TX6A 10Gig UTP Jack Modules
Jack
Wire cap
Strain relief
collar
1
CJAST
NOTE: Use setting 9 of CJAST tool.
Tur n 2 t i m e s
to cut through the
outer jacket and MaTriX tape only.
10
Do not pre-arrange
conductors.
(OR)
Part Numbers: CJ6X88TG**, CJK6X88TG**, CJQ6X88TG**, CJH6X88TG**
© Panduit Corp. 2016
INSTALLATION INSTRUCTIONS
PN511F
** Denotes color.
For Technical Support: www.panduit.com/resources/install_maintain.asp
Page 1 of 2

© Panduit Corp. 2015
12
T568B Wiring
(OR)
1.
1. 2.
R
F
R
F
T568A Wiring
12
(OR)
1.
1.
R
F
R
F
2.
2.
© Panduit Corp. 2016
INSTALLATION INSTRUCTIONS
PN511FINSTALLATION INSTRUCTIONS
Notes:
1. For specified performance, follow TIA/EIA 568-C installation guidelines.
2. Jack modules can terminate 22-26 AWG solid or stranded IWC data cable with 0.062" (1.57mm) maximum insulated conductor outside diameter.
3. Jack modules may be re-terminated a minimum of 20 times.
4. For technical and performance information, consult Panduit technical support.
As with all Wiring Accessories, the following statements apply:
1. Never install communications wiring during a lightning storm.
2. Never install communications wiring in wet locations unless the jack is specifically designed for use in wet locations.
3. Never touch uninsulated communications wiring or terminals unless the communication line has been disconnected at the network interface.
4. Use caution when installing or modifying communication wiring.
For Instructions in Local Languages
and Technical Support:
www.panduit.com/resources/install_maintain.asp
REMOVAL STEPS
www.panduit.com
Page 2 of 2
E-mail:
techsupport@panduit.com
Phone:
866-405-6654

Cable Prep for non-MaTriX Category 6A Cable
Continue with steps 8-15 on pages
1 and 2 to complete termination.