Panduit F92ERQ1Q1SNM001 Selection Guide

Panduit HD Flex™ Fiber Cabling System: Built for Next-Generation Density Demands.
The HD Flex™ Fiber Cabling System is engineered to provide the highest levels of density and serviceability for high-performance data centers. The system is purposely designed to enable organizations to easily scale up density and execute moves, adds and changes quickly and safely, without disrupting adjacent circuits.
Technicians can take advantage of the unique benets provided by the HD Flex
• Innovative cable management that positions trunk cables away from the rear of the enclosure, providing enhanced access for moves, adds, and changes
• Split trays inside the enclosure support safe moves, adds, and changes
• Cassettes accessible from the front or back to streamline installation and migrations from 10G to 40G/100G Ethernet and beyond
• Convertible enclosures and panels that accommodate 4-port, 6-port, and/or 12-port cassettes
2
visit www.panduit.com/hdflex
Cabling System.
HD Flex™ Enclosures, Panels, and Zero RU Bracket
FLEX4U04
FLEX1UPN04
FLEX1U06
FLEX1UPN06
FLEX-0RUBR06
FLEX1U12
FLEX1UPN12
Part Number Description
HD Flex
4-Port Fiber Enclosures, Panels, and Zero RU Bracket
Enclosures
FLEX1U04 1 RU HD Flex
FLEX2U04 2 RU HD Flex
FLEX4U04 4 RU HD Flex
4-Port Enclosure. 18
4-Port Enclosure. 36
4-Port Enclosure. 72
Panels
FLEX1UPN04 1 RU HD Flex
FLEX2UPN04 2 RU HD Flex
FLEX4UPN04 4 RU HD Flex
4-Port Panel. 18
4-Port Panel. 36
4-Port Panel. 72
Zero RU Cassette Holder and Bracket
FLEX-0RUBR04 HD Flex
FLEX-0RUCH04 HD Flex
0 RU 4-Port Bracket and Cassette Holder. 3
0 RU 4-Port Cassette Holder.
HD Flex™ 6-Port Fiber Enclosures, Panels, and Zero RU Bracket
Enclosures
FLEX1U06** 1 RU HD Flex
FLEX2U06** 2 RU HD Flex
FLEX4U06** 4 RU HD Flex
6-Port Enclosure. 12
6-Port Enclosure. 24
6-Port Enclosure. 48
Panels
FLEX1UPN06** 1 RU HD Flex
FLEX2UPN06** 2 RU HD Flex
FLEX4UPN06** 4 RU HD Flex
6-Port Panel. 12
6-Port Panel. 24
6-Port Panel. 48
Zero RU Cassette Holder and Bracket
FLEX-0RUBR06** HD Flex
FLEX-0RUCH06 HD Flex
0 RU 6-Port Bracket and Cassette Holder. 2
0 RU 6-Port Cassette Holder.
HD Flex™ 12-Port Fiber Enclosures, Panels, and Zero RU Bracket
Enclosures
FLEX1U12 1 RU HD Flex
FLEX2U12 2 RU HD Flex
FLEX4U12 4 RU HD Flex
12-Port Enclosure. 6
12-Port Enclosure. 12
12-Port Enclosure. 24
Panels
FLEX1UPN12 1 RU HD Flex
FLEX2UPN12 2 RU HD Flex
FLEX4UPN12 4 RU HD Flex
12-Port Panel. 6
12-Port Panel. 12
12-Port Panel. 24
Zero RU Cassette Holder and Bracket
FLEX-0RUBR12 HD Flex
FLEX-0RUCH12 HD Flex
**Offered in White (add WH to Part Number for White).
0 RU 12-Port Bracket and Cassette Holder. 1
0 RU 12-Port Cassette Holder.
Cassette/FAP
Openings
HD Fusion Splicing Enclosure
Part Number Description
FRMHSS-4RU HD-Fusion – ber rack mount hyperscale splicing solution 4 RU that can splice
FST48 Fiber splice tray kit for up to 48 mechanical or fusion splices for use in
FRMHSS-4RU
FST144R Fiber splice tray kit for up to 144 ribbon fusion splices for use in
up to 576 single bers and 864 ribbon bers.
Panduit FRMHSS-4RU.
