Panduit CP-881 Operation Manual

CP-881
PA26958A01
Rev: 10 4-2018
AUTOMATIC WIRE STRIPPING AND FERRULE CRI MPING PRESS
© Panduit Corp. 2018
Original Instructions
TO REDUCE THE RISK OF INJURY, USER MUST READ INSTRUCTION MANUAL
Email:
techsupport@panduit.com
EU Website:
www.panduit.com/emea
EU Email:
emeatoolservicecenter
@panduit.com
www.panduit.com
Technical Support:
Tel: 1-800-777-3300
Panduit Europe • EMEA Service Center
Almelo, Netherlands
Tel: +31-546-580-452 • Fax: +31-546-580-441
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
Table of Contents
COMPLIANCE ................................................................................................................................. 1
TECHNICAL DATA .......................................................................................................................... 2
Name Plate ................................................................................................................ 2
PRECAUTIONS AND GENERAL GUIDELI NES .............................................................................. 2
Safety Warnings ......................................................................................................... 3
Electrical Safety Practices ............................................................................... 4
Personal Safety ............................................................................................... 5
Power Tool Use And Care ............................................................................... 6
Service............................................................................................................ 6
Dedicated Usage ........................................................................................................ 7
Dangers ......................................................................................................... 7
Places for Use ............................................................................................................ 7
Safety Devices ........................................................................................................... 7
Authorized user .......................................................................................................... 7
Contents of Delivery ................................................................................................... 8
USAGE ............................................................................................................................................ 9
Standard Components Overview .............................................................................. 10
Standard Component Functions ............................................................................... 11
SETUP ............................................................................................................................................11
OPERATION ...................................................................................................................................15
RETOOLING ...................................................................................................................................17
FAULTS ..........................................................................................................................................19
TROUBLESHOOTING ....................................................................................................................19
SPARE PARTS ...............................................................................................................................26
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 1 of 28 4-2018
COMPLIANCE
FCC Part 15, Subpart A
Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
Conforms to: ETL Intertek No. 4008921 Conforms to: ANSI / UL 987-2013, R. 05-02-2013 Cert. To: CSA C22.2 No. 73, R2009 CAN ICES-1/NMB-1
NOTE: In the interest of higher quality and value, Panduit products are continually being improved and updated. Consequently, pictures may vary from the enclosed product.
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 2 of 28 4-2018
TECHNICAL DATA
Main power supply ................................................................................. 120 VAC / 60 Hz
Input Current ........................................................................................................... 0.55A
Working range ................................................................ #20 – #14 AWG (0,5 – 2,5 mm
2
)
Ferrules ...................................................................... I n Bands acc. To DIN 46228 Part 4
Press form ............................................................................................ Trapezoid shaped
Cycle time ................................................................................................................. 1.5 s
Control system ......................................................................... Microprocessor controlled
Counter ......................................................................................................... LCD Display
Retooling ......................................................................................................... Below 10 s
Sizes (Width x Length x Height) ......................................................... 6.5 x 12.6 x 11.0 in.
.......................................................................................................... 165 x 320 x 279 mm
Weight ......................................................................................................... approx. 26 lb.
................................................................................................................... approx. 12 kg.
Name Plate
Panduit Corp.
18900 Panduit Drive, Tinle y Park, IL 60487 USA
CP-881
Serial Number Cross Section (working range) Manufactured: MM-YY Compliance
Main Connection / Input Current Conformances
Country of Origin Fuse Detail Website Addre ss
PRECAUTIONS AND GENERAL GUIDELINE S
The basic condition for safe use and proper operation of the CP-881 is the knowledge and attention to the safety
information provided in this manual.
The following safety information must be observed by all persons who will work with the CP-881 Crimping Press
.
All rules and instructions for the work place must be observed, especially those for prevention of accidents.
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 3 of 28 4-2018
This symbol is used to call your attention to hazards or unsafe practices which could result in an injury or property damage. The signal word, defined below, indicates the severity of the hazard. The message after the signal word provides information for preventing or avoiding the hazard.
WARNING
Hazards which, if not avoided, COULD result in severe injury or death.
