Page 1
ORDER NO. KM40204852C3
Telephone Equipment
KX-TC1205RUB
KX-TC1205RUW
KX-TC1205RUS
KX-TC1205RUF
Cordless Phone
Black Version
White Version
Silver Version
Blue Version
(for Russia)
© 2002 Kyushu Matsushita Electric Co., Ltd. All
rights reserved. Unauthorized copying and
distribution is a violation of law.
Page 2
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
CONTENTS
Page Page
1 BATTERY 4
1.1. Recharge
1.2. Battery information
2 BATTERY REPLACEMENT
3 LOCATION OF CONTROLS
3.1. Base Unit
3.2. Handset
4 CONNECTION
4.1. Adding Another Phone
5 OPERATIONS
5.1. Making Calls
5.2. Answering Calls
5.3. Storing Phone Numbers in Memory
5.4. Storing a Phone Number in the DIRECT Button
5.5. Dialing a Stored Number
5.6. Dialing a Stored Number in the DIRECT Button
5.7. FLASH Button
6 DISASSEMBLY INSTRUCTIONS
7 TROUBLESHOOTING GUIDE
7.1. Check Power
7.2. Bell Reception
7.3. Check Battery Charge
7.4. Check Link
7.5. Check Handset Transmission
7.6. Check Handset Reception
10
10
10
11
11
12
12
13
14
16
17
18
19
20
22
22
8 ADJUSTMENTS (BASE UNIT)
4
4
5
6
6
6
7
9
8.1. Test Mode Flow Chart (Base Unit)
8.2. How to change the channel
8.3. Adjustment
8.4. Adjustment Standard (Base Unit)
9 ADJUSTMENTS (HANDSET)
9.1. Test Mode Flow Chart (Handset)
9.2. How to change the channel
9.3. Adjustment
9.4. Adjustment Standard (Handset)
10 R F SPECIFICAT ION
10.1. Base Unit
10.2. Handset
11 HOW TO CHECK THE HANDSET SPEAKER
12 FREQUENCY TABLE (MHz)
13 EXPLANATION OF CPU DATA COMMUNICATION
13.1. STAND-BY -> TALK, TALK -> STAND-BY
13.2. Ringing
13.3. Changing the Channel
13.4. Ports for transmitting and receiving of data
13.5. Waveform of DATA used for cordless transmission and
reception
14 BLOCK DIAGRAM (BASE UNIT)
15 BLOCK DIAGRAM (HANDSET)
16 CIRCUIT OPERATION
23
23
24
24
25
26
26
27
27
28
30
30
30
30
31
32
32
33
34
35
35
36
37
38
2
Page 3
16.1. Outline 38
16.2. Power Supply Circuit
16.3. Reset Circuit (Base Unit)
16.4. Charge Circuit
16.5. Telephone Line Interface
16.6. Transmitter/Receiver
16.7. Signal Route
17 CIRCUIT OPERATION (HANDSET)
17.1. Reset Circuit (Handset)
17.2. Battery Low / Power Down Detector
18 CP U DATA (Base Unit)
18.1. IC2
19 CP U DATA (Handset)
19.1. IC2
20 HOW TO REPLACE FLAT PACKAGE IC
20.1. Preparation
20.2. Procedure
20.3. Modification Procedure of Bridge
21 CABINET AND ELECTRICAL PARTS LOCATION (BASE UNIT)
22 CABINET AND ELECTRICAL PARTS LOCATION (HANDET)
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
23 ACCESSORIES AND PACKING MATERIALS
24 REPLACEMENT PARTS LIST
39
40
41
41
42
44
45
45
46
47
47
48
48
49
49
49
49
24.1. Base Unit
24.2. Handset
24.3. ACCESSORIES AND PACKING MATERIALS
25 FOR SCHEMATIC DIAGRAM
25.1. Base Unit (SCHEMATIC DIAGRAM (Base Unit))
25.2. Handset (SCHEMATIC DIAGRAM (Handset))
26 SCHEMATIC DIAGRAM (Base Unit)
26.1. Base Unit
26.2. RF Unit (Base Unit)
27 SCHEMATIC DIAGRAM (Handset)
27.1. Handset
27.2. RF Unit (Handset)
28 CIRCUIT BOARD (Base Unit)
28.1. Component View
28.2. Flow Solder Side View
29 CIRCUIT BOARD (Handset)
29.1. Component View
50
29.2. Flow Solder Side View
51
52
53
53
56
58
59
59
59
60
60
61
62
62
63
65
65
66
67
67
68
3
Page 4
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
1 BATTERY
1.1. Recharge
1.2. Battery information
4
Page 5
2 BATTERY REPLACEMENT
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
5
Page 6
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
3 LOCATION OF CONTROLS
3.1. Base Unit
3.2. Handset
6
Page 7
4 CONNECTION
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
• • USE ONLY WITH Panasonic AC ADAPTOR PQLV16CEZ.
• • The AC adaptor must remain connected at all times.
(It is normal for the adaptor to feel warm during use.)
• • When more than one unit is used, the units may interfere with each other. To prevent or reduce interference, please leave
ample space between the base units.
7
Page 8
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
8
Page 9
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
4.1. Adding Another Phone
This unit will not function during a power failue. To connect a standard telephone on the same line, use a telephone T-adaptor.
9
Page 10
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
5 OPERATIONS
5.1. Making Calls
5.2. Answering Calls
10
Page 11
5.3. Storing Phone Numbers in Memory
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
5.4. Storing a Phone Number in the DIRECT Button
11
Page 12
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
5.5. Dialing a Stored Number
5.6. Dialing a Stored Number in the DIRECT Button
12
Page 13
5.7. FLASH Button
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
13
Page 14
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
6 DISASSEMBLY INSTRUCTIONS
Show in Fig. To remove. Remove.
1 Lower Cabinet Screws (2.6 × 12)....................... (A) × 4
2 Main P.C. Board Screws (2.6 × 6)......................... (B) × 1
Screws (2.6 × 6)..........................(C) × 2
Screws (2.6 × 12)........................(D) × 1
Main P.C. Board.
14
Page 15
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
Show in Fig. To remove. Remove.
3 Rear Cabinet Battery compartment cover.
4 Screws (2.6 × 12)......................(E) × 2
5 Main P. C. Board Screw (2.6 × 12)........................(F) × 1
Tape and solder.
Main P. C. Board.
15
Page 16
KX-TC1205RUB / KX-TC1205R UW / KX-TC1205RUS / KX-TC1205RUF
7 TROUBLESHOOTING GUIDE
Cross Reference:
Check Power (P.17)
Bell Reception (P.18)
Check Battery Charge (P.19)
Check Link (P.20)
Check Handset Transmission (P.22)
Check Handset Reception (P.22)
16
Page 17
7.1. Check Power
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
Cross Reference:
Reset Circuit (Base Unit) (P.40)
Power Supply Circuit (P.39)
Cross Reference:
Charge Circuit (P.41)
*: Each measurement points are shown in CIRCUIT BOARD (Base Unit) (P.65) or CIRCUIT BOARD (Handset) (P.67)
Note:
CPU: IC2
Note:
CPU: IC2
17
Page 18
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
7.2. Bell Reception
Cross Reference:
Check Link (P.20)
Telephone Line Interface (P.41)
Cross Reference:
Check Link (P.20)
*: Each measurement points are shown in CIRCUIT BOARD (Base Unit) (P.65) or CIRCUIT BOARD (Handset) (P.67)
Note:
CPU: IC2
18
Page 19
7.3. Check Battery Charge
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
Cross Reference:
Charge Circuit (P.41)
Power Supply Circuit (P.39)
Cross Reference:
Reset Circuit (Handset) (P.45)
*: Each measurement points are shown in CIRCUIT BOARD (Base Unit) (P.65) or CIRCUIT BOARD (Handset) (P.67)
Note:
CPU: IC2
Note:
CPU: IC2
19
Page 20
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
7.4. Check Link
**: Refer to Adjustment (P.24) Note:
CPU: IC2
RF IC: IC1
*: Each measurement points are shown in CIRCUIT BOARD (Base Unit) (P.65) or CIRCUIT BOARD (Handset) (P.67)
20
Page 21
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
**: Refer to Adjustment (P.27). Note:
CPU: IC2
RF IC: IC1
*: Each measurement points are shown in CIRCUIT BOARD (Base Unit) (P.65) or CIRCUIT BOARD (Handset) (P.67)
21
Page 22
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
7.5. Check Handset Transmission
Cross Reference:
Signal Route (P.44)
7.6. Check Handset Reception
Cross Reference:
Signal Route (P.44)
*: Each measurement points are shown in CIRCUIT
BOARD (Base Unit) (P.65) or CIRCUIT BOARD (Handset)
(P.67)
22
Page 23
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
8 ADJUSTMENTS (BASE UNIT)
If your unit have below symptoms, adjust or confirm each item using remedy column from the table.
Symptom Remedy*
The base unit dose not respond to a call from handset. Make adjustments in item (A)
The base unit dose not transmit or the transmit frequency is off. Make adjustments in item (B)
The transmit frequency is off. Make confirmation in item (C)
The transmit power outlet is low, and the operating distance between the base unit and the
handset is less than normal.
The reception sensitivity of base unit is low with noise. Make confirmation in item (E)
The transmit level is high or low. Make confirmation in item (F)
The reception level is high or low. Make adjustments in item (G)
The unit does not link. Make confirmation in item (H)
*: Refer to Adjustment (P.24).
8.1. Test Mode Flow Chart (Base Unit)
The operation-flow of Test mode and main check items are shown below.
Make confirmation in item ( D)
Note:
**: Refer to the above table.
23
Page 24
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
8.2. How to change the channel
*: Refer to Flow Solder Side View (P.66).
8.3. Adjustment
Adjustment Items Test Mode Adjustment
(A ) RX VCO
Confirmation
(B ) TX VCO
Adjustment
(C ) TX Frequency
Adjustment
(D ) TX Power
Adjustment
(E ) RX Sensitivity
Adjustment (2nd
IF output)
(F ) Line Output Level
Confirmation
(G ) Line Input
Modulation
Confirmation
(H ) Noise Squelch
Confirmation
3ch Talk -
3ch Talk T6
3ch Talk VC1
3ch Talk T5
3ch Talk T2 1. Apply -60dBm output from S.S.G. (modulation frequency 1KHz, dev.