Panduit FRMHSS-4RU.
visit www.panduit.com/hdflex
3
HD Flex™ Fiber Optic Cassettes
FHCZO-12-10AS
FHCXO-24-10AN
FHCXO-24F-10AS
Part Number
HD Flex
6-port
FHCXO-12-10** OM3 12 6 1 x 12f 6 Optimized
FHCXA-12-10** OM3 12 6 1 x 12f 6 Ultra
FHCZO-12-10** OM4 12 6 1 x 12f 6 Optimized
FHCZA-12-10** OM4 12 6 1 x 12f 6 Ultra
FHCSA-12-10** OM4+ 12 6 1 x 12f 6 Ultra
FHCWA-12-10** OM5+ 12 6 1 x 12f 6 Ultra
FHC9N-12-10** OS2 12 6 1 x 12f 6 Standard
** AS for Method A, AF for Modied Method A (pair ipped), BN for Method B, U for Universal
12-Port
FHCXO-24-10** OM3 24 12 2 x 12f 12 Optimized
FHCXA-24-10** OM3 24 12 2 x 12f 12 Ultra
FHCZO-24-10** OM4 24 12 2 x 12f 12 Optimized
FHCZA-24-10** OM4 24 12 2 x 12f 12 Ultra
FHCSA-24-10** OM4+ 24 12 2 x 12f 12 Ultra
FHCWA-24-10** OM5+ 24 12 2 x 12f 12 Ultra
FHC9N-24-10** OS2 24 12 2 x 12f 12 Standard
** AS for Method A, AF for Modied Method A (pair ipped), BN for Method B, U for Universal
FHCXO-24F-10A OM3 24 12 1 x 24f 12 Optimized
FHCZO-24F-10A OM4 24 12 1 x 24f 12 Optimized
FHC9N-24F-10A
LC/MPO Cassettes
Fiber
Type
OS2 24 12 1 x 24f 12 Standard
Fiber
Count
Port
Count
Number of
MPO's
Number of
Duplex LC's Performance
4
visit www.panduit.com/hdflex
HD Flex™ Fiber Optic Cassettes (continued)
FHC3ZO-08H-10B
FHC39N-08-10AN
FHC3ZO-24H-10A
Part Number
HD Flex™ 4-to-1 Conversion Cassettes
4 Port
FHC3XO-08H-10* OM3 8 4 1x8f 4 Optimized
FHC3ZA-08H-10* OM4 8 4 1x8f 4 Ultra
FHC3ZO-08H-10* OM4 8 4 1x8f 4 Optimized
FHC39N-08H-10* OS2 8 4 1x8f 4 Standard
* = A for Method A, B for Method B
6 Port
FHC3XO-08-10* OM3 8 4 1x8f 4 Optimized
FHC3ZA-08-10* OM4 8 4 1x8f 4 Ultra
FHC3ZO-08-10* OM4 8 4 1x8f 4 Optimized
FHC39N-08-10* OS2 8 4 1x8f 4 Standard
* = A for Method A, B for Method B/Universal
12 Port
FHC3XO-24H-10* OM3 24 12 3x8f 12 Optimized
FHC3ZA-24H-10* OM4 24 12 3x8f 12 Ultra
FHC3ZO-24H-10* OM4 24 12 3x8f 12 Optimized
FHC39N-24H-10* OS2 24 12 3x8f 12 Standard
* = A for Method A, B for Method B/Universal
Fiber
Type
Fiber
Count
Port
Count
Number of
Rear MPO's
Number of
Front
Duplex LC's Performance
(continued on next page)
visit www.panduit.com/hdflex
5
HD Flex™ Fiber Optic Cassettes (continued)
FHCXO-24F-10AS
FHCZU-48-NMNMA
FHSXO121OR
Part Number
100GBASE-SR10 and SR12 Breakout Cassettes
12 Port
FHCXO-20F-10A OM3 20 10 1 x 20f 10 Optimized
FHCZO-20F-10A OM4 20 10 1 x 20f 10 Optimized
FHC9N-20F-10A OS2 20 10 1 x 20f 10 Standard
FHCXO-24F-10A OM3 24 12 1 x 24f 12 Optimized
FHCZO-24F-10A OM4 24 12 1 x 24f 12 Optimized
FHC9N-24F-10A OS2 24 12 1 x 24f 12 Standard
Part Number
HD Flex™ Dark Fiber Conversion Cassettes
FH4ZU-24-NMNM* OM4 24 12 2x12f 3x8f Ultra
FH4ZU-48-NMNM* OM4 48 12 4x8f 6x8f Ultra
* = A for Method A, B for Method B.