CAUTION
Hazards or unsafe practices which, if not avoided, MAY result in injury or property damage.
Safety Warnings
WARNING
Read all safety warning and all instructions. Failure to follow the warnings
and instructions may result in electric shock, fire and/or serious injury.
• Save all warnings and instructions for future reference.
The term “power tool” in the warnings refers to your main-operated (corded) power
tool.
Panduit Corp. recommends the tool be used with all installed safety features. Customer assumes all liability for injury that could result from improper use of this tool and responsibility for all necessary training to ensure safe operation of this tool.
FOR INSTALLATION AND USE BY TRAINED PERSONNEL ONLY.
IF ANY DAMAGE TO THE PRODUCT IS APPARENT OR SUSPECTED, DO NOT USE THE
PRODUCT. REFER PRODUCT TO QUALIFIED SERVICE PERSONNEL.
FCC WARNING: CHANGES OR MODIFICATIONS TO THE PRODUCT COULD VOID THE
USER’S AUTHORITY TO OPERATE THE PRODUCT.
USE RECOMMENDED ACCESSORIES. CONSULT THE OWNER’S MANUAL FOR
RECOMMENDED ACCESSORIES. THE USE OF IMPROPER ACCESSORIES MAY CAUSE RISK OF INJURY TO PERSONS.
WARNING
DO NOT OPER ATE POWER TOOLS I N EXPLOSI VE ATM OSPHERES , SUCH AS IN TH E
PRESENCE OF FLAMMABLE LIQUIDS, GASES OR DUST.
Power tools create sparks which may ignite the dust or fumes. Provide adequate ventilation around the product.
WARNING
KEEP WORK AREA CLEAN AND WELL LIT.
Cluttered or dark areas invite accidents.
KEEP CHILDREN AND BYSTANDERS AWAY.
All visitors should be kept a safe distance fromwork area.
MAKE WORKSHOP KID PROOF with padloc ks, master switches, or by removing starter keys.
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 4 of 28 4-2018
Electrical Safety Practices
GROUNDING:
In the event of a malf unction or break down, groundin g provides a pat h of least resistance for electric current wh ich re duces the r isk of elec trical s hock . This tool is equi pped with an electric cord that inc ludes an equipm ent-grounding conduc tor and a ground ing plug. The plug must be inserted into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances.
Improper connection of the equipment groundin g conductor can result in a risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipment-grounding conductor to a live terminal.
Check with a qualified electrician, or service personnel if the grounding instructions are not completely understood; or if in doubt as to whether the tool is properly grounded.
DO NOT modify the plug provided. If it will not fit the outlet, have the proper outlet installed by a qualified electrician.
Use only 3-wire extension cords that have 3-prong grounding plugs and 3-pole receptacles that accept the tool's plug. Replace a damaged or worn cord immediately.
Avoid body contact with earthed or grounded surfaces, such as pipes, radiators, ranges and refrigerators.
There is an increased risk of electric shock if your body is earthed or grounded.
DO NOT abuse the cord. Never use the cord for carrying, pulling or unplugging the power tool. Keep cord away from heat, oil, sharp edges or moving parts. Damaged
or entangled cords increase the risk of electric shock.
WARNING
Power tool plugs must match the outlet. Never modify the plug in any way. Do not
use any adapter plugs with earthed (grounded) power tools.
Unmodified plugs and matching outlets will reduce risk of electric shock.
USE PROPER EXTENSION CORD.
Make sure your extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. Size the
cord according to table below. If in doubt, use a heavier gauge.
Volts
Total Length of Cord mm / (feet)
120
mm (25)
mm (50)
mm (100)
mm (150)
Minimum Wire
Gauge of Cord
---
mm (18)
mm (16)
mm (16)
mm (14)
WARNING
ONLY OPERATE THE CP-881 A CLEAN, DRY, INDOOR ENVIRONMENT.
DO NOT EXPOSE POWER TOOLS TO RAIN OR WET CONDITIONS.
Water entering a power tool will increase the risk of electric shock.
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 5 of 28 4-2018
KEEP AWAY FROM LIVE CIRCUITS:
Operating personnel must not remove covers.
