PanelMax™ Space Optimization and Noise Mitigation Products
Type DRD,
DIN Rail Wiring Duct*
These wiring duct types are sold base and cover separately: G, F, D, FS, HN, H, HS, NE, CWD, and Shielded.
These wiring duct types are sold base and cover together: DRD, NNC, TNC, and MC.
*DIN Rail not included.
Type CWD,
Corner Wiring Duct
(use 2" Type C Cover)
Shielded Wiring DuctEMI Noise Shield
Type TNC Covers for
Type TNC Wiring Duct
2
Wiring Duct Available Colors and Sizes
Duct Size W x H
.5 x .512 x 12G F FSFLG F FSNE
.5 x 1G F FSG FNE
.5 x 2GG
.75 x .75G F FSG F
.75 x 1GG
.75 x 1.5G FG F
.75 x 2GGG
1 x 125 x 25G F FSNNC FLG F FSNENNCG F FSG F MC
1 x 1.525 x 37G F FSNNCTNCG FNENNCG FG F MC
1 x 225 x 50G F FS DNNCG FNENNC MCG FDG F MC
1 x 2.525 x 62MCMC
1 x 325 x 75G F FS DNNCTNCG FD NENNC MCG FDG F MC
1 x 425 x 100G F FS DG FD NEG FDG F
1.5 x 1G F FSG F FS
1.5 x 1.537 x 37G F FSNNCTNCG F FSNENNC MCG F FSG F MC
1.5 x 237 x 50G F FS D H HN HS NNCG FNE H HN HS NNC MCG FD H HS G F MC
1.5 x 2.537 x 62MCMC
1.5 x 337 x 75G F FS D H HN HS NNCTNCG FD NE H HN HS NNC MCG FD H HS G F MC
1.5 x 4G FDG FD NEG FDG F
2 x 1G F FSG F FSNEG F
2 x 1.5G F FSG F FS
2 x 250 x 50G F FS D H HN HS NNC FL TNCG F FS D NE H HN HS NNC MCG F FS D H HS G F MC
2 x 350 x 75G F FS D H HN HS NNCG F FS D NE H HN HS NNC MCG FD H HS G F MC
2 x 450 x 100G F FS D H HN HS NNCG FD NE H HN HS NNC MCG FD H HS G F MC
2 x 5G FG FG
2.5 x 2.562 x 62MCMC
2.5 x 3G FDG FG
3 x 1G F FSG F FSNE
3 x 275 x 50G F FS DG F FSNEMCG F FSGMC
3 x 2.575 x 62MCMC
3 x 375 x 75G F FS D H HN HS NNC
3 x 475 x 100G F FS D H HN HSG F FS D NE H HN HSMCG FD H HS G F MC
3 x 5G F FSG F FSNEG FG
4 x 1.5GFSG
4 x 2100 x 50G F FS DNNCTNCG F FSNENNC MCG FDGMC
4 x 3100 x 75G F FS DNNCTNCG F FSNENNC MCG FG F MC
4 x 4100 x 100G F FS D H HN HS NNCG F FS D NE H HN HS NNC MCG F FS D H HS G F MC
4 x 5G F FSG FNEG FG
6 x 4G F FSG F FS
3.35 x 2.54*85.0 x 64.4CWDCWD
4.40 x 3.57*111.8 x 90.7CWDCWD
5.33 x 4.58* 135.3 x 115.7CWDCWD
6.25 x 2.12** 156.7 x 54.0DRDDRD
7.25 x 3.12** 184.1 x 79.4DRDDRD
8.25 x 4.12** 209.5 x 104.8DRDDRD
*Corner Duct Prole
**DIN Rail Duct Prole
LG
Light Gray
WH
White
TNCG F FS D NE H HN HS NNC MCG F FS D H HS G F MC
BL
Black
IB
Intrs.
Blue
IG
Intl.
+
GrayIn.mm
+
Intrinsic Blue Color –
Intrinsic Blue wiring duct is made from the same lead-free PVC material as our standard PVC duct. Intrinsic Blue is an Internationally
recognized standard blue color that identies the wiring duct as “incapable of releasing sufcient electrical or thermal energy under normal or
abnormal conditions, to cause ignition of a specic hazardous atmospheric mixture in its most easily ignited concentrations."
+
ISA-RD12.6 (Instrument Society of America)
3
Panduct® Type D, G, F and FS Wiring Duct – Wire Fill Capacity
8
Nominal Duct
Size
(W x H)
In.
