ORDER NO.AVS9810128C1
D2
Vari-Focal Lens
WV-LZ62/8
SPECIFICATIONS
Image Size: φ6 mm [4.8 (H) X 3.6 (V) mm]
Focal Length: 5 – 40 mm
Maximum Aperture Ratio: 1 : 1.6 (Wide), 1 : 1.9 (Tele)
Angular Field of View
H: 6.6° – 52°
V: 5.0° – 39.6°
Focusing Range: 1.2 m – ∞ (3.9 ft - ∞)
Mount: CS-mount, 1”-32UN
Ambient Operating Temperature: –10°C – +50°C
Dimensions: 61(W) x 52(H) x 65(D) mm
2-3/8”(W) x 2-1/16”(H) x 2-9/16”(D)
Weight: 110 g (0.24 lbs.)
Dimensions and weight indicated are approximate.
Specifications are subject to change without notice.
©1998 Matsushita Communication Industrial Co.,Ltd.
All rights reserved. Unauthorized copying and distribution
R
is a violation of law.
WV-LZ62/8
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
CAUTION:
TO REDUCE THE RISK OF ELECTRIC SHOCK,
DO NOT REMOVE COVER (OR BACK). NO USER
SERVICEABLE PARTS INSIDE.
REFER SERVICEING TO QUALIFIED SERVICE
PERSONNEL.
This symbol warns the user that uninsuland voltage
within the unit may have sufficient magnitude to cause
electric
shock. Therefore, it is dangerous to make any kind of
contact with any inside part of this unit.
This symbol alerts the user that impotant literature concerning
the operation and maintenance of this has been included.
Therefore, it should be read carefully in order to avoid
There are special components used in this equipment which are important for safety. These parts are indicated
by the mark on the schematic diagram and the replacement parts list. It is essential that these critical
parts should be replaced with manufacturer's specified parts to prevent X-radiation, shock, fire, or other hazards.
Do not modify the original design without permission of manufacture.
IMPORTANT SAFETY NOTICE
This service information is designed for experienced repair technicians only and is not designed for use by the
general public.
It does not contain warnings or cautions to advise non-technical individuals of potential dangers in attempting to
service a product.
Products powered by electricity should be serviced or repaired only by experienced professional technicians. Any
attempt to service or repair the product or products dealt with in this service information by anyone else could
result in serious injury or death.
!
WARNING
REPLACEMENT PARTS LIST
Important Notice
1. Components identified by " ! " mark have special characteristics important for safety.
When replacing any of these components, use only manufacturer's specified parts.
2. RTL : Retention Time Limited (No longer available after discontinuing product).
REF. NO. PART NO. DESCRIPTION REF. NO. PART NO. DESCRIPTION
MISCELLANEOUS
M1 YWWCC329A012 Front Cap
M2 YWBCC329A109 Iris Cover
M3 YWBCC317A112 Cord Clamp
M4 YWBCC317A103 Focus Ring
M5 YWBCC329A113 Wave Washer
M6 YWBCC329A105 Zoom Ring
M7 YWBCC329A114 C Ring
M8 YWBCC329A106 Iris Assy
M9 YWBCC317A121 Lock Knob
M10 YWWCC007A005 Rear Cap
M11 YWV8QA5076AN Operating Instructions
M12 YWV9CA3904AN Packaging Assy
ACCESSORY PARTS / PAKAGING PARTS