PANASONIC S60MU1E51, S90MU1E51, S73MU1E51, S73MF2E5, S56MF2E5 User Manual

...
Page 1
* Shows U1 type (4-Way Cassette)
Operating Instructions
Air Conditioner
Model No.
Indoor Units
4-Way Cassette (U1 type) S-22MU1E51 S-28MU1E51 S-36MU1E51 S-45MU1E51 S-56MU1E51
S-73MU1E51 S-90MU1E51 S-106MU1E51 S-140MU1E51 S-160MU1E51
S-60MU1E51
FRANÇAIS
Avant d’utiliser l’appareil, lisez ce mode d’emploi dans son intégralité et conservez-le pour toute référence ultérieure.
ESPAÑOL
Antes de operar la unidad, lea atentamente estas instrucciones de funcionamiento y guárdelas para futuras consultas.
DEUTSCH
Bevor Sie das Gerät in Betrieb nehmen, lesen Sie bitte diese Bedienungsanleitung aufmerksam durch und bewahren Sie sie für die künftige Verwendung auf.
ITALIANO
Prima di utilizzare l’unità, leggere a fondo queste istruzioni per l’uso e conservarle come riferimento futuro.
NEDERLANDS
Lees deze gebruiksinstructies goed door voor u het apparaat gebruikt en bewaar ze voor toekomstig gebruik.
PORTUGUÊS
Antes de utilizar o aparelho, leia completamente este manual de instruções e guarde-o para futuras referências.
EΛΛΗΝΙΚΆ
Πριν θέσετε τη μονάδα σε λειτουργία, διαβάστε πολύ καλά αυτές τις οδηγίες χρήσης και διατηρήστε τις για μελλοντική αναφορά.
БЪЛГАРСКИ
Преди да започнете експлоатация на този уред, прочетете внимателно тези инструкции и ги запазете, за да можете да правите справки с тях и в бъдеще.
РУССКИЙ
Перед использованием этого устройства внимательно прочитайте настоящую инструкцию по эксплуатации и сохраните ее для дальнейших справок.
УКРАЇНСЬКА
Уважно прочитайте цю інструкцію з експлуатації перед тим, як увімкнути пристрій, та збережіть її на майбутнє.
B.INDONESIA 136 ~ 147
Sebelum mengoperasikan unit, baca petunjuk pengoperasian ini secara menyeluruh dan simpan untuk referensi mendatang.
Indoor Units
Low Silhouette Ducted
(F2 type) S-22MF2E5 S-28MF2E5 S-36MF2E5 S-45MF2E5 S-56MF2E5
S-73MF2E5 S-90MF2E5 S-106MF2E5 S-140MF2E5 S-160MF2E5
S-60MF2E5
ENGLISH 2 ~ 13
Before operating the unit, read these operating instructions thoroughly and keep them for future reference.
Outdoor Units
mini
(LE1 type)
Outdoor Units
2WΑΥ (ME1 type)
U-8ME1E81 U-10ME1E81 U-12ME1E81 U-14ME1E81 U-16ME1E81 U-18ME1E81 U-20ME1E81
Outdoor Units
3WΑΥ
(MF1 type)
U-8ME1E8(E) U-10ME1E8(E) U-12ME1E8(E) U-14ME1E8(E) U-16ME1E8(E)
U-8MF1E8
U-10MF1E8
U-12MF1E8
U-14MF1E8
U-16MF1E8 U-18ME1E8(E) U-20ME1E8(E)
14 ~ 25
26 ~ 37
38 ~ 49
50 ~ 61
62 ~ 73
74 ~ 85
86 ~ 97
98 ~ 109
110 ~ 121
122 ~ 134
© Panasonic Corporation 2012 Unauthorized copying and distribution is a violation of law.
F568275
Page 2
CONTENTS
PRODUCT INFORMATION...........................................................................................................2
SAFETY PRECAUTIONS..............................................................................................................2
INSTALLATION LOCATION...........................................................................................................3
ELECTRICAL REQUIREMENTS ..................................................................................................3
SAFETY INSTRUCTIONS.............................................................................................................4
INFORMATION..............................................................................................................................6
OPERATION..................................................................................................................................7
ADJUSTING AIRFLOW DIRECTION............................................................................................8
ADJUSTING AIRFLOW DIRECTION FOR MULTIPLE INDOOR UNITS USING SINGLE
REMOTE CONTROLLER (WIRED) ............................................................................................10
SPECIAL REMARKS ..................................................................................................................11
CARE AND CLEANING ..............................................................................................................11
TROUBLESHOOTING ................................................................................................................12
CHECK BEFORE REQUIRING SERVICES................................................................................13
TIPS FOR ENERGY SAVING.....................................................................................................13
SPECIFICATIONS.....................................................................................................................135
Page
PRODUCT INFORMATION
If you have problems or questions concerning your Air Conditioner, you will need the following information. Model and serial numbers are on the nameplate on the bottom of the cabinet.
Model No. _________________________________ Serial No. _______________________
Date of purchase ______________________________________________________________
Dealer’s address ______________________________________________________________
Phone number________________________________________________________________
SAFETY PRECAUTIONS
The following symbols used in this manual, alert you to potentially dangerous conditions to users, service personnel or the appliance:
This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death.
This symbol refers to a hazard or unsafe practice which can result in personal injury or product or property damage.
2
Page 3
INSTALLATION LOCATION
• We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit.
• Before installation, check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate.
• Do not install this air conditioner where there are fumes or flammable gases, or in an extremely humid space such as a greenhouse.
• Do not install the air conditioner where excessively high heat-generating objects are placed.
Avoid: To protect the air conditioner from heavy corrosion, avoid installing the outdoor unit where
salty sea water can splash directly onto it or in sulphurous air near a spa.
ELECTRICAL REQUIREMENTS
1. All wiring must conform to the local electrical codes. Consult your dealer or a qualified
electrician for details.
2. Each unit must be properly grounded with a ground (or earth) wire or through the supply
wiring.
3. Wiring must be done by a qualified electrician. The wires in this mains lead are colored in accordance with the following code:
Green-and-Yellow: Earth Blue: Neutral Brown: Live
As the colors of the wires in the mains lead of this appliance may not correspond with the colored markings identifying the terminals in your plugs, proceed as follows: The wire which is colored green and yellow must be connected to the terminal in the plug which is marked by the letter E or by the safety earth symbol or colored green or green-and-yellow. The wire which is colored blue must be connected to the terminal which is marked with letter N or colored black. The wire which is colored brown must be connected to the terminal which is marked with the letter L or colored red.
To warm up the system, the power mains must be turned on at least five (5) hours before operation. Leave the power mains ON unless you will not be using this appliance for an extended period.
Power mains
ON
NOTE
Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply when not in use for a long time.
3
Page 4
SAFETY INSTRUCTIONS
• Read these Operating Instructions carefully before using this air conditioner. If you still have any difficulties or problems, consult your dealer for help.
• This air conditioner is designed to give you comfortable room conditions. Use this only for its intended purpose as described in these Operating Instructions.
Confirm to authorized dealer or specialist on usage of specified refrigerant type. Using of refrigerant other than the specified type may cause product damage, burst and injury etc.
