DIN 48 SIZE
QM4H
DIGITAL TIMER
Timers
Possible to set and change the time with front digit switches easily
during the power off.
Furthermore single unit has a time range of 0.01s to 9990hrs!!
FEATURES
1. Possible to set and change the time and
the time range even when the power is off.
2. Selectable 8 different time ranges with
front digit switches.
3. [QM4H-S Type]
It can select the mode with MODE switch.
T.D. MODE: Time delay 2C (2 Form C)
S Type
(with MODE switch)
INST. MODE: Time delay 1C (1 Form C)
Instantaneous 1C (1 Form C)
[QM4H-G Type]
Reset and stop signal input enable to
external control.
G Type
PRODUCT TYPES
Product name
S Type QM4H
digital timer
G Type QM4H
digital timer
Note: Time delay directional subtraction types are also available by order
Time delay
direction
Addition
Time range Operating mode Contact arrangement Operating voltage Part number
Power ON delay
0.01s/0.1s/1s/0.1min/
1min/0.1h/1h/10h
(8 time ranges)
Power ON delay
(with reset and
stop terminals)
PART NAMES
QM4H-S
-+-
888S
+--+
+
Elapsed time display
Time delay indicator
(OP.LED)
Time range switch
MODE switch
(QM4H-S type only)
Set time display
Time setting switch
(3 digits)
TIMER
MODE
T.D.
INST.
T.D. mode: Time delay 2C
INST. mode: Time delay 1C
and Instantaneous 1C
(Use MODE switch on front)
Time delay 1C
Protective construction:
QM4H: IP40
with cover AQM4801: IP50
with cover AQM4803: IP64
12 to 48 V AC/DC QM4HS-U2C-48V
100 to 240 V AC/DC QM4HS-U2C-240V
12 to 48 V AC/DC QM4HG-U1C-48V
100 to 240 V AC/DC QM4HG-U1C-240V
44
TIME RANGE SETTINGS
QM4H
Time range
switch
Operating
time range
.01
S
Note that there are two settings with the same range.
0.1
S
.01
S
0.01s
to
9.99s
0.1
S
0.1s
to
99.9s
.01S0.1
SMH
1s
to
999s
S
0.1
M
to
0.1
1min.
to
999min
M
0.1min.
99.9min
SMH
0.1
H
0.1
H
0.1h
to
99.9h
1h
to
999h
10
H
10
H
10h
to
9990h
SPECIFICATIONS
Item
Type
Rated operating voltage 12 to 48 V AC/DC and 100 to 240 V AC/DC
During time
delay
After time
delay
During time
delay
After time
Rating
12 to 48 V
AC/DC
Rated power
consumption
100 to 240 V
AC/DC
delay
Rated frequency 50/60 Hz common (at AC)
Rated control capacity 5 A, 250V AC (resistive load)
Time range 0.01s to 9990h, Selection of 8 range: 0.01s/0.1s/1s/0.1min/1min/0.1h/1h/10h
Operation mode Power ON delay Power ON delay (with reset and stop terminals)
Min. input signal width — 20ms (Reset and Stop inputs)*
Operating time fluctuation ±(0.01%+0.05s) in case of power on start
Time
accuracy*
Temperature error
1
Setting error
Voltage error
T.D. mode: Time delay 2C
Contact
Contact arrangement
INST. mode: Time delay 1C and
Instantaneous 1C (Use MODE switch on front)
Contact material Silver alloy
Life*
3
Mechanical (contact) Min. 10
Electrical (contact) Min. 105 (at rated control vltage)
Allowable operating voltage range 85 to 110% of rated operating voltage
Breakdown voltage
(Initial value)
Electrical
Insulation resistance
(Initial value)
Reset time Max. 0.1s
Functional 10 to 55 Hz: 1 cycle/min. single amplitude of 0.25 mm .010 inch (10 min on 3 axes)
Destructive 10 to 55 Hz: 1 cycle/min. single amplitude of 0.375 mm .015 inch (1h on 3 axes)
Functional 98 m/s2 (4 times on 3 axes)
Destructive 980 m/s2 (5 times on 3 axes)
Mechanical
Operating
conditions
Vibration
resistance
Shock
resistance
Ambient temperature –10°C to 55°C +14°F to +131°F
Ambient humidity Max. 85% RH (non-condensing)
Air pressure 860 to 1060 hPa
Mass (Weight) Approx. 130 g 4.59 oz Approx. 120 g 4.23 oz
Others
Available standards UL, C-UL, CE
Operating display LED (red), During time delay: blinking, After time delay: OFF
Notes: 1. Unspecified measuring conditions are rated operating voltage (in case of DC type, ripple rate of 5% or less), ambient temp. 20°C 68°F,
and stop time 1 second.
2. Reset start applies to QM4H-G type.
3. Excluding switches
4. Note that if the QM4H-G type is set to zero “0” and a STOP signal is input, output will begin when the power is turned on.
QM4H-S QM4H-G
12 V DC, 48 V DC: Max. 1.5W
12 V AC, 48 V AC: Max. 3.0 VA
12 V DC, 48 V DC: Max. 2.5W
12 V AC, 48 V AC: Max. 5.0 VA
100 V DC, 240 V DC: Max. 1.5W
100 V AC, 240 V AC: Max. 3.0 VA
100 V DC, 240 V DC: Max. 2.0W
100 V AC, 240 V AC: Max. 4.0 VA
±(0.005%+0.03s) in case of input reset start*
During time
delay
After time
delay
During time
delay
After time
delay
12 V DC, 48 V DC: Max. 1.0W
12 V AC, 48 V AC: Max. 2.0 VA
12 V DC, 48 V DC: Max. 1.5W
12 V AC, 48 V AC: Max. 3.5 VA
100 V DC, 240 V DC: Max. 1.0W
100 V AC, 240 V AC: Max. 2.5 VA
100 V DC, 240 V DC: Max. 1.8W
100 V AC, 240 V AC: Max. 3.2 VA
2
Operating voltage: 85 to 110% V
Temperature: –10 to +55°C +14 to 131°F (20°C 68°F)
Stopped time: 0.1 sec to 1 hour
Time delay 1C
7
Between live and dead metal parts, between input and output,
between contact sets, between contacts
Min. 100 MΩ (at 500 V DC megger)
Between live and dead metal parts: 2, 000 Vrms for 1 min
Between input and output: 2, 000 Vrms for 1 min
Between contact sets: 2, 000 Vrms for 1 min
Between contacts: 1, 000 Vrms for 1 min
4
45