Part Number
HD Flex™ Splice Cassettes
FHSXN-12-10* OM3 12 6 6 Standard
FHSXO-12-10* OM3 12 6 6 Optimized
FHSZO-12-10* OM4 12 6 6 Optimized
FHS9N-12-10* OS2 12 6 6 Standard
** P for 250um pigtails, R for ribbon pigtails.
Fiber
Type
Fiber
Type
Fiber
Type
Fiber
Count
Fiber
Count
Fiber
Count
Port
Count
Port
Count
Port
Count
Number of
Rear MPO's
Number of
Rear MPO's
Number of
Duplex Lc's Performance
Number of
Front
Duplex LC's Performance
Number of
Front MPO's Performance
6
visit www.panduit.com/hdflex
Part Number
HD Flex™ TAP Cassettes
FHCT-5ZUB OM4 1 MPO (Rear) 6 Duplex LC
FHCT-7ZUB OM4 1 MPO (Rear) 6 Duplex LC
FHCT-5ZUC OM4 2 Duplex LC
FHCT-7ZUC OM4 2 Duplex LC
FHCT-5ZUFB OM4
Fiber
Type
(BiDi TAP)
Live (In)
Ports
(Front)
(Front)
1 Duplex LC
(Front)
Live (Out
Ports
(Front)
(Front)
2 Duplex LC
(Front)
2 Duplex LC
(Front)
1 Duplex LC
(Front)
TAP
Ports
1 MPO (Rear) 50/50
1 MPO (Rear) 70/30
2 Duplex LC
(Front)
2 Duplex LC
(Front)
2 Duplex LC
(Front)
Split
Ratio
50/50
70/30
50/50
HD Flex™ Adapter Panel and Accessories
Part Number Description
HD Flex™ LC and MPO Fiber Adapter Panels and Blanking Panels
LC Fiber Adapter Panels + A135: B183
FHSXN-12-10N 6 LC duplex multimode adapters in Aqua with zirconia sleeves.
FHS9N-12-10N 6 LC duplex multimode adapters in Blue with zirconia sleeves.
FHSXN-12-10N
FHMP-6-ABL
FHSBBL06W
MPO Fiber Adapter Panels
FHMP-6-ABL 6 MPO type A adapters (key-Up to key-down) in Black.
FHMP-6-BCG 6 MPO type B adapters (key-Up to key-up) in Charcoal Gray.
FHMP-6-ARD 6 MPO type A adapters (key-Up to key-down) in Red.
Blanking Panels
FHSBBL06W HD Flex™ Blanking Panel for 6-port enclosures and panels.
Rail Kits for Enclosures
FLEX-RAIL04EN HD Flex™ 4 port Enclosure rail kit, 1 RU, 12 rails, 36 labels.
FLEX-RAIL06EN HD Flex™ 6 port Enclosure rail kit, 1 RU, 6 rails, 12 labels.
Rail Kits for Panels
FLEX-RAIL04PN HD Flex™ 4-Port Panel Rail kit, 1 RU, 12 rails.
FLEX-RAIL06PN HD Flex™ 6-Port Panel Rail kit, 1 RU, 6 rails.
(continued on next page)
visit www.panduit.com/hdflex
7
HD Flex™ Adapter Panel and Accessories (continued)
Part Number Description
HD Flex™ Adapter Cable Management and Accessories
Rear Cable Manager
FLEX-RCM1U
FLEX-FCM1UA
FLEX-PLATE1U
FLEX-CLIP12
FLEX-CM18S
FLEX-CM-1UB
FLEX-OPTI-1RU
FLEX-RCM1U** 1 RU HD Flex™ Rear Cable Manager.
FLEX-RCM4U** 4 RU HD Flex™ Rear Cable Manager.
Front Cable Manager
FLEX-FCM1UA** 1 RU HD Flex™ Front Cable Manager.
