Panasonic VLGM001A User Manual

Page 1
Video Intercom System
Sub Monitor Station
Installation and Operation Guide
Model No. VL-GM001A
Thank you for purchasing a Panasonic Sub Monitor Station.
Please read this Installation and Operation Guide before using the unit and save for future reference.
Page 2
Important Information
FCC and Other Information ....................................................................................... 2
Important safety instructions ..................................................................................... 3
Additional safety information ..................................................................................... 4
For best performance ................................................................................................ 5
Introduction and Installation
Included items............................................................................................................ 6
Location of controls ................................................................................................... 7
Before installation ...................................................................................................... 8
Installing the sub monitor station ............................................................................. 10
Help
Cleaning ................................................................................................................... 17
General Information
Technical data about this product ............................................................................ 18
FCC and Other Information
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference received, including interference that may cause
undesired operation.
CAUTION:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
2
Page 3
CAUTION
RISK OF ELECTRIC SHOCK
DO NOT OPEN
The lightning flash with arrow head within a triangle is intended to tell the user that parts inside the product are a risk of electric shock to persons.
Important safety instructions
1) Read these instructions. All the safety and operating instructions should be read before the appliance is operated.
2) Keep these instructions. The safety and operating instructions should be retained for future reference.
3) Heed all warnings. All warnings on the appliance and in the operating instructions should be adhered to.
4) Follow all instructions. All operating and use instructions should be followed.
5) Do not use this apparatus near water. For example, near a bathtub, wash bowl, kitchen sink, or laundry tub, in a wet basement, or near a swimming pool, and the like.
6) Clean only with dry cloth. Do not use liquid cleaners or aerosol cleaners. Use a dry cloth for cleaning.
7) Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions. Slots and Openings in the cabinet are provided for ventilation and to ensure reliable operation of the product and to protect it from overheating. The openings should never be blocked by placing the product on a bed, sofa, rug, or other similar surface.
8) Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat. This product should not be placed in a built-in installation such as a bookcase or rack unless proper ventilation is provided or the manufacturer’s instructions have been adhered to.
9) Do not defeat the safety purpose of the
10) Protect the power cord from being walked
11) Only use attachments / accessories
12) Unplug this apparatus during lightning
13) Refer all servicing to qualified service
The exclamation point within a triangle is intended to tell the user that important operating and servicing instructions are in the papers with the appliance.
polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
specified by the manufacturer.
storms or when unused for long periods of time. This will prevent damage to the product due to lightning and power-line surges.
personnel. Servicing is required when the apparatus has been damaged in any way, such as power- supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
SAVE THESE INSTRUCTIONS
3
Page 4
Additional safety information
1. Use only the power source marked on the unit. If you are not sure of the type of power supplied to your home, consult your dealer or local power company.
2. Use only the specified AC adaptor.
3. Do not tamper with the plug.
4. Make sure the plug is securely inserted.
5. Do not touch the plug with wet hands.
6. Do not place objects on the power cord. Install the unit where no one can step or trip on the cord.
7. To reduce the risk of electric shock, do not disassemble this unit. Take the unit to an authorized service center when service is required. Opening or removing covers may expose you to dangerous voltages or other risks. Incorrect reassembly can cause electric shock when the unit is subsequently used.
8. Unplug this unit from power outlets and refer servicing to an authorized service center when the following conditions occur: A. If smoke rises, or an unaccustomed noise or smell is discharged from the unit. B. If metal objects have been dropped inside the sub monitor station.
9. Do not put your ear(s) near the speaker, as loud sounds emitted from the speaker may cause hearing impairment.
10. Only a qualified technician is allowed to connect a power cable to the unit. Contact an authorized service center.
11. Do not make any wiring connections when the power supply is turned on.
12. Never install wiring during a lightning storm.
13. Do not connect a power cable other than the specified voltage.
14. Do not connect the power cable to any terminal other than the one specified.
15. When existing chime wires are used, it is possible that they contain AC voltage. Electric shock or unit damage could result. Contact an authorized service center.
