Panasonic PPDW12 Operating Instructions

Page 1
PRODUCT INSTRUCTION
Specification Revision Catalog Number Date Section
INSTRUCTIONS 3030 0998 Housing MODEL: PPDW12
DESCRIPTION:
The PPDW12 PressurDome™ pressurized upper dome is constructed from .090" aluminum, ABS plastic with UV additives and stainless steel. The assembled unit measures (h•w•d) 14.9" x 18.09" x 18.25" and weights a total of 22.9 lbs. (without camera). The housing is capable of withstanding a total of 5 psi of nitrogen gas injected through a Schraeder valve located on the 3/8" machined aluminum retaining ring. A pressure relief valve located next to the Schraeder valve provides an escape for pressure exceeding 5 psi. A 18 pin hermetically sealed connector is located in the back of the housing for control and power connections. Servicing the internal components can be accomplished by removing the aluminum/ABS top held in place by stainless steel machine screws. A stainless steel retaining cable is used to capture and hold the aluminum top when removed for servicing. The lower dome is constructed from free blown cast acrylic.
FEATURES:
• Aluminum and plastic construction ensures long-term protection against corrosive atmosphere.
• Sealed, nitrogen pressurized dome eliminates harm to internal components from moisture, dust and insects.
• Dry nitrogen eliminates fogging and build up of condensation within the housing.
• Standard 24 VAC heater, blower and surge protector.
• Unique, heavy duty construction provides improved protection from vandalism.
Electrical Specifications: Power PDW1T - 24 VAC, 52 vA, 2.16 amps PDW1TSR (Receiver Units) - 24 VAC, 68 vA, 2.8 amps Always use with Class 2 Power Supply
2. Always use safety goggles when servicing the unit.
3. An unregulated air supply should never be used to pressurize the enclosure. The valve should be regulated to allow a maximum air flow of 5 LPM per minute.
6. Be sure to periodically examine the unit and the attached supporting structure. If the dome shows any signs of wear such as stress cracking it should be replaced immediately.
General Instructions:
1. Carefully remove housing from packing material. Check to be sure all parts are present.
2. Remove wall mount bracket, by removing (4) 1/4 x 20 x 3/4" bolts and lock washers.
3. Remove wall mount cover.
4. Install wall mount bracket in desired location (Fig. A-1). Be sure bracket is properly and securely mounted to the supporting structure capable of maintaining the weight of the entire unit.
5. Connect incoming power and video wires to connector supplied. See fig. B-1 & F for pin out on connector. Note: It is helpfull to attach short leads (2.00") to video pins and solder these to video shield on coax cable.
6. Once bracket is secured attach PPDW12 housing to wall mount bracket. Allow shoulder bolts on the side of the housing to side into grooves on wall mount bracket. (Fig. C-1)
Plastic Sunshield
Inner Metal Liner
Heater - 24 VAC, 50 vA, close at 45F +/- 8F Blower - 1.4 vA continuous operation Connector - Sauriau 851 series Crimp tool - M22520/1-01 Crimp Tool Turret - M22520/1-02
Parts List
1. PPDW12 enclosure with attached wall mount.
2. Housing packet with 18 pin connector, 18 pins included.
Important Sefeguards Note: It is important to understand that the PPDW12 is a pressurized
enclosure and as such certain care is required for the safe use of this product.
1. Inspect enclosure upon opening product and be sure the unit has not been damaged during shipping. Domes that have been cracked or show any signs of damage should be replaced immediately.
O-Rings
Wall Mount Bracket
Exploded
Accessory Bracket
Camera Mount Bracket
Camera
Clear Dome
Page 2
1. Read Instructions - All the safety and operating instructions should
!
!
be read before the unit is operated.
2. Retain instructions - The safety and operating instructions should be retained for future reference.
3. Heed Warnings - All warnings on the unit and in the operating instructions should be adhered to.
4. Follow Instructions - All operating and user instructions should be followed.
5. Electrical Connections - Only a qualified electrician should make electrical connections.
6. Attachments - Do not use attachments not recommended by the product manufacturer as they may cause hazards.
7. Cable Runs - All cable runs must be within permissible distance.
8. Mounting - This unit must be properly and securely mounted to a supporting structure capable of sustaining the weight of the unit. Accordingly,
a. The installation should be made by a qualified installer and should
conform to all local codes.
b. Care should be exercised to select suitable hardware to install the unit,
taking into account both the composition of the mounting surface and the weight of the unit. Be sure to periodically examine the unit and the supporting structure to make sure that the integrity of the installation is intact. Failure to comply with the foregoing could result in the unit separating from the support structure and falling, with resultant damages or injury to anyone or anything struck by the falling unit.
ONE-YEAR LIMITED WARRANTY
Videolarm, Incorporated warrants that products sold hereunder shall be fit for the ordinary purpose for which said products are intended and shall be free from defects in material and workmanship for a period of one year from date of sale to buyer. Note that all electrical components will be warranted for a period of 1 year from date of sale to buyer. Videolarm makes no other warranty of any kind with respect to this product, whether expressed or implied, including, without limitation, the implied warranty of fitness for a particular purpose.
In the event of a breach of the above warranty, Videolarm shall, at its option, repair or replace said product. This is Videolarm's sole obligation under this warranty. In no event shall Videolarm be liable for any incidental or consequential damages, as defined in section 2-715 of the Uniform Commercial Code by a breach of this warranty.
Videolarm shall repair or replace defective products upon shipment of products prepaid to Videolarm, Inc., 2525 Park Central Blvd., Decatur, GA 30035.