3ch Talk - 1. Apply -60dBm output from S.S.G. (modulation frequency 1KHz, dev.
3ch Talk - 1. Input via loop simulator 1.0KHz, 80mV (measured at T-R) signal.
3ch Talk - 1. Measure the SSG output level when the noise squelch changes from Low
Point
*Procedure Check or
• • Confirm so that the reading of the Digital Voltmeter is 1.5V ± 0.5V.
• • Adjust T6 so that the reading of the Digital Voltmeter is 2.0V ± 0.1V.
• • Adjust VC1 so that the reading of the frequency counter is 30.175MHz ±
0.1KHz.
• • Adjust T5 so that the reading of the RF VTVM is over 10dBm.
0KHz).
2. Adjust T2 so that the reading of RF VTVM is the maximum value (more
than 20mV)
3KHz).
2. Confirm that the reading of AF VTVM is 80mV ± 20mV (600Ω load).
2. Apply -60dBm output from S.S.G. (modulation frequency 1KHz, dev.
0KHz).
3. Confirm so that the reading of FM Deviation Meter is 2.8KHz ± 0.3KHz.
to High.
2. Confirm so that the SSG output level is -105dBm ~ -110dBm.
Replace
Parts
IC1, L10,
C26
IC1, DV1,
T6
IC1, X1,
T6,
DV1, C35,
C40, VC1
IC1, Q3,
Q4, Q5,
T5, DPX1
DPX1, T2,
CF1, CF2
IC1, Q11
IC1, DV1
IC1, DPX1
* : The connection of adjustment equipment are as shown in Adjustment Standard (Base Unit) (P.25).
SSG Frequency: 39.875 MHz
24
Page 25
8.4. Adjustment Standard (Base Unit)
25
DC12V or
AC adaptor
AF OSC
Loop
SIMULATOR
FM Deviation
Meter
Frequency
Counter
RF
Volt Meter
50Ω
SSG
TXPOWER TXGND
Audio
Analyzer
(G )
(C )
(D )
Confirmation of VCO voltage
DC Volt Meter
(A ), (B )
TX-VCO RX-VCO
RF Volt
Meter
(E )
T.P ( CH change at test mode)
IC1
IC2
AF Volt Meter (F)
Note: (A) - (H) is refered to ADJUSTMENTS (BASE UNIT) (P.23)
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
IC3
IC6
Oscilloscope (H)
Page 26
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
9 ADJUSTMENTS (HANDSET)
If your unit have below symptoms, adjust or confirm each item using remedy column from the table.
Symptom Remedy*
The movement of Battery Low Indicator is wrong. Make confirmation in item (A)
The base unit does not respond to a call from the handset. Make adjustments in item (B)
The base unit does not transmit or the transmit frequency is off. Make adjustments in item (C)
The transmit frequency is off. Make confirmation in item (D)
The transmit power outlet is low, and the operating distance between the base unit and the
handset is less than normal.
The reception sensitivity of base unit is low with noise. Make confirmation item (F)
Does not link between the base unit and the handset. Make confirmation in item (G)
The reception level is high or low. Make confirmation item (H)
The transmit level is high or low. Make adjustments in item (I)
*: Refer to Adjustment (P.27).
Unit condition:
1. Remove the antenna lead wire from P.C Board of the handset.
2. Power Supply: DC 3.9V (DC power supply)
3. Volume: HIGH (When P.C. Board of handset is in test mode, volume condition is medium. Press “LOCATOR” key once.)
4. Speaker Load: 150Ω
CH TX Frequency RX Frequency
CH3 39.875MHz 30.175MHz
Make confirmation in item (E)
9.1. Test Mode Flow Chart (Handset)
Note:
Refet to CIRCUIT BOARD (Handset) (P.67)
Signal Route (P.44)
26
Page 27
9.2. How to change the channel
9.3. Adjustment
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
Adjustment Items Test Mode Adjustment
(A ) Battery Low
Confirmation
(B ) TX VCO
Voltage
(C ) RX VCO
Confirmation
(D ) TX Frequency
Adjustment
(E ) TX Power
Adjustment
(F ) RX Sensitivity
Adjustment
(2nd IF output)
(G ) Noise Squelch
Confirmation
(H ) Speaker
Output Level
confirmation
(I ) Mic Modulation
Factor
Confirmation
(J ) Data
Modulation
Confirmation
3ch Talk - 1. Set the power supply voltage to DC3.60V, and confirm so that the reading
3ch Talk T6 1. Adjust T6 so that the reading of the Digital Voltmeter is 1.0V ± 0.1V. IC1, X1,
3ch Talk -
3ch Talk VC1
3ch Talk T5
3ch Talk T3 1. Apply -60dBm output from S.S.G. (modulation frequency 1KHz, dev.
3ch Talk - 1. Measure the SSG output level when the noise squelch changes from Low
3ch Talk - 1. Apply -60dBm output from S.S.G. (modulation frequency 1KHz, dev.
3ch Talk - 1. Apply a MIC signal (1KHz, 2.4mV at 600Ω load).
3ch Talk -
Point
Procedure Check or
of oscillosope is High.
2. Set the power supply voltage to DC 3.40V, and confirm so that the
reading of oscilloscope is Low.
• • Confirm RX VCO voltage so that the reading of the Digital Voltmeter is
2.9V ± 0.5V.
• • Adjust VC1 so that the reading of the frequency counter is 39.875MHz ±
0.1KHz.
• • Adjust T5 so that the reading of the RF VTVM (50Ω load) is 5dBm ±
1dBm.
0KHz).
2. Adjust T3 so that the reading of RF VTVM is more than 15mV.
to High. (modulation frequency 1KHz, dev.3kHz)
2. Confirm so that the SSG output level is -105dBm.
3KHz).
2. Confirm so that SP output level is 120mV ± 30mV.
(distortion: less than 7%) (volume High).
2. Confirm so that the reading FM Deviation Meter is 3.1KHz ± 0.4KHz.
• • Confirm so that the reading of the FM Deviation Meter is 5kHz ± 1kHz.
Replace
Parts
IC1
T6
IC1, X1,
T6
L6, C24
IC1, VC1
DPX1, T5
DPX1, Q5,
T5
DPX1,
T3,IC1,
CF1, CF2
IC1, DPX1
IC1
IC1, DV1
The connections of adjustment equipment are as shown in Adjustment Standard (Handset) (P.28).
SSG Frequency: 30.175 MHz
27
Page 28
9.4. Adjustment Standard (Handset)
(Component View)
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
28
150Ω
AF Volt Meter (H)
IC2
(A ) Battery Low
(G ) Noise Squelch
Oscilloscope
47µ F
+
-
AFGenerator
Note: ( A)-(I) is refered to ADJUSTMENTS (HANDSET) (P.26)
Page 29
(Flow Solder Side View)
29
Audio
Analyzer
(E )
(D )
(I ), (J )
SSG
43.820MHz
RF Millivolt
Meter
Frequency
Counter
FM Deviation
Meter
50Ω
(F )
RF
Volt Meter
TXPOWER TXGND
TX VCO
DC Volt Meter (B )
RX VCO
DC Volt Meter (C )
Note: (A)-(I) is refered to ADJUSTMENTS (HANDSET) (P.26)
IC1
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
DC Power
Supply
Page 30
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
10 RF SPECIFICAT ION
10.1. Base Unit
Item Value Refer to -.* Remarks
TX Frequency 30.175 MHz ± 0.1kHz ADJUSTMENTS (BASE UNIT) (C) at CH3
TX Power 8mW (3CH) ADJUSTMENTS (BASE UNIT) (D) at CH3
Line Modulation factor 2.8 kHz~3.4 kHz ADJUSTMENTS (BASE UNIT) (G)
Line Modulation factor (Max.) 4.5 kHz~8.5 kHz —
Data Modulation factor 3 kHz~7 kHz —
Line Output level 80mV ± 20mV —
*: Refer to Adjustment (P.24).
10.2. Handset
Item Value Refer to -.** Remarks
TX Frequency 39.875 MHz ± 0.1kHz ADJUSTMENTS (HANDSET) (D) at CH3
TX Power 4mW (3CH) ADJUSTMENTS (HANDSET) (E) at CH3 (Antenna
Data Modulation factor 4.0 kHz/dev~8.0 kHz/dev ADJUSTMENTS (HANDSET) (J) at CH3
MIC Modulation factor 1.5 kHz/dev~0.3 kHz/dev ADJUSTMENTS (HANDSET) (I) at CH3 (MIC terminal
SP Output level 120mV ± 30mV —
**: Refer to Adjustment (P.27).
soldering point 50Ω
Load)
2.4mV Input)
11 HOW TO CHECK THE HANDSET SPEAKER
1. Prepare the digital voltmeter, and set the selector knob to ohm meter.
2. Put the probes at the speaker terminals as shown below.
30
Page 31
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
12 FREQUENCY TABLE (MHz)
BASE UNIT PORTABLE UNIT
Channel Transmit Frequency Receive Frequency Transmit Frequency Receive Frequency
1 30.0750 39.7750 39.7750 30.0750
2 30.1250 39.8250 39.8250 30.1250
3 30.1750 39.8750 39.8750 30.1750
4 30.2250 39.9250 39.9250 30.2250
5 30.2750 39.9750 39.9750 30.2750
6 30.1000 39.8000 39.8000 30.1000
7 30.1500 39.8500 39.8500 30.1500
8 30.2000 39.9000 39.9000 30.2000
9 30.2500 39.9500 39.9500 30.2500
10 30.3000 40.0000 40.0000 30.3000
31
Page 32
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
13 EXPLANATIO N OF C PU DATA COMMUNICATION
13.1. STAND-BY -> TALK, TALK -> STAND-BY
*: The channel is changed if the noise interferes with the conversation.
32
Page 33
13.2. Ringing
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
33
Page 34
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
13.3. Changing the Channel
34
Page 35
13.4. Ports for transmitting and receiving of data
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
Handset:
transmitting (TX) ... 36 Pin
receiving (RX) ... 4 Pin
Base Unit:
transmitting (TX) ... 17 Pin
receiving (RX) ... 10 Pin
13.5. Waveform of DATA used for cordless transmission and reception
The DATA which is transmitted from the Handset to the Base Unit is combination of DATA 0, DATA 1, PSEUD.
The DATA which is transmitted from the Base Unit to the Handset is combination of DATA 0, DATA 1, PSEUD.