Never touch the unit with wet hands. Never use or store gasoline or other flammable vapor or
liquid near the air conditioner — it is very dangerous. Do not use this appliance in a potentially explosive
atmosphere. This air conditioner has no ventilator for intaking fresh air
from outdoors. You must open doors or windows frequently when you use gas or oil heating appliances in the same room, which consume a lot of oxygen from the air. Otherwise there is a risk of suffocation in an extreme case.
Provide a power outlet to be used exclusively for each unit, and a power supply disconnect, circuit breaker and earth leakage breaker for overcurrent protection should be provided in the exclusive line.
Provide a power outlet exclusively for each unit, and full disconnection means having a contact separation in all poles must be incorporated in the fixed wiring in accordance with the wiring rules.
To prevent possible hazards from insulation failure, the unit must be grounded.
Do not clean inside the indoor and outdoor units by users. Engage authorized dealer or specialist for cleaning.
In case of malfunction of this appliance, do not repair by yourself. Contact to the sales dealer or service dealer for a repair.
Refrigerant gas leakage may cause fire. For safety, be sure to turn the air conditioner off and
also to disconnect the power before cleaning or servicing.
Pull off the power plug from a receptacle, or switch off the breaker, or switch off the power disconnecting mean to isolate the air conditioner from the main power supply in case of emergency.
Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit, rotating parts may cause injury.
Do not use modified cord, joint cord, extension cord or unspecified cord to prevent overheating and fire.
Stop using the product when any abnormality/failure occurs and disconnect the power plug or turn off the power switch and breaker. (Risk of smoke/fire/electric shock) Examples of abnormality/failure
• The ELCB trips frequently.
• Burning smell is observed.
• Abnormal noise or vibration of the unit is observed.
• Water leaks from the indoor unit.
• Power cord or plug becomes abnormally hot.
• Fan speed cannot be controlled.
• The unit stops running immediately even if it is switched on for operation.
• The fan does not stop even if the operation is stopped.
Contact immediately your local dealer for maintenance/ repair.
Do not turn the air conditioner on and off from the power mains switch. Use the ON/OFF operation button.
Do not stick anything into the air outlet of the outdoor unit. This is dangerous because the fan is rotating at high speed.
Do not touch the air inlet or the sharp aluminum fins of the outdoor unit. You may get injured.
Keep the fire alarm and the air outlet at least 1.5m away from the unit.
This appliance is not intended for use by persons(including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that do not play with the appliance.
Do not cool or heat the room too much if babies or invalids are present.
Do not sit or step on the unit. You may fall down accidentally.
Do not stick any object into the FAN CASE. You may be injured and the unit may be damaged.
4
Page 5
Examples of abnormality/ failure
NOTICE
• The compressor may occasionally stop during thunderstorms. This is not a mechanical failure. The unit automatically recovers after a few minutes.
• The English text is the original instructions. Other languages are translation of the original instructions.
Stop using the product when any abnormality/failure occurs and disconnect the power plug.
(Risk of smoke/fire/electric shock)
- The product sometimes does not start when turned on.
- The power is sometimes disconnected when the cord is moved.
- Burnt odor or abnormal noise is detected during operation.
- The body is deformed or abnormally hot.
Contact immediately your local dealer for maintenance/repair.
5
Page 6
INFORMATION
Operation Condition
Use this air conditioner under the following temperature range.
Indoor temperature range: Cooling mode 14°C ~ 25°C (*WBT) / 18°C ~ 32°C (*DBT) Heating mode 16°C ~ 30°C (*DBT)
mini
Outdoor temperature range: Cooling mode -15°C ~ 46°C (*DBT) Heating mode -20°C ~ 18°C (*WBT) / -20°C ~ 24°C (*DBT)
Outdoor temperature range:
2WAY
Cooling mode -10°C ~ 43°C (*DBT) Heating mode -25°C ~ 20°C (*WBT)
Outdoor temperature range:
3WAY
Cooling & Heating mode -10°C ~ 43°C (*DBT) Cooling mode -10°C ~ 43°C (*DBT) Heating mode -25°C ~ 15°C (*WBT)
*DBT: Dry bulb temperature *WBT: Wet bulb temperature
Information for Users on Collection and Disposal of Old Equipment and Used Batteries
These symbols on the products, packaging, and/or accompanying documents mean that used electrical and electronic products and batteries should not be mixed with general household waste. For proper treatment, recovery and recycling of old products and used batteries, please take them to applicable collection points, in accordance with your national legislation and the Directives 2002/96/EC and 2006/66/EC. By disposing of these products and batteries correctly, you will help to save valuable resources and prevent any potential negative effects on human health and the environment which could otherwise arise from inappropriate waste handling. For more information about collection and recycling of old products and batteries, please contact your local municipality, your waste disposal service or the point of sale where you purchased the items. Penalties may be applicable for incorrect disposal of this waste, in accordance with national legislation.
For business users in the European Union
If you wish to discard electrical and electronic equipment, please contact your dealer or supplier for further information.
[Information on Disposal in other Countries outside the European Union]
These symbols are only valid in the European Union. If you wish to discard these items, please contact your local authorities or dealer and ask for the correct method of disposal.
Note for the battery symbol (bottom two symbol examples):
This symbol might be used in combination with a chemical symbol. In this case it complies with the requirement
Pb
set by the Directive for the chemical involved.
6
Page 7
OPERATION
Names of Parts
INDOOR UNIT
U1 Type (4-WAY CASSETTE) F2 Type (LOW SILHOUETTE DUCTED)
Water drain
Ceiling panel (optional)
Air outlet duct
Suspension bolt
Bolt anchor
Air outlet (4 locations)
Air intake grille (air intake)
Air-outlet grille
Wireless Remote Controller (Optional parts)
NOTE
Refer to the Operating Instructions attached to the optional Wireless Remote Controller.
Timer Remote Controller (Optional parts)
NOTE
Refer to the Operating Instructions attached to the optional Timer Remote Controller.
Indoor unit
Ceiling material
(Wireless type: available
for all indoor units)
(Wired type: available
for all indoor units)
7
Page 8
ADJUSTING AIRFLOW DIRECTION
The functions differ depending on the indoor unit used. The airflow direction cannot be set using the remote controller for any unit which is not listed below. U1 type.
• Never use your hands to move the flap (vertical airflow flap) that is controlled using the remote controller.
• When the air conditioner is turned off, the flap (vertical airflow flap) automatically moves to the downward position.
• The flap (vertical airflow flap) moves to the upward position when performing the standby operation for heating. The swing operation is made after the standby operation for heating is released, but swing is indicated on the remote controller even during the standby operation for heating.
Setting the airflow
direction
To activate the swing
operation
Heating Cooling and drying Fan operation All operations
Set the flap (vertical airflow flap) to the downward position. If the flap is set to the upward position, the warm air may not reach the floor.
The airflow direction changes each time the FLAP button is pressed during operation.
Press the FLAP button to set the flap (vertical airflow flap) to the downward position, and then press the FLAP button again. This displays , and the airflow automatically swings up and down.