FLEX-FCM2UA** 2 RU HD Flex™ Front Cable Manager.
FLEX-FCM4UA** 4 RU HD Flex™ Front Cable Manager.
HD Flex Plate
FLEX-PLATE1U** HD Flex™ Enclosure Trunk Slack Plate 1 RU.
FLEX-PLATE2U** HD Flex™ Enclosure Trunk Slack Plate 2 RU.
FLEX-PLATE4U** HD Fle™x Enclosure Trunk Slack Plate 4 RU.
HD Flex Rear Cover Kit for Enclosures
FLEX-PLATE1UR HD Flex™ Enclosure Trunk Slack Plate with rear cover – 1 RU.
FLEX-PLATE2UR HD Flex™ Enclosure Trunk Slack Plate with rear cover – 2 RU.
FLEX-PLATE4UR HD Flex™ Enclosure Trunk Slack Plate with rear cover – 4 RU.
HD Flex Rear Cover Kit for Panels
FLEX-PLATE1UPR HD Flex™ Patch Panel Trunk Slack Plate with rear cover – 1 RU.
FLEX-PLATE2UPR HD Flex™ Patch Panel Trunk Slack Plate with rear cover – 2 RU.
FLEX-PLATE4UPR HD Flex™ Patch Panel Trunk Slack Plate with rear cover – 4 RU.
HD Flex Trunk Transition Clips
FLEX-CLIP12 HD Flex™ Trunk Transition Clip (quantity 2); 12 position.
FLEX-CLIP18 HD Flex™ Trunk Transition Clip (quantity 2); 18 position.
Universal Cable Managers
FLEX-CM12S HD Flex™ Universal Rear Cable Manager includes FLEX-CLIP12.
FLEX-CM18S HD Flex™ Universal Rear Cable Manager includes FLEX-CLIP18.
FLEX-CM12C HD Flex™ Universal Rear Cable Manager for PEV12 includes 2 FLEX-CLIP12.
FLEX-CM18C HD Flex™ Universal Rear Cable Manager for PEV12 includes 2 FLEX-CLIP18.
Universal Cable Manager Mounting Brackets
FLEX-CM-1UB HD Flex™ Universal Expandable Cable Management Bracket (front to back of
cabinet or 4 post rack).
FLEX-CM-1UBKIT HD Flex™ Cable Management 1 RU Universal Bracket 19" Kit
(2 FLEX-CM-1UB and horizontal strain relief bar)
HD Flex Conversion Bracket
FLEX-OPTI-1RU HD Flex™ Bracket Adapter for Opticom Enclosures 1 RU.
**Offered in White (add WH to Part Number for White).
8
visit www.panduit.com/hdflex
HD Flex™ Trunk Assemblies
part number
Example: FXUYP7575XNF030 - OM3 24-ber indoor trunk, plenum, PanMPO™ Female to PanMPO™ Female, 39" break­outs with HD Flex™ transitions, Method A polarity, optimized IL., no pulling eye, 30 feet.
CHARACTER
EXAMPLE
1 – Fiber
F = Fiber 2 –
Fiber Type
9 = OS2 9/125um X = OM3 50/125µm
Z = OM4 50/125µm
3 – Fiber Count
T = 12 fiber U = 24 fiber
4 – Cable Type
Y = Indoor small diameter trunk cable
5 – Jacket Type
L = Low Smoke Zero Halogen (LSZH) P = Plenum (OFNP)
1
2
F
X3U4Y5P67
7
8
9510X11N12
5
7
6 – Connector Type (End 'A') 5 = Singlemode MPO Female
6 = Singlemode MPO Male 7 = Multimode PanMPO Female 8 = Multimode PanMPO Male
7 – Connector Variant (End 'A')
5 = 39" Breakout with transition
8 – Connector Type (End 'B') 5 = Singlemode MPO Female
6 = Singlemode MPO Male 7 = Multimode PanMPO Female 8 = Multimode PanMPO Male
9 – Connector Variant (End 'B') 5 = 39" Breakout with transition
14
13
F
10 – Construction/Performance
A = Singlemode Polarity A - Standard IL X = Multimode Polarity A - Optimized IL Y = Multimode Polarity B - Optimized IL K = Multimode Polarity A - Ultra Low IL L = Multimode Polarity B - Ultra Low IL
11 – Other