13.5.1. Handset
13.5.2. Base Unit
• • For example (one of part of data)
35
Page 36
14 BLOCK DIAGRAM (BASE UNIT)
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
36
H/S
DUPLEXER
DPX1
RX LOOP
TX LOOP
RF AMP
Q3,Q4, T5
ANTENNA
X1
RX VCO
L10, C26
RF AMP
Q1, T2
POWER
CONTROL
Q2
TX VCO
Q5, T6, DV1
VC1
10.7MHz 455kHz
RF FILTER
CF1, CF2
RF IC
MIX 1/2
PLL OSC
DC 5V
IC1
RF
-DATA
-CLK
-STB
EXP
COM
X2
17
14
TELEPHONE LINE
INTERFACE
·• TEL LINE
TEL
LINE
AMP
Q11, IC3
POWER SUPPLY
RESET CHARGE
5V
REGULATOR
Q18, Q19
RY1
SW
·• LINE
SEIZURE
Q10
DIODE
BRIDGE
D2, D3,
D4, D5
DC IN
12V 150mA
(AC Adaptor)
AC DOWN
DTC
Q8
TEL LINE
DC 5V
CONTROL LINE
AUDIO SIGNAL
LED
Q21, LED1
VTX RF
TX
DATA
-DATA
-CLK
-STB
RX
DATA
CPU
IC2
RESET
DTC
Q9
CHARGE
DTC
Q7
CHARGE
CONTROL
Q14, Q17
DC 12V
CHARGE
TERMINAL
KX-TC1205RUB/W/S/F BLOCK DIAGRAM (BASE UNIT)
Page 37
15 BLOCK DIAGRAM (HANDSET)
37
Base
DUPLEXER
DPX1
RX LOOP
TX LOOP
RF AMP
Q5, T5
ANTENNA
X1
RX VCO
L6, C24
RF AMP
Q1, T3
POWER
CONTROL
Q4
TX VCO
Q6, T6, DV1
VC1
MIX 1/2
PLL OSC
DC 3.9V
RF FILTER
CF1, CF2
RF IC
IC1
RF
-DATA
-CLK
-STB
EXP
COM
X3
SPEAKER
REC1
MIC
MC1
DIODE
BRIDGE
Q9
DC 3.9V
CONTROL LINE
AUDIO SIGNAL
BATTERY
3.9V
LED
Q8, LED 1-4
KEY BOARD
VTX
TX
DATA
RF
-DATA
-CLK
-STB
DATA
CPU
IC2
RX
RESET
Q11
CHARGE
DTC
IC2 PING37
BUZZER
Q7, BZ1
KX-TC1205RUB/W/S/F BLOCK DIAGRAM (HANDSET)
DIODE
BRIDGE
D1
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
CHARGE
TERMINAL
Page 38
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
16 CIRCUIT OPERATION
16.1. Outline
Base unit consists of the following ICs as shown in BLOCK DIAGRAM.
• • CPU:IC2
− − Controlling the whole system
− − Forming/analyzing all data signals (ACK, CMD signal etc.*)
− − All interfaces (ex: LED, KEY, SP, Mic, LCD, Detector Circuit (Charge/ Power Down)
*Refer to EXPLANATION OF CPU DATA COMMUNICATION (P.32).
• • RF IC:IC1
− − PLL Oscillator
− − Detection
− − Compress/ Expander
− − first/ second mixer
− − Amplifier for transmission and reception
• • Additionally,
− − Power Supply Circuit
− − Reset Circuit
− − Charge Circuit
− − Telephone Line Interface Circuit
Handset consist of the following ICs as shown in BLOCK DIAGRAM.
• • CPU: IC2
− − All data signals (forming/analyzing ACK or CMD signal*)
− − All interfaces (ex; LED, Key, Buzzer, Detector Circuit, Charge, Battery Low)
− − RAM for keeping the data (CH Number, ID Code, etc.)
• • RF IC:IC1
− − PLL Oscillator
− − Detector
− − Compress/Expander
− − first, second mixer
− − Amplifier for transmission and reception
*Refer to EXPLANATION OF CPU DATA COMMUNICATION (P.32).
38
Page 39
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
16.2. Power Supply Circuit
The power supply to the CPU (Digital, Analog) and RF IC from AC Adaptor (+12V) is shown in the diagram below.
The base unit power supply is DC12V. The handset´s power is supplied from 3.6V battery (Nickel-Cadmium battery) which is
installed in the handset.
Power supply for transmitter is turned on by a press of "Talk" key on the handset. During the stand-by mode, the unit stops
transmitting but receive thhe signal.
Also during on-hook condition (the handset is placed on the base unit), backup power for memory of the last dialed number is
supplied through the battery (3.6V nickel-cadmium in the handset). The memory of this unit is not backed up by the curreent
from the telephone line.
The base unit DC power supply is regulated by Q18, the CPU power is regulated by Q19. The Q8, detects AC Adaptor
powerfailure and maintains the unit cecutiry cord;
Fig. 1
39
Page 40
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
16.3. Reset Circuit (Base Unit)
After power supply from AC adaptor, the VREG is input for making reset signal. Refer to the below waveform.
Fig. 2
Fig. 3
40
Page 41
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
16.4. Charge Circuit
Circuit Operation:
When charging the handset on the base unit, the charge current is as follows;
DC (JK2) → L8 → D6 → L7 → CHG+(Base) → [CHG+(Handset) → L4 → Q9 → BATT(1)....Battery....BATT(2) → L5 →
CHG-(Handset)] → CHG+(Base) → L5,
In this way, the CPU on both unit detects the fact that the battery is charged.
The charge current is controlled by switching Q701 of Handset. The battery is charged in normal mode for 10 hours and then
in trickle mode.
16.5. Telephone Line Interface
Function:
• • Bell signal detection
• • ON/OFF hook and pulse dial circuit
• • Side tone circuit
Bell signal detection and OFF HOOK circuit:
In the idle mode, Q103 is open to cut the DC loop current and decrease the ring load. When ring voltage appears at the Tip (T)
and Ring (R) leads (when the telephone rings), the AC ring volltage is transferred as follows.
JK1 (3): T → L6 → R144 → IC3D (12,13 → 14) → C97 → R148 → Q20 → IC2 (24) [BELL ]
JK1 (2): R → L4 → R120 → R152 →↑
When the CPU (DSP) detects a ring signal and press the TALK Key on the handset. Q6 turns on and then RY1 turns on, thus
providing an off-hook condition (active DC current flow through the circuit) and the following singal flow is for the loop current.
T → R160 → L4 → RY1 → R107 → T7 → R116 → D5 → L6 → R161 → R[OFF HOOK]
ON HOOK Circuit:
Q6 is open, RY1 disconnected as to cut the DC loop current and to cut the voice signal. The unit is consequently in an on-hook
condition.
Pulse Dial Circuit:
DSP (Relay) turns RY1 ON/OFF to make the pulse dialing via Q6.
Make/Break ratio when dialing with the Handset: 40%:60%
Side Tone Circuit:
Basically this circuit prevents the TX signal from feeding back to RX signal.
As for this unit, TX signal feed back from Q11 is canceled by the cancellor circuit of AGC.
41
Page 42
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
16.6. Transmitter/Receiver
Base Unit and Handset are mainly consists of RF(Radio Frequency) IC and CPU.
Base Unit and Handset transmit/receive voice signal and data signal through the antenna on carrier frequency.
Signal Pass :
*Refer to CDL TX/RX in Signal Route (P.44).
16.6.1. Base to Handset
Circuit Operation:
The voice signal input from the TEL LINE interface goes to RF IC as shown in
BLOCK DIAGRAM (BASE UNIT) (P.36).
In the talk mode (off-hook) condition, the telephone line voice signal passes through D2, D3, D4, D5, RY1 (Relay), R107 and
T7.
The other party´s voice signal is coupled with T7 and amplified by Q11 and led to IC3-B (OP Amplifier device).
And the signal goes through the compressor of RF IC, it is output to transmitter circuit.
The signal of the data sent to the handset is applied in the anode of the variable capacitor diode (VARICAP : DV1).
The capacitor of VARICAP is changing inaccordance with the voice signal from telephone line interface or TXDATA signal from
CPU.
Therefore, the carrier frequency which is generated by TXVCO will be changing, and Frequency modulated RF signal is
generated and amplified by RF AMP(Q3, Q4, T5).
It pass through the Duplexer DPX1 and radiated from Antenna.
The signal is transmitted from the base unit and received by the handset antenna and amplified by RF amplifier (Q1) through
DPX1 as shown in BLOCK DIAGRAM (HANDSET) (P.37). And then it is converted to 10.7 MHz and 450 KHz Intermediate
frequency by RF IC and related components.
The demodulated audio signal is output from RF IC (DET OUT) and passed through "Expander" process to reduce noise, then
voice signal amplified by "Receiver amplifier" is output to receiver (REC1).
The receiver loudness is adjustable using "LOUD" key on the handset. Q2 and Q3 control the volume. When CPU (VOL1)
becomes low, the volume becomes “MID”, while CPU (VOL 1,2) becomes low, the volume becomes "HIGH".
TX data (to Handset)
CPU (VTX) becomes low to turn on the transmission power transistor Q2, and CPU (TX-data) sends data signal. It is FMmodulated by TXVCO and driven by RF AMP, then transmitted to the handset.
42
Page 43
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
16.6.2. Handset to Base
Circuit Operation:
The voice signal from the handset user is picked up by the microphone (MC1), voice signal passes through "Compressor"
process to reduce noise as shown in BLOCK DIAGRAM (HANDSET) (P.37). And the voice is FM-modulated by VARICAP
(DV1).
The carrier frequency is generated by TX VCO. The transmitter power transistor Q4 is turned on/off by CPU (VTX).
The carrier signal is amplified by RF AMP and sent to the handset duplexer and antenna.
The signal of 49MHz band (49.670~49.99MHz) which is input from ANT is filtered at DPX1 as shown in
BLOCK DIAGRAM (BASE UNIT) (P.36), then it is input to RF IC.
The signal input to RF IC is converted through Mixer inside of RF IC, RF filter (CF1, CF2) and Expander.
The signal is transmitted from the handset and received by the base unit antenna and amplified by RF amplifier Q1, then it is
converted to10.7 MHz and 450 KHz Intermediate by RF IC. The demodulated audio signal is output from RF IC (DET OUT) and
passed through "Expander" process to reduce noise, then voice signal is led to LINE AMP.
