Panasonic Toughpad FZ-M1 Certification

Testing is performed at an internationally recognized, independent research, engineering and evaluation laboratory who by contractual agreement with their clients does not allow the use of their name or logo because doing so may imply an endorsement of products or services. For this reason, all references to said independent third party lab have been removed. Should you require the full unedited version, please contact the company identified below.
Mechanical Engineering Division
SUMMARY OF TESTS PERFORMED
Project Number: 18.04481.25.101 Company: Panasonic System Communications Company
Two Riverfront Plaza Newark, NJ 07102 Attn: Mauricio Del Valle
Equipment Tested: Panasonic FZ-M1 Tablet Computer Test Dates: March 6, 2014 – March 26, 2014 Notes:
The test item was evaluated for ability to boot into the Windows 8 operating system following each of the tests described within this summary report or for the ability to play an audio/visual file during the test parameter application. A listing of summarized tests and results appear in the accompanying table. Report Number 18.04481.25.100.FR1.
Full details will be provided in
Report Written By: Eric Dornes Principal Engineer Structur al Dynamics and Product Assurance Section
Page 1
Summary of Tests Performed— Panasonic FZ-M1 Tablet Computer 04/22/14
PASS:
3/18/14
PASS:
3/18/14
PASS:
3/17/14
PASS:
3/19/14
High Temperature:
Operational
MIL-STD-810G, Method 50 1.5, Procedure III
(test for operation)
PASS:
3/21/14
PASS:
3/17/14
PASS:
3/17/14
PASS:
3/20/14
MIL-STD-810G, Method 50 6.5, Procedure I
Unit operating
PASS:
3/19/14
PASS:
3/18/14
PASS:
3/17/14
MIL-STD-810G, Method 51 0.5, Proc ed ure I
Non-Operating temperature of 160°F
PASS:
3/19/14
MIL-STD-810G, Method 51 0.5, Proc ed ure II
Non-Operating temperature of 160°F
PASS:
3/19/14
PASS:
3/14/14
MIL-STD-810G, Method 51 4.6, Procedure I
Panasonic provided conditions (operating)
PASS:
3/26/14
MIL-STD-810G, Method 51 4.6, Procedure I
operating)
Summary of Tests Performed on the Panasonic FZ-M1 Tablet Computer
Test Description Test Parameters Test Results
Altitude: Storage/Air
Transport
Altitude: Operation/Air
Carriage
High Temperature:
Storage
High Temperature:
Operation
Tactical–Standby to
Low Temperature:
Storage
Low Temperature:
Operation
Temperature Shock
Rain: Blowing
MIL-STD-810G, Method 50 0.5, Proc ed ure I
40,000ft Non-Operating
MIL-STD-810G, Method 50 0.5, Proc ed ure II
40,000ft Operating
MIL-STD-810G, Method 50 1.5, Procedure I
160°F Non-Operating, 7 days
MIL-STD-810G, Method 50 1.5, Procedure II (constant)
140°F Operating
High storage (non-operating) to high operating
MIL-STD-810G, Method 50 2.5, Procedure I
-60°F Non-Operating
MIL-STD-810G, Method 50 2.5, Procedure II
-20°F Operating
MIL-STD-810G, Method 50 3.5, Procedure I
From 200°F to -60°F, three cycles
5.8in/hr rain, 70mph wind, 30 minutes per surface
Completed
Completed
Completed
Completed
Completed
Completed
Completed
Completed
Completed
Rain: Drip
Humidity
Sand and Dust: Dust
Sand and Dust: Sand
Explosive Atmosphere MIL-STD-810G, Method 51 1.5, Procedure I
Vibration: General
Vibration – operating
Vibration: General
Vibration – non-
operating
MIL-STD-810G, Method 50 6.5, Proc ed ure III
MIL-STD-810G, Method 50 7.5, Procedure II (Aggravated)
(Transportation)
(Transportation)
15 minute exposure, drip test
Temp. cycles 86°F to 140°F; 95%RH
Blowing Dust (non-operating)
Blowing Sand (non-operating)
Category 24, general minimal integrity (non-
Page 2
Completed
Completed
Completed
Completed
Completed
Completed
PASS:
Completed
3/24/14
Loading...