Panasonic LC-R063R4P User Manual

VALVE-REGULATED LEAD ACID BATTERIES: INDIVIDUAL DATA SHEET
0
)
)
)
LC-R063R4P
Specifications
Nominal Voltage
Rated Capacity (20 hour rate)
Dimensions
Total Height
Approx. mass
Standard T erminals
and Resin
UL94HB Faston 187
Photo/Label for reference only.
Length
Width
Height
5.276 inches (134.0 mm
1.339 inches (34.0 mm)
2.362 inches (60.0 mm)
2.598 inches (66.0 mm)
1.37 lbs. (0.62 kg) LC-R063R4P
6V
3.4Ah
For main and standby power supplies. Expected trickle life: 3-5 years at 25°C, Approx. 5 years at 20°C.
Dimensions (mm)
Terminal type: Faston 187
+
0.059
+
5.276
0.020
-
1.5
+
(134 )
0.5
-
5.12 (129.8)
5.236 (133)
0.012 (0.3)
Battery case resin: Standard (UL94HB) Color is black.
Discharge characteristics 77°F (25°C)
7.2
6.9
6.6
6.3
6.0
5.7
5.4
5.1
4.8
4.5
4.2
Terminal voltage (V)
3.9
0 1 2 4 6 8 10 20 40 60 2 4 6 8 10 20 40
(Minute) (Hour)
3.4A
Duration of discharge
+
1.339 0.039 (34 1)
-
0.398 (10.1)
0.236 (6)
-
+
-
+
2.362 0.039
(60 1)
1.319 (33.5)
0.85A
1.7A
+
-
0.398 (10.1)
(Note)
0.34A
0.17A
Capacity
Internal Resistance
Temperature dependency
(20 hour rate)
Self discharge
Charge Method
(Constant
Voltage)
(note)
77˚F (25˚C)
of capacity
77˚F (25˚C)
Cycle use
(Repeating
use)
Trickle use
20 hour rate (170mA) 10 hour rate (300mA) 5 hour rate (540mA) 1 hour rate (2100mA)
1.5 hour rate discharge Cut-off voltage 5.25 V
Fully charged battery
77˚F (25˚C)
104˚F (40˚C)
77˚F (25˚C) 32˚F (0˚C)
5˚F (-15˚C)
Residual capacity
after standing 3 months
Residual capacity
after standing 6 months
Residual capacity
after standing 12 months
initial current
Control voltage
initial current
Control voltage
3.4Ah 3Ah
2.7Ah
2.1Ah
1.5A
Approx. 30m
102% 100%
85% 65%
91% 82% 64%
1.36 A or smaller
7.25V to 7.45V
(per 6V cell 25˚C
0.51 A or smaller
6.8V to 6.9V
(per 6V cell 25˚C
Duration of discharge vs. Discharge current
30 20
15 10
5 4 3
2
1.5 1
50 40
30
Duration of discharge
20
10
(Minute) (Hour)
5
3
30 50 100 300 500 1 3 5 1
5˚F (-15˚C)
32˚F (0˚C)
(mA) (A)
Discharge current
104˚F (40˚C)
77˚F (25˚C)
(Note)
(Note) The above characteristics data are average values obtained within three charge/discharge. Cycles not the minimum values.
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to modification without notice. Contact Panasonic for the latest information.
VRLA BATTERIES AUGUST 2005
Loading...