The signal is passed through TELEPHONE INTERFACE and Tel-line.
RX data (from Handset):
The data signal from handset (ex: Talk, ACK, COM) is also included in 49 MHz band same as the voice data. After second if
filter, the data signal is made square shape by data limiting AMP of the RF IC. RX data is output to CPU (RX Data).
16.6.3. RF signal operation/control and PLL operation (RF UNIT)
Base unit radio frequency signal received by antenna passes through duplexer (DPX1). RF signal is amplified by RF AMP.
RF signal received from RF IC is mixed with RX local frequency at Mixer to generate 10.7 MHz wide band IF. The reference
frequency is generated by X1 11.15 MHz crystal.
VC1 is the reference frequency for adjustment. The 10.7 MHz is mixed with reference and 450KHz narrow band IF is generated.
The demodulation audio signal is adjusted to the maximum at T1.
RF IC is controlled by CPU (RF_STB, DATA, CLK). The RX local frequency is generated by RXVCO.
43
Page 44
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
16.7. Signal Route
Each signal route is as follows.
44
Page 45
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
17 CIRCUIT OPERATION (HANDSET)
17.1. Reset Circuit (Handset)
The power of handset is supplied by battery.
Whenever the battery is recharged or inserted, the impulse at CHG+ becomes Reset signal through Q11, and sent to CPU.
Fig. 4
Fig. 5
45
Page 46
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
17.2. Battery Low / Power Down Detector
Circuit Operation:
“Battery Low” and “Power Down” are detected by RF IC which check the voltage from battery. Shortly, every detected blocks
are inside of RF IC. The detected voltage is as follows;
• • Battery Low
Battery voltage : V(Batt) < 3.57V
The CPU detects this level and “Recharge battery” LED starts flashing.
• • Power Down
Battery voltage : V(Batt) < 3.3V
The output of RF IC (P-DOWN) becomes low level, then CPU stops working to keep the data (CH number, ID Code, etc.)
Fig. 6
46
Page 47
18 CP U DATA (Base Unit)
18.1. IC2
KX-TC1205RUB / KX-TC1205RU W / KX-TC 1205RUS / KX- TC1205RUF
47
Page 48
KX-TC1205RUB / KX-TC1205RU W / KX-TC 1205RUS / KX- TC1205RUF
19 CP U DATA (Handset)
19.1. IC2
48
Page 49
20 HOW TO REPLACE FLAT
PACKAGE IC
20.1. Preparation
• • SOLDER
Sparkle Solder 115A-1, 115B-1 or Almit Solder KR-19, KR-
19RMA
• • Soldering iron
Recommended power consumption will be between 30 W
to 40 W.
Temperature of Copper Rod 662 ± 50°F (350 ± 10°C)
(An expert may handle between 60 W to 80 W iron, but
beginner might damage foil by overheating.)
• • Flux
HI115 Specific gravity 0.863.
(Original flux will be replaced daily.)
20.2. Procedure
1. Temporary fix FLAT PACKAGE IC by soldering on two
marked 2 pins.
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
20.3. Modification Procedure of
Bridge
1. Re-solder slightly on bridged portion.
2. Remove remained solder along pins employing soldering
iron as shown in below figure.
*Most important matter is accurate setting
of IC to the corresponding soldering foil.
2. Apply flux for all pins of FLAT PACKAGE IC.
3. Solder employing specified solder to direction of arrow, as
sliding the soldering iron.
49
Page 50
KX-TC1205RUB / KX-TC1205RU W / KX-TC 1205R US / KX-TC1205RUF
21 CABINET AND ELECTRICAL PARTS LOCATION (BASE
UNIT)
50
Page 51
KX-TC1205RUB / KX-TC1205RU W / KX-TC 1205R US / KX-TC1205RUF
22 CABINET AND ELECTRICAL PARTS LOCATION
(HANDET)
51
Page 52
KX-TC1205RUB / KX-TC1205RU W / KX-TC 1205R US / KX-TC1205RUF
23 ACCESSORIES AND PACKING MATERIALS
52
Page 53
24 REPLACEMEN T PARTS
LIST
Note:
1. RTL (Retention Time Limited)
The marking (RTL) indicates that the Retention Time is
limited for this item.
After the discontinuation of this assembly in production, the
item will continue to be available for a specific period of
time. The retention period of availability depends on the
type of assembly and the laws governing parts and product
retention.
At the end of this period, the assembly will no longer be
available.
2. Important safety notice
Components identified by the
characteristics important for safety. When replacing any of
these components, only use specified manufacture´s parts.
3. The S mark means the part is one of some identical parts.
For that reason, it may be different from the installed part.
4. RESISTORS & CAPACITORS
Unless otherwise specified;
All resistors are in ohms (Ω) K=1000Ω, M=1000kΩ
All capacitors are in MICRO FARADS (µF) P=µµF
*Type & Wattage of Resistor
24.1. Base Unit
24.1.1. CABINET AND ELECTRICAL
PARTS
Ref.
No.
1 PQJT10180Z CHARGE TERMINAL
2 PQHR10882Z LED LENS
3 PQGT15032Z NAME LABEL (for KX-TC1205RUB)
3 PQGT14900Z NAME LABEL (for KX-TC1205RUW)
3 PQGT14901Z NAME LABEL (for KX-TC1205RUS)
3 PQGT14902Z NAME LABEL (for KX-TC1205RUF)
4 PQQT22474Z CHARGE LABEL
5 PQBC10349Z1 PUSH BUTTON (for KX-
Part No. Part Name & Description Remarks
TC1205RUB)
mark indicates special
S
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
Ref.
No.
5 PQBC10349Z3 PUSH BUTTON (for KX-
5 PQBC10349Z2 PUSH BUTTON (for KX-
6 PQKE10335Z1 HOOK LEVER (for KX-TC1205RUB) S
6 PQKE10335Z5 HOOK LEVER (for KX-TC1205RUW) S
6 PQKE10335Z4 HOOK LEVER (for KX-TC1205RUS) S
6 PQKE10335Z2 HOOK LEVER (for KX-TC1205RUF) S
7 PQKF10534Y1 LOWER CABINET (for KX-
7 PQKF10534Y3 LOWER CABINET (for KX-
7 PQKF10534Y2 LOWER CABINET (for KX-
8 PQKM10509W1 UPPER CABINET (for KX-
8 PQKM10509W4 UPPER CABINET (for KX-
8 PQKM10509W3 UPPER CABINET (for KX-
8 PQKM10509W2 UPPER CABINET (for KX-
9 PQSA10104Y ANTENNA
10 XXLABALACE1 HOOK LABEL (for KX-TC1205RUB)
10 XXLASILUER1 HOOK LABEL (for KX-
Part No. Part Name & Description Remarks
TC1205RUW)
TC1205RUS/KX-TC1205RUF)
TC1205RUB/KX-TC1205RUF)
TC1205RUW)
TC1205RUS)
TC1205RUB)
TC1205RUW)
TC1205RUS)
TC1205RUF)
TC1205RUW/KX-TC1205RUS/KXTC1205RUF)
24.1.2. MAIN P.C.BOARD PARTS
Ref.
No.
PCB1 PQWPC1205RUH MAIN P.C.BOARD ASS´Y (RTL)
IC1 SA133122409 IC
IC2 SA138740577 IC
IC3 SA110032403 IC
IC4 AN6183S IC
Q1 BB230024104 TRANSISTOR(SI)
Q2 SB010390608 TRANSISTOR(SI)
Q3 SB110390405 TRANSISTOR(SI)
Q4 SB110390405 TRANSISTOR(SI)
Q5 SB110390405 TRANSISTOR(SI)
Q6 SB110390405 TRANSISTOR(SI)
Q7 SB110390405 TRANSISTOR(SI)
Q8 SB110390405 TRANSISTOR(SI)
Q9 SB110390405 TRANSISTOR(SI)
Q10 BB010009408 TRANSISTOR(SI)
Q11 SB110390405 TRANSISTOR(SI)
Q14 SB010390608 TRANSISTOR(SI)
Q16 SB110390405 TRANSISTOR(SI)
Q17 SB110390405 TRANSISTOR(SI)
Q18 BB1G0390403 TRANSISTOR(SI)
Q19 BB1G0390403 TRANSISTOR(SI)
Q20 SB110390405 TRANSISTOR(SI)
Q21 SB110390405 TRANSISTOR(SI)
D1 SC15L414808 DIODE(SI)
D2 BC2G0400400 DIODE(SI)
D3 BC2G0400400 DIODE(SI)
D4 BC2G0400400 DIODE(SI)
D5 BC2G0400400 DIODE(SI)
D6 BC2G0400400 DIODE(SI)
D9 SC15L414808 DIODE(SI)
D10 SC15L414808 DIODE(SI)
DV1 BC6K0025101 DIODE(SI)
ZD1 BC050474801 DIODE(SI)
ZD2 BC050474801 DIODE(SI)
ZD3 SC4555C4V71 DIODE(SI)
ZD5 SC4555C4V71 DIODE(SI)
ZD6 BC2G0400400 DIODE(SI)
ZD7 BC4579C2702 DIODE(SI)
ZD8 BC4579C5V65 DIODE(SI)
ZD10 SC4555C1506 DIODE(SI)
Part No. Part Name & Description Remarks
(ICS)
(TRANSISTORS)
(DIODES)
S
S
S
S
S
S
S
S
S
53
Page 54
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
Ref.
No.
