Before attempting to connect or operate this product,
please read these instructions completely.
for
®
TABLE OF CONTENTS
• CAUTION
1. PRECAUTIONS ON INSTALLATION
2. DESCRIPTION
3. INSTALLATION
3-1 Camera Installation
3-2 Dome Assembly
3-3 Wall Mount Bracket Installation
3-4 Dome Installation
3-5 Care and Maintenance
4. SYSTEM CONNECTION
5. SPECIFICATIONS
CAUTION
This unit must be properly and securely mounted to a supporting structure capable of sustaining the weight
of the bracket and camera assembly. Accordingly,
1. The installation should be made by a qualified installer.
2. The installation should be in compliance with local codes.
3. Care should be exercised to select suitable hardware to install the unit, taking into account both the
composition of the mounting surface and the weight the hardware will be required to sustain.
Be sure to periodically examine the unit and the supporting structure to make sure that the integrity of the
installation is intact.
Failure to comply with the foregoing could result in the unit coming loose from the support structure and
falling, with resultant damages or injury to anyone or anything struck by the falling unit.
PRECAUTIONS ON INSTALLATION
• Installation should be in accordance with all applicable local and National Electric codes. Only
approved materials should be utilized.
• This unit must be properly and securely mounted to a supporting structure that is capable of sustaining
the weight of the housing and dome along with the unitized camera.
• Read instruction completely before installation and operation.
DESCRIPTION
• This product has been designed and engineered for the combination camera WV - CS604 and WV-CS404
for ease of installation and service.
• This product is a discreet outdoor housing designed for pendant (POD7C) or wall mount (POD7CW)
applications.
- 2 -
Check all contents before beginning installation.
A. Housing Assembly (POD7C)Housing Assembly (POD7CW)
1. 2 1/4 Coupling w/ 2 set screws1. Wall Mount Bracket
2. Coupling Gasket2. Housing Gasket
3. Housing Mounting Bracket3. White Upper Top
4. Housing Gasket
5. White Upper Top
B. Bracket Assembly
1. Upper Housing Bracket
2. Lower Housing Bracket
3. 24 VDC Blower
4. 24 VAC Heater
5. PC Board Assembly
C. Dome Assembly
1. 7" Clear Plastic Dome
2. (3) Security Fasteners
D. Housing Packet
1. Security Tool
2. (4) 8 x 32 Bolts
3. (2) Molex Connector w/ 6 Pins
4. Instruction Manual
5. 1/4" x 20 x 1/2" Bolt
6. 1/4" Flat Washer
7. 1/4" Lock Washer
8. Plastic Lanyard
- 3 -
Housing Assembly
Bracket Assembly
2 1/4" Coupling*
Mounting Bracket*
Top Gasket
Housing top
Upper Housing Bracket
Dome Assembly
Lower Housing Bracket
Camera
7" Clear Dome
* Or Wall Mount
- 4 -
-3. INSTALLATION
3-1 Camera Installations
Snap out the area "X" from the unitized camera for
the cables exiting. A long nose plier is recommended.
Note: Round off all sharp edges with file to avoid
injury.
Connect the power cable and video cable lines.
Loop excess cables through the cable clamp.
"X"
Attach camera mount bracket of unitized camera
to dome bracket, using the standard screw (A).
Camera Mount Bracket
Attach the unitized camera to dome bracket (first,
hang the safety wire to the camera bracket). Then
attach the safety screw to camera mount bracket,
using the standard screw (s).
Connect
3-2 Dome Assembly
Use the black handle security tool to attach the
dome to the housing.
3-3 Wall Mount Bracket Installation
Note: Mounting hardware not included. Care should
be exercised to select suitable hardware to mount
the unit.
Set Screw
Safety Screw
Compatible brackets for POD7C/POD7CW:
• Parapet Mount Bracket - PSRCW-2000
• Corner Mount Bracket - PCA-2
• Pole Mount Bracket - PPM-3
- 5 -
Assemble the power cable with the provided
connector (included in housing packet).
Up
Wire
Front view of the female connector in housing cable.
Pin 1 is in the lower right hand corner.
3
4
1
2
34
2
1
Connector A - Camera Power
Connector B - Heater/Blower Power
Connector Information Pin
1. AC 24 VAC Live
2. AC 24 VAC Neutral
3. Not Used
4. Ground
CAUTION: For lightning protection of the camera
and heater/blower, the pin 3 of the connector must
be connected to real electrical ground.
HOW TO ASSEMBLE THE CONNECTOR
• Strip back the cable jacket approximately 0.1 inch
(3 mm) and separate the individual conductors.
Approx. 0.1"
Wire
Contact
CAUTIONS
• Shrinking the cable-entry seal is a onetime
procedure. Do not shrink the cable-entry seal until
it has been determined that the unit is functioning.
• CONNECT THIS TO A 24 VAC CLASS 2 POWER
SUPPLY ONLY.
3
1
4
2
4
2
3
1
CAUTION: TO PREVENT FIRE OR SHOCK HAZARD, THE
UL-LISTED WIRE VW-1, STYLE 1007, SHOULD BE USED
FOR THE CABLE FOR 24 VAC INPUT TERMINALS.
OPERA TING DISTANCES
Awg SizeImpedanceMax Distance
Awg #121.71 ohm/1000 ft.440 ft.