SAFETY PRECAUTIONSIMPORTANT SAFEGUARDS
CAUTION
RISK OF
ELECTRIC SHOCK!
INSTALLATION BY QUALIFIED PERSONNEL ONLY.
The lightning flash with an arrowhead symbol, within an equilateral triangle, is intended to alert the user to the presence of non-insulated " dangerous voltage" within the product's enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.
The exclamation point within an equilateral triangle is intended to alert the user to presence of important operating and maintenance (servicing) instructions in the literature accompanying the appliance.
UNPACKING
Unpack carefully. Electronic components can be damaged if improperly handled or dropped. If an item appears to have been damaged in shipment, replace it properly in its carton and notify the shipper.
Be sure to save:
1. The shipping carton and packaging material. They are the safest material in which to make future shipments of the equipment.
2. These Installation and Operating Instructions.
SERVICE
The contact for Panasonic/Videolarm equipment is:
Panasonic Technical Center 52 West Gude Dr. Rockville, MD 20850-1150 Phone: (301) 762-5125 Fax : (301) 251-0347
Repairs made necessary by reason of accident, misuse or normal wear shall be charged at Videolarm's standard rate. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
Page 3
Fig. A
Fig. C
Fig.B
Video
Shield
485
Heater/Blower
Heater/Blower
B
C
D
L
A
MN
UT
P
R
S
EF
K
J
H
G
Fig. F (485 Control)
Video
Shield
Camera Ground
Heater/Blower
Heater/Blower
B
C
D
L
A
MN
UT
P
R
S
EF
K
J
H
G
Fig. F (for fixed camera or coax control)
Camera Power
Camera Power
Camera Power
Camera Power
7. Using the (4) 1/4 x 20 bolts and lock washers provided, secure housing to the wall mount bracket.
8. Connect 18 pin external connector to the housing.
9. To gain access to the internal compartment of the housing loosen (do not remove) (9) captive screws (See fig. D).
10.Attach unitized camera quick release bracket to housing bracket (Fig. E-1).
11.Install unitized camera. (Once installed it can be removed without having to unscrew housing bracket.) (Fig. E-2)
12.Complete all wiring. (Fig. E-3)
13.Test function of all internal equipment before reattaching top. Clean all interior surfaces of dome if necessary.
14.To reinstall top, carefully align notched area on the sides of the housing top with shoulder bolts and wall mount bracket. Housing top will drop in place if alignment is correct.
15.Secure all (9) of the captive screw fasteners. Fasteners need only to be hand tighten. Do not over tighten.
16.Pressurize housing noting precautions mentioned above.
17.Attach wall mount cover to bracket.
Note: The PPDW12 housing contains a strip of humidity sensitive tape. Tape will appear blue under normal dry conditions and will become pink if exposed to moisture or humidity.
Note: The cap must be installed on the Schraeder valve (air input valve) to ensure an airtight enclosure.
Video
Shield
Alarm In 1
Alarm In 2
Alarm Out
Alarm Out
Heater/Blower
Heater/Blower
C
Fig. F (receiver preset)
B
P
D
EF
A
UT
R
L
K
MN
J
H
S
G
Alarm In 3
Alarm In 4
Alarm In Common
Camera Power
Camera Power
Fig. D
Page 4
Fig. E-1
Fig. E-2
Description Part number Qty.
1 - Machined Plate 30-VL1221R1 1 2 - Captive Screw with Retainer 95-RSC01/95FSC02 9 3 - ABS Plastic Top 21-TOPDW12 1 4 - Shoulder Bolt 90-SB01 2 5 - 15" O-Ring 96-RSORG6 1 6 - 12" O-Ring 20-DT12PD 1 8 - Metal Top Shell 30-VL1241 1 9 - Top Pressure Ring 30-VL1256 1 10 - P/T Bracket 30-VL1275 1 11 - Fan-24 VDC 71-BLEH24 1 13 - Pressure Relief Valve
(located at back end) 95-VALV04 1 14 - Shraeder Valve 95-VALV01 1 15 - Wall Mount Bracket 50-VL1397 1 16 - 18 Pin Connector 70-PTO7H 1 17 - Wall Mount Cover 30-VL1400 1 18 - 18 Pin Connector B 70-PT06 1 19 - Connector Gasket 70-PH07HG.par 1
4-40 x 1_4 Pan Phil 90-BTRP26 4 21 - 1_4-20 X 3/4 Hex with Washer 4 22 - Dome Ring Clamps 30-VL1255 2
#10 Ext Thred Star Washer 92-WSTH02 12
10 x 32 x 375 Phil SS 90-BTRP20 12
SO-832-12.par 2
8 x 32 x 3/8" Phil SS 2
PCB Supports 95-PCST03 3 29 - Dill-rubber Gromment.par 1 30 - Dill-washer.par 1
.375 Jam Nut.par 1
#8 Ext. Thrs. Star Washer 92-WSTH02 4
8 x 32-1.25 SL RH ZP.par 4 33 - 6 x 32 x 3/8.par 2 34 - PCB 76-PD1PCB 1
Fig. E-3
8
34
14
29
30
16
33
18
15
Exploded view of housing and parts
6
2
17
21
4
3
5
13
10
1
22
9
11
All specifications subject to change without notice. Information furnished to Videolarm is believed to accurate and reliable. However, no responsibility or liability is assumed by Videolarm for its use, nor for any infringement of patents or other rights of hired parties which may result from its use. No license is granted by implication or otherwise under any patent or other rights of Videolarm.
Copyright 1997 by Videolarm Inc. All rights reserved
Printed in U.S.A.
Loading...