0.50 x 0.500.2503587611981511102014121912310
0.50 x 1.000.5006101614122318163123204028253924720
0.50 x 2.001.000122133282446373262464180575079591540
0.75 x 0.750.5636111916132620183426234532284425823
0.75 x 1.000.75091525211834272446343060423859361130
0.75 x 1.501.1251323383227524136695246916457885101746
0.75 x 2.001.500183150433769554893696112185761187132361
1.00 x 1.001.000122133282446373262464180575079591540
1.00 x 1.501.500183150433769554893696112185761187132361
1.00 x 2.002.0002442675749927464124928216111410115810183181
1.00 x 3.003.0003663101867413911196186139123242171152237152747122
1.00 x 4.004.000488413511498185148129248185164323228203316203663163
1.50 x 1.001.500183150433769554893696112185761187132361
1.50 x 1.502.250274776645510483721391049218212811417711203592
1.50 x 2.003.0003663101867413911196186139123242171152237152747122
1.50 x 3.004.5005595152129111208167145279208
1.50 x 4.006.00073127202172148278222193372278246485342305474315494245
2.00 x 1.002.0002442675749927464124928216111410115810183181
2.00 x 1.503.0003663101867413911196186139123242171152237152747122
2.00 x 2.004.000488413511498185148129248185164323228203316203663163
2.00 x 3.006.00073127202172148278222193372278246485342305474315494245
2.00 x 4.008.000971692702291973712972584963713286474574066324173126327
2.00 x 5.0010.0001222123382872474633713236204634108095715087905291158409
2.50 x 3.007.500911592532151853472782424653473076074283815933968118307
3.00 x 1.003.0003663101867413911196186139123242171152237152747122
3.00 x 2.006.00073127202172148278222193372278246485342305474315494245
3.00 x 3.009.0001101913042582224173342905584173697285144577114782142368
3.00 x 4.0012.00014625440534429655644538774455649297168561094962109189491
3.00 x 5.0015.0001833185074313706955574849306956151214857762118678137237614
4.00 x 1.506.00073127202172148278222193372278246485342305474315494245
4.00 x 2.008.000971692702291973712972584963713286474574066324173126327
4.00 x 3.0012.00014625440534429655644538774455649297168561094962109189491
4.00 x 4.0016.0001953395404593957425945169927426561295914813126583146253655
4.00 x 5.0020.00024442467657449492774364612409278201619 1142 1017 1581104182316819
6.00 x 4.0024.00029350981168959311138917751488 1113984
Panduit Wiring Duct wire lls are calculated using the following general formula:
Why use a 50% Wire Fill?
As specied in NFPA79-2012 section 13.5.2, Percentage Fills of
Raceways (Ducts), a 50% wire ll is given as the maximum wire ll capacity in
all Panduit Wiring Ducts. This helps ensure general safe wiring practices are
followed. In actual practice, a 50% wire ll is the maximum amount of wiring
the duct can hold given the additional airspace created between cables by
non-uniform cable shapes, cable interlacing, and cable packing factors.
Wire Area
The wire area formula is converted
to allow calculation using the
cable diameter:
Formula Derivation
Inserting the elements from above into the
general formula results in the following:
Calculation of Internal Area
Air Space Allotment
What is the Usable Duct Area?
The usable area we dene as the calculation of
internal area that can be occupied by wires or
cables. Accounting for thickness of material, 90%
of the nominal area (WxH) is used in the formula.
Simplifying this formula results in the
formula used for wire ll calculation:
0
Note: When calculating wire ll capacity using the above formula, variables W, H, and D must be expressed in same units (i.e. mm or inches).
4
Part Numbering System for Panduct® Wiring Duct
G22
Type
G = Wide Slot
F = Narrow Slot
FL = Flexible Duct
FS = Solid Wall
H = Hinged Cover Wide Slot
HN = Hinged Cover, Narrow Slot
HS = Hinged Cover, Solid Wall
D = Round Hole
NNC = Halogen-Free, Metric
NE = Halogen-Free
MC = Narrow Slot, Metric
TNC = Low Smoke, Halogen-Free
Nominal Width
In. or mmLG = Light Gray
X
Nominal Height
In. or mm
Color
WH = White
BL = Black
IB = Intrinsic Blue
IG = International Gray
—
Length
6 ft. or 2m
Part Numbering System for Panduct® PanelMax™ DIN Rail Wiring Duct
DRD22LG
Type
DRD = DIN Rail DuctCapability Height
Size
22 = 2" Height
33 = 3" Height
44 = 4" Height
Color
LG = Light Gray
WH = White
6
Length
6 ft.
