Panduit FCE1 Installation Manual

Page 1
Opticom Rack Mount Fiber Enclosure
Part Number: FCE1
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
FCE1
Contents:
1 ENCLOSURE 5 TAK-TY HOOK AND LOOP STRIPS 4 PAN-TY CABLE TIES 2 SLACK SPOOLS 1 #10-32 X 3/8" SCREW
CAUTION:
Fiber optic cable is sensitive to excessive pulling, bending and crushing forces. Consult the manufacturer’s cable specification sheet for the specific cable in use.
Follow TIA/EIA 568-A, 569, 606, and 607 installation guidelines where applicable.
DANGER: UNMATED CONNECTORS MAY EMIT INVISIBLE LASER RADIATION. DO NOT LOOK DIRECTLY INTO THE END OF THE CONNECTOR, DO NOT INSPECT WITH MAGNIFYING DEVICES. MAINTAIN CAP ON UNMATED CONNECTORS.
2 FIBER GROMMETS 1 #10-32 ACORN NUT 4 #M6X1 SCREWS 1 STRAIN RELIEF BRACKET
2 BEND RADIUS CONTROL CLIPS 4 #12-24 X 1/2" SCREWS 1 CAUTION LABEL 1 LASER WARNING LABEL
FS060
ASSEMBLY
Space/pad for optional splice chip
Enclosure
Port identification label
Strain relief bracket
Spool
Grommet
Bend radius bracket
Laser warning label
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 1 of 4
Page 2
© Panduit Corp. 2014
Cut the small circle for 1" diameter innerduct
Cut the large circle for 1-1/2" diameter innerduct
Cut the straight lines when not using any innerduct
DISCARD
DISCARD
INSTALLATION INSTRUCTIONS
To remove the cover, unscrew the two #10-32 screws and slide the cover backward until it slides off of the rear of the enclosure.
Determine which grommet(s) will be used to bring the cable into the enclosure. Remove the knock-out at entry location of the fiber tray. Install grommet following the proper cutting diagram.
FS060
Place the strain relief bracket near area where the cable will enter the enclosure. Fasten with #10-32 screw and hex nut.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 2 of 4
Page 3
© Panduit Corp. 2014
1
2
To remove the bend radius bracket, disengage latch with a screwdriver
Spool locations
Mounting Instruction
(4)12-24 X 1/2" screws (provided)
INSTALLATION INSTRUCTIONS
Spool orientation
FS060
Ensure vertical fingers of spools are oriented in position and location shown to ensure maximum routing capacity of the spools. Remove the liner from the tape on each spool and place them inside the enclosure
Mount the enclosure to the rack using (4) #12-24 screws.
Slot
To install the bend radius brackets, slide the bracket onto tab with the slot facing forward then snap in place.
To lock drawer in closed position use acorn nut.
Acorn nut
Insert the cassette into the enclosure as shown. Once mounted, push the latches in to secure the cassette.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 3 of 4
Page 4
© Panduit Corp. 2014
Tray closed
Tak-Ty spooling loop
Tray open
INSTALLATION INSTRUCTIONS
FS060
Route fiber through grommet to fiber cassettes as shown. Use provided Tak-Ty to secure fiber cords at cable entry location. Leave slack loop as shown to ensure proper drawer movement without damaging fiber cords.
Slack loop
To install the cover, slide the cover forward and screw the two #10-32 screws in hole locations shown.
Install front cover with spring hinge as shown.
Attach Laser Warning Label and Caution Label where they are clearly visible.
Ensure that a one foot slack loop is left in the vertical channel to allow proper drawer movement
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
www.panduit.com
Page 4 of 4
E-mail:
techsupport@panduit.com
Phone:
866-405-6654