Panasonic QA110K27CAU6 User Manual

MATSUSHITA Compressor Single Phase 115V
Hz
P
a
na
s
o
n
ic
MODEL# QA110K27CAU6 (100µF Start Cap.) R-134a 60
Voltage Range . . . . . . . . . 103 Volts to 127 Volts @ 60 Hz
Application . . . . . . . . . . . . High Back Pressure
Compressor Cooling . . . . Fan Cooling
Rated Performance Data
Capacity . . . . . . . . . . . . . . 3,926 Btu/h ±10% *
E.E.R. . . . . . . . . . . . . . . . . . 7.51 Btu/Wh ±10% *
Current . . . . . . . . . . . . . . . 6.06 Amps *
Nominal Motor Data Motor Input . . . . 523 Watts*
Rated Current . . 6.00 Amps
Type . . . . . . . . . CSIR, Current relay
Start Current . . . . . . . . . . 29.7 Amps
Coil Resistances Run . . . . 1.18 Ohms
@ 68°F (20°C) Start . . . 7.51 Ohms
*Test Conditions for Performance Specifications
Test Oil . . . . . . . . . . . . . . . . Freol α 22
Shell Temp . . . . . . . . . . . . . . 170.0°F / 76.0°C
Condensing Temp . . . . . . . . . 130.0°F / 54.4°C
Evaporating Temp . . . . . . . . . 45.0°F / 7.2°C
Ambient Temp . . . . . . . . . . . . 95.0°F / 35.0°C
Gas Superheat . . . . . . . . . . . 95.0°F / 35.0°C
Liquid Sub-Cooling . . . . . . . . 115.0°F / 46.1°C
Electrical Accessories
Overload Protector
Nominal Operating Characteristics
Model Name MST18ALZ Manufacturer Texas Instruments
Temperature To . . . . . . . . . . . Open: 248°F ± 9°F / 120°C ± 5°C
Trip Current . . . . . . . . . . . . . . @158°F (70°C) 8.0 Amps ± 7.5%
Current Relay Model
Nominal Operating Characteristics
Model Name MM5-E3CH Manufacturer Matsushita Pick Up Current 14.3 max. Amps Drop Out Current 12.0 max. Amps
Start Capacitor 100 µF 160 V (min.)
†Although these accessories are listed by UL/CSA for use with this compressor, Matsushita assumes no responsibility whatsoever for these or any other components sourced by the refrigeration system manufacturer from third parties.
Close: 142°F ± 20°F / 61°C ± 11°C
@77°F (25°C) 18.3 Amps @ 18 sec. max.
Refrigerant Control . . Capillary Tube Evaporator
Temp. Range . . . . . . . 23°F to 59°F / -5°C to 15°C
Performance Curves
650 600 550 500 450
Input Power (W)
400
30 35 40 45 50 55 60
7.0
6.8
6.6
6.4
6.2
6.0
5.8
Current (A)
5.6
5.4
5.2 30 35 40 45 50 55 60
6,000 5,500 5,000 4,500 4,000 3,500
Capacity (BTU/H)
3,000 2,500
30 35 40 45 50 55 60
9 – Point Data
Condensing Temp. Rating +30°F +45°F +59°F 140°F Btu/h 2,660 3,780 5,169
130°F Btu/h 2,759 3,926 5,364
120°F Btu/h 2,847 4,070 5,534
120°F 130°F 140°F
Evaporating Temp.
Watts 465 549 631 Amps 5.62 6.27 6.95 E.E.R. 5.72 6.89 8.19
Watts 448 523 593 Amps 5.51 6.06 6.64 E.E.R. 6.16 7.51 9.05
Watts 429 494 557 Amps 5.37 5.86 6.36 E.E.R. 6.64 8.24 9.94
®
Panasonic Industrial Company Refrigeration Products Department Tel: 201 - 392 - 4249 Fax: 201 - 392 - 4315 Rev#1-5/9
MATSUSHITA Compressor Single Phase 115V
P
a
na
s
o
n
ic
MODEL# QA110K27CAU6 (100µF Start Cap.) R-134a 60Hz
205.1mm (8.07")
165.1mm (6.50")
101.6mm
131.6mm (5.18")
Process or
Suction Tube
(4.00")
89mm (3.50")
F
88mm (3.46")
184mm DIA
(7.24")
88mm (3.46")
125mm (4.92")
4 holes
19mm (0.75") DIA
54mm (2.13")
DE
12.2mm (0.48")
84mm (3.50")
Discharge Tube
Process or Suction Tube
B
A
C
~
Starting Capacitor
C.S.I.R.
1 2
3
1
2
Current Relay
S
M
C
S
Compressor Motor
M
Dimensions*
mm inches
A
. . . . . . . . . . . . . . . . . . . . . 208.6 . . . . . . . . . . . . . . . . . . . 8.21
B
. . . . . . . . . . . . . . . . . . . . . 92.8 . . . . . . . . . . . . . . . . . . . . 3.65
C
. . . . . . . . . . . . . . . . . . . . . 115.8 . . . . . . . . . . . . . . . . . . .4.56
D
. . . . . . . . . . . . . . . . . . . . . 77.0 . . . . . . . . . . . . . . . . . . . . 3.03
E
. . . . . . . . . . . . . . . . . . . . . 62.2 . . . . . . . . . . . . . . . . . . . . 2.45
F
. . . . . . . . . . . . . . . . . . . . . 77.0 . . . . . . . . . . . . . . . . . . . . 3.03
*
All dimensions are for reference only
This document sets forth certain operational parameters and conditions for operation of this product. If this product is operated outside of the parameters and conditions stated herein, buyer assumes sole and full responsibility and shall indemnify seller with respect to all product failures and all consequences thereof. Operation of the product outside of the parameters and conditions specified herein shall serve to invalidate all seller warranties, if any, with respect to the product. This document is for reference only. For specifications, please contact Panasonic’s engineering department.
Tubes Tube O.D. Wall Material
Suction . . . . . . . . . . 0.39 in. / 10 mm 0.035 in. / 0.9 mm Copper
Process . . . . . . . . . 0.39 in. / 10 mm 0.035 in. / 0.9 mm Copper
Discharge . . . . . . . . 0.33 in. / 8.3 mm 0.035 in. / 0.9 mm Copper
U.L. File # . . . . . . . . . SA 4615
C.S.A. File #’s . . . . . . LR - 34080
LR - 36593 LR - 100738
General Data Oil Charge . . 250 cc ± 5 cc / 15.3 cu.in. ± 0.3 cu.in.
Net Weight With Oil . . . . . . . . . . . 22.2 lbs, 10.1 kg
Approved Oils . . . . . . . . . . . . . . . . . . FREOL α 22
Residual Moisture . . . . . . . . . . . . . . . 120 mg max.
Impurities . . . . . . . . . . . . . . . . . . . . . . 10 mg max.
Displacement . . . . . . . . . .10.86 cc. / 0.663 cu. in.
®
Panasonic Industrial Company Refrigeration Products Department Tel: 201 - 392 - 4249 Fax: 201 - 392 - 4315 Rev#1-5/9
Loading...