ZD11 SV110201203 DIODE(SI)
ZNR1 VA107D271K1 DIODE(SI)
L1 PQLQZK2R2J COIL
L4 PQLQZK120J COIL
L5 PQLQZK120J COIL
L6 PQLQZK120J COIL
L7 PQLQZK120J COIL
L10 PQLQZK120J COIL
L12 SH4Y0750K46 COIL
JK1 DC72P120018 JACK/SOCKET
JK2 DC71P120023 JACK/SOCKET
CF1 BDFL107MA53 CERAMIC FILTER
CF2 BDFL0455E02 CERAMIC FILTER
DPX1 BDFL0083004 CERAMIC FILTER
X1 BD1R1024504 CRYSTAL OSCILLATOR
X2 BDRR0800005 CRYSTAL OSCILLATOR
T1 CLIP1200053 TRANSFORMER
T2 CLIP1200100 TRANSFORMER
T5 CLIP1200096 TRANSFORMER
T6 CLIP1200142 TRANSFORMER
T7 DG0P1200035 TRANSFORMER
D7 PQVDDSP272M VARISTOR
IC5 PQVIPC817K PHOTO ELECTRIC TRANSDUCER
LED1 SC5E0192115 LED
RY1 DCR000105H7 RELAY
SW1 DETP1200017 PUSH SWITCH
VC1 CR00020RRT5 TRIMMER CAPACITOR
R1 ERJ3GEYJ470 47
R2 ERJ3GEYJ330 33
R3 ERJ3GEYJ153 15k
R4 ERJ3GEYJ822 8.2k
R5 ERJ3GEYJ103 10k
R6 ERJ3GEYJ103 10k
R7 ERJ3GEYJ334 330k
R8 ERJ3GEYJ103 10k
R10 ERJ3GEYJ393 39k
R11 ERJ3GEYJ102 1k
R12 ERJ3GEYJ101 100
R13 ERJ3GEYJ623 62k
R14 ERJ3GEYJ103 10k
R15 ERJ3GEYJ562 5.6k
R16 ERJ3GEYJ153 15k
R17 ERJ3GEY0R00 0
R18 ERJ3GEYJ472 4.7k
R19 ERJ3GEYJ124 120k
R20 ERJ3GEYJ475 4.7M
R21 ERJ3GEYJ473 47k
R22 ERJ3GEYJ472 4.7k
R23 ERJ3GEYJ563 56k
R24 ERJ3GEYJ103 10k
R25 ERJ3GEYJ683 68k
R26 ERJ3GEYJ473 47k
R27 PQ4R10XJ560 56 S
R29 ERJ3GEY0R00 0
R30 ERJ3GEYJ104 100k
R31 ERJ3GEYJ473 47k
R32 ERJ3GEYJ105 1M
R33 ERJ3GEY0R00 0
R35 ERJ3GEYJ101 100
R36 ERJ3GEYJ224 220k
R37 ERJ3GEYJ101 100
R38 ERJ3GEYJ823 82k
R40 ERJ3GEYJ223 22k
R41 ERJ3GEYJ473 47k
R42 ERJ3GEYJ103 10k
R43 ERJ3GEYJ393 39k
Part No. Part Name & Description Remarks
(COILS)
(CONNRCTORS)
(CERAMIC FILTERS)
(CRYSTAL OSCILLATORS)
(TRANSFORMERS)
(OTHERS)
(RESISTORS)
Ref.
No.
R44 ERJ3GEYJ104 100k
R45 ERJ3GEYJ334 330k
R46 ERJ3GEYJ222 2.2k
R48 ERJ3GEYJ223 22k
R49 ERJ3GEYJ473 47k
R50 ERJ3GEYJ822 8.2k
R51 ERJ3GEYJ182 1.8k
R52 ERJ3GEYJ225 2.2M
R53 ERJ3GEYJ153 15k
R55 ERJ3GEYJ681 680
R56 ERJ3GEYJ222 2.2k
R57 ERJ3GEYJ224 220k
R58 ERJ3GEYJ511 510
R59 ERJ3GEYJ104 100k
R60 ERJ3GEYJ223 22k
R61 ERJ3GEYJ224 220k
R63 ERJ3GEYJ104 100k
R64 ERDS2TJ103 10k
R68 ERJ3GEYJ104 100k
R74 ERJ3GEY0R00 0
R75 ERJ3GEYJ103 10k
R77 ERJ3GEYJ203 20k
R78 ERJ3GEYJ393 39k
R79 ERJ3GEYJ823 82k
R80 ERJ3GEYJ222 2.2k
R81 ERJ3GEYJ164 160k
R82 ERJ3GEYJ103 10k
R83 ERJ3GEYJ103 10k
R84 ERJ3GEYJ103 10k
R85 ERJ3GEYJ103 10k
R86 ERJ3GEYJ473 47k
R87 ERJ3GEYJ102 1k
R88 ERJ3GEYJ103 10k
R89 ERJ3GEYJ103 10k
R90 ERJ3GEYJ304 300k
R91 ERJ3GEYJ154 150k
R92 ERJ3GEYJ103 10k
R93 ERJ3GEYJ104 100k
R95 ERJ3GEYJ392 3.9k
R96 ERJ3GEYJ274 270k
R97 ERJ3GEYJ822 8.2k
R98 ERJ3GEYJ123 12k
R99 ERJ3GEYJ823 82k
R100 ERJ3GEYJ104 100k
R103 ERJ3GEYJ223 22k
R104 ERJ3GEYJ472 4.7k
R105 ERJ3GEYJ472 4.7k
R106 ERDS2TJ220 22
R107 CQ63110RJ21 110
R108 ERJ3GEYJ472 4.7k
R109 ERJ3GEYJ334 330k
R110 ERJ3GEYJ104 100k
R111 ERJ3GEYJ471 470
R112 ERJ3GEYJ102 1k
R113 ERDST1TJ330 33
R114 ERJ3GEYJ223 22k
R115 ERJ3GEYJ563 56k
R116 ERJ3GEY0R00 0
R117 ERJ3GEYJ394 390k
R118 ERDS1TJ150 15
R119 ERJ3GEYJ823 82k
R120 ERJ3GEY0R00 0
R122 ERJ3GEYJ132 1.3k
R123 ERJ3GEYJ153 15k
R126 ERJ3GEYJ621 620
R129 ERJ3GEYJ682 6.8k
R131 ERJ3GEYJ104 100k
R132 ERJ3GEYJ222 2.2k
R133 ERJ3GEYJ820 82
R134 ERJ3GEY0R00 0
R135 ERJ3GEYJ152 1.5k
R139 ERJ3GEYJ106 10M
R141 ERJ3GEYJ512 5.1k
Part No. Part Name & Description Remarks
54
Page 55
Ref.
No.
R142 ERDS2TJ220 22
R143 ERJ3GEYJ514 510k
R144 ERDS2TJ206 20M
R145 ERJ3GEYJ102 1k
R146 ERJ3GEYJ153 15k
R148 ERJ3GEYJ103 10k
R149 ERJ3GEYJ182 1.8k
R150 ERJ3GEYJ514 510k
R151 ERDST1TJ682 6.8k
R152 ERDS2TJ206 20M
R153 ERJ3GEYJ105 1M
R154 ERJ3GEY0R00 0
R155 ERJ3GEYJ470 47
R156 ERJ3GEYJ470 47
R159 ERJ3GEYJ104 100k
R160 PQ4R10XJ000 0 S
R161 PQ4R10XJ000 0 S
R166 ERJ3GEYJ470 47
R167 ERJ3GEYJ103 10k
R170 ERJ3GEYJ102 1k
R171 ERJ3GEYJ102 1k
R172 ERDS2TJ223 22k
R173 ERDS2TJ102 1k
R174 ERDS2TJ102 1k
R176 ERJ3GEY0R00 0
R180 ERJ3GEYJ563 56k
R181 ERJ3GEYJ330 33
R186 ERJ3GEYJ472 4.7k
R187 ERJ3GEYJ273 27k
R188 ERJ3GEYJ103 10k
R189 ERJ3GEYJ223 22k
R190 ERJ3GEYJ103 10k
R191 ERJ3GEYJ683 68k
R192 ERJ3GEYJ124 120k
R193 ERJ3GEYJ104 100k
R194 ERJ3GEY0R00 0
C1 ECEA1EK470 47 S
C2 ECUV1H473MDV 0.047 S
C4 ECUV1H103KBV 0.01
C6 ECUV1C104ZFV 0.1
C7 ECUV1H102KBV 0.001
C8 ECUV1C104ZFV 0.1
C9 ECUV1H471JCV 470p
C10 ECUV1H471JCV 470p
C11 ECUV1H473MDV 0.047 S
C12 ECUV1H103KBV 0.01 S
C15 ECEA1HU2R2 2.2
C16 ECUV1H270JCV 27p
C17 ECEA1AKA101 100
C18 ECUV1C473KBV 0.047
C19 ECUV1H102KBV 0.001
C20 ECEA1HKA2R2 2.2
C22 ECUV1H103KBV 0.01 S
C23 ECUV1H103KBV 0.01 S
C24 ECUV1E223ZFV 0.022
C25 ECUV1H822KBV 0.0082
C26 ECUV1H070DCV 7p S
C27 ECUV1H103KBV 0.01
C28 ECUV1C104KBV 0.1
C29 ECUV1C104KBV 0.1
C30 ECEA1HKA2R2 2.2
C31 ECUV1H103KBV 0.01
C32 ECEA1HU2R2 2.2
C33 ECUV1H101JCV 100p
C34 ECUV1H471JCV 470p
C35 ECUV1H180JCV 18p
C36 ECUV1H101JCV 100p
C37 ECUV1H151JCV 150p
C38 ECEA1HKS010 1 S
C39 ECUV1H103KBV 0.01 S
C40 ECUV1H270JCV 27p
C41 ECEA1EK470 47 S
Part No. Part Name & Description Remarks
(CAPACITORS)
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
Ref.
No.
