GIGA-TX Shielded Jack Modules
Part Numbers: CJS588T, CJS5E88T
© Panduit Corp. 2004
FTP / ScTP
Conductors
S-FTP
Conductors
Overall Foil
Screen
Drain wire
Overall Foil
Screen
INSTALLATION INSTRUCTIONS PN347
CABLE PREPARATION
Drain wire
2.0 in
(50.8 mm)
Drain wire
2.0 in
(50.8 mm)
Braid
.5 in
(12.7 mm)
STP / PIMF
Individual Foil
Pair Screen
Conductors
2.0 in
(50.8 mm)
Braid
.5 in
(12.7 mm)
Note: May also use S-STP / PIMF cable type (conductors, individual foil pair screen, overall foil screen, and braid).
TERMINATION
1
1234
T568A
1.
GREEN
WHITE/GREEN
2.
ORANGE
WHITE/ORANGE
3.
BLUE
WHITE/BLUE
4.
BROWN
WHITE/BROWN
T568B
1.
ORANGE
WHITE/ORANGE
2.
GREEN
WHITE/GREEN
3.
BLUE
WHITE/BLUE
4.
BROWN
WHITE/BROWN
2
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 1 of 3

INSTALLATION INSTRUCTIONS PN347
3
4
3 1
5
10
T568A
1.
2
BROWN
2.
WHITE/BROWN
3.
WHITE/GREEN
4.
GREEN
T568B
1.
BROWN
2.
WHITE/BROWN
3.
WHITE/ORANGE
4.
ORANGE
4
T568A
8
5
5.
ORANGE
6.
WHITE/ORANGE
7.
WHITE/BLUE
7
8.
BLUE
T568B
5.
GREEN
6.
WHITE/GREEN
7.
WHITE/BLUE
8.
BLUE
6
T568A
9.
ORANGE
10.
WHITE/BLUE
T568B
9.
GREEN
10.
WHITE/BLUE
6
CWST
9
7
8
CGJT
SHIELD INSTALLATION
1 2 3 4
(OR)
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 2 of 3

TELECOMMUNICATION ROOM SHIELDING CONTINUITY
FTP / ScTP
Drain wire
S-FTP, STP / PIMF,
S-STP / PIMF
INSTALLATION INSTRUCTIONS PN347
2
1
3
2
All Metal Patch
Panel Shielding
(OR)
CJSGK-X Kit
All Metal Patch
Panel Shielding
TERMINATION CAP REMOVAL
1 2
G
IGA-TX Wiring Sequences
Pin #’s
18
T568-A
Brown
White/Brown
Orange
White/Blue
White/Orange
Blue
Green
White/Green
BOTTOM
8
7
6
5
4
3
2
1
7 8
4 6
5 3
2 1
TOP
White/Brown
White/Green
White/Orange
T568-B
Brown
Green
White/Blue
Blue
Orange
1
(OR)
CJSGK-X Kit
3
3
Notes:
1. For specified performance, follow TIA/EIA 568-B installation guidelines.
2. Jack Modules can terminate PVC or Plenum rated 22-24 AWG solid or
stranded IWC cable with 0.048 inch (1.2 mm) maximum insulated
conductor outside diameter.
3. Jack Modules may be re-terminated a minimum of 10 times.
4. For technical and performance information, consult PANDUIT Technical
Support.
TOP
8
7
6
5
4
3
2
1
BOTTOM
7 8
4 6
5 3
2 1
As with all Wiring Accessories, the following statements apply:
1. Never install communications wiring during a lightning storm.
2. Never install communications wiring in wet locations unless the jack is
specifically designed for use in wet locations.
3. Never touch uninsulated communications wiring or terminals unless the
communication line has been disconnected at the network interface.
4. Use caution when installing or modifying communication wiring.
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
www.panduit.com