Replacement of components and internal adjustments must be made by qualified
maintenance personnel.
Disconnect power cable when replacing components.
Dangerous voltages may exist even with the power cable removed.
To avoid injuries, always disconnect power and discharge circuits by grounding
before touching circuitry.
Input connection to the product must remain accessible as a disconnect device.
DO NOT work on the product; connect or disconnect cables during periods of
lightning.
Provide wiring per national and local electr ical codes.
Personal Safety
WARNING
Use personal protective equipment. Safety glasses must be worn at all times by all
persons operating the CP-881.
WARNING
Hearing protection is recommended to be worn during operation of tool.
1. STAY ALERT, watch what you are doing and use common sense when opera ting a power tool.
Do not use a power tool while you are tired or under the influence of drugs, alcohol or medication.
A moment of inattention while operating power tools may result in serious personal injury.
2. KEEP GUARDS IN PLACE and in working order.
These safety guards should be removed only by specialized and authorized technical persons who take care to adopt all security measures to avoid any risk of danger and injury.
3. PREVENT UNINTENTIONAL STARTING. Ensure the switch is in the off-position before
connecting to power source and/or battery pack, picking up or carrying the tool.
Carrying power tools with your finger on the switch or energizing power tools that have the switch on invites accidents.
4. NEVER LEAVE TOOL RUNNING UNATTENDED.
TURN POWER OFF. Don’t leave tool until it comes to a complete stop.
5. Remove any adjusting key or wrench before turning the power tool on.
A wrench or a key left attached to a rotating part of the power tool may result in personal injury.
6. Do not overreach. Keep proper footing and balance at all times.
This enables better control of the power tool in unexpected situations.
7. NEVER STAND ON TOOL.
Serious injury could occur if the tool is tipped or if the cutting tool is unintentionally contacted.
8. Wear proper apparel. Do not wear loose clothing, gloves, neckties, rings, bracelets, or other
jewelry which may get caught in moving parts. Nonslip footwear is recommended. Wear protective hair covering to contain long hair.
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 6 of 28 4-2018
9. If devices are provided for the connection of dust extraction and collection facilities, ensure
these are connected and properly used. Use of dust collection can reduce dust-r elat ed ha zards.
Power Tool Use And Care
1. Do not force the power tool. Use the correct power tool for your application.
The correct power tool will do the job better and safer at the rate for which it was designed.
2. Do not use the power tool if the switch does not turn it ON and OFF. Any power tool that cannot be controlled with the switch is dangerous and must be repaired.
3. Disconnect the plug from the power source and/or the ba ttery pack from the power tool before making any adjustments, changing accessories, or storing power tools. Such preventive safety measures reduce the risk of starting the power tool accidentally.
4. Store idle power tools out of the reach of chi ldren and do not allow persons unfamiliar with the power tool or these instructions to operate the power tool. Power tools are dangerous in the hands of untrained users.
5. Maintain power tools. Check for misalignment or binding of moving parts, breakage of parts
and any other condition that may affect the po wer too l’s operation. If damaged, have the power tool repaired before use.
Many accidents are caused by poorly maintained power tools.
6. Keep cutting tools sharp and clean.
Properly maintained cutting tools with sharp cutting edges are less likely to bind and are easier to control.
7. Use the power tool, accessories and tool bits, etc. in accordance with these instructions, taking into account the working conditions and the work to be performed.
Use of the power tool for operations different from those intended could result in a hazardous situation.
Service
Have your power tool serviced by a qualified repair person using only identical
replacement parts.
Contact Panduit Tool Service at the following locations:
Panduit Electrical Headquarters (USA)
16530 W. 163rd Street Lockport, IL 60441 USA
Tel.: 1-800-777-3300
Panduit EMEA Service Center (EUR)
EMEA Tool Service Center Bedrijvenpark Twente 360 7602 KL Almelo
tel + 31 546 580 451
The information contained in this manual is based on our experience to date and is believed to be reliable. It is intended as a guide for use by persons having technical skill at their own discretion and risk. We do not guarantee favorable results or assume any liability in connection with its use. Dimensions contained herein are for reference purposes only. For specific dimensional requirements consult the factory. This publication is not to be taken as a license to operate under, or a recommendation to infringe any existing patents.
