Panduit IndustrialNet IAEBHUSBAA Installation Instructions Manual

Bulkhead with
Nut
Tether with Cap
Coupler
Face Seal
Bulkhead
Seal
Module
IndustrialNetTM USB Coupler Module
3
Rounded
Click
4
Edges
(Enclosure wall removed for clarity)
1
2
Bulkhead Opening Requirements
Ø 1-13/64"
(30.6mm)
1-7/8" (47.6)
1-7/8" (47.6)
Enclosure Wall
Insert Bulkhead into prepared opening from outside of enclosure. While holding Bulkhead in place, secure with Nut on inside of enclosure. Hand turn Nut 4-1/4 to 5 full turns. Be careful not to tighten to the point the Bulkhead Seal is over compressed and displaced from the enclosure wall and the Bulkhead. Note: If using wrench, flats on Nut should be on the outside.
Inside of Enclosure Outside of Enclosure
or Outlet Plate
Min. thickness: 0.035" (20 gauge) Max. thickness: 0.135" (10 gauge)
Bulkhead
Seal
{not to scale}
Part Number: IAEBHUSBAA
© Panduit Corp. 2018
Note: Bulkhead combination must be used on a flat surface of a NEMA 4X Enclosure to maintain rating.
INSTALLATION INSTRUCTIONS
PN556B
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 1 of 2
© Panduit Corp. 2018
3
1
2
Click
INSTALLATION INSTRUCTIONS
Coupler Module Removal Instructions
PN556B
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
www.panduit.com
Page 2 of 2
E-mail:
techsupport@panduit.com
Phone:
866-405-6654