C42 ECEA1HU2R2 2.2
C43 ECUV1C104ZFV 0.1
C44 ECUV1A105ZFV 1
C45 ECUV1H682KBV 0.0068
C46 ECUV1H102KBV 0.001
C47 ECUV1H103KBV 0.01 S
C48 ECUV1H223KBV 0.022 S
C49 ECUV1H103KBV 0.01 S
C50 ECEA1HU220 22 S
C51 ECUV1H103KBV 0.01 S
C52 ECUV1H223KBV 0.022 S
C53 ECUV1H120JCV 12p
C54 ECUV1H020CCV 2p
C55 ECUV1H103KBV 0.01 S
C56 ECUV1H180JCV 18p
C57 ECUV1H390JCV 39p
C58 ECUV1H682KBV 0.0068
C59 ECUV1H390JCV 39p
C60 ECUV1H180JCV 18p
C61 ECUV1C104ZFV 0.1
C62 ECUV1H390JCV 39p
C63 ECUV1H103KBV 0.01 S
C64 ECUV1C104ZFV 0.1
C65 ECUV1H220JCV 22p
C66 ECEA1AU101 100
C67 ECUV1H220JCV 22p
C68 ECEA1HKAR47 0.47
C69 ECUV1H271JCV 270p
C70 ECUV1H223KBV 0.022 S
C71 ECUV1C104ZFV 0.1
C72 ECUV1H223KBV 0.022 S
C73 ECUV1C104ZFV 0.1
C74 ECUV1C104ZFV 0.1
C75 ECUV1H223KBV 0.022 S
C76 CATZ681KC68 680p
C77 ECUV1H151JCV 150p
C78 ECEA1AU471 470
C79 ECUV1C104ZFV 0.1
C80 CATZ681KC68 680p
C81 CJB21004K00 1
C82 ECUV1C104ZFV 0.1
C85 ECUV1C683KBV 0.068
C86 ECUV1H103KBV 0.01 S
C88 ECUV1A105ZFV 1
C90 ECUV1C224KBV 0.22
C92 ECUV1C104KBV 0.1
C93 ECUV1H562KBV 0.0056
C94 ECEA1CK101 100 S
C95 CB114714205 470
C96 ECUV1H103KBV 0.01 S
C97 ECEA1HKA4R7 4.7
C98 ECEA1EU221 220
C99 ECUV1H103KBV 0.01 S
C100 CJB21004K00 1
C101 ECUV1H562KBV 0.0056
C102 ECEA1EU221 220
C103 ECEA1AU470 47
C104 ECUV1H390JCV 39p
C104 ECFD1C104KD 104
C105 ECEA1CKA100 10
C106 ECUV1A105ZFV 1
C107 ECUV1C104ZFV 0.1
C108 ECUV1C104KBV 0.1
C109 ECUV1H682KBV 0.0068
C110 ECUV1H470JCV 47p
C111 ECUV1H103KBV 0.01 S
C121 ECUV1H103KBV 0.01 S
C123 ECUV1C474ZFV 0.47
C124 ECUV1C224KBV 0.22
C125 ECUV1H100DCV 10p S
C126 ECUV1C224KBV 0.22
C127 ECEA1EK470 47 S
C128 ECUV1C104KBV 0.1
Part No. Part Name & Description Remarks
55
Page 56
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
Ref.
No.
C129 ECUV1C104ZFV 0.1
C130 ECEA1AKA101 100
C131 ECUV1C104KBV 0.1
C132 ECUV1C104KBV 0.1
C133 ECUV1H390JCV 39p
Part No. Part Name & Description Remarks
24.2. Handset
24.2.1. CABINET AND ELECTRICAL
PARTS
Ref.
No.
101 PQJT10182Z CHARGE TERMINAL
102 PQGT15033Z NAME LABEL (for KX-TC1205RUB)
102 PQGT14903Z NAME LABEL (for KX-TC1205RUW)
102 PQGT14904Z NAME LABEL (for KX-TC1205RUS)
102 PQGT14905Z NAME LABEL (for KX-TC1205RUF)
103 PQKF10535Y1 REAR CABINET (for KX-
103 PQKF10535Y5 REAR CABINET (for KX-
103 PQKF10535Y4 REAR CABINET (for KX-
103 PQKF10535Y2 REAR CABINET (for KX-
104 PQKK10124Z1 BATTERY COVER (for KX-
104 PQKK10124Z5 BATTERY COVER (for KX-
104 PQKK10124Z4 BATTERY COVER (for KX-
104 PQKK10124Z2 BATTERY COVER (for KX-
105 PQKM10510W1 FRONT CABINET (for KX-
105 PQKM10510W5 FRONT CABINET (for KX-
105 PQKM10510W4 FRONT CABINET (for KX-
105 PQKM10510W2 FRONT CABINET (for KX-
106 PQSA10084U ANTENNA (for KX-TC1205RUB/KX-
106 PQSA10084V ANTENNA (for KX-TC1205RUW/KX-
107 PQSX10191Z KEYBOARD SWITCH (for KX-
107 PQSX10191V KEYBOARD SWITCH (for KX-
107 PQSX10191W KEYBOARD SWITCH (for KX-
108 PQXA36ASVC BATTERY
109 FH1T1200011 CUSHION, URETHANE FORM
110 CG2P1200012 SPEAKER
111 FE4T1200019 SP NET
112 FH2T1200012 BUZZER SHEET
113 PQHR10896Z LIGHT PIPE
114 FE4T1200027 MIC NET
24.2.2. MAIN P.C.BOARD PARTS
Ref.
No.
PCB100 PQWPC1205RUR MAIN P.C.BOARD ASS´Y (RTL)
IC1 SA133122409 IC
IC2 SA138780731 IC
Q1 SB110390405 TRANSISTOR(SI)
Q2 SB110390405 TRANSISTOR(SI)
Q3 SB110390405 TRANSISTOR(SI)
Q4 SB010390608 TRANSISTOR(SI)
Q5 SB110390405 TRANSISTOR(SI)
Q6 SB110390405 TRANSISTOR(SI)
Part No. Part Name & Description Remarks
TC1205RUB)
TC1205RUW)
TC1205RUS)
TC1205RUF)
TC1205RUB)
TC1205RUW)
TC1205RUS)
TC1205RUF)
TC1205RUB)
TC1205RUW)
TC1205RUS)
TC1205RUF)
TC1205RUF)
TC1205RUS)
TC1205RUB/KX-TC1205RUF)
TC1205RUW)
TC1205RUS)
Part No. Part Name & Description Remarks
(ICS)
(TRANSISTORS)
Ref.
No.
Q7 SB010390608 TRANSISTOR(SI)
Q8 SB110390405 TRANSISTOR(SI)
Q9 SB110390405 TRANSISTOR(SI)
Q11 SB110390405 TRANSISTOR(SI)
D1 SC15L414808 DIODE(SI)
D2 SC15L414808 DIODE(SI)
D3 SC15L414808 DIODE(SI)
DV1 BC6K0025101 DIODE(SI)
ZD1 BC4579C1005 DIODE(SI)
ZD3 SC455C5V601 DIODE(SI)
LED1 SC5E0192115 LED
LED2 SC5E0192115 LED
LED3 SC5E0192115 LED
LED4 SC5E0192115 LED
LED5 SC5E0192115 LED
LED6 SC5E0192123 LED
S
S
S
S
S
S
S
S
S
S
S
S
L1 PQLQZKR68J COIL
L2 PQLQZM120K COIL
L3 PQLQZM120K COIL
L4 PQLQZK120J COIL
L5 PQLQZK120J COIL
L6 PQLQZK1R8J COIL
L7 SH590121N75 COIL
CF1 BDFL107MA53 CERAMIC FILTER
CF2 BDFL0455E02 CERAMIC FILTER
DPX1 BDFL0083012 CERAMIC FILTER
X1 BD5R1024501 CRYSTAL OSCILLATOR
X2 BD8R3276805 CRYSTAL OSCILLATOR
X3 BD1R0399202 CRYSTAL OSCILLATOR
T1 CLIP1200053 TRANSFORMER
T3 CLIP1200070 TRANSFORMER
T5 CLIP1200061 TRANSFORMER
T6 CLIP1200088 TRANSFORMER
E101 CK15HC12G10 RINGER
E102 CGAP1200019 MICROPHONE
E103 PQJT10183Z CHARGE CONTACT
BATT1 PQJP2D13Z CONNECTOR
VC1 CR00020RRT5 TRIMMER CAPACITOR
R1 ERJ3GEYJ331 330
R2 ERJ3GEYJ153 15k
R3 ERJ3GEYJ682 6.8k
R5 ERJ3GEYJ103 10k
R6 ERJ3GEYJ103 10k
R8 ERJ3GEYJ224 220k
R9 ERJ3GEYJ823 82k
R10 ERJ3GEYJ823 82k
R11 ERJ3GEYJ562 5.6k
R12 ERJ3GEYJ224 220k
R13 ERJ3GEYJ123 12k
R14 ERJ3GEYJ153 15k
R15 ERJ3GEY0R00 0
R16 ERJ3GEYJ103 10k
R17 ERJ3GEYJ512 5.1k
R18 ERJ3GEYJ103 10k
R19 ERJ3GEYJ472 4.7k
R20 ERJ3GEYJ182 1.8k
R21 ERJ3GEYJ823 82k
R22 ERJ3GEYJ472 4.7k
R23 ERJ3GEYJ473 47k
R24 ERJ3GEYJ472 4.7k
R25 ERJ3GEYJ563 56k
R26 ERJ3GEYJ103 10k
R28 ERJ3GEYJ124 120k
R29 ERJ3GEYJ682 6.8k
R30 ERJ3GEY0R00 0
Part No. Part Name & Description Remarks
(DIODES)
(LEDS)
(COILS)
(CERAMIC FILTERS)
(CRYSTAL OSCILLATORS)
(TRANSFORMERS)
(OTHERS)
(RESISTORS)
56
Page 57
Ref.
No.