The flap (vertical airflow flap) can be set to one of three positions.
Initial setting
Initial setting
Initial setting
Continuous operation
To stop the swing
operation
Press the FLAP button again during the flap swing operation to stop the flap at the desired position. Then, the airflow can be set from the top position by pressing the FLAP button again.
Indicator when swing operation is stopped
Fan and heating Cooling and drying
During cooling or drying operation, the flap will not stop at the downward position. Even if the flap is stopped at the downward position during the swing operation, it will not stop until it moves to the third position from the top.
8
Page 9
ADJUSTING AIRFLOW DIRECTION (CONTINUED)
U1 type air conditioner is equipped with auto flaps. You can set the airflow direction to a specific angle or to the sweep mode using the remote controller.
Do not move the flap with your hands.
4-way (U1 type) • The air outlet flap can be easily removed and washed with water.
• Be sure to always stop operation before removing the flap.
• After washing with water, allow it to dry, and then remount it with the arrow facing outward.
Concealed duct type (F2)
This air conditioner is not equipped with air outlet parts. These must be obtained locally. Please refer to the manual of the locally adopted air outlet parts.
9
Page 10
ADJUSTING AIRFLOW DIRECTION FOR MULTIPLE INDOOR UNITS USING SINGLE REMOTE CONTROLLER (WIRED)
• The airflow direction cannot be set using the remote controller for the concealed duct type (F2).
• If multiple indoor units are connected to a remote controller, the airflow direction can be set for each indoor unit by selecting the indoor units (see the operation below).
Auto Flap ( ) button
One outdoor unit and eight indoor units Two outdoor units and four indoor units
No display
Unit No.
1–1
• To set the airflow for individual units, press the UNIT button. Display shows the indoor unit number under group control. Set the airflow direction for the indoor unit that is shown on the display.
• Each time UNIT is pressed, the indicator changes in the order shown below.
• When nothing is displayed, you can make the setting for all indoor units in one operation.
• The unit number is displayed as Outdoor Unit Number–Indoor Unit Number. It varies depending on the number of units under group control.
Unit
Unit
Unit
Unit No.
1–2
Unit No.
1–3
Unit No.
1–8
No display
No.
1–1
No.
1–2
No. 1–3
Unit
No.
1–4
Unit
No.
2–1
Unit
No.
2–4
10
Page 11
SPECIAL REMARKS
‘‘DRY’’ Operation
How it works • Once the room temperature reaches the level that was set, the unit repeats the cycle of
Heating Operation
Heating performance • Because this appliance heats a room by utilizing the heat of the outside air (heat pump
Defrosting • When the outdoor temperature is low, frost or ice may form on the outdoor heat exchanger
(standby) on the
display
NOTE
turning on and off automatically.
• In order to prevent the humidity in the room from rising again, the indoor fan also turns off when the unit stops operating.
• The fan speed is set to ‘‘LO.’’ automatically, and cannot be adjusted.
• ‘‘DRY’’ operation is not possible if the outdoor temperature is 15 °C or less.
system), the heating efficiency will fall off when the outdoor temperature is very low. If sufficient heat cannot be obtained with this heat pump, use another heating appliance in conjunction with this unit.
coil, reducing the heating performance. When this happens, a microcomputer-controlled defrosting system operates. At the same time, the fan on the indoor unit stops (or runs at very low speed in some cases) and the ‘‘STANDBY’’ indicator appears on the display until defrosting is completed. Heating operation then restarts after several minutes. (This interval will vary slightly depending upon the outdoor temperature and the way in which frost forms.)
• For several minutes after the start of heating operation, the indoor fan will not start running (or it will run at very low speed in some cases) until the indoor heat exchanger coil has warmed up sufficiently. This is because a cold draft prevention system is operating. During this period, the ‘‘ ’’ (standby) indicator remains displayed.
• ‘‘ ’’ (standby) remains displayed during defrosting or when the compressor has been turned off (or when the unit is running at very low speed) by the thermostat when the system is in the heating mode.
• Upon completion of defrosting and when the compressor is turned on again, ‘‘ ’’ (standby) will turn off automatically as heating operation resumes.
Should the power fail while the unit is running
If the power supply for this unit is temporarily cut off, the unit will automatically resume operation (once the power is restored) using the same settings before the power was cut off.
Air intake and outlet side
(Indoor unit)
CARE AND CLEANING
1. For safety, be sure to turn the air conditioner off and also to disconnect the power before cleaning.
2. Do not pour water on the indoor unit to clean it. This will damage the internal components and cause an electric shock hazard.
Clean the air intake and outlet side of the indoor unit with a vacuum cleaner brush, or wipe them with a clean, soft cloth. If these parts are stained, use a clean cloth moistened with water. When cleaning the air outlet side, be careful not to force the vanes out of place.
1. Never use solvents or harsh chemicals when cleaning the indoor unit. Do not wipe plastic parts using very hot water.
2. Some metal edges and the fins are sharp and may cause injury if handled improperly; be especially careful when you clean these parts.
3. The internal coil and other components of the outdoor unit must be cleaned periodically. Consult your dealer or service center.
11
Page 12
TROUBLESHOOTING
If your air conditioner does not work properly, first check the following points before requesting service. If it still does not work properly, contact your dealer or a service center.
INDOOR UNIT
Symptom Cause
Noise Sound like streaming water during
Odor Discharged air is smelled during
Dewdrop Dewdrop gets accumurated near air
Fog Fog occurs during operation in cooling
Fan is rotating for a while even though operation stops.
Wind-direction changes while operating. Wind-direction setting cannot be made. Wind-direction cannot be changed.
When wind-direction is changed, flap operates several times and stops at designated position.
Dust Dust accumulation inside indoor unit is discharged. At the initial high-speed operation, the fan may
sometimes rotate faster (for 3 to 30 minutes) than the setting speed.
operation or after operation Cracking noise during operation or
when operation stops.
operation.
discharge during operation
mode. (Places where large amounts of oil mist exist at restaurants.)
OUTDOOR UNIT
Symptom Cause
No operation
Noise Noise often occurs in heating mode. During defrost operation Steam Steam often occurs in heating mode. When stopped by remote controller, outdoor unit fan
is sometimes operating for a while even though outdoor compressor is stopped.
When power is turned ON instantly. Operation is not acticated for the first approx. 3 minutes because When operation is stopped and
resumed immediately.
• Sound of refrigerant liquid flowing inside unit
• Sound of drainage water through drain pipe Cracking sound due to temperature changes of parts
Indoor odor components, cigarette odor and cosmetic odor accumurated in the air conditioner and its air is discharged. Unit inside is dusty. Consult your dealer.
Indoor moisture is cooled by cool wind and accumulated by dewdrop.
• Cleaning is necessary because unit inside (heat exchanger) is dirty. Consult your dealer as technical engineering is required.
• During defrost operation
• Fan rotating makes operation smoothly.
• Fan may sometimes rotates because of drying heat exchanger due to settings.
• When air discharge temperature is low or during defrost operation, horizontal wind flow is made automatically.
• Flap position is occasionally set up individually.
When wind-direction is changed, flap operates after searching for standard position.
