Opticom Rack Mount Fiber Enclosure
Part Number: FCE1
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
FCE1
Contents:
1 ENCLOSURE
5 TAK-TY HOOK AND LOOP STRIPS
4 PAN-TY CABLE TIES
2 SLACK SPOOLS
1 #10-32 X 3/8" SCREW
CAUTION:
Fiber optic cable is sensitive to excessive pulling, bending and crushing forces. Consult the manufacturer’s cable specification sheet
for the specific cable in use.
Follow TIA/EIA 568-A, 569, 606, and 607 installation guidelines where applicable.
DANGER: UNMATED CONNECTORS MAY EMIT INVISIBLE LASER RADIATION. DO NOT LOOK DIRECTLY INTO THE END OF
THE CONNECTOR, DO NOT INSPECT WITH MAGNIFYING DEVICES. MAINTAIN CAP ON UNMATED CONNECTORS.
2 FIBER GROMMETS
1 #10-32 ACORN NUT
4 #M6X1 SCREWS
1 STRAIN RELIEF BRACKET
2 BEND RADIUS CONTROL CLIPS
4 #12-24 X 1/2" SCREWS
1 CAUTION LABEL
1 LASER WARNING LABEL
FS060
ASSEMBLY
Space/pad for optional
splice chip
Enclosure
Port identification label
Strain relief
bracket
Spool
Grommet
Bend radius bracket
Laser warning label
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 1 of 4

© Panduit Corp. 2014
Cut the small circle
for 1" diameter
innerduct
Cut the large circle
for 1-1/2" diameter
innerduct
Cut the straight
lines when not
using any
innerduct
INSTALLATION INSTRUCTIONS
To remove the cover, unscrew the two #10-32
screws and slide the cover backward until it slides
off of the rear of the enclosure.
Determine which grommet(s) will be used to bring
the cable into the enclosure. Remove the knock-out
at entry location of the fiber tray. Install grommet
following the proper cutting diagram.
FS060
Place the strain relief bracket near area where the
cable will enter the enclosure. Fasten with #10-32
screw and hex nut.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 2 of 4

© Panduit Corp. 2014
To remove the bend radius
bracket, disengage latch with
a screwdriver
Spool locations
Mounting Instruction
(4)12-24 X 1/2" screws (provided)
INSTALLATION INSTRUCTIONS
Spool orientation
FS060
Ensure vertical fingers of spools are oriented in
position and location shown to ensure maximum
routing capacity of the spools. Remove the liner
from the tape on each spool and place them
inside the enclosure
Mount the enclosure to the rack using (4) #12-24
screws.
Slot
To install the bend radius brackets, slide the
bracket onto tab with the slot facing forward then
snap in place.
To lock drawer in closed position use acorn nut.
Acorn nut
Insert the cassette into the enclosure as
shown. Once mounted, push the latches in to
secure the cassette.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 3 of 4

© Panduit Corp. 2014
Tray closed
Tak-Ty spooling
loop
Tray open
INSTALLATION INSTRUCTIONS
FS060
Route fiber through grommet to fiber cassettes as
shown. Use provided Tak-Ty to secure fiber cords
at cable entry location. Leave slack loop as shown
to ensure proper drawer movement without
damaging fiber cords.
Slack loop
To install the cover, slide the cover forward and
screw the two #10-32 screws in hole locations
shown.
Install front cover with spring hinge as shown.
Attach Laser Warning Label and Caution Label
where they are clearly visible.
Ensure that a one foot slack loop is left in the
vertical channel to allow proper drawer movement
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
www.panduit.com
Page 4 of 4
E-mail:
techsupport@panduit.com
Phone:
866-405-6654