R34 ERJ3GEYJ224 220k
R35 ERJ3GEYJ473 47k
R36 ERJ3GEYJ202 2k
R37 ERJ3GEYJ102 1k
R38 ERJ3GEY0R00 0
R39 ERJ3GEYJ224 220k
R40 ERJ3GEYJ330 33
R41 ERJ3GEYJ683 68k
R42 ERJ3GEYJ223 22k
R43 ERJ3GEYJ104 100k
R44 ERJ3GEYJ393 39k
R45 ERJ3GEYJ104 100k
R46 ERJ3GEYJ434 430k
R47 ERJ3GEYJ222 2.2k
R48 ERJ3GEYJ223 22k
R49 ERJ3GEYJ473 47k
R50 ERJ3GEYJ822 8.2k
R51 ERJ3GEYJ272 2.7k
R52 ERJ3GEYJ681 680
R53 ERJ3GEYJ820 82
R54 ERJ3GEYJ104 100k
R55 ERJ3GEYJ390 39
R56 ERJ3GEYJ222 2.2k
R57 ERJ3GEYJ332 3.3k
R58 ERJ3GEYJ470 47
R59 ERJ3GEYJ222 2.2k
R60 ERJ3GEYJ222 2.2k
R61 ERJ3GEYJ331 330
R62 ERJ3GEYJ222 2.2k
R63 ERJ3GEYJ103 10k
R64 ERJ3GEYJ103 10k
R65 ERJ3GEYJ331 330
R66 ERJ3GEYJ222 2.2k
R67 ERJ3GEYJ222 2.2k
R68 ERJ3GEYJ103 10k
R69 ERJ3GEYJ222 2.2k
R70 ERJ3GEYJ222 2.2k
R72 ERJ3GEYJ105 1M
R74 ERJ3GEYJ104 100k
R75 ERJ3GEYJ104 100k
R76 ERJ3GEYJ104 100k
R77 ERJ3GEYJ103 10k
R78 ERJ3GEYJ104 100k
R79 ERJ3GEYJ105 1M
R81 ERJ3GEYJ105 1M
R82 ERJ3GEY0R00 0
R83 ERJ3GEY0R00 0
R84 ERJ3GEYJ105 1M
R85 ERJ3GEYJ102 1k
R86 ERJ3GEYJ104 100k
R87 ERJ3GEYJ104 100k
R91 ERJ3GEY0R00 0
R93 ERJ3GEYJ103 10k
R94 ERJ3GEYJ334 330k
R95 ERJ3GEYJ393 39k
R96 ERJ3GEY0R00 0
R97 ERJ3GEYJ104 100k
R98 ERJ3GEYJ475 4.7M
R99 ERJ3GEYJ472 4.7k
R101 ERJ3GEY0R00 0
R103 ERJ3GEYJ105 1M
R105 ERJ3GEYJ103 10k
R106 ERJ3GEYJ151 150
R107 ERJ3GEYJ222 2.2k
R108 ERJ3GEYJ102 1k
R109 ERJ3GEYJ102 1k
R110 ERJ3GEYJ102 1k
R111 ERJ3GEYJ102 1k
R112 ERJ3GEYJ102 1k
C1 ECEA1EK470 47 S
C2 ECUV1H473MDV 0.047 S
C3 ECUV1H390JCV 39p
Part No. Part Name & Description Remarks
(CAPACITORS)
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
Ref.
No.
C4 ECUV1H270JCV 27p
C5 ECUV1C104ZFV 0.1
C6 ECUV1H102KBV 0.001
C7 ECUV1C104ZFV 0.1
C8 ECUV1H473MDV 0.047 S
C9 ECUV1H103KBV 0.01
C12 ECEA1HKA2R2 2.2
C13 ECUV1H270JCV 27p
C14 ECUV1H103KBV 0.01
C15 ECEA1CKA100 10
C16 ECUV1C473KBV 0.047
C17 ECUV1H102KBV 0.001
C18 ECEA1HKA2R2 2.2
C21 ECUV1H223KBV 0.022 S
C22 ECUV1H390JCV 39p
C23 ECUV1H102KBV 0.001
C24 ECUV1H220JCV 22p
C26 ECUV1H103KBV 0.01
C27 ECUV1C104KBV 0.1
C28 ECUV1H682KBV 0.0068
C29 ECEA1HKA2R2 2.2
C30 ECUV1C104KBV 0.1
C31 ECUV1H103KBV 0.01
C32 ECUV1C104KBV 0.1
C33 ECUV1C104KBV 0.1
C34 ECUV1H101JCV 100p
C35 ECUV1H681JCV 680p
C36 ECUV1H180JCV 18p
C37 ECEA1HKA010E 1
C38 ECUV1H101JCV 100p
C39 ECUV1H151JCV 150p
C40 ECUV1H103KBV 0.01 S
C41 ECUV1H220JCV 22p
C42 ECEA1EK470 47 S
C43 ECEA1HKA2R2 2.2
C44 ECUV1C105ZFV 1
C45 ECUV1C683KBV 0.068
C47 ECUV1H682KBV 0.0068
C48 ECEA1EK470 47 S
C49 ECUV1H223KBV 0.022 S
C50 ECUV1H103KBV 0.01 S
C51 ECEA1CKA100 10
C52 ECUV1H103KBV 0.01 S
C53 ECUV1H223KBV 0.022 S
C54 ECUV1H100DCV 10p S
C55 ECUV1H103KBV 0.01 S
C56 ECUV1H010CCV 1p
C57 ECUV1H150JCV 15p
C58 ECUV1H103KBV 0.01
C59 ECUV1H270JCV 27p
C60 ECUV1H270JCV 27p
C61 ECUV1C104ZFV 0.1
C62 ECUV1H560JCV 56p
C63 ECEA1CK101 100 S
C64 ECUV1H103KBV 0.01 S
C65 ECUV1H150JCV 15p
C66 ECUV1H150JCV 15p
C69 ECUV1C104ZFV 0.1
C70 ECUV1H330JCV 33p
C71 ECUV1H330JCV 33p
C72 ECUV1C104ZFV 0.1
C73 ECUV1C104ZFV 0.1
C74 ECUV1H473MDV 0.047 S
C75 ECUV1H103KBV 0.01
C76 ECUV1H471JCV 470p
C77 ECUV1H471JCV 470p
C78 ECUV1H103KBV 0.01
C79 ECUV1H103KBV 0.01
C80 ECUV1H103KBV 0.01
C84 ECUV1C104ZFV 0.1
C85 ECUV1C105ZFV 1
C86 ECUV1C104ZFV 0.1
C88 ECUV1C104ZFV 0.1
Part No. Part Name & Description Remarks
57
Page 58
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
Ref.
No.
R102 ECUV1H333KBV 0.033 S
Part No. Part Name & Description Remarks
24.3. ACCESSORIES AND PACKING
MATERIALS
Ref.
No.
A1 PQJA10075Z TEL CORD
A2 PQLV16CEZ AC ADAPTOR
A3 PQQX13178Z INSTRUCTION BOOK
A4 PQQW12509Z LEAFLET
P1 PQPP10090Z POLY BAG (for Base Unit)
P2 PQPP10091Z POLY BAG (for Handset)
P3 PQPP10092Z POLY BAG
P4 PQPK13522Z GIFT BOX
Part No. Part Name & Description Remarks
58
Page 59
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
25 FOR SCHEMATIC DIAGRAM
25.1. Base Unit (SCHEMATIC DIAGRAM (Base Unit))
1. DC voltage measurements are taken with an oscilloscope or a tester with a ground.
2. The schematic diagrams and circuit board may be modified at any time with the development of new technology.
Important Safety Notice:
Components identified by
any of these components, use only the manufacturer´s specified parts.
25.2. Handset (SCHEMATIC DIAGRAM (Handset))
1. DC voltage measurements are taken with an oscilloscope or a tester with a ground.
2. The schematic diagrams and circuit board may be modified at any time with the development of new technology.
mark have special characteristics important for safety. When replacing
59
Page 60
26 SCHEMATIC DIAGRAM (Base Unit)
26.1. Base Unit
VREG
R57
60
C106
105
C0603
EXPO
COMP
CHARGE--
TP
13V to 5V
While charging
ZD10
15V/0.5W
ZD7.5
CHARGE+
D7
2700V
JK1
CHAG-CNTL
PIN2
R131
R132
100K
2K2
R0603
R0603
ADAPTOR
120V AC
12VDC
200mA
JK2
JACK DC
Q7
SOT-23
TP
C63
220K
103
R0603
C0603
R76
NA
R0603
R97
8K2
R0603
C73
104
C0603
C107
104
C0603
L5
12uH
L10
L7
12uH
L10
R118
150 1/2W
R12.5
Q14
SOT-23
Q17
SOT-23
D6
D10B
L8
JUMPER
+
L10
L9
JUMPER
L10
470UF\25V
TP
TP
R58
510
R0603
LED1
CHARGE
LED
19-21VGC/
TR8 GREEN
R100
100K
R0603
ZD4
NA
ZD7.5
R125
NA
R0603
R142
22 1/4W
R10
C95
EC10\5
TP
SW1
PAGE
SW2P
Q8
SOT-23
R108
4K7
R0603
AGC
CIRCUIT
AGC1
AGC2
R59
100K
R0603
R64
10K 1/4W
R0603
TX DATA
R91 150K R0603
R98
12K
R0603
TP
TO-92\EBC
R111KR0603
+
C98
220uF
EC5\5
RF-CLK
R171
IC3B
SIP14
0V
C82
104
C0603
+
C105
100UF/10V
EC5/5
Q19
R0603
5
NA
C0603
Q13
NA
SOT-23
Q16
SOT-23
+
R60
22K
R0603
7
C84
1K
VB
+12V
-
6
C0603
C88
105
C0603
R145
1K
R0603
C99
103
C0603
TP
+5V
C0603
PMUTE
4 11
C79
104
C64
104
Q21
SOT-23
R92
10K
R0603
R0603
R121
NA
R0603
R157
NA
R0603
A
R134
R0603
VB
TO-92\EBC
0
Q18
VTX
R114
22K
R166
R0603
R167
10K
R0603
RINGDET
CR-DET
47
+
C102
220UF/25V
EC10/5
ZD8
ZD7.5
VCPU
C68
0.47uF/50V
EC5\5
R109
330K
R0603
VREG
+5V
C96
103
R0603
CHAG-CNTL
R87 1K
R0603
+
VREG
C77
150P
C0603
R159
100K
R0603
R80 2K2 R0603
R82 10K
R84 10K
R89 10K
R99
82K
R0603
TP
+
C94
100UF\10V
EC8\5
C89
NA
C0603
R158
NA
R0603
VREG
+
C78
470UF/10V
EC10/5
R115
56K
R0603
R141
RING DET
R0603
R0603
R0603
5K1
R0603
C75
223
C0603
Q20
SOT-23
ZD3
4V7
D\362
ZD5
4V7
D\362
Q11
SOT-23
R133
82
R0603
R122
1K3
R0603
+5V
VCC
RESET