16. Never touch the inside of the sub monitor station. High voltage is present.
17. Make certain when mounting the unit to any wall surface that the method used will hold the weight of the unit properly.
18. If the wiring is outdoors, use a protection tube or a surge protector.
19. If the wiring is underground, do not make any connections underground.
20. WARNING – To Reduce The Risk Of Fire Or Electric Shock, Do Not Expose This Apparatus To Rain Or Moisture.
21. WARNING – Unplug this unit from power outlets if it emits smoke, an abnormal smell or makes unusual noise. These conditions can cause fire or electric shock. Confirm that smoke has stopped and contact an authorized service center.
4
Note:
This product has a fluorescent lamp that contains a small amount of mercury. It also contains
lead in some components. Disposal of these materials may be regulated in your community due to environmental considerations. For disposal or recycling information please contact your local authorities, or the Electronics Industries Alliance: <http://
www.eiae.org.>
Page 5
For best performance
If a power failure occurs, the unit will not function.
Do not place any object within 20 cm (8 inches) of the sub monitor station. This may
cause communication errors or malfunction.
5
Page 6
Introduction and Installation
Included items
No. Item Notes
Sub Monitor station
Wood screws
AC adaptor
Wood screws 2
Power cord 1 ------
Power cable
Quantity
1 ------
4
1
1
For the sub monitor station. 4 mm x 35 mm (
Enclosed in the AC adaptor case.
For the AC adaptor case. 4 mm x 16 mm (
3
3
/
16
/
16
------
x 1
x
3
)
/
8
5
)
/
8
Sub Monitor Station:
A Sub Monitor Station is an optional unit which, when used through the Monitor Station, operates just like the Monitor Station. Up to two of these units can be connected to the system.
6
Page 7
Introduction and Installation
Location of controls
Front view
Display (3.5-inch color LCD screen)
Microphone
Speak into the microphone when talking to a visitor.
SELECT () button / BRIGHT button
SELECT () button / RECEIVE VOLUME button
MENU button / PRESS TALK button
MONITOR button
Allows you to monitor the sound and camera image from the door station.
DOOR button
Allows you to open the door.
TALK button
To answer a door call and/or speak to the visitor.
CALL button
To call another monitor unit.
Speaker
* Ventilation holes are located at the bottom. (Do not cover these.)
7
Page 8
Introduction and Installation
Before installation
To avoid malfunction or communication disturbance, do not install the sub monitor station in the following locations: – Places where vibration or any other kind of impact occurs. – Places where echoing is frequent. – Places where a high concentration of dust, hydrogen sulfide, phosphorus,
ammonia, sulfur, carbon, acid, or noxious fumes occur.
– Within 2 m (6′7″) of a TV, microwave, personal computer, air conditioner or any
other electrical device.
The sub monitor station and AC adaptor are for indoor use only. Do not use it outdoors, otherwise it may malfunction.
Use the flush mount unit (sold separately) when installing the sub monitor station
into a wall. – Refer to the Installation and Operation Guide that is included with the flush
mount unit for details on installing the flush mount unit.
Standard installation position of the sub monitor station
Place the sub monitor station in a location so that your eyes are the same height as the center of the display.
Note:
In areas surrounded by high electrical field, disturbance may occur in the sub
monitor station’s image or sound.
Be sure to install the sub monitor station more than 5 m (16′5) away from the
door station.
Please check that there is a partition of a wall etc. between a monitor station and
sub monitor station and attach them.
Do not place any objects within 20 cm (8 inches) of the sub monitor station. This
may cause communication errors or malfunction.
Do not install the sub monitor station inside a wall, without using the flush mount
unit.
8
Page 9
Introduction and Installation
Wiring schematic diagram
All monitor stations and sub monitor stations should be connected by daisy chain wiring method. The connection of 2nd sub monitor station (the last end terminal) and monitor station is NOT required.
Sub Monitor station VL-GM001A
Connect to terminals H11 and H12 of the monitor station.
H11 H12 H21 H22 K1 K2
AC adaptor
Chime
Connect to terminals H21 and H22 of the sub monitor station.