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 7 of 28 4-2018
Dedicated Usage
Use the CP-881 only for automatic wire stripping and ferrule crimping.
Continuously molded ferrules with cross-sections ranging from #20 – #14 AWG (0,5 – 2,5mm
2
)
and a strip length of 5/16” (8 mm) must be used.
Only the intended PVC insulated cables may be inserted into the funnel guide of the CP-881. Never insert solid metal parts or items, the stripping knives would be damaged.
Third party reconstruction and changes of the CP-881 beyond retooling are not allowed because of safety!
Dangers
Use the CP-881 only when the cover is closed.
Before carrying out any wor k with the cover open (e.g. retooling, maintenance work), disconnect
the CP-881 from the main power supply
Make sure that no strange objects are inside the case.
Places for Use
Avoid operation in the following areas:
Damp or dusty places
Places exposed to high or low temperatures, or direct sunlight
Operating temperature range: 59°F to 95°F (15°C to 35°C)
Condensation can form when moving from a cold to a warm place
Open cover to evaporate any condensation before using the CP-881
Do not spill any liquids over the CP-881
Protect the CP-881 from heavy vibrations and jolts
Safety Devices
The CP-881 can be switched OFF through:
o The main switch (O OFF) o Pulling out the main plug o Sliding back the cover (by two micro switches) o The cover is built in for safety. It may not be changed, removed or by-passed by
reconstructions. A label points to existing dangers.
Before opening disconnect main power. Vor Öffnen des Gehäuses Netzstecker ziehen. Avant d’ouvrir l’appareil retirez la fichemâle.
Authorized user
Only authorized and instructed users are allowed to work with the CP-881
The user has a responsibility to other persons inside the CP-881 work place
The customer must:
Make the operation manual accessible to the user; and assure that the user has read and understood the manual.
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 8 of 28 4-2018
Contents of Delivery
Diagram 1: Contents of Delivery
1. CP-881 1 piece
6. Ferrule Feeder #20–#14 AWG (0,5 to 2,5mm
2
)
5 pieces
2. Main Cable 1 piece
7. Adjustable Tool Insert for #20–#14 AWG (0,5 to 2,5mm
2
)
5 pieces
3. Wire Insulation Scrap
Container
1 piece 8. Locator (spare) 5 pieces
4. Operation Manual (English) 1 piece
9. Wire Guiding Tube (spare) <not shown>
5 pieces
5. Tool Kit 1 piece 10. Bolt, 6mm in diameter w/Lanyard 1 piece
NOTE: Parts 6, 7 and 8 have the same color code as ferrules, complying with DIN.
(USA Cord supplied)
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 9 of 28 4-2018
USAGE
The CP-881 is for fully automatic stripping of flexible PVC insulated cables and subsequent pressing on of continuously molded insulated ferrules on r eels.
It uses continuously molded ferrules complying with DIN 46228 Part 4, with cross-sections ranging from #20 – #14 AWG (0,5 – 2,5mm
2
), with a stripping length of 5/16” (8mm). Due to the short cycle times (1.5 s) and simple changing of cross-sections (below 10 s), the CP-881 is not only suitable for use in workshops but also in complex cable production systems.
The following ferrules can be used by the CP-881:
Cross-section
AWG (mm
2
)
Length
In. / (mm)
DIN
Color Code
20 (0,5) 5/16” (8) White
18 (0,75) 5/16” (8) Grey
18 (1,0) 5/16” (8) Red 16 (1,5) 5/16” (8) Black 14 (2,5) 5/16” (8) Blue
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 10 of 28 4-2018
Standard Components Overview
Diagram 2: Standard Components
1. Grip 9. Main connection
2. Funnel guide 10. Main fuses
3. Counter 11. Main switch
4. Reset button 12. Transformer fuses
5. Tool insert 13. Reverse button
6. Bolt with Lanyard 14. Ferrule dispenser holder
7. Cover 15. Container
8. Ferrule feeder
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 11 of 28 4-2018
Standard Component Functions
1. Grip
For transport of the CP-881
2. Funnel Guide
The cable to be processed is inserted into the CP-881 through the funnel guide. Once it has been inserted, work commences automatically.