N = No pulling eye (15 - 100ft, 5 - 30m) A = Pulling eye end A (>100ft, > 30m)
12 – Unit of Length F = Feet (OFNP)
M = Meters (LSZH)
13, 14, 15 – Cable Assembly Length
015 - 300ft 1ft increments to 100ft, 5ft increments to 300ft 005 – 100m, 1m increments
3
0
HD Flex™ Harness Assemblies
part number
Example: FZTRP8NQSONF003 = Fiber OM4, 12-ber, round, plenum rated, PanMPO male to Push/Pull duplex LC harness with 61cm equal breakout, standard IL, no pulling eye, 3 feet
15
0
CHARACTER
EXAMPLE
1
2
3
F
Z
T4R5P687N8Q9S10O11N
1 – Fiber Product
F = Fiber 2 –
Fiber Type
9 = Singlemode X = OM3 Z = OM4
3 – Fiber Count
T = 12-fiber 8 = 8-fiber
4 – Cable Type
R = Round
5 – Jacket Type
L = Low Smoke Zero Halogen (LSZH)
P = Optical Fiber Nonconductive Plenum (OFNP)
6 – Connector Type End “A” 5 = Singlemode MPO Female
6 = Singlemode MPO Male 7 = Mulitmode PanMPO™ Female 8 = Multimode PanMPO™ Male
7 – Connector Variant
N = No variant
8 – Connector Type End “B” Q = Push/Pull Duplex LC 9 – Connector Variant S = 24-inch (61 cm)
12
13014015
F
10 – Performance/Construction
S = Standard IL / Standard Fanout (Singlemode) O = Optimized IL / Standard Fanout (Multimode)
Q = Standard IL / 4-to-1 Conversion (Singlemode) 8-fiber only
V = Optimized IL / 4-to-1 Conversion (Multimode) 8-fiber only
N = Ultra Low IL/Standard Fanout (OM4 Only)
11 – Other
N = No variant
12 – Unit of Length
M = Meters F = Feet
13, 14, 15 – Length
Meters: 001 to 010, 1.5, 2.5, 3.5, 4.5 Feet: 003 to 030
3
visit www.panduit.com/hdflex
9
HD Flex™ Patch Cords
part number
Example: FX2ERQ1Q1SNM005 = Fiber, OM3, 2-ber, 1.6mm cable, riser rated, LC push-pull connector to LC push-pull connector, standard IL, 5 meters
CHARACTER
EXAMPLE
1 – Fiber Product F = Fiber 2 – Fiber Type
X = OM3 50/125µm Z = OM4 50/125µm 9 = OS1/OS2 9/125µm
3 – Fiber Count
2 = 2-fiber
4 – Cable Type
E = 1.6mm
5 – Jacket Type
L = LSZH (Low Smoke Zero Halogen) R = OFNR (Riser)
2
1
X32
F
4
E5R6Q
6 – Connector Type
Q = LC Push-Pull connector
7 – Connector Variant
1 = 1st Gen (Low Profile Duplex LC)
8 – Connector Type
Q = LC Push-Pull connector
9 – Connector Variant
1 = 1st Gen (Low Profile Duplex LC)
10 – Performance/Construction
S = Standard IL/Straight Through (A-B)
O = Optimized IL/Straight Through (A-B)
N = Ultra IL/Straight Through (A-B)
7
18Q91
10S11N12M13014
0
11 – Connector Variant
N = No variant
12 – Unit of Length
M = Meters F = Feet
13, 14, 15 – Length 001 - 050 in 1 meter increments
1/2 meter increments available between 1 and 10 meters, ex 3.5
Foot-length increments available from 1 to 25 feet in Riser-rated jacket only
15
QuickNet™ 24F MPO Trunk Assemblies
part number
Example: FZUYPE5E5XAF050 = Fiber, OM4, 24-ber, indoor trunk, plenum rated, (1) 24F MPO female to (1) 24F MPO female, HD Flex transitions and 1-meter breakout, Method A, optimized IL, with pulling eye, 50-feet
5
CHARACTER
EXAMPLE
1 – Fiber Product
F = Fiber 2 –
Fiber Type
9 = Singlemode X = OM3 Z = OM4
3 – Fiber Count
U = 24-fiber
