Panasonic TB5560187 User Manual

PRODUCT TYPES
Model No. Product name Rated voltage Power failure backup TB5560187 Analogue type daily TIME SWITCH (with power failure backup) 220-240VAC 300 hours TB5630187 Analogue type weekly TIME SWITCH (with power failure backup) 220-240VAC 300 hours TB5590185 Analogue type daily TIME SWITCH 230VAC
__
TB5640185 Analogue type weekly TIME SWITCH 230VAC
__
TB5560187
CIRCUIT DIAGRAM
TB6110187 <1 Circuit type>
SPECIFICATIONS
FEATURES
DIN rail mount
DIN module size
15 minutes interval setting (Daily)
2 hours interval setting (Weekly)
Power supply indication LED lamp
3 state terminal (COM-NO-NC)
Metal setting pin
ON-OFF-AUTO switch
EN50178, DIN57633 conformed
APPLICATIONS
Lighting Fixture
Sign board
Factory facility
Vending machines
HIGH PERFORMANCE DIGITAL TYPE TIME SWITCHES
Model No. Program Cycle Driving Method Rated Voltage Allowable Operating Voltage Rated Frequency Power Consumption Time Indication Power Supply Indicator Number of Circuit Circuit Configuration Contact Configuration Manual ON/OFF Switching Capacity
Resistive Load (cosø=1)
Inductive Load (cosø=0.6) Setting System Minimum Setting Unit Minimum Setting Interval Number of Operation Running Reserve
Charging Time Time Accuracy Working Ambient T emparature Working Ambient Humidity Degree of Protection Protection Class Pollution Degree Over Voltage Category Wiring Terminal Capacity Weight Option Parts
Daily Type Weekly Type Daily Type Weekly Type
Quartz motor AC synchronous motor 220-240V AC 230V AC
-15% to + 10% of rated voltage
50-60Hz 50Hz
2W 2W
Daily dial Weekly dial Daily dial Weekly dial
Green LED Red LED
1-circuit
Separated Circuit (NO voltage-applied contact output)
Single Pole, Double-through ( ):µ−gap
with ON-AUTO-OFF Switch
250V AC 16A
250V AC 3A
Built-in Pin Setting (inside: ON, Outside: OFF) 15 minutes 2 hours 15 minutes 2 hours 15 minutes 2 hours 15 minutes 2 hours
96/Day 84/Week 96/Day 84/Week
300 hours at 20°C (Ni-Cd battery built-in) --­about 72 hours ---
±15 sec/month(at 25°C) Same as AC frequency
-20°C~+55°C
-85%RH or less
IP 20 as per EN60529
Class II as per EN60335-1 if istalled as directed
2
III
1~2.5mm
2
160g 160g TB55603777 / Terminal Cover
TB5560187 TB5630187 TB5590185 TB5640185
TIME SWITCHES (TB5)
1
15
SAFETY INSTRUCTIONS
1. All operations serving transport, installation, commissioning, troubles­hooting and maintenance are to be carried out by skilled technical personnel in accordance with the relevant safety regulations and standards.
2. Avoid using the time switch except for the environment condition shown in specifications. Indoor use only.
3. Load capacity differs, depending on the type of load. (See specifications).
4. Protect the circuit with a fuse ir breaker at the power supply, in accor
ONS
dance with the relevant regulations.
5. Synchronous motor type (TB559 .TB564) are not provided with run­ning reserve function. When the time error occurs due to power failure, readjust the present time.
6. Make wiring connections, using isnulated wire (1,0 to 2,5 mm
2
). Flexible codes conductors 1,0 to 2,5mm2. Fixed wiring conductors 1,5 to 2,5mm2.
7. After wiring, check that wiring connections are all correct.
05/2005
54
POWER
16
17
8
1
1
5
1
9
4
1
1
0
3
2
1
1
2
2
1
2
1
2
1
3
45 90
0
2
1
4
9
0
2
1
5
8
1
7
2
PIN
3
6
5
4
INSIDE NO- ON NC - OFF
PRESENT
TIME
3
5
4
2
1
66,5
61 44
M
~
1
POWER COM NO
4
3
2
5
NC
33
TB 5
2
OPERATING INSTRUCTIONS
1. Set all setting pins to the outside of the dial.
2. Set the pins to the inside of dial, corresponding to the peri­od when the „ON“ function is required.
CAUTION:
During this operation, do not operate the setting pins located near the present time index. Before operating these pins, turn the Time adjust knob to move them away of the present time.
Example:
The time chart corresponding to the pin setting is shown below.
PARTS IDENTIFICATION
* The figure shows TB556 series
1 Power supply indication lamp.
Quartz motor type: GREEN
Synchronous motor type: RED 2 Time adjust knob. 3 Setting pin. 4 ON-AUTO-OFF switch 5 Main dial.
24 hour dial (TB556 · TB559)
1 week dial (TB563 · TB564)
6 Sub-dial
60 min dial (TB556 · TB559)
24 hour dial (TB563 · TB564) 7Present time index. 8 DIN rail fixture.
3. Adjust the present time. Turn the Time adjust knob in the arrow direction.
CAUTION:
Unnecessary reverse rotation results in malfunctions.
TB556 TB559 TB563 TB564
4. Set the ON-AUTO-OFF switch. The load can be turned ON and OFF independent of the program by operating the ON-AUTO-OFF switch.
Operation method of switch
Between and Between and
Permanently ON Permanently OFF
Permanently OFF Permanently ON
Program setting
NCCOMNOCOM
5. Charging Battery (TB556 · TB563)
Supply AC power to the time switch. The battery will be automatically recharged.If the battery is charged for 3 days, 300-hour power failure will be backed-up.
(When it is charged for one hour, approx. 4-hour power failure will be compensated for.)
Frequent power failure and long-power failure exceeding the compensation time will shorten the battery life.
Quartz motor type (TB556 · TB563) contains Nickel-Cadmium battery. The battery must be recycled or
disposed of properly.
05/2005
PIN INSIDE NO- ON NC - OFF
PRESENT
TIME
1
POWER
16
17
18
15
14
19
13
20
21
22
23
24
2
12
11
10
10
9
15
8
1
7
2
3
6
5
4
3
5
4
Loading...
+ 1 hidden pages