Panduit FMT1J, FMT1J6HWBUDSC, FMT1J4HWBUDSC, FMT1J8HWBUDSC, FMT1J12HWBUDSC Installation Instructions Manual

...
Page 1
Fiber Optic Connector Enclosures for Japan
Part Numbers: FMT1J, FMT1J4HWBUDSC, FMT1J6HWBUDSC, FMT1J8HWBUDSC, FMT1J12HWBUDSC, FMT2J, FMT2J24HWBUDSC, FMT2J16HWBUDSC, FMT2J18HWBUDSC, FMT2J20HWBUDSC
© Panduit Corp. 2014
FMT1J
FMT1J4HWBUDSC FMT1J8HWBUDSC
FMT2J FMT2J24HWBUDSC
INSTALLATION INSTRUCTIONS
FMT1J6HWBUDSC FMT1J12HWBUDSC
FMT2J20HWBUDSCFMT2J18HWBUDSCFMT2J16HWBUDSC
FS066
Contents:
1 - Enclosure 4 - Strain Relief 2 - Brackets 2 - Short Grommets (FMT1J) 2 - Long Grommets (FMT2J)
4 - Grounding Lug 4 - M6 Screws 4 - M5 Screws with Flat Washers 4 - M5 Black Oxide Nut & Flat Washer 8- PLT2S Cable Tie
1 - Splice Tray without Cover (FMT1J12HWBUDSC) 1 - Fiber Caution Label 1 - Fiber Laser Beam Warning Label 5 - Wire Retainers
4 - #12-24 Screws 1- Splice Tray with Cover (FMT1J, FMT1J6HWBUDSC and FMT1J12HWBUDSC)
CAUTION:
Fiber optic cable is sensitive to excessive pulling, bending and crushing forces. Consult the manufacturer’s cable specification sheet for the specific cable in use.
Follow TIA/EIA 568-A, 569, 606, and 607 installation guidelines where applicable.
DANGER: UNMATED CONNECTORS MAY EMIT INVISIBLE LASER RADIATION. DO NOT LOOK DIRECTLY INTO THE END OF THE CONNECTOR, DO NOT INSPECT WITH MAGNIFYING DEVICES. MAINTAIN CAP ON UNMATED CONNECTORS.
ASSEMBLY
(FMT1J shown)
Bracket
Adapter panel
(FAP3HWBUDSC shown)
Wire retainer
M5 screw
with flat washer
M6 screw
#12-24 screw
Cable Tie
M5 black oxide nut
and flat washer
1RU grommet
Fiber Caution Label
Fiber laser beam
warning label
Cover
Grounding lug
Splice tray cover
Splice tray
Strain relief
Enclosure
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 1 of 4
Page 2
© Panduit Corp. 2014
DISCARD
DISCARD
INSTALLATION INSTRUCTIONS
FS066
Plunger
Flush enclosure bracket installation on 19" rack
Part Number
FMT1J4 FMT1J6 FMT1J8 FMT1J12
FMT2J16 FMT2J18 FMT2J20 FMT2J24
Recessed enclosure bracket installation on 19" rack
Note: Enclosure comes with the brackets installed in the recessed position.
FAP*HWBUDSC
2 2 0 4 0
8 0 1 0
3 0 2 0 4
0 6 6 8
Cut the small circle for 1" diameter innerduct
Cut the large circle for the 1-1/2" diameter innerduct
Grommet knockout
Strain Relief knockout
Cut the straight lines when not using any innerduct
If you utilize cable entry through a grommet knockout location, use pliers to grip the knockout and twist to remove.
To remove strain relief knockout, strike the knockout disk with a screwdriver and remove disk. Install strain relief.
Determine which grommet(s) will be used to bring the cable into the enclosure. Follow the diagram for cutting locations.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 2 of 4
Page 3
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
Enclosure mounts to rack with the M5 screws and flat washers, M6 screws, or #12-24 screws provided.
FS066
Grounding Lug
Insert cable through appropriate entry location. Strip one meter of jacket from the end of the cable. Secure the jacketed cable to the grounding lug. Tighten strain relief to seal cable.
Strain Relief
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 3 of 4
Page 4
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
Splice Connection
FS066
Gently route excess fiber through the splice tray following the bend radius control staying under the guide tabs.
Wire retainers and cable ties are provided to secure the cable within the enclosure.
Guide Tab
Bend Radius Control
Splice cables per manufacturers instructions.
Slide cover forward and secure with M5 screw. Affix fiber caution label and fiber laser beam warning label where they are clearly visible.
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
www.panduit.com
Page 4 of 4
E-mail:
techsupport@panduit.com
Phone:
866-405-6654
Loading...