Individual foil
Conductors
Braid
STP / PIMF
pair screen
0.5 in
(12.7 mm)
3.0 in
(76.2 mm)
Mini-Com Mini-Jack Shielded Jack Module
3.0 in
(76.2 mm)
0.60 in
(15.2 mm)
Overall foil
Conductors
Drain wire
FTP / ScTP
screen
with
drain wire
without
drain wire
Conductors
Braid
S-FTP
Overall foil
screen
0.5 in
(12.7 mm)
3.0 in
(76.2 mm)
Remove all but one twist per pair, smooth conductors and arrange
in proper color sequence.
1
2
1
3
5
4
6
8
7
GREEN
WHITE/GREEN
WHITE/ORANGE
WHITE/BLUE
BLUE
ORANGE
BROWN
WHITE/BROWN
R3
T3
T2
T1
R1
R2
R4
T4
2
1
3
5
4
6
8
7
ORANGE
WHITE/ORANGE
WHITE/GREEN
WHITE/BLUE
BLUE
GREEN
BROWN
WHITE/BROWN
R2
T2
T3
T1
R1
R3
R4
T4
Mini-Com Mini-Jack Color-Coded Wire Positions
T568A T568B
7
8
6
45
3
1
2
Part Number: CJS588
© Panduit Corp. 2014
INSTALLATION INSTRUCTIONS
CABLE PREPARATION
PN348A
Note: May also use S-STP / PIMF cable type (conductors, individual foil pair screen, overall foil screen, and braid).
For Technical Support: www.panduit.com/resources/install_maintain.asp
TERMINATION
Page 1 of 3

© Panduit Corp. 2014
6
Crimp
RG59 coax crimp tool recommended
for crimping shield ring.
ring
All Metal patch
panel shielding
INSTALLATION INSTRUCTIONS
PN348A
For Technical Support: www.panduit.com/resources/install_maintain.asp
SHIELD INSTALLATION
For FTP / ScTP with drain wire
Page 2 of 3

© Panduit Corp. 2014
RG59 coax crimp tool recommended
for crimping shield ring.
Crimp
ring
All metal patch
panel shielding
1
2
3
4
5
6
2
1
3
5
4
6
7
8
8
7
INSTALLATION INSTRUCTIONS
SHIELD INSTALLATION
For FTP / ScTP without drain wire,
S-FTP, STP / PIMF, S-STP / PIMF
PN348A
WIRING DIAGRAM
Part Number - CJS588
Modular Plug
Contacts
Notes:
1. For specified performance, follow TIA/EIA 568-B installation guidelines.
2. Jack modules can terminate PVC or Plenum rated 22-24 AWG solid or stranded IWC cable with 0.048 in. (1.2 mm) maximum insulated
conductor outside diameter.
3. Jack modules may be re-terminated a minimum of 10 times.
4. For technical and performance information, consult Panduit Technical Support.
As with all Wiring Accessories, the following statements apply:
1. Never install communications wiring during a lightning storm.
2. Never install communications wiring in wet locations unless the jack is specifically designed for use in wet locations.
3. Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface.
4. Use caution when installing or modifying communication wiring.
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
Insulation
Displacement
Contacts
TERMINATION CAP REMOVAL
Pin #’s
“A” wire
GREEN
2
BLACK
1
RED
3
WHITE
5
BLUE
4
ORANGE
6
BROWN
8
YELLOW
7
www.panduit.com
Page 3 of 3
IEC 60708-1
R3
T3
T2
T1
R1
R2
R4
T4
“B” wire
2
ORANGE
1
RED
3
BLACK
5
WHITE
4
BLUE
6
GREEN
8
BROWN
7
YELLOW