NOTE:
This chime wiring schematic diagram is only an example.
Refer to the wiring instruction provided with your chime for detail.
Refer to the technical data on page 18 when connecting to a chime.
All connections are non polar.
Power cable/wire type and distance
Power cable (between the sub monitor station and the AC adaptor):
Type: ø1.2 Fire alarm cable 16 AWG Distance: Maximum 30 m (about 98 feet)
Wire (between the monitor station and the last sub monitor station):
Type: General cable CAT-3 24 AWG Distance: Maximum 100 m (about 328 feet)
120 V AC
9
Page 10
Introduction and Installation
Installing the sub monitor station 1 Remove the sub monitor station from the box, and then remove the padding
material from between the front case and the bottom case.
The front case and the bottom case are not joined together, so be careful not
to drop them when taking them out of the box.
Connector
Bottom case
2 Remove the terminal cover.
Padding material
Front case
Terminal cover
10
Bottom case
Page 11
Introduction and Installation
3 Install the bottom case to a wall using the wood screws
(4 mm x 35 mm,
Before drilling, see page 8 for installation location.
3
<Installation size>
/
16
x 1
3
).
/
8
11
Page 12
Introduction and Installation
4 Attach the power cable to the terminal. See page 16 for details on how to attach
the power cable.
If you want to use your own power cable, see page 9 for the type and distance.
<Inside of main unit (bottom case)>
5 Attach the wires that connect to the monitor station and sub monitor station to
the terminal. See page 16 for details on how to attach the wires.
See page 9 for the wire type and distance.
See the wiring schematic diagram on page 9.
12
Terminal (Non polar)
Button
Wire (Not included)
Power switch
When the front case is
attached, the power switch will be pressed and power will be supplied.
Page 13
Introduction and Installation
6 Remove the sheet covering the connector. Next, after
installing the terminal cover in the bottom case, attach the connector by tightening the connector screw. Next, align the lower portion of the bottom case with the lower portion of the front case and press on the panel area just above the screen until the tabs lock in place.
Check that there are no scraps from
the board or other debris in the connector before installing it.
Remove the front case from the bottom case While pushing the tabs at the top of the front case, pull the top of the front case
forward to disengage the front tabs one by one, and then pull the top of front case forward to remove it.
Connector screw
+
Screwdriver
Bottom case
Front case
Remove the connector screw, and then remove the connector.
Do not pull the wire when removing the connector.
13
Page 14
Introduction and Installation
7 Take out the AC adaptor and the DC terminal from the case.
Push the arrow mark on the front case, then release from the rear case.
Take out the cardboard and wood screws. The wood screws are necessary
when attaching the AC adaptor and the DC terminal to a wall (page 15).
Arrow mark
DC terminal AC adaptor
8 Connect the power cable to the DC terminal, the power cord to the AC adaptor,
then connect the power cord to the AC outlet (100 V – 240 V, 50 Hz / 60 Hz).
Be sure to connect the power cable to the 2 holes on the left side of the DC
terminal.
For details on how to attach the power cable, see page 16.
DC terminal AC adaptor Power cord
Power cable
9 Attach the DC cord to the clamp on the rear of the DC terminal.
This will help to avoid the DC cord to disconnect from the DC terminal.
DC terminal
Clamp
14
To AC outlet
DC cord
Page 15
Introduction and Installation
To attach the AC adaptor and the DC terminal to a wall
By placing the AC adaptor and the DC terminal in the case and mounting the case to the wall, you can protect the AC adaptor and the DC terminal from tampering and exposure.
Note:
Disconnect the DC cord from the clamp on the rear of the DC terminal beforehand.
See step 9 on page 14 for details.
Take out the cardboard and wood screws from the AC case beforehand.
1 Attach the rear part of the case to a wall using the wood screws (4 mm x 16 mm,
3
5
x
/
16
).
/
8
Wood screws
Case
Wall
83.5 mm
5
)
(
3
/
16
2 Pack the AC adaptor and DC terminal as shown.
Pack the AC adaptor in the rear case.