3. Counter (000000 to 999999)
The counter counts the number of end-sleeves used. The CP-881 performs a reset automatically to 0 at power-OFF.
4. Reset Button
This button resets the counter to 0.
5. Tool Insert (Color Coded)
Positions the ferrule and strips the cable. The appropriate tool insert must be installed for every cross-section.
6. Bolt
Secures the tool insert (attached to CP-881 by lanyard).
7. Cover
Protects the user from moving parts inside the CP-881. The CP-881 will only operate when the cover is properly closed.
8. Ferrule Feeder
The ferrule feeder positions the ferrules. The appropriate ferrule feeder must be installed for every cross-section.
9. Main Connection
The main cable must be connected to the input connector.
10. Main Fuses
Two 1.25A/T/250 V fine wire fuses integrated into the main connection.
11. Main Switch
Switches the power supply to the CP-881 ON (Position I) or OFF (Position O).
12. Transfor mer Fuses
One 4.0 A/T/250 V fine wire fuse for secondary device.
13. Reverse Button
Pressing this button puts the CP-881 in the maintenance position. Pressing again will put the CP-881 in start position.
14. Ferrule Dispenser Holder
Holds the ferrule reel dispenser.
15. Container
The container collects the insulation scrap. It must be emptied regularly.
SETUP
1. Choose the installation site
o The installation site of the CP-881 must be level and horizontal.
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 12 of 28 4-2018
NOTE: Observe the working conditions in Safety section, Places for Use on Page 7
2. Prepare the dispenser o Open the dispenser and tear-off the
strap at the edge (1).
o Pull out the ferrule band (2)
approximately 8” (20 cm).
Diagram 3: Prepare the dispenser
3. Prepare the ferrule feeder o Take ferrule feeder with proper
cross-section from the tool kit. NOTE: Observe the color code of
the ferrule feeder
o Insert the ferrules (1) in the guide
sideways until the stop pin is reached.
o Pull the pin (2) upwards, move the
ferrules to the mark (3) and let the pin go.
NOTE: Check that the pin has clicked properly into place.
Diagram 4: Prepare the ferrule feeder
4. Fit the ferrule feeder
NOTE: Verify that the tool insert is not installed yet.
o Slide the cover (1) back. o Insert the ferrule feeder (2) sideways
and place it on the bolts (3). NOTE: Check that the ferrule feeder
has clicked properly into place.
Diagram 5: Fit the ferrule feeder
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 13 of 28 4-2018
5. Mount the dispenser o Mount the dispenser (1) on the
holder. NOTE: Check that the dispenser has
clicked properly into place.
Diagram 6: Mount the dispenser
6. Mount the adjustable tool insert o Take the tool insert with proper
cross-section from the tool kit. Adjustment screw should be all the way counter-clockwise for standard operation.
NOTE: Observe the color code of the tool insert.
o Mount the tool insert (1) sideways. o Fit the bolt (2) into the hole until it
stops.
Diagram 7: Mount the adjustable tool insert
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 14 of 28 4-2018
7. Place into operation mode o Put the dispenser (1) in operation
mode.
o Close the cover (2).
NOTE: Be sure that the ferrule band is fed properly.
o Connect the main cable with the
appropriate connectors (3, 4) to the CP-881 and the main power supply.
The CP-881 is now ready for operation.
Diagram 8: Place into operation mode
(USA Cord supplied)
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 15 of 28 4-2018
OPERATION
1. Prepare the cable o Before crimping, cable must
be aligned as straight as possible.
Diagram 9:
Prepare the cable
Bend OK
Max. 0.08” – 0.10”
(2-3mm)
over a length of
2.5” (60mm)
Bend too large
2. Cut the cable o Cut the cable clean and
straight. NOTE: Poor cut (Diagram 11)
frequently results in unsuccessful crimping.
