Panasonic LC-WTP1212 User Manual

)
t
g
)
LC-WTP1212
)
For pitch backup systems in wind turbines
Expected life: 10 years at 20℃, 5 years at 25℃
(based on a weekly discharge cycle of max 15 seconds)
Dimensions(mm
Terminal type (option
6.35
4.5
Contents indicated (including the recycle marking, etc) are subject to change without notice.
Specification
Nominal Voltage 12V
Rated Capacity(20HR)
Length
Dimensions
Approx. Mass
Terminal
Width
Height
Total height
Characteristics
Capacity
(25 )
Temperature
Dependency of
Capacity
(20 hour rate)
Self Discharge
(25 )
10 hour rate
3 hour rate 9.3Ah
1 hour rate
Fully charged battery
(25 )
40
25
0
-15
After 3 months
After 6 months 82%
After 12 months
12Ah
151 mm
98 mm
94 mm
100 mm
3.85 kg
250M
12Ah20 hour rate
10Ah
8.1Ah
15 mInternal Resistance
102%
100%
85%
65%
91%
64%
Battery case resin: Flame-retardant (UL94V-0)
Duration of discharge vs. discharge curren
30
20
40
25
-15
31030
Duration of discharge
10
5
(hour)
3
60
30
10
(minute)
5
3
1
0.1
0.3
0
1
Discharge current(A)
100
Lar
e current discharge characteristics(25
Peak current(A for milliseconds) 267 250 233 217 200 187 175 157 143 133 125 Discharge current(A) 240 225 210 195 180 168 158 142 130 120 113 Discharge time(sec) 3 6 10 15 20 25 30 40 50 60 70
Peak current(A for milliseconds) 117 110 103 98 92 87 82 77 73 70 67 Discharge current(A) 105 100 93 88 83 78 73 70 67 63 60 Discharge time(sec) 80 90 100 110 120 130 140 150 160 170 180
The cut off voltage should be more than 8.0V. Battery should be charged after each discharge.
Charging Method
**Control voltage: 13.6V~13.8V at 20~25 with temperature compensation, Initial current: 1.80A or smaller
**Please consult us for the right control voltage if the ambient temperature is different.
Operating Temperature Range
*Storage
-40~ 50
* For storage, please ensure that battery is fully charged.
Charge
-20~ 50
Discharge
-20~ 50
Data in this sheet are for reference only and are not guaranteed values.
1/1 2009.06