This is for operation check in order to confirm whether the fan motor rotation is within use range.
compressor protection circuit is activated.
Fan rotating makes operation smoothly.
12
Page 13
CHECK BEFORE REQUIRING SERVICES
Symptom Cause Remedy
Air conditioner does not run at all although power is turned on.
Poor cooling or heating performance
If your air conditioner still does not work properly although you checked the points as described above, first stop the operation and turn off the power switch. Then contact your dealer and report the serial number and symptom. Never repair your air conditioner by yourself since it is very dangerous for you to do so. You also report if the inspection mark and the letters E, F, H, L, P in combination with the numbers appear on the LCD of the remote control unit.
Power failure or after power failure Press ON/OFF operation button on remote control
Operation button is turned off. • Switch on power if breaker is turned off.
Fuse blow out. If blown out, consult your dealer. Air intake or air discharge port of indoor
and outdoor units is clogged with dust or obstacles.
Wind speed switch is set to “Low”. Change to “High” or “Strong”. Improper temperature settings Refer to “TIPS FOR ENERGY SAVING”. Room is exposed to direct sunlight in
cooling mode. Doors and /or windows are open. Air filter is clogged. Refer to “CARE AND CLEANING”. Too much heat sources in room in
cooling mode. Too many people in room in cooling
mode.
unit again.
• If breaker has been tripped, consult your dealer without turning it on.
Remove dust or obstruction.
Use minimum heat sources and in a short time.
Reduce temperature settings or change to “High” or “Strong”.
TIPS FOR ENERGY SAVING
Avoid
• Do not block the air intake and outlet of the unit. If either is obstructed, the unit will not work well, and may be damaged.
• Do not let direct sunlight into the room. Use sunshades, blinds or curtains. If the walls and ceiling of the room are warmed by the sun, it will take longer to cool the room.
Do
• Always try to keep the air filter clean. (Refer to “CARE AND CLEANING”.) A clogged filter will impair the performance of the unit.
• To prevent conditioned air from escaping, keep windows, doors and any other openings closed.
NOTE
Should the power fail while the unit is running
If the power supply for this unit is temporarily cut off, the unit will automatically resume operation once power is restored using the same settings before the power was interrupted.
13
Page 14
SPECIFICATIONS
4-Way Cassette (U1 type)
Model Name Power Source
Cooling Capacity
Heating Capacity
High
Sound Pressure Level
Sound Power Level
Unit Dimensions (H×W×D) Net Weight
Model Name Power Source
Cooling Capacity
Heating Capacity
Sound Pressure Level
Sound Power Level
Unit Dimensions (H×W×D) Net Weight
Medium Low High Medium Low
High Medium Low High Medium Low
S-22MU1E51 S-28MU1E51 S-36MU1E51 S-45MU1E51 S-56MU1E51
220 - 230 - 240 V, single-phase, 50 Hz
kW
BTU/h
kW
BTU/h
dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)
mm
kg 27 27 27 27 27
kW
BTU/h
kW
BTU/h
dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)
mm
kg 28 28 31 31 31
2.2 2.8 3.6 4.5
7,500 9,600 12,300 15,400
2.5 3.2 4.2 5.0
8,500 10,900 14,300 17,100
30 30 30 31 29 29 29 29 28 28 28 28 47 47 47 48 46 46 46 46 45 45 45 45
290×950×950 290×950×950 290×950×950 290×950×950 290×950×950 290×950×950
S-73MU1E51 S-90MU1E51
220 - 230 - 240 V, single-phase, 50 Hz
7.3 9.0 10.6 14.0
24,900 30,700 36,200 47,800
8.0 10.0 11.4 16.0
27,300 34,100 38,900 54,600
37 38 44 45 32 35 38 39 29 32 34 35 54 55 61 62 49 52 55 55 46 49 51 51
290×950×950 290×950×950 353×950×950 353×950×950 353×950×950
S-106MU1E51 S-140MU1E51 S-160MU1E51
5.6
19,100
6.3
21,500
33 30 28 50 47 45
16.0
54,600
18.0
61,400
46 40 38 63 56 53
S-60MU1E51
6.0
20,500
7.1
24,200
36 32 29 53 49 46
28
148
Page 15
SPECIFICATIONS
Low Silhouette Ducted (F2 type)
Model Name Power Source
Cooling Capacity
Heating Capacity
Sound Pressure Level
Sound Power Level
Unit Dimensions (H×W×D) Net Weight
Model Name Power Source
Cooling Capacity
Heating Capacity
Sound Pressure Level
Sound Power Level
Unit Dimensions (H×W×D) Net Weight
High Medium Low High Medium Low
High Medium Low High Medium Low
BTU/h
BTU/h
dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)
BTU/h
BTU/h
dB(A) dB(A) dB(A) dB(A) dB(A) dB(A)
S-22MF2E5 S-28MF2E5 S-36MF2E5 S-45MF2E5 S-56MF2E5
220 - 230 - 240 V, single-phase, 50 Hz
kW
kW
mm
kg 29 29 29 29 29
kW
kW
mm
kg 34 34 46 46 46
2.2 2.8 3.6 4.5
7,500 9,600 12,300 15,400
2.5 3.2 4.2 5.0
8,500 10,900 14,300 17,100
33 33 33 34 29 29 29 32 25 25 25 28 55 55 55 56 51 51 51 54 47 47 47 50
290×800×700 290×800×700 290×800×700 290×800×700 290×800×700 290×1,000×700
S-73MF2E5 S-90MF2E5 S-106MF2E5 S-140MF2E5 S-160MF2E5
220 - 230 - 240 V, single-phase, 50 Hz
7.3 9.0 10.6 14.0
24,900 30,700 36,200 47,800
8.0 10.0 11.4 16.0
27,300 34,100 38,900 54,600
35 37 38 39 32 34 34 35 26 28 31 32 57 59 60 61 54 56 56 57 48 50 53 54
290×1,000×700 290×1,000×700 290×1,400×700 290×1,400×700 290×1,400×700
5.6
19,100
6.3
21,500
34 32 28 56 54 50
16.0
54,600
18.0
61,400
40 36 33 62 58 55
S-60MF2E5
6.0
20,500
7.1
24,200
35 32 26 57 54 48
34
149
Page 16
SPECIFICATIONS
Mini (LE1 type) (Single-phase)
Model Name Power Source
Cooling Capacity
Heating Capacity
