![](/html/53/53aa/53aa41c9b171fa0732808c33dc20959faf3057b097613e384721bdb4ee217226/bg1.png)
Bulkhead with
Nut
USB
Tether with
Cap
Coupler
Face Seal
Bulkhead
Seal
Module
IndustrialNetTM USB Coupler Module
3
Rounded
Click
4
Edges
(Enclosure wall removed for clarity)
1
2
Bulkhead Opening Requirements
Ø 1-13/64"
(30.6mm)
1-7/8"
(47.6)
1-7/8"
(47.6)
Enclosure Wall
Insert Bulkhead into prepared opening from outside of
enclosure. While holding Bulkhead in place, secure with
Nut on inside of enclosure. Hand turn Nut 4-1/4 to 5 full turns. Be careful not
to tighten to the point the Bulkhead Seal is over compressed and displaced
from the enclosure wall and the Bulkhead.
Note: If using wrench, flats on Nut should be on the outside.
Inside of Enclosure Outside of Enclosure
or Outlet Plate
Min. thickness: 0.035" (20 gauge)
Max. thickness: 0.135" (10 gauge)
Bulkhead
Seal
{not to scale}
Part Number: IAEBHUSBAA
© Panduit Corp. 2018
Note: Bulkhead combination must be used on a flat surface of a NEMA 4X Enclosure to maintain rating.
INSTALLATION INSTRUCTIONS
PN556B
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 1 of 2
![](/html/53/53aa/53aa41c9b171fa0732808c33dc20959faf3057b097613e384721bdb4ee217226/bg2.png)
© Panduit Corp. 2018
INSTALLATION INSTRUCTIONS
Coupler Module Removal Instructions
PN556B
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
www.panduit.com
Page 2 of 2
E-mail:
techsupport@panduit.com
Phone:
866-405-6654