© Panduit Corp. 2018
CT-1123 and CT-1104
CONTROLLED CYCLE FERRULE CRIMPING TOOLS
OPERATION, INSPECTION and MAINTENANCE INSTRUCTIONS
PA25121A01
EV: 03 2-2018
R
Fig. 1
CT-1123 Tool
Self-adjusting crimp die
for Insulated and noninsulated ferrules.
Ferrule size dependent on
wire gage.
Refer to ferrule packaging
for proper ferrule and wire
combinations.
Controlled cycle
mechanism prevents tool
from opening before
crimp cycle is
complete.
Manual release lever,
push forward in the event
that controlled cycle
mechanism must be
released.
CAUTION:
Verify power is “OFF” before working on
wiring with these tools.
The plastic grips are for the user’s
comfort, and are not intended
to insulate against electrical shock while
working on live electrical circuits.
CT-1123 and CT-1104 TOOLS
1. With the handles in the open position, insert the ferrule
into the crimp pocket. Make sure that the ferrule is
inserted fully into the crimp die (see Figure 2). Close
handles until dies just slightly grip ferrule.
2. Insert the stripped wire into the ferrule until the wire
stops. Refer to ferrule packaging for wire strip length.
3. Crimp the ferrule by closing the handles until the
controlled cycle mechanism releases. Upon release,
the handles will open automatically and the crimped
ferrule can be removed.
NOTE: Crimp entire uninsulated ferrule length. This may
require additional crimps.
Fig. 2
(CT-1104 Tool not shown)
E-mail:
techsupport@panduit.com
Cushioned handle grips
www.panduit.com
Page: 1 of 2
Stripped
Wire
Crimp Die
Ferrule
For Technical Support:
1-800-777-3300

© Panduit Corp. 2018
OPERATION, INSPECTION
and MAINTENANCE INSTRUCTIONS
CT-1104 & CT-1123
INSPECTION / MAINTENANCE
NEW TOOLS - BEFORE PLACING INTO SERVICE:
All Panduit crimping tools are inspected before they are shipped from the factory. All new tools should be inspected
before being used.
New tools are shipped, factory lubricated, in protective packaging. After inspection, simply clean any excess oil from the
crimping dies and place into service.
When the tool is not in use, keep the handles closed to prevent objects from becoming lodged in the crimping area. Store
the tool in a clean, dry area.
IN SERVICE TOOLS - AFTER TOOLS HAVE BEEN IN SERVICE:
It is recommended that each operator of the tool be made aware of - and responsible for following these maintenance
steps:
In-service tools should be cleaned and inspected at least ONCE A MONTH. To clean - wipe with a clean cloth.
In-service tools should be lubricated ONCE A WEEK, and after every cleaning. Lubricate all pins, pivots and bearing
surfaces with DOW CORNING®Molykote BR2 Plus.
Be sure to clean any excess oil from the crimping dies before using.
®
Molykote BR2 Plus is the Registered Trademark of DOW CORNING.
VISUAL INSPECTION
1. Visually inspect the tool for missing or loose pins; then close the tool and note the return action of the handles.
2. Inspect the crimping dies for worn, chipped or broken edges.
3. If parts are missing, defective or damaged; contact Panduit for information on repair or replacement of tools.
4. Check for debris in dies. Any debris will need to be removed prior to tool use.
Page: 2 of 2