Sound Pressure Level (C/H) Sound Power Level (C/H) dB(A) Unit Dimensions (H×W×D) Net Weight
Mini (LE1 type) (3-phase)
Model Name Power Source
Cooling Capacity
Heating Capacity
Sound Pressure Level (C/H) Sound Power Level (C/H) dB(A) Unit Dimensions (H×W×D) Net Weight
kW
BTU/h
kW
BTU/h
dB(A)
mm
kg
kW
BTU/h
kW
BTU/h
dB(A)
mm
kg
U-4LE1E5 U-5LE1E5 U-6LE1E5
220 - 230 - 240 V, single-phase, 50 Hz
12.1 14.0 15.5
41,300 47,800 52,900
12.5 16.0 18.0
42,700 54,600 61,400
50/52 51/53 52/55 68/70 69/71 70/73
1330×940×340
104
U-4LE1E8 U-5LE1E8 U-6LE1E8
380 - 400 - 415 V, 3-phase, 50 Hz
12.1 14.0 15.5
41,300 47,800 52,900
12.5 16.0 18.0
42,700 54,600 61,400
50/52 51/53 52/55 68/70 69/71 70/73
103
104 104
1330×940×340
103 103
150
Page 17
SPECIFICATIONS
2WAY (ME1 type)
Model Name U-8ME1E81 U-10ME1E81 U-12ME1E81 U-14ME1E81 U-16ME1E81
Power Source
Cooling Capacity
Heating Capacity
Sound Pressure Level Sound Power Level dB(A) Unit Dimensions (H×W×D) Net Weight
Model Name U-18ME1E81 U-20ME1E81
Power Source
Cooling Capacity
Heating Capacity
Sound Pressure Level Sound Power Level dB(A) Unit Dimensions (H×W×D) Net Weight
kW
BTU/h
kW
BTU/h
dB(A)
mm
kg 234 234 281 309 309
kW
BTU/h
kW
BTU/h
dB(A)
mm
kg 421 421
22.4 28.0 33.5 40.0
76,500 95,600 114,300 136,500
25.0 31.5 37.5 45.0
85,300 107,500 128,000 153,600
56.5 59.0
71.0
1758×770×930
380 - 400 - 415 V,
3-phase, 50 Hz
50.0 56.0
170,600 191,100
56.0 63.0
191,100 215,000
60.0 63.0
74.5 77.5
1758×1540×930
380 - 400 - 415 V, 3-phase, 50 Hz
45.0
153,600
50.0
170,600
61.0 62.0
73.5
1758×770×930 1758×770×930 1758×1000×930 1758×1000×930
1758×1540×930
75.5 76.5 76.5
62.0
151
Page 18
SPECIFICATIONS
2WAY (ME1 type) Standard-COP mode
Model Name
Power Source
Cooling Capacity
Heating Capacity
Sound Pressure Level Sound Power Level dB(A) Unit Dimensions (H×W×D) Net Weight
Model Name
Power Source
Cooling Capacity
Heating Capacity
Sound Pressure Level Sound Power Level dB(A) Unit Dimensions (H×W×D) Net Weight
* Outdoor unit model name ended with letters "E8E" is salt-air damage resistant specifications.
U-8ME1E8 U-8ME1E8E
380 - 400 - 415 V,
3-phase,
50/60 Hz
kW
BTU/h
kW
BTU/h
dB(A)
mm
kg 230 281 281 307 307
kW
BTU/h
kW
BTU/h
dB(A)
mm
kg 423 423
22.4 28.0 33.5 40.0
76,500 95,600 114,300 136,500
25.0 31.5 37.5 45.0
85,300 107,500 128,000 153,600
56.5 59.0
71.0
1758×770×930
U-18ME1E8 U-20ME1E8 U-18ME1E8E U-20ME1E8E
380 - 400 - 415 V,
50.0 56.0
170,600 191,100
56.0 63.0
191,100 215,000
60.0 63.0
74.5 77.5
1758×1540×930
U-10ME1E8 U-12ME1E8 U-14ME1E8 U-16ME1E8 U-10ME1E8E U-12ME1E8E U-14ME1E8E U-16ME1E8E
380 - 400 - 415 V, 3-phase, 50 Hz
61.0 62.0
73.5
1758×770×930 1758×770×930 1758×1000×930 1758×1000×930
3-phase, 50 Hz
1758×1540×930
75.5 76.5 76.5
45.0
153,600
50.0
170,600
62.0
2WAY (ME1 type) High-COP mode
Model Name
Power Source
Cooling Capacity
Heating Capacity
Sound Pressure Level Sound Power Level dB(A) Unit Dimensions (H×W×D) Net Weight
* Outdoor unit model name ended with letters "E8E" is salt-air damage resistant specifications.
U-8ME1E8 U-8ME1E8E U-14ME1E8E U-16ME1E8E U-18ME1E8E U-20ME1E8E
380 - 400 - 415 V,
3-phase,
50/60 Hz
kW
BTU/h
kW
BTU/h
dB(A)
mm
kg 230
22.4
76,500
25.0
85,300
56.5
71.0 72.0 72.0
1758×770×930
U-14ME1E8
28.0
95,600
31.5
107,500
60.0
1758×1000×930
307
U-16ME1E8
380 - 400 - 415 V, 3-phase, 50 Hz
33.5
114,300
37.5
128,000
60.0
1758×1000×930
307
152
U-18ME1E8 U-20ME1E8
40.0 45.0
136,500 153,600
45.0 50.0
153,600 170,600
59.0 60.0
75.0 76.0
1758×1540×930
423 423
1758×1540×930
Page 19
SPECIFICATIONS
3WAY (MF1 type)
Model Name Power Source
Cooling Capacity
Heating Capacity
Sound Pressure Level Sound Power Level dB(A) Unit Dimensions (H×W×D) Net Weight
kW
BTU/h
kW
BTU/h
dB(A)
mm
kg
U-8MF1E8 U-10MF1E8 U-12MF1E8 U-14MF1E8 U-16MF1E8
380 - 400 - 415 V, 3-phase, 50 Hz
22.4 28.0 33.5 40.0
76,400 95,500 114,300 136,500
25.0 31.5 37.5 45.0
85,300 107,500 128,000 153,600
54.7 55.3 56.3 60.3
68.4 69.0 70.0 74.0 73.7 188890×(890(Ceiling dimension)(+60))
290
290 290 340 340
45.0
153,600
50.0
170,600
60.5
153
Page 20
SPECIFICATIONS
CARACTÉRISTIQUES / ESPECIFICACIONES / TECHNISCHE DATEN / SPECIFICHE / SPECIFICATIE / ESPECIFICAÇÕES
EnglishFrançais Español Deutsch
4-Way Cassette (U1 type) Cassette 4 voies (Type U1) Cassette de 4 vías (tipo U1) 4-Weg Kassette (Typ U1) Ceiling (T1 type) Plafond (Type T1) Techo (tipo T1) Deckenmontage (Typ T1) High Static Pressure Ducted (E1
type) 4-Way Cassette 60x60 (Y1 type) Cassette 4 voies 60x60 (Type Y1) Cassette de 4 vías 60x60 (tipo Y1) 4-Weg Kassette 60 x 60 (Typ Y1) Slim Low Static Ducted (M1 type) Conduit Mince Faible S
Low Silhouette Ducted (F2 type) Conduit Silhouette Basse
2-Way Cassette (L1 type) Cassette 2 voies (Type L1) Cassette de 2 vías (tipo L1) 2-Weg Kassette (Typ L1)
assette (D1 type) Cassette 1 voie (Type D1) Cassette de 1 vía (tipo D1) 1-Weg Kassette (Typ D1)
1-Way C Floor Standing (P1 type) Vertical au sol (Type P1) De pie (tipo P1) Bodenaufstellung (Typ P1) Concealed Floor Standing
(R1 type) Wall Mounted (K1 type) Monté au mur (Type K1) Montado en pared (tipo K1) Wandmontage (Typ K1) Standard-COP mode Mode COP standard Modo COP estándarCOP-Modus Standard High-COP mode Mode COP élevé Modo COP alto COP-Modus hoch Mini (LE1 type) Mini (Type LE1) Mini (tipo LE1) Mini (Typ LE1) 2WAY(ME1 type) 2WAY (Type ME1) 2WAY (tipo ME1) 2WAY (Typ ME1) 3WAY(MF1 type) 3WAY (Type MF1) 3WAY (tipo MF1) 3WAY (Typ MF1)