6LG
-A
Options
-A = Adhesive backed
NM = No mounting holes
= Leave blank for
no options
Part Numbering System for Panduct® PanelMax™ Corner Wiring Duct
CWD2LG
Type
CWD = Corner Wiring DuctCapability Height
Size
2 = 2" Height
3 = 3" Height
4 = 4" Height
Color
LG = Light Gray
WH = White
6
Length
6 ft.
Part Numbering System for Panduct® Wiring Duct Covers
C2LG
Type
C = Cover
HC = Hinged Cover
NC = Halogen-Free
TNC = Low Smoke, Halogen-Free
DRDC = DIN Rail Duct
Width
In. or mm LG = Light Gray
Color
WH = White
BL = Black
IB = Intrinsic Blue
IG = International Gray
6
Length
6 ft. or 2m
Panduct® PanelMax™
Shielded Wiring Duct
Shielded wiring duct is a Type G style duct with bridges
wrapped with an aluminum foil shield. Sold in 6 ft. lengths,
available in three (3) sizes and uses Type C covers and
uses standard cover part number C2LG6.
Panduct® PanelMax™ Noise Shield
Noise shield is zinc-plated steel and black powder coated
except at bonding locations. Each kit contains two (2) 3 ft.
sections and four (4) bonding clips.*
Part NumberSize (W x H)
G2X2LG6EMI2" x 2"
G2X3LG6EMI2" x 3"
G2X4LG6EMI2" x 4"
Part NumberSize (H)
SD2EMI2"
SD3EMI3"
SD4EMI4"
*Additional bonding clips available – SDCLIP (2 per package).
5
Wiring Duct Material Properties
Rigid Polyvinyl Chloride (PVC)
A general purpose lead-free material for indoor applications. It has a UL 94 ame class of V-0 with a UL recognized continuous-use
temperature up to 50°C (122°F). Used in the manufacture of the following types of Panduit wiring duct and covers: G, F, D, FS, MC, H,
HN, HS, CWD, DRD.
Halogen-Free, Polyphenylene Oxide (PPO)
A special purpose material for use in halogen-free or high-temperature applications. It has a UL 94 ame class of V-0 with a UL
recognized continuous-use temperature up to 95°C (203°F) and is 20% lighter than PVC. Used in the manufacture of the following types
of Panduit wiring duct and covers: NE and NNC.
A special purpose material for use in low-smoke, halogen-free, and high-temperature applications. It has a UL 94 ame class of V-0
with a UL recognized continuous-use temperature up to 105°C (221°F). Meets the regulatory requirements of the mass transit industry
and other applications where re and public safety are critical; such as in trains, buses, offshore oil and gas platforms, and other similar
environments. Used in the manufacture of Type TNC wiring duct and covers.
Polypropylene (PP)
A exible material with a UL 94 ame class of V-2 with a UL recognized continuous-use temperature up to 65°C (149°F). Used in the
manufacture of Type FL exible wiring duct.
Recommended Precaution when using Type NE, NS, NNC, and TNC Wiring Duct
Cleaning solvents and cutting uids that contain any of the following chemical agents should not come into contact with these types of
wiring duct or covers. These chemicals are the most commonly known to cause stress cracking.
• Hydrocarbons
• Phenols
• Ketones
• Amines
• Ethers
• Organic, inorganic, and oxidizing acids
• Petrol
Refer to www.panduit.com for more information on chemical resistance.
Unmatched Expertise
Panduit continually invests in resources to solve your greatest business and technology challenges. Our network of sales, technical
support, distribution, and manufacturing teams are readily accessible to help you with your project needs.
6
Complete Your Installation with Accessories and Installation Tools
Type NNC Wiring Duct Classification = F3/I4
Type TNC Wiring Duct Classification = F1/I4NNC and TNC
Pass 30-second flame application
Surface Flammability: < 35
Smoke Density D
Ds (4.0) < 200
Non-metallic duct shall be permitted (inside enclosures) only when they
are made with a flame-retardant material; flame-retardant material is
defined in the standard by the IEC 60332-1 test method
Panduit publishes a maximum percentage wire fill for common wire
types equal to 50% of the interior cross-sectional area of the wiring duct
Panduit bend radius control accessories can be mounted at right angles
and T junctions created using wiring duct in order to maintain cable
bend radius control
(1.5) < 100
s
NNC and TNC
MC, NNC,
and TNC
TNC
TNC
TNC
All wiring duct
types and covers
(except FL)
All wiring duct
types and covers
Corner strip with
1" bend radius
control
European Union
European
Directive
2011/65/EU
Meets the requirements on the Restriction of Hazardous Substances
and is free of the six substances listed in the directive