Mini-Com Cable Strain Relief Module
CMCSR**
Twist cap
ITEMS REQUIRED FOR ASSEMBLY
1. Jacket Stripper (available from Panduit)
2. Diagonal Cutters (not available from Panduit)
3. Fiber optic cable with 0.19" (4.8mm) to 0.31" (7.9mm) dia,
round outer jacket and aramid yarn.
Module
Aramid yarn
Fiber
Outer Jacket
Feed fiber through hole in front of module and twist cap.
Strip outer jacket to provide desired fiber length behind module.
Do not damage or cut the inner fiber jackets or aramid yarn. Cut
the aramid yarn a minimum length of 0.50" (12.7mm).
3.
1.
2.
Align the end of the cable outer jacket to the end of the module
threads. NOTE: THIS IS A CRITICAL STEP TO ENSURE THE
CABLE IS SECURED TIGHTLY (WITH NO SLACK) TO THE
MODULE.
4.
Flare aramid yarn evenly around the threads of the module.
Part Number: CMCSR**
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
READ ALL INSTRUCTIONS COMPLETELY BEFORE PROCEEDING
COMPONENT IDENTIFICATION
FS058
Product Operating Temperature: 0° - 75°C (32° - 167°F)
** Denotes color
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 1 of 2

© Panduit Corp. 2014
5.
With the aramid yarn between the module threads and twist cap,
hand-tighten the twist cap onto the threads of the module using a
clockwise motion.
6.
Insert the module(s) into the surface mount box. Align the cutout in
the front of the module with the notch on the surface mount box as
shown. Push on the rear of the module to snap it into place.
INSTALLATION INSTRUCTIONS
FS058
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
www.panduit.com
Page 2 of 2
E-mail:
techsupport@panduit.com
Phone:
866-405-6654