Be sure to run the power cord through the power cord hole.
Pack the DC cord in the rear case.
Be sure to bundle the DC cord so that it will not touch the bottom of the
case.
Pack the DC terminal in the rear case.
Be sure to run the wires through the wire hole, then under the wire rib.
Wire rib
Wire hole
DC terminal
DC cord
Power cord hole
3 Attach the front of the case.
AC adaptor
Power cord
15
Page 16
Introduction and Installation
Note:
To open the case again, push the bottom of the front case, then release from the
rear case.
To attach the power cable
Sub Monitor station
DC terminal
Button
Terminal connector
While pressing on the button hard with a pointed object such as a screwdriver,
insert the power cable into the terminal connector.
To disconnect the power cable, press on the button hard while pulling out.
To attach an optional power cable, cut off about 12 mm (
), then push in firmly until the end of the cable is securely inserted into the
( power connection terminal (
To attach the wires
).
Button
Terminal connector
1
) of the cable cover
/
2
Power cable cross section
Correct Incorrect
Strip off of the wire cover so that about 9 mm (
While pressing on the button with a pointed object such as a screwdriver, insert
the wire into the terminal connector.
To disconnect a wire, press on the button while pulling out.
3
) of the wire is exposed.
/
8
16
Page 17
Help
Cleaning
Clean the unit with a soft, dry cloth when cleaning. For excessive dirt, wipe the unit with a slightly damp cloth.
Important information:
Do not use anything containing alcohol, polish powder, powder soap, benzine,
thinner, wax, petroleum, or boiling water. Also do not spray with insecticide, glass cleaner, or hair spray. This could cause a change in color or quality.
17
Page 18
General Information
Technical data about this product
Sub Monitor station
Power supply: Current consumption:
Dimensions:
Mass (Weight): Operating environment:
Installation method:
External material:
Note:
To connect to a chime, make sure the chime is:
– Normal open (Low active) – Less than 30 V AC (1 A), 24 V DC (1 A)
AC adaptor (Part number: PFAP1014)
Power supply: Output voltage: Output current: Dimensions:
Mass (Weight): Operating environment:
24 V DC Standby: Approximately 38 mA At operation: Approximately 210 mA Approximately height 145 mm x width 165 mm x depth 44 mm
3
1
/
3
x 1
2
x 1
/
8
AC
3
)
/
4
, 50 Hz / 60 Hz
3
)
/
8
x 6
(5
/
4
Approximately 600 g (1.32 lb.) 0 °C to 40 °C (32 °F to 104 °F), Up to 90 % RH (Relative Humidity) non condensing Exposure mount Flush mount (Optional Flush mount unit is required.) Flame retardant ABS resin (panel: acrylic resin)
100 V – 240 V 24 V DC 2 A Approximately height 120 mm x width 60 mm x depth 35 mm
3
(4
x 2
/
4
Approximately 310 g (0.68 lb.) 0 °C to 40 °C (32 °F to 104 °F), Up to 90 % RH (Relative Humidity) non condensing
18
Note:
Design and specifications are subject to change without notice.
The pictures and illustrations in these instructions may vary slightly from the
actual product.
Page 19
19
Page 20
For your future reference
Date of purchase
Serial number (found on the rear of the unit)
Dealer’s name and address
Dealer’s telephone number
Attach your sales receipt here.
Panasonic Consumer Electronics Company, Division of Panasonic Corporation of North America
One Panasonic Way, Secaucus, New Jersey 07094, U.S.A.
Panasonic Puerto Rico, Inc.
San Gabriel Industrial Park, Ave. 65 de Infantería, Km. 9.5, Carolina, Puerto Rico 00985, U.S.A.
Copyright:
This material is copyrighted by Panasonic Communications Co., Ltd., and may be
reproduced for internal use only. All other reproduction, in whole or in part, is prohibited without the written consent of Panasonic Communications Co., Ltd.
© 2005 Panasonic Communications Co., Ltd. All Rights Reserved.
Printed in INDONESIA
LHQT0198
S0405-0
Loading...