Panduit CJS588 Installation Instructions Manual

Page 1
Individual foil
Conductors
STP / PIMF
pair screen
0.5 in
(12.7 mm)
3.0 in
(76.2 mm)
Mini-Com Mini-Jack Shielded Jack Module
3.0 in
(76.2 mm)
0.60 in
(15.2 mm)
Drain wire
Drain wire
Overall foil
Conductors
Drain wire
FTP / ScTP
screen
with
drain wire
without
drain wire
Conductors
Braid
S-FTP
Overall foil screen
0.5 in
(12.7 mm)
3.0 in
(76.2 mm)
Remove all but one twist per pair, smooth conductors and arrange in proper color sequence.
1
2 1 3 5 4 6 8 7
GREEN WHITE/GREEN WHITE/ORANGE WHITE/BLUE BLUE ORANGE BROWN WHITE/BROWN
R3 T3 T2 T1 R1 R2 R4 T4
2 1 3 5 4 6 8 7
ORANGE WHITE/ORANGE WHITE/GREEN WHITE/BLUE BLUE GREEN BROWN WHITE/BROWN
R2 T2 T3 T1 R1 R3 R4 T4
Mini-Com Mini-Jack Color-Coded Wire Positions
T568A T568B
7
8
6
45
3
1
2
Part Number: CJS588
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
CABLE PREPARATION
PN348A
Note: May also use S-STP / PIMF cable type (conductors, individual foil pair screen, overall foil screen, and braid).
For Technical Support: www.panduit.com/resources/install_maintain.asp
TERMINATION
Page 1 of 3
Page 2
© Panduit Corp. 2014
2
CWST snipping tool
3
4
5
CWST
6
CJT Snap tool
7
(OR)
1
2
3
Drain wire
4
5
Drain wire
6
Crimp
RG59 coax crimp tool recommended for crimping shield ring.
ring
All Metal patch panel shielding
INSTALLATION INSTRUCTIONS
PN348A
For Technical Support: www.panduit.com/resources/install_maintain.asp
SHIELD INSTALLATION
For FTP / ScTP with drain wire
Page 2 of 3
Page 3
© Panduit Corp. 2014
1
2
1
Foil or braid
2
3
456
RG59 coax crimp tool recommended for crimping shield ring.
Crimp ring
All metal patch panel shielding
1 2 3 4 5 6
2 1 3 5 4 6
7
8
8
7
18
INSTALLATION INSTRUCTIONS
SHIELD INSTALLATION
For FTP / ScTP without drain wire, S-FTP, STP / PIMF, S-STP / PIMF
PN348A
WIRING DIAGRAM
Part Number - CJS588
Modular Plug
Contacts
Notes:
1. For specified performance, follow TIA/EIA 568-B installation guidelines.
2. Jack modules can terminate PVC or Plenum rated 22-24 AWG solid or stranded IWC cable with 0.048 in. (1.2 mm) maximum insulated conductor outside diameter.
3. Jack modules may be re-terminated a minimum of 10 times.
4. For technical and performance information, consult Panduit Technical Support.
As with all Wiring Accessories, the following statements apply:
1. Never install communications wiring during a lightning storm.
2. Never install communications wiring in wet locations unless the jack is specifically designed for use in wet locations.
3. Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface.
4. Use caution when installing or modifying communication wiring.
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
Insulation
Displacement
Contacts
TERMINATION CAP REMOVAL
Pin #’s
“A” wire
GREEN
2
BLACK
1
RED
3
WHITE
5
BLUE
4
ORANGE
6
BROWN
8
YELLOW
7
www.panduit.com
Page 3 of 3
IEC 60708-1
R3 T3 T2 T1 R1 R2 R4 T4
“B” wire
2
ORANGE
1
RED
3
BLACK
5
WHITE
4
BLUE
6
GREEN
8
BROWN
7
YELLOW