Diagram 10:
Cutting the cable
Good cut
Diagram 11: Poor cut
Surface inclined
Squashed cut, individual wires protrude
Squashed cut
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 16 of 28 4-2018
3. Start the CP-881 o Check that the cover (1) is
closed.
o Turn on (Position I) the
CP-881 with the main switch (2).
o Check that counter (3) is at 0.
NOTE: If the counter is not a 0, refer to chapter Faults.
Diagram 12: Start the CP-881
4. Crimping cables o Insert the cable (1) straight
into the funnel guide until it stops.
o Crimping and stripping works
automatically.
o Pull out the cable (2) straight
when the CP-881 has stopped.
NOTE: Refer to chapter faults when operating faults or unsuccessful crimping occurs.
o Read counter (3) if required
and set it to 0 with the reset button (4).
Diagram 13: Crimping cables
5. Stop operation
o Read counter (1) if required. o Turn OFF (Position O) the
main switch (2) to the CP-881.
Diagram 14: Stop operation
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 17 of 28 4-2018
6. Daily maintenance
Disconnect the main power supply from the CP-881 and open cover.
o Turn OFF (Position O) the
main switch (1) to CP-881.
o Disconnect main cable (2). o Slide the cover (3) back. o Remove (4) insulation scraps
inside the CP-881.
o Pull out the container (5). o Dispose of insulation scraps
and insert container.
o Close the cover (6). o Connect main cable (7). o NO LUBRICATION
REQUIRED!
Diagram 15: Daily maintenance
RETOOLING
1. Prepare the retooling Disconnect the main
power supply from the CP-881 and open cover.
o Read counter if required. o Turn OFF the CP-881 with
main switch (1).
o Disconnect main cable (2). o Slide back the cover (3). o Pull the pin (4) upwards and
pull out the ferrules (5).
o Remove the dispenser (6)
and roll up the remaining ferrules.
o Fold back the dispenser
holder (7).
Diagram 16: Prepare the retooling
(USA Cord supplied)
(USA Cord supplied)
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 18 of 28 4-2018
2. Remove the tool insert
o Pull out the bolt (1). o The tool insert (2) must be
removed sideways.
o Put the tool insert into the
tool kit.
o Check crimp die for talcum
powder build-up. If powder build-up, clean
with brush.
Diagram 17: Remove tool insert
3. Remove the ferrule feeder o Pull the ferrule feeder (1)
towards the rear and remove it sideways (2).
o Put the ferrule feeder into the
tool kit.
Continue as described with Step 2 to 7 in Chapter
SETUP.
Diagram 18: Remove the ferrule feeder
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 19 of 28 4-2018
FAULTS
When operating faults occur, trouble-shooting depends on different fault conditions. After recognizing the fault condition, trouble-shooting can be carried out by the following points.
Fault Condition 1
Cable cannot be inserted.
Fault Condition 2
Crimping has not been completed.
Fault Condition 3
Crimping is completed. Cable cannot be pulled out.
Fault Condition 4
Cable insulation is not completely removed.
Fault Condition 5
The ferrule is not separated from band.
Fault Condition 6
Counter related fault, CP-881 does not work.
Fault Condition 7
The CP-881 works tool slow, but counter works.
Fault Condition 8
Crimp stamp or crimp forging die is defective.
TROUBLESHOOTING
Fault Condition 1:
Cable cannot be inserted
o Cable can only be inserted
in start position (front) and not in maintenance position (rear).
o Press the reverse button
(1) to move the CP-881 into start position.
Diagram 19: Move the CP-881 into start position
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 20 of 28 4-2018
Fault Condition 2:
Crimping has not been completed.
Disconnect the main
power
supply from the CP-881 and open cover.
1. Stop operation
o Read counter (1) if
required.
o Turn OFF (Position O) the
CP-881 with main switch (2).
o
Disconnect main cable (3).
Diagram 20: Stop operation
2. Remove the tool insert
o Slide back the cover (1). o Pull out the bolt (2). o Press lower stripping cutter
(3) upwards and remove the tool insert (4) sideways.
o Remove ferrule (5). o Bend cable aside (6).