Awg #142.73 ohm/1000 ft.270 ft.
Awg #164.35 ohm/1000 ft.170 ft.
Awg #186.92 ohm/1000 ft.100 ft.
Up
Insert
Contact
Prepare the individual conductors for clamping. If
clamping, use Molex brand tool part number 570275000 (for UL-listed-style cable UL1015) or 57026-5000
(for UL-listed-style cable UL1007).
After clamping the contacts, push them into the
proper holes in the connector housing until they snap
in place.
3-4 Pendant POD7C- Connections
Attach coupling to 1 1/2 NPT thread pipe. Note: Seal
thread with a bead of silicone sealer to ensure
water-tight fit.
- 6 -
Connect the power cable and video cable lines.
Attach dome assembly to coupling. Secure screws
Wire hook can be used as temporary support.
(C).
Secure C
with extreme care.
• If debris and dust accumulates on the dome's
inner surface, remove with clean air pressure.
Compressed air cans are available for this use at
most photography supply stores.
• If the surface doesn't clean properly with
compressed air, use a nonabrasive cleaner that is
acceptable for use on acrylic. Do not use any
other type of cleaner. This may result in scratches
to the dome's surface.
For service of Panasonic/Videolarm equipment
contact:
Panasonic Technical Center
52 West Gude Dr.
Rockville, MD 20850-1150
Phone: (301) 762-5125/ Fax: (301) 251-0347
4. System Connection
Example 1: Connect the coaxial cable between the
video output connector on the WV-CS404 and the
camera input connector on the WV-CU101.
Secure safety screw (D) to housing mounting bracket
with plane washer (G) and lock washer (F).
G F D
3-5 Care and Maintenance
• The lower dome is an optical surface. When
cleaning the inner surface of the dome, handle
Video Monitor
WV-CU101
- 7 -
Example 2: Connect the coaxial cable between the
video output connector on the WV-CS404 and the
camera input connector on the WV-CU254.
Note: For the connections in the diagram, refer to
the operating instructions for each product.
Example 3: Connect the coaxial cable between the
video output connector on the WV-BS204, WV-CS404,
WV-CS604 and the camera input connector on the
WV-CU254.
SPECIFICATIONS
MECHANICAL/ELECTRICAL
Upper Housing - .25" high impact, UV-stable white plastic
Housing Bracket - 14- and 16-gauge steel
Lower Dome - 7" distortion-free acrylic
Unit Weight - Camera 4.4 lbs.; domed housing 6.6 lbs.
Environmental - -20° to 120° F
Heater - On at 40° F, off at 60° F (+/-5°) 60 vA
Blower - Continuous, .11A
Surge Protector:
Video clamping - Differential mode 27-36V
common mode 54-72 V
Power clamping - 240 - 300V
STANDARD CONFIGURATION
Item or Sub-ItemDescription
20-DCPOD77" CLEAR DOME POD7
21-TOPOD7HOUSING TOP FOR POD7
30-VL1372UPPER HOUSING BRACKET, POD-7C
30-VL1379LANYARD ,7" DOMES
30-VL917POD-12C 2 1/4" COUPLING
30-VL926POD12C MOUNTING BRACKET
40-BRPOD7BRACKET ASSY POD7
30-VL1371LOWER HOUSING BRACKET, POD-7C
60-WPBNC1BNC PLUG 75 OHM FOR RG 179
70-WPMX01WM3701 (4) CIR/PLUG
70-WPMX02Molex 39-00-0039 FEMALE PIN
71-BLEH2424VDC Blower .11A
72-HTPOD1224VAC Heater 50 Watts
76-PODPCBPC Board Assembly
90-BTRP198-32 X 3/8 RD HD PHIL SS
91-NTHH068-32 HEX NUT SS
92-WSTH02#8 EXT TTH STAR L/W STAINLESS
94-FSCT01CABLE TIE NYLON NAT.
94-FSSR03HEYCO 1060 SR 2M-1 BLK STRAIN
95-MX2025MOLEX RECEPTACLE
95-PCST02TTW FASTEX PCB SUPPORTS
95-PCST03ITW FASTEX 232-120207-30
40-CAPOD701COAXIAL CABLE ASSY. FOR POD7
40-CAPOD702POD-12C CABLE ASSY. B
40-PKPOD7PACKET ASSY FOR POD7C
70-WPMX10Molex 39-01-4030
90-BTHH321/4-20 X 1/2" HX HD SS MS
90-BTHH391/4-20 x 3/8" HX HD SS MS
90-BTSS051/4-20 x 1/2" SET SCREW
92-WSFL011/4 SAE FLAT WASHER 18-8 SS
92-WSSL011/4 SPLIT LOCKWASHER 18-8 SS
94-FSLG01 HEYCO WIRE HOLDER #3630 WT
94-FSRT01RETAINER BLACK NYLON
95-FSSL03HOOK LOOP CABLE POD12C
95-FSSL04CABLE FERRULES
95-FSTS03TOOLHEAD SCREW
96-PSGK04VL-1433 POD-12C TOP GASKET
96-PSGK05VL-1014 POD-12C BOTTOM GASKET
- 8 -
.114
7.000
2.08412.861
1.405
9.169
14.169
.089
7.000
3.432
Gasket
Set Screws
Coupling for 1 1/2" standard pipe
Slot safety screw
(located on both sides)
Rev. # 3029/0200