Conduit Haute Pression Statique (Type E1)
(Type M1)
(Type F2)
Ver ti cal au sol caché (Type R1) De pie y oculto (tipo R1) Bodenaufstellung/Einbau (Typ R1)
tatique
Conductos de presión estática alta (tipo E1)
Conductos finos de presión estática baja (tipo M1)
Conductos de silueta baja (tipo F2)
Kanalgerät mit hoher statischer Pressung (Typ E1)
Flaches Kanalgerät mit niedriger statischer Pressung (M1)
Kanalgerät, flache Bauform (Typ F2)
English Italiano Nederlands Portugs
4-Way Cassette (U1 type) A cassetta a 4 vie (tipo U1) 4-weg cassette (type U1) Cassete de 4 vias (Tipo U1) Ceiling (T1 type) A soffitto (tipo T1) Plafond (type T1) Tecto (Tipo T1) High Static Pressure Ducted
(E1 type) 4-Way Cassette 60x60 (Y1 type) A cassetta a 4 vie 60x60 (tipo Y1) 4-weg cassette 60x60 (type Y1) Cassete de 4 vias 60x60 (Tipo Y1) Slim Low Static Ducted (M1 type) S
Low Silhouette Ducted (F2 type) A profilo basso a condotto
2-Way Cassette (L1 type) A cassetta a 2 vie (tipo L1) 2-weg cassette (type L1) Cassete de 2 vias (Tipo L1) 1-Way Cassette (D1 type) A cassetta Floor Standing (P1 type) A pavimento (tipo P1) Vloermodel (type P1) Montagem no chão (Tipo P1) Concealed Floor Standing
(R1 type) Wall Mounted (K1 type) Con montaggio a parete (tipo K1) Wandmodel (K1) Montagem na parede (Tipo K1) Standard-COP mode Modalità COP standard Standaa rd-COP-modus Modo COP padrão High-COP mode Modalità COP alta Hoge-COP-modus Modo COP alto Mini (LE1 type) Mini (tipo LE1) Mini (type LE1) Mini (Tipo LE1) 2WAY(ME1 type) 2WAY (tipo ME1) 2WAY (type ME1) 2WAY (Tipo ME1) 3WAY(MF1 type) 3WAY (tipo MF1) 3
A condotto ad alta pressione statica (tipo E1)
ottile a condotto a bassa
pressione statica (tipo M1)
(tipo F2)
a 1 via (tipo D1) 1-weg cassette (type D1) Cassete de 1 via (Tipo D1)
A pavimento nascosto (tipo R1) Verborgen vloermodel (type R1) Montagem no chão oculta
Kanaalmodel met hoge statische druk (type E1)
Slank laag statisch kanaalmodel (type M1)
Kanaalmodel met onopvallend silhouet (type F2)
WAY (type MF1) 3WAY (Tipo MF1)
Pressão estática elevada no tubo (Tipo E1)
Estática baixa fina no tubo (Tipo M1)
Baixo perfil no tubo (Tipo F2)
(Tipo R1)
154
Page 21
SPECIFICATIONS
CARACTÉRISTIQUES / ESPECIFICACIONES / TECHNISCHE DATEN / SPECIFICHE / SPECIFICATIE / ESPECIFICAÇÕES
EnglishFrançais Español Deutsch
Model Name Nom du modèle Nombre del modelo Modellbezeichnung Power Source Source d'alimentation Fuente de alimentación Spannungsquelle Cooling Capacity Ca pacité de refroidissement Capacidad de refrigeración Kühlleistung Heating Capacity Capacité de chauffage Capacidad de calefacción Heizleistung Sound Pressure Level (High/
Medium/Low) Sound Power Level (High/
Medium/Low) Unit Dimensions (HxWxD; mm) Dimensions d'unité (HxLxP ; mm) Dimensiones de la unidad (Alto x
(HxWxD: ceiling dimension) (HxLxP : dimensions plafond) (Alto x Largo x Ancho: dimensión
Net Weight (kg) Poids net (kg) Peso neto (kg) Nettogewicht (kg) Outdoor unit model name ended
with letters “E8E” is salt-air damage resistant specifications.
Niveau de press Moyen/Bas)
Niveau de puissance sonore (Haut/Moyen/Bas)
Les noms de modèle d'unité extérieure se terminant par les lettres « E8E » sont des spécifications de résistance aux dommage marin.
ion sonore (Haut/
s provoqués par l'air
Nivel de presión acústica (alto/ medio/bajo)
Nivel de potencia acústica (alto/ medio/bajo)
Largo x Ancho; mm)
del techo)
El nombre del modelo de la unidad exterior termina con los caracteres “E8E” para indicar sus especificaciones de resistencia al
aire salado.
Schalldruckpegel (hoch/mittel/
niedrig) Schallleistungspegel (hoch/mittel/
niedrig)
bmessungen (H x B x T
Gerätea [mm])
(H x B x T: Deckenmaß)
Die Außeneinheit, deren Modelbezeichnung auf „E8E“ endet, ist laut Spezifikation salzluftbeständig.
English Italiano Nederlands Portugs
Model Name Modello Modelnaam Nome do modelo Power Source Fonte di alimentazione Voeding Fonte de alimentação Cooling Capacity Ca pacità di raffreddamento Koelingscapaciteit Capacida de de arrefecimento Heating Capacity Capacità di riscaldamento Verwarmingscapaciteit Ca pacidade de aquecimento Sound Pressure Level (High/
Medium/Low) Sound Power Level (High/
Medium/Low) Unit Dimensions (HxWxD; mm) Dimensioni unità (AxLxP; mm) Afmetingen van de unit (H x B x D;
(HxWxD: ceiling dimension) (AxLxP: dimensione s Net Weight (kg) Peso netto (kg) Nettogewicht (kg) Peso líquido (kg) Outdoor unit model name ended
with letters “E8E” is salt-air damage resistant specifications.
Livello di pressione acustica (alto/
asso)
medio/b Livello di potenza acustica (alto/
medio/basso)
offitto) (H x B x D: plafondafmeting) (AxLxP: dimensão do tecto)
I nomi dei modelli di unità esterne che terminano con i caratteri “E8E” indicano caratteristiche tecniche di resistenza al danneggiamento da salsedine.
Geluidsdrukniveau (hoog/ normaal/laag)
Geluidsvermogenniveau (hoog/ normaal/laag)
mm)
Als de modelnaam van de buitenunit eindigt op "E8E", voldoet het model specificaties voor producten die resistent zijn tegen schade door zoute lucht.
aan de
Nível da pressão do som (Alto/ Médio/Baixo)
Nível da potência de som (Alto/ Médio/Baixo)
Dimensões da unidade (AxLxP; mm)
O nome do modelo da unidade exterior terminado pelas letras “E8E” é a especificação de resistência aos danos do ar salgado.