Diagram 21: Remove the tool insert
3. Remove the cable
o Pull the pin (1) upwards
and pull out the ferrules (2).
o Close the cover (3). o Connect main cable (4). o Turn ON (Position I) the
CP-881 with the main switch (5).
o Press the reverse button
(6) to move the CP-881 into start position.
o Pull out the cable (7).
After mounting the tool insert and insertion of the ferrules, the CP-
881 is ready for operation.
Diagram 22: Remove the cable
(USA Cord supplied)
(USA Cord supplied)
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 21 of 28 4-2018
Fault Condition 3:
Crimping is completed. Cable cannot be pulled out
Disconnect the main
Power supply from the CP-881 and open cover.
1. Stop operation
o Read counter (1) if
required.
o Press the reverse button
(2) to move the CP-881 into start position.
o Turn OFF (Position O)
the CP-881 with Main Switch (3).
o Disconnect main cable (4).
Diagram 23: Stop operation
2. Remove the tool insert
o Slide back the cover (1). o Pull out the bolt (2). o Press lower stripping cutter
(3) upwards and remove the tool insert (4) sideways.
If it is impossible to
remove the tool insert, then carry out Step 4; otherwise, carry on with Step 3.
o Remove ferrule (5). o Bend cable aside (6).
Diagram 24: Remove the tool insert
(USA Cord supplied)
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 22 of 28 4-2018
3. Remove the cable
o Pull the pin (1) upwards
and pull out the ferrules (2).
o Close the cover (3). o Connect main cable (4). o Turn ON (Position I) the
CP-881 with the main switch (5).
o Press the reverse button
(6) to move the CP-881 into start position.
o Pull out the cable (7).
After mounting the tool insert and insertion of the ferrules, the
CP-881 is ready for operation.
Diagram 25: Remove the cable
4. Remove the cable
o Press the reverse button
(2) and pull the cable (1) at the same time, the CP-881 moves into start position.
o Pull out the cable (3). o Remove the tool insert (4). o Remove ferrule (5).
After mounting the tool insert, the CP-881 is ready for operation.
Diagram 26: Remove the cable
Fault Condition 4:
Cable insulation is not completely removed.
Disconnect the main power supply from the CP-881 and open cover.
1. Check the cross-section information
If stripping is faulty, check whether the selected cable cross-section corresponds to the cross­section size of the tool insert and the ferrule feeder block. The tool inserts must be adapted to the cable cross-section if the CP-881 has not been properly tooled. The cross-section of the cable must also be checked.
(USA Cord supplied)
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 23 of 28 4-2018
2. Check the stripping cutter
After checking the cross-section size remove the tool insert (see Chapter
RETOOLING) and check
the stripping cutters (1).
Replace the stripping cutters of the tool insert if they are worn or damaged.
Remove the allen screw (2) at the bottom and insert new stripping cutters with the same cross­section. The corresponding article number is stated in Chapter
SPARE PARTS.
3. Adjustable Cutting Blades
The tooling insert has adjustable
cutting blades.
Using a small Phillips screwdriver,
the blade can be adjusted to cut slightly deeper by turning the screw clockwise.
Turn the screw, in small
increments to prevent cutting or nicking the wire during insulation stripping.
Diagram 27: Check the stripping cutter
Fault Condition 5:
The ferrule is not separated from band.
Open the cover and disconnect the CP-881 from main power supply.
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 24 of 28 4-2018
If the cutter (1) is damaged or broken off, the cable crimped with the ferrule will not be separated from the band.
In this case, remove the tool insert (see also Chapter
RETOOLING)
and check the cutter (1). When the cutter (1) is defective, the ferrule locator (3) must be removed by unscrewing the cross­head screw (2) and a new locator for the corresponding cross section must be fitted.
The corresponding article number is stated in Chapter
SPARE
PARTS
.
Diagram 28: Check the cutter
Fault Condition 6:
Counter respectively CP-881 does not work.
1. Check main connection
Check that the main cable is connected correctly to the CP-881 and the main power
supply. Make sure that you have proper power supplied to the plug socket.