4 – Cable Type
Y = Small diameter indoor
5 – Jacket Type
P = Plenum L = LSZH
10
visit www.panduit.com/hdflex
1
F
2
Z3U4Y5P6E
6 – Connector (End “A”) E = 24F MPO female
F = 24F MPO male
7 – Connector Variant
5 = HD Flex transition, 1m breakout
8 – Connector (End “B”) E = 24F MPO female
F = 24F MPO male
9 – Connector Variant 5 = HD Flex transition, 1m breakout
7
8
9510X11A12
5
E
13014515
F
10 – Polarity/Performance
A = Singlemode, Method A, Standard IL X = Multimode, Method A, Optimized IL
11 – Pulling Eye
A = Pulling eye N = No pulling eye
12 – Length, Unit of Measure
F = Feet (Plenum) M = Meters (LSZH)
13, 14, 15 – Assembly Length
F = 015 to 300 feet (Plenum) M = 001 to 030 meters (LSZH)
0
QuickNet™ 24F MPO Interconnect Assemblies
part number
Example: FZUYPENENXNF015 = Fiber, OM4, 24-ber, interconnect, plenum rated, (1) 24F MPO female to (1) 24F MPO female, Method A, optimized IL, 15-feet
CHARACTER
EXAMPLE
1 – Fiber Product
F = Fiber 2 –
Fiber Type
9 = Singlemode X = OM3 Z = OM4
3 – Fiber Count
U = 24-fiber
4 – Cable Type
R = Round, 3.6mm indoor
5 – Jacket Type
P = Plenum L = LSZH
1
2
F
Z3U4R5P6E
7
8
N
E9N10X11N12F
6 – Connector (End “A”) E = 24F MPO female
F = 24F MPO male
7 – Connector Variant
N = No variant
8 – Connector (End “B”) E = 24F MPO female
F = 24F MPO male
9 – Connector Variant
N = No variant
13014
1
10 – Polarity/Performance
A = Singlemode, Method A, Standard IL X = Multimode, Method A, Optimized IL Y = Multimode, Method B, Optimized IL
11 – Pulling Eye
N = No pulling eye
12 – Length, Unit of Measure
F = Feet (Plenum) M = Meters (LSZH)
13, 14, 15 – Assembly Length
F = 003 to 100 feet (Plenum) M = 001 to 030 meters (LSZH)
QuickNet™ 24F MPO to (2) 12F MPO Harness Assemblies
part number
Example: FZURPEN74XNF050 = Fiber, OM4, 24-ber, plenum rated, (1) 24F MPO female to (2) 12F MPO female assembly, 24" breakout with HD Flex transition, Method A, optimized IL, 50-feet
15
5
CHARACTER
EXAMPLE
1 – Fiber Product
F = Fiber 2 –
Fiber Type
9 = Singlemode X = OM3 Z = OM4
3 – Fiber Count
U = 24-fiber
4 – Cable Type
R = Round, 3.6mm indoor
1
2
F
Z3U4R5P6E
7
9410X11N12
N87
5 – Jacket Type
P = Plenum L = LSZH
6 – Connector (End “A”) E = 24F MPO female
F = 24F MPO male
7 – Connector Variant
N = No variant
8 – Connector (End “B”) 5 = Singlemode, (2) 12F MPO Female
7 = Multimode, (2) 12F PanMPO™
9 – Connector Variant
4 = HD Flex™ Transition, 24" breakout
Female Connector
13014515
F
10 – Polarity/Performance
A = Singlemode, Method A, Standard IL X = Multimode, Method A, Optimized IL Y = Multimode, Method B, Optimized IL
11 – Pulling Eye
N = No pulling eye
12 – Length, Unit of Measure
F = Feet (Plenum) M = Meters (LSZH)
13, 14, 15 – Assembly Length
F = 003 to 100 feet (Plenum) M = 001 to 030 meters (LSZH)
0
visit www.panduit.com/hdflex
11
Panduit Corp.
World Headquarters
Tinley Park, IL 60487
800.777.3300
www.panduit.com
© 2018 Panduit Corp. ALL RIGHTS RESERVED. Printed in the U.S.A. FBCB45-SA-ENG Replaces FBCB29 9/2018