155
Page 22
SPECIFICATIONS
ΠΡΟΔΙΑΓΡΑΦΕΣ / СПЕЦИФИКАЦИИ / ТЕХНИЧЕСКИЕ ХАРАКТЕРИСТИКИ / СПЕЦИФІКАЦІА
English Ελληνικη Български Русский Українська
4-Way Cassette (U1 type) Κασέτας 4-δρομο (Τύπ ος
Ceiling (T1 type) Οροφής (Τύ πο ς T1) Таванен (тип Т1) Потолочный (Тип T1) Стельовий (тип T1) High Static Pressure
Ducted (E1 type)
4-Way Cassette 60x60 (Y1 type)
Slim Low Static Ducted (M1 type)
Low Silhouette Ducted (F2 type)
2-Way Cassette (L1 type) Κασέτας 2-δρομο (Τύπ ο ς
1-Way Cassette (D1 type) Κασέτας 1-δρομο (Τύπ ος
Floor Standing (P1 type) Όρθιο δαπέδου (Τύ πο ς
Concealed Floor Standing (R1 type)
Wall Mounted (K1 type) Επιτοίχιο (Τύ π ος K1) Standard-COP mode Λειτουργία τυπικού COP Режим със стандартен
High-COP mode Λειτουργία υψηλού COP Mini (LE1 type) Mini (Τύπο ς LE1) Mini (тип LE1) Mini (тип LE1) Mini (тип LE1) 2WAY (ME1 type) 2WAY (Τύπο ς ME1) 2WAY (тип ME1) 2WAY (тип ME1) 2WAY (ME1)
3WAY (MF1 type) 3WAY (Τύπ ος MF1) 3WAY (тип MF1) 3WAY (тип MF1) 3WAY (MF1)
U1)
Αγωγός υ ψηλής στατικής πίεσης (Τύπ ο ς E1)
Κασέτας 4-δρομο 60x60 (Τύπ ο ς Y1)
Αγωγός χα μηλής στατικής πίεσης λεπτού τύπου (Τύπ ο ς M1)
Χαμηλής σιλουέτας με αγωγό (Τύπ ο ς F2)
L1)
D1)
P1)
Εντοιχισμένο όρθιο δαπέδου (Τύπ ο ς R1)
4-пътен касетен (тип U1) Кассетный с 4
Високонапорен канален (тип Е1)
4-пътен касетен 60х60 (тип Y1)
Тънък нисконапорен канален (тип М1)
Канален с нисък силует (тип F2)
2-пътен касетен (тип L1) Кассетный с 2
1-пътен касетен (тип D1) Кассетный с 1
Подов колонен (тип P1) Напольный (Тип P1) Підлоговий (тип P1)
Скрит подов колонен (тип R1)
Стенен (тип К1) Настенный (тип K1) Настінний (тип K1)
COP (КПД) Режим с висок COP (КПД)
направлениями потока (тип U1)
Скрытый с высоким статическим давлением (тип E1)
Кассетный с 4 направлениями потока 60x60 (тип Y1)
Скрытый тонкий с низким статическим давлением (тип M1)
Скрытый плоский (тип F2)
направлениями потока (тип L1)
направлением потока (тип D1)
Скрытый напольный (Тип R1)
Стандартный COP режим
Высокий COP режим Режим високого ККД
4-канальний касетний (тип U1)
Із каналом під високим статичним тиском (тип E1)
4-канальний касетний 60x60 (тип Y1)
Тонкий, із каналом під низьким статичним тиском (тип M1)
Із каналом з низького профілю (тип F2)
2-канальний касетний (тип L1)
1-канальний касетний (тип D1)
Прихований підлоговий (тип R1)
Режим стандартного ККД
English Ελληνικη Български Русский Українська
Model Name Όνομα μοντέλου Наименование на модел Название модели Назва моделі Power Source Πηγή ισχύος Захранване Источник питания Джерело живлення Cooling Capacity Δυνατότητα ψύξης Охлаждаща мощност Мощность охлаждения Охолоджувальна
Heating Capacity Δυνα τότητα θέρμανσης Отоплителна мощност Мощность обогрева Нагрівальна здатність Sound Pressure Level
(High/Medium/Low)
Sound Power Level (High/ Medium/Low)
Unit Dimensions (HxWxD; mm)
(HxWxD: ceiling dimension) Net Weight (kg) Καθαρ ό βάρος (kg) Нетно тегло (кг) Вес нетто (кг) Вага нетто (кг) Outdoor unit model name
ended with letters “E8E” is
salt-air damage resistant specifications.
Επίπεδο πίεσης ήχου (Υψηλό/Μεσαίο/Χαμηλό)
Επίπεδο ισχύος ήχου (Υψηλό/Μεσαίο/Χαμηλό)
μονάδας
Διαστάσεις
(ΥxΠxΒ, mm)
(ΥxΠxΒ: διαστάσεις οροφής)
Το μοντέλο εξωτερικής μονάδας του οποίου η ονομασία τελειώνει με τους χαρακ τήρες “E8E” είναι ανθεκτικό στην πρόκληση βλάβης από αέρα που περιέχει αλάτι.
Ниво на звуково налягане
Ниво на сила на звука Уровень звуковой
Размери на модула (ВхШхД, мм)
ВхШхД: размери на тавана)
Външните тела с наименования на модела, завършващи на „E8E”, са устойчиви на вредните въздействия на солен въздух.
Уровень звукового давления (Высокий/ Средний/Низкий)
мощности (Высокий/ Средний/Низкий)
Размеры аппарата (ВxШxГ; мм)
(ВxШxГ: размеры потолка) (ВxШxГ: розмір стелі)
Название модели внешнего блока, оканчивающееся буквами “E8E”, представляет собой устойчивый к соленому воздуху вариант.
156
здатність
Рівень звукового тиску (високий/середній/ низький)
Рівень потужності звуку (високий/середній/ низький)
Розміри пристрою (ВxШxГ; мм)
Якщо назва моделі зовнішнього пристрою закінчується буквами «E8E», це означає, що модель стійка до дії солоного повітря.