2. Check main fuses
Main connection must be
opened, disconnect the CP-881 from main power.
o Pull out main plug (1). o Pull out the fuse holder (2). o Check the main fuses (3). o Replace defective main
fuses (MC2SI1.25). The corresponding article number is stated in Chapter
SPARE PARTS.
o Put the main fuses into
fuse holder.
o Insert the fuse holder.
Fuse holder must click
into place.
Diagram 29: Check main fuses
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 25 of 28 4-2018
Fault Condition 7:
The CP-881 works too slow but counter works.
Remove main fuses, disconnect the CP-881 from main power.
o Pull out main plug (1). o Unscrew the fuse holder
(2).
o Check the device fuses
(3).
o Replace defective device
fuses (MC2SI4.0). The corresponding article number is stated in Chapter
SPARE PARTS.
o Insert device fuses into the
fuse holder.
o Insert the fuse holder.
Diagram 30: Check device fuses
Fault Condition 8:
Crimp stamp or crimp forging die is defective.
Open the cover and disconnect the CP-881 from main power.
o Pull out main plug (1). o Remove tool insert and
ferrule feeder (see Chapter
RETOOLING).
o Unscrew the allen screw
(3) at defective crimp stamp (2) or crimp forging die (1).
o Press the ring (4) down
and remove the hose.
o Replace the defective part.
The corresponding article number is stated in Chapter
SPARE PARTS.
Plastic parts must be
clean and free of grease.
Diagram 31: Replace crimp stamp /
crimp forging die
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 26 of 28 4-2018
SPARE PARTS
Part
Cross Section
AWG (mm2)
Part No. Packing Unit
Tool Insert
20 (0,5) MC2SCH05 1 piece
18 (0,75) MC2SCH07 1 piece
18 (1,0) MC2SCH10 1 piece
16 (1,5) MC2SCH15 1 piece
14 (2,5) MC2SCH25 1 piece
Stripping Cutter
20 (0,5) MC2AM05 1 piece
18 (0,75) MC2AM07 1 piece
18 (1,0) MC2AM10 1 piece
16 (1,5) MC2AM15 1 piece
14 (2,5) MC2AM25 1 piece
Adjustable
Stripping Cutter
20 (0,5) MC2AM05E 1 piece
18 (0,75) MC2AM07E 1 piece
18 (1,0) MC2AM10E 1 piece
16 (1,5) MC2AM15E 1 piece
14 (2,5) MC2AM25E 1 piece
Locator
20 (0,5) MC2LOC05 3 pieces
18 (0,75) MC2LOC07 3 pieces
18 (1,0) MC2LOC10 3 pieces
16 (1,5) MC2LOC15 3 pieces
14 (2,5) MC2LOC25 3 pieces
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 27 of 28 4-2018
Part
Cross Section
AWG (mm2)
Part No. Packing Unit
Ferrule Feeder
20 (0,5) MC2MAG05 1 piece
18 (0,75) MC2MAG07 1 piece
18 (1,0) MC2MAG10 1 piece
16 (1,5) MC2MAG15 1 piece
14 (2,5) MC2MAG25 1 piece
Wire Guiding Tube
20 (0,5) MC2 0071 2 pieces
18 (0,75) MC2 0072 2 pieces
18 (1,0) MC2 0073 2 pieces
16 (1,5) MC2 0074 2 pieces
14 (2,5) MC2 0075 2 pieces
Bolt
----- MC2BOL 1 piece
Main Fuse
1.25 A / T/250 V
----- MC2SI1.25 2 pieces
Device Fuse
4,0 A / T/250 V
----- MC2SI4.0 2 pieces
© Panduit Corp. 2018
OPERATION MANUAL CP-881 ENG
PA26958A01_10 ENG Page: 28 of 28 4-2018
Part
Cross Section
AWG (mm2)
Part No. Packing Unit
Crimp Die
----- MC2CGES 1 piece
Crimp Stamp
----- MC2CSTE 1 pi ece
Centering Fork Bottom
----- MC2 0011 1 piece
Centering Fork Top
With Tube
----- MC2 0013 1 piece
Centering Fork Top
Without Tube
----- MC2 0013K 1 piece
Loading...