP
min. 50mm
(min. 2 inch)
Fold back braid and remove all foils
U/UTP
min. 50mm
(min. 2 inch)
Trim pair separator if applicable
3 5
Wire manager WHITE for Ø1.0 - 1.6 mm (0.039 - 0.063 inch) CONDUCTOR INSULATION DIA.
5 50
0 15
mm
U/FTP
min. 100mm (min. 4 inch)
min. 50mm
(min. 2 inch)
Remove all foils
Wrap drain wire
7 8
approx.
18mm
(0.7 inch)
Technical Support • Phone: 866-405-6654 • Email: techsupport@panduit.com • www.panduit.com PN591E
Part Number: ISPS688FAS for Ø0.85 - 1.0 mm / 0.033 - 0.039 inch CONDUCTOR INSULATION DIA.
SF/UTP
Fold back braid. Score and remove foil
Trim pair separator if applicable
min. 50mm
(min. 2 inch)
S/FTP, U/FTP and SF/UTP
Smooth wires before inserting into the wire manager
untwist and insert pairs into the wire manager
Wire manager can be brought to end position by means of screen cover
2
1
Insert the wire manager
Wire manager GREY for Ø0.85 - 1.0 mm (0.033 - 0.039) inch
CONDUCTOR INSULATION DIA.
Press down evenly with parallel jaw pliers 86 03 250) to snap housing parts
together
(cable end 1)
5mm
(0.2 inch) (0.2 inch)
Presort pairs. Remove pair screen to 5mm (0.2 inch) max.
(cable end 2)
T568B
Center Tool jaws on top and bottom wire managers during crimping.
Press down evenly with parallel
pliers (required tool, Knipex P.N.:
jaw 86 03 250)
Adjustable cable strain relief.
1
3
(required tool, Knipex P.N.:
(cable end 1)
5mm
Presort pairs. Remove pair screen to 5mm (0.2 inch) max.
(cable end 2)
T568A
Cut all wires protruding
0.5mm (0.02 inch) max.
Note: for T568A, green and orange pairs will not match the wire manager
Remove assembly aid
Color code
2
4
T568
A B
W - G W - O 1
G O 2
W - O W - G 3
BL BL 4
W - BL W - BL 5
O G 6
W - BR W - BR 7
BR BR 8
RJ45
PIN No.