Timers
Possible to set and change the time with front digit switches easily during the power off. Furthermore single unit has a time range of 0.01s to 9990hrs!!
FEATURES
1. Possible to set and change the time and the time range even when the power is off.
2. Selectable 8 different time ranges with front digit switches.
3. [QM4H-S Type] It can select the mode with MODE switch. T.D. MODE: Time delay 2C (2 Form C)
(with MODE switch)
INST. MODE: Time delay 1C (1 Form C)
Instantaneous 1C (1 Form C) [QM4H-G Type] Reset and stop signal input enable to external control.
G Type
PRODUCT TYPES
Product name
S Type QM4H
digital timer
G Type QM4H
digital timer
Note: Time delay directional subtraction types are also available by order
Time delay
direction
Addition
Time range Operating mode Contact arrangement Operating voltage Part number
Power ON delay
0.01s/0.1s/1s/0.1min/ 1min/0.1h/1h/10h
(8 time ranges)
Power ON delay
(with reset and stop terminals)
PART NAMES
QM4H-S
-+-
888S
+--+
+
Elapsed time display
Time delay indicator
(OP.LED)
Time range switch
MODE switch
(QM4H-S type only)
Set time display
Time setting switch
(3 digits)
TIMER
MODE
T.D.
INST.
T.D. mode: Time delay 2C INST. mode: Time delay 1C and Instantaneous 1C (Use MODE switch on front)
Time delay 1C
Protective construction:
QM4H: IP40 with cover AQM4801: IP50 with cover AQM4803: IP64
12 to 48 V AC/DC QM4HS-U2C-48V
100 to 240 V AC/DC QM4HS-U2C-240V
12 to 48 V AC/DC QM4HG-U1C-48V
100 to 240 V AC/DC QM4HG-U1C-240V
44
TIME RANGE SETTINGS
07/2004
QM4H
Time range switch
Operating time range
.01
S
Note that there are two settings with the same range.
0.1 S
.01
S
0.01s to
9.99s
0.1 S
0.1s to
99.9s
.01S0.1
SMH
1s
to
999s
S
0.1 M
to
0.1
1min.
to
999min
M
0.1min.
99.9min
SMH
0.1 H
0.1 H
0.1h to
99.9h
1h to
999h
10
H
10
H
10h
to
9990h
SPECIFICATIONS
Item
Type
Rated operating voltage 12 to 48 V AC/DC and 100 to 240 V AC/DC
During time delay
After time delay
During time delay
After time
Rating
12 to 48 V
AC/DC
Rated power consumption
100 to 240 V
AC/DC
delay
Rated frequency 50/60 Hz common (at AC)
Rated control capacity 5 A, 250V AC (resistive load)
Time range 0.01s to 9990h, Selection of 8 range: 0.01s/0.1s/1s/0.1min/1min/0.1h/1h/10h
Operation mode Power ON delay Power ON delay (with reset and stop terminals)
Min. input signal width 20ms (Reset and Stop inputs)*
Operating time fluctuation ±(0.01%+0.05s) in case of power on start
Time accuracy*
Temperature error
1
Setting error
Voltage error
T.D. mode: Time delay 2C
Contact
Contact arrangement
INST. mode: Time delay 1C and Instantaneous 1C (Use MODE switch on front)
Contact material Silver alloy
Life*
3
Mechanical (contact) Min. 10
Electrical (contact) Min. 105 (at rated control vltage)
Allowable operating voltage range 85 to 110% of rated operating voltage
Breakdown voltage (Initial value)
Electrical
Insulation resistance (Initial value)
Reset time Max. 0.1s
Functional 10 to 55 Hz: 1 cycle/min. single amplitude of 0.25 mm .010 inch (10 min on 3 axes)
Destructive 10 to 55 Hz: 1 cycle/min. single amplitude of 0.375 mm .015 inch (1h on 3 axes)
Functional 98 m/s2 (4 times on 3 axes)
Destructive 980 m/s2 (5 times on 3 axes)
Mechanical
Operating conditions
Vibration resistance
Shock resistance
Ambient temperature –10°C to 55°C +14°F to +131°F
Ambient humidity Max. 85% RH (non-condensing)
Air pressure 860 to 1060 hPa
Mass (Weight) Approx. 130 g 4.59 oz Approx. 120 g 4.23 oz
Others
Available standards UL, C-UL, CE
Operating display LED (red), During time delay: blinking, After time delay: OFF
Notes: 1. Unspecified measuring conditions are rated operating voltage (in case of DC type, ripple rate of 5% or less), ambient temp. 20°C 68°F,
and stop time 1 second.
2. Reset start applies to QM4H-G type.
3. Excluding switches
4. Note that if the QM4H-G type is set to zero “0” and a STOP signal is input, output will begin when the power is turned on.
QM4H-S QM4H-G
12 V DC, 48 V DC: Max. 1.5W 12 V AC, 48 V AC: Max. 3.0 VA
12 V DC, 48 V DC: Max. 2.5W 12 V AC, 48 V AC: Max. 5.0 VA
100 V DC, 240 V DC: Max. 1.5W 100 V AC, 240 V AC: Max. 3.0 VA
100 V DC, 240 V DC: Max. 2.0W 100 V AC, 240 V AC: Max. 4.0 VA
±(0.005%+0.03s) in case of input reset start*
During time delay
After time delay
During time delay
After time delay
12 V DC, 48 V DC: Max. 1.0W 12 V AC, 48 V AC: Max. 2.0 VA
12 V DC, 48 V DC: Max. 1.5W 12 V AC, 48 V AC: Max. 3.5 VA
100 V DC, 240 V DC: Max. 1.0W 100 V AC, 240 V AC: Max. 2.5 VA
100 V DC, 240 V DC: Max. 1.8W 100 V AC, 240 V AC: Max. 3.2 VA
2
Operating voltage: 85 to 110% V Temperature: –10 to +55°C +14 to 131°F (20°C 68°F) Stopped time: 0.1 sec to 1 hour
Time delay 1C
7
Between live and dead metal parts, between input and output,
between contact sets, between contacts
Min. 100 M (at 500 V DC megger)
Between live and dead metal parts: 2, 000 Vrms for 1 min Between input and output: 2, 000 Vrms for 1 min Between contact sets: 2, 000 Vrms for 1 min Between contacts: 1, 000 Vrms for 1 min
4