Page 23
SPECIFICATIONS
SPESIFIKASI
English B.INDONESIA
4-Way Cassette (U1 type) Kaset 4 Arah (Tipe U1) Ceiling (T1 type) Langit-Langit (Tipe T1) High Static Pressure Ducted
(E1 type) 4-Way Cassette 60x60 (Y1 type) Kaset 4 Arah 60x60 (Tipe Y1) Slim Low Static Ducted (M1 type) Pipa Statis Rendah dan Tipis
Low Silhouette Ducted (F2 type) Pipa Siluet Rendah (Tipe F2) 2-Way Cassette (L1 type) Kaset 2 Arah (Tipe L1) 1-Way Cassette (D1 type) Kaset 1 Ar Floor Standing (P1 type) Berdiri (Tipe P1) Concealed Floor Standing
(R1 type) Wall Mounted (K1 type) Pemas angan di Dinding (Tipe K1) Standard-COP mode Mode COP Standar High-COP mode Mode COP Tinggi Mini (LE1 type) Mini (Tipe LE1) 2WAY (ME1 type) 2WAY (Tipe ME1) 3WAY (MF1 type) 3WAY (Tipe MF1)
Pipa Bertekanan Statis Tinggi (Tipe E1)
(Tipe M1)
ah (Tipe D1)
Berdiri dan Tersembunyi (Tipe R1)
English B.INDONESIA
Model Name Nama Model Power Source Catu Daya Cooling Capacity Ka pasitas Pendinginan Heating Capacity Kapasitas Pemanasan Sound Pressure Level
(High/Medium/Low) Sound Power Level
(High/Medium/Low) Unit Dimensions (HxWxD; mm) Dimensi Unit (PxLxT; mm) (HxWxD:ceiling dimension) (PxLxT:dimensi langit-langit) Net Weight (kg) Berat Bersih (kg) Outdoor unit model name ended
with letters “E8E” is salt-air damage resistant specifications.
Tingkat Tekanan Suara (Tinggi/Sedang/Rendah)
Tingkat Daya Suara (Tinggi/Sedang/Rendah)
Nama model unit outdoor yang berakhir dengan huruf “E8E” memiliki spesifikasi antikerusakan akibat air asin.
157
Page 24
English
Français
Español
Deutsch
Italiano
Nederlands
Portugs
Eλληνικά
Български
Русский
Українська
Compliance with regulation 842/EC/2006 Article 7(1) requirements
DO NOT VENT R410A INTO THE ATMOSPHERE: R410A IS A FLUORINATED GREENHOUSE GAS, COVERED BY THE KYOTO PROTOCOL, WITH A GLOBAL WARMING POTENTIAL (GWP) = 1975.
Conformité aux exigences de l’article 7 (1) de la réglementation 842/EC/ 2006
NE PAS METTRE LE R410A À L’AIR LIBRE: LE R410A EST UN GAZ À EFFET DE SERRE FLUORÉ, RÉGULÉ PAR LE PROTOCOLE DE KYOTO AVEC UN POTENTIEL DE RÉCHAUFFEMENT DE LA PLANÈTE (GWP) = 1975.
Cumplimiento de los requisitos del Artículo 7 (1) de la Directiva 842/EC/ 2006
NO LIBERAR R410A AL AIRE LIBRE: EL R410A ES UN GAS FLUORIZADO DE EFECTOS DE INVERNADERO, INCLUIDO EN EL PROTOCOLO DE KYOTO, CON UN POTENCIAL DE CALENTAMIENTO GLOBAL (GWP) = 1975.
Kompatibilität mit den Anforderungen der Vorschrift 842/EC/2006, Artikel 7 (1)
R410A NICHT IN DIE AUSSENLUFT ABLASSEN: R410A IST EIN FLUORIERTES TREIBHAUSGAS, DAS IM KYOTO-PROTOKOLL ENTHALTEN IST UND EIN ERDERWÄRMUNGSPOTENTIAL (GWP) VON 1975 AUFWEIST.
Osservanza delle richieste dell’Articolo 7(1) delle regolamentazioni 842/ EC/2006
NON DISPERDERE R410A NELL’ATMOSFERA: L’R410A È UN GAS FLUORATO CAUSA DI EFFETTO SERRA E COPERTO DAL PROTOCOLLO DI KYOTO CON UN POTENZIALE DI RISCALDAMENTO GLOBALE (GWP) = 1975.
Voldoet aan de eisen van regeling 842/EC/2006 artikel 7(1)
LAAT R410A NIET ONSNAPPEN IN DE DAMPKRING: R410A IS EEN FLUORHOUDEND BROEIKASGAS ZOALS BEDOELD IN HET KYOTO PROTOCOL, MET EEN AARDOPWARMINGSVERMOGEN (GWP) = 1975.
Conformidade com o regulamento 842/EC/2006 Requisitos do Artigo 7(1)
NÃO DEIXE O R410A ESC APA R PAR A A AT MO SFERA: O R410A É UM GÁS FLUORADO COM EFEITO DE ESTUFA, REGULADO PELO PROTOCOLO DE QUIOTO, COM UM POTENCIAL DE AQUECIMENTO GLOBAL (GWP) = 1975.
Συμμόρφωση με τις απαιτήσεις του κανονισμού 842/EC/2006 Άρθρο 7(1)
ΜΗΝ ΑΠΕΛΕΥΘΕΡΩΣΕΤΕ ΤΟ R410A ΣΤΗΝ ΑΤΜΟΣΦΑ ΙΡΑ : ΤΟ R410A ΕΙΝΑΙ ΦΘΟΡΙΟΥΧΟ ΑΕΡΙΟ ΘΕΡΜΟΚΗΠΙΟΥ ΠΟΥ ΚΑΛΥΠΤΕΤΑΙ ΑΠΟ ΤΟ ΠΡΩΤΟΚΟΛΛΟ ΤΟΥ ΚYΟΤΟ, ΜΕ ΔΥΝ Α Μ Ι ΚΟ ΠΛΑΝΗΤΙΚΗΣ ΑΥΞΗΣΗΣ ΘΕΡΜΟΚΡΑΣΙΑΣ (GWP) = 1975.
Съответствие с изискванията на 842/EC/2006 член 7(1)
НЕ ИЗПУСКТАЙТЕ R410A В АТМОСФЕРАТА: R410A Е ПАРНИКОВ ГАЗ, СЪДЪРЖАЩ ФЛУОР, ВКЛЮЧЕН В ПРОТОКОЛА ОТ КИОТО С ПОТЕНЦИАЛ ЗА ГЛОБАЛНО ЗАТОПЛЯНЕ (GWP) = 1975.
Соответствие требованиям Статьи 7(1) правил 842/EC/2006
НЕ ДОПУСКАЙТЕ ВЫБРОСОВ R410A В АТМОСФЕРУ: R410A ЯВЛЯЕТСЯ ФТОРИРОВАННЫМ ПАРНИКОВЫМ ГАЗОМ, ОХВАТЫВАЕМЫМ КИОТСКИМ ПРОТОКОЛОМ, С ПОТЕНЦИАЛОМ ГЛОБАЛЬНОГО ПОТЕПЛЕНИЯ (GWP) = 1975.
Згідно норм 842/EC/2006 стаття 7(1)
НЕ ВИПУСКАЙТЕ R410A В АТМОСФЕРУ: R410A - ФТОРОВМІСНИЙ ПАРНИКОВИЙ ГАЗ, ЩО ПІДПАДАЄ ПІД ДІЮ КІОТСЬКОГО ПРОТОКОЛУ, З ПОТЕНЦІАЛОМ ГЛОБАЛЬНОГО ПОТЕПЛІННЯ (GWP) = 1975.
ΤΗΣ
159
Page 25
Authorized representative in EU Panasonic Testing Centre Panasonic Marketing Europe GmbH Winsbergring 15, 22525 Hamburg, Germany
BE0312-0