Panduit CD-920-F93 Installation Manual

Page: 1 of 2
CD-920-FXX
© Panduit Corp. 2017
INSTALLATION INSTRUCTIONS
ENGLISH
DIE INSTALLATION
DEUTSCH
INSTALLATION DES CRIMPSTEMPELS
FRANÇAISE
INSTALLATION DU POINÇON
ITALIANA
INSTALLAZIONE DADI
ESPAÑOL
INSTALACIÓN DE LOS DADOS
ÈESKÝ
VLOŽENÍ MATRICE
NEDERLANDSE
INSTALLEREN VAN DE MATRIJS
DANSKE
INSTALLATION AF MATRICE
SVENSKA
FORMINSTALLATION
SUOMEN
KAAPELIKENGÄN ASENTAMINEN
NORSK
PRESS-STEMPEL-INSTALLASJON
Page: 2 of 2
© Panduit Corp. 2017
INSTALLATION INSTRUCTIONS
CD-920-FXX
For 1 AWG using F87-18 (18mm length) ferrules, the ferrule must be double crimped as shown below to achieve a UL Listed/CSA Certified termination.
CRIMP POCKET GO/NO GO GAGE DIMENSIONS
Die P/N
GO Dia. [in.]
NO GO Dia. [in.]
CD-920-F87
0.237
0.257
CD-920-F89
0.366
0.386
CD-920-F90
0.440
0.460
CD-920-F91
0.497
0.517
CD-920-F92
0.543
0.563
CD-920-F93
0.663
0.683
CD-920-F94
0.707
0.727
Email:
techsupport@panduit.com
EU Website:
www.panduit.com/emea
EU Email:
emeatoolservicecenter
@panduit.com
www.panduit.com
Technical Support
Tel: 1-800-777-3300
Panduit Europe • EMEA Service Center
Almelo, Netherlands
Tel: +31 546 580 452 • Fax: +31 546 580 441
(All dimensions in
inches)
FOR SINGLE CRIMP: Crimp ferrule using a standard crimping action – Ferrule funnel against die set, cable insulation against funnel. (Note: Insulation pulled back only to show detail as shown above.)