CHG LD
PAGE
HOOK
VTX
CNDET
CHG D
TX D
P MUTE
CLOCK
Q9
SOT-23
R106
22 1/4W
R10
C83
NA
C0603
C92
104
C0603
R146
15K
R0603
TP
C124
224
C0603
KX-TC1205RUB / KX-TC1205RU W / KX-TC1205RUS / KX-TC1205RUF
R153
1M
R0603
7.952
XTAL\10
R10
C91
R144
20M 1/4W
R10
20M 1/4W
X2
R112
1K
R0603
+
1Vp-p
100uF/10V
EC10/5
C67
22P
C0603
R83 10K
RF-STB
R88 10K
R0603
D1
D\362
PMUTE
LIMITED CURRENT
ZD6
27V
ZD7.5
ZD7
27V
ZD7.5
R10
C66
+
R0603
1
R104
4K7
R0603
D2
D10B
D4
D10B
R127
NA
R10
RING
IMPEDENCE
R151
6K8/1W
R12.5
0V
4 11
+12V
D3
D10B
D5
D10B
R189
22K
R0603
MPC25\22
R68
100K
R0603
-
2
+
3
IC3A
SIP14
1U/250V
C100
300K
R0603
C69
270P
C0603
R128
NA
R10
C120
NA
C0603
C0603
R90
C121
103
VREG
C74
104
C0603
R0603
R120
R75 10K R0603
R77 20K R0603
R78 39K R0603
R79 82K R0603
R81 160K R0603
C72
223
C0603
R103
22K
R0603
L4
12uH
L10
C76
IC3 PIN7
C86
103
C0603
0V
9
10
R139
10M
R0603
VCPU
R96
270K
R0603
VREG
680P 500V
CC6\5
C80
680P 500V
CC6\5
R117
390K
R0603
-
+
IC3C
41 1
SIP14
+12V
R147
R0603
Q6
SOT-23
ZD9
NA
ZD7.5
R86
47K
R0603
C70
223
C0603
C111
R102
103
NA
R0603
R0603
FS1
JUMP 5MM
FUSE\12.5
R160
0
R0805
R161
0
R0805
L6
12uH
L10
R178
NA
R10
C126
D10
224
D\362
C0603
8
R186
R0603
4K7
D9
D\362
0
TP
TP
R179
NA
R0603
R0603
27K
R187
+
LINE JACK 4C
R162
NA
R0805
AGC1
C127
47UF
R163
NA
R0805
JK1
1
2
3
4
LINE\JK1
AGC2
R188
10K
R0603
L11
JUMP
4MM
RX DATA
RF-DATA
R95
3K9
R0603
R180
56K
R0603
ZNR1
270V
ZNR\7K
0
R135
0603
1.5K
C132
104
C0603
RING SELECT
AGC CIRCUIT
RX
TX
8MHz
C104
104
C0603
28
VDD
27
RST
26
P10
25
P11
24
P12
23
P13
22
P14
21
P15
20
P16
19
P17
18
P72
17
P73
16
P74
15
P75
C71
104
C0603
R105
4.7K
R0603
R181
330
R0603
C123
474
C0603
C85
683
C0603
R126
620
R0603
C90
224
C0603
R148
10K
R0603
IC2
DIP28
R0603
R111
470
XOUT
TEST
6
4
R129
6K8
R0603
XIN
P67
P66
P65
P64
P63
P62
P61
P60
P77
P76
VSS
5
R0603
0V
LB-0627
R0603
R123
15K
R149
1K8
R0603
T7
R143
510K
R0603
R119
82K
1
2
3
4
5
6
7
8
9
10
11
12
13
14
R61
220K
R0603
OSCO
OSCI
TEST
POW F
DTMF4
DTMF3
DTMF2
DTMF1
DTMF0
RXDATA
COUT1
STROBE
DATA
JUMP
4MM
1
2
3
+
4U7/50V
EC5\5
L3
C97
ZD1
22V/1W
ZD7.5
R62
NA
R0603
R107
110 2W
R15
C81 1U/250V
R113
33/1W
R12.5
R137
4K7
R0603
C93
562
C0603
14
IC3D
SIP14
R63
100K
R0603
R93
100K
R0603
R172
22K L10
ZD2
22V/1W
ZD7.5
MPC25/22
PULSE
DAIL
R116
R0603
Q12 TO-92\EBC
C87
NA
C0603
R138
4K7
R0603
+12V
4 11
+
-
0V
R150
510K
R0603
C101
562
C0603
R74
0
R0603
R94
NA
R0603
Q10
TO-92\EBC
12
13
C65
22P
C0603
R85
C108
104 R0603
RY1
500 OHM
RY1
R110
100K
R0603
0
R124
27 R0603
R130
27 R0603
R10
Q15
TO-92\EBC
10uF/100V
10K
R0603
VB
IC5
DIP4
EC5\5
R152
KX-TC1205RUB/W/S/F SCHEMATIC DIAGRAM (Base Unit)
Page 61
26.2. RF Unit (Base Unit)
ANT1
ANTENNA
PAD3
61
2.2uH
L7.5
1
ZD11
15V/0.5W
ZD7.5
TP
C5
NA
L1
C0603
TP
C14
NA
C0603
3
DPX1
0830
ANT
DUP\5P
GRX
GTXRXTX
425
L12
TP
750nH
L1206
C110
C104
47P
39P
R0603
C0603
C133
39P
C0603
C46
102
C0603
T5
1436
IFT\7
3
4
5
1
C0603
103
C0603
2
C53
12P
R175
NA
R0603
R28
NA
R0603
C47
47UF/10V
Q3
SOT-23\ECB
CH+
R29
0
R0603
Q1
TO-92\EBC
C23
103
C0603
C103
EC5/5
2
R0603
TP
R39
NA
R0603
R12
100
R0603
R15
5K6
+
R46
2K2
R0603
R27
56
R0603
3
1
C22
103
C0603
R16
15K
R0603
R1
47
R0603
VB
R41
47K
R0603
C55
103
C0603
4
T2
1437
IFT\7
6
C20
2U2/50V
EC5/5
C29
104
C0603
C6
104
C0603
TP
+
R34
NA
R0603
R47
NA
R0603
C31
103
C0603
R33
0
R0603
C42
2U2 50V
EC5/5
C60
18P
C0603
C27
103
C0603
R22
4K7
R0603
C19
102
C0603
L10
1.2uH
L10
C49
103
C0603
Q4
SOT-23\
ECB
R0603
+
R17
0
C39
103
C0603
C26
7P
C0603
R35
100
R0603
R55
680
R0603
R0603
C17
10U/16V
EC5/5
+
2.1V
R14
10K
+
2U2/50V
EC5/5
0V
C125
10P
C0603
47U/10V
EC5/5
R42
10K
R0603
R53
15K
R0603
C30
C41
C56
18P
C0603
CF1 10.7MHZ
FILTER\1
1 3
R2
330
2
R0603
C7
102
C0603
C15
2U2/50V
EC5/5
IST
+
MIX
OUT
37
38
37
38
39
39
E-REC
VREF
40
40
IST Mix I N
41
41
VCC2
42
43
44
45
46
47
48
4.8V
10.7MHz
42
VCO CONT
43
VCO1
44
VCO2
45
C-RECT
46
RX CP
47
TX CP
PLL GND
48
VCC3 LO1 LO2 S-OUT CLK DATA STB FL-OUT
1
2
TX IN
123
+
C43
104
C0603
X1
11.15MHZ
XTAL\10A
R154
0
R0603
C54
2P
C0603
1 5
C11
473
C0603
34
35
36
35
36
N-REC 2ND
MIX
MIX
IN
OUT
3
4
4
5
C35
VC1
18P
20P
C0603
C0603
C40
27P
R30
100K
R0603
TP
R37
100
R0603
C51
103
C0603
Q5
SOT-23
R56
2K2
R0603
34
5
C2
473
C0603
CF2
450
FILTER\2
234
33
33
VCC1 2ND
4.4V
6
678
R173
1K
L10
C1
47UF/10V
EC5/5
+
31
32
31
32
IN
450kHz
IC1
7
8
C0603
C37
150P
R170
R174
1K
1K
R0603
L10
R43
39K
R0603
C59
39P
C0603
C62
39P
C0603
1431
IFT\7
C8
104
C0603
R156
47
TP
1 3
T1
GND2 DEC IF
R3
15K
R0603
C16
27P
C0603
27
28
29
30
30
27
28
29
QUAD IF
OUT
OUT
0V
COMP
FL-IN
OUT
9
10
R31
47K
R0603
10
R0603
11
11
EC5/5
1U/16V
R24
10K
R23
56K
R0603
C45
682
C0603
9
C34
470P
C0603
470P
C0603
R10
39K
R0603
26
26
C-NF
121314
121314
C38
+
C9
FIL-IN F OUT DET.
25
DATA I/P
DATA O/ P
RSSI
BAT. AL M
RO2
RO1
REC IN
EXP OUT
AF
OUT
C36
100P
C0603
R0603
R7
330K
R0603
470P
C0603
25
REF
OUT
REF
IN
R25
68K
R32
1M
R0603
C4
103
C0603
C10
AF-IN
R6
10K
R0603
24
24
23
23
22
22
21
21
20
20
19
19
18
18
17
17
16
16
15
15
R176
0
R0603
R0603
R5
10K
R0603
R8
10K
R0603
C12
C13
103
NA
C0603
C0603
C18
473
C0603
R13
C24
223
62K
C0603
R0603
R18
C32
4K7
2U2/50V
TP
+
C33
100P
C0603
C109
682
C0603
R26
47K
R0603
R155
47
R0603
EC5/5
R19
120K
R0603
R20
4M7
R0603
R0603
C44
105
C0603
R4
8K2
R0603
C131
R9
NA
R0603
IC4
4
3
2
R191
TP
TP
C25
822
C28
104
C0603
R21
47K
R0603
C0603
A
R190
10K
R0603
C128
104
C0603
TP
R0603
R194
R0603
1
68K
0
104
C0603
R192
120K
R0603
5
6
7
8
R193
100K
C130
R0603
10uF
C0603
C129
VREG
104
C0603
VERG
RX DATA
EXPO
COMP
RF-STB
RF-DATA
RF-CLK
CR-DET
VTX
TX DATA
GND
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
R40
22K
R0603
SOT-23
R48
22K
R0603
Q2
R36
220K
R0603
TP
C58
682
C0603
39P
C0603
R54
NA
R0603
C48
223
C0603
R0603
DV1
VCD2
C0603
C52
223
R49
47K
C61
104
C0603
R50
8K2
R0603
R44
100K
R0603
+
C50
22U/16V
EC5/5
C57
T6
1961
IFT\7
R38
82K
R0603
R51
1K8
R0603
R52
2M2
R0603
R45
330K
R0603
RX
TX
KX-TC1205RUB/W/S/F SCHEMATIC DIAGRAM (RF Unit (Base Unit))
Page 62
27 SCHEMATIC DIAGRAM (Handset)
27.1. Handset
+
C63
100uF/10V
EC4\2.5
MINI
R112 1K R0603
62
CHG+
10V 0.5W
D\362
CHG-
TX DATA
R72
R71
NA
R0603
R79
1M
R0603
TP
L4
H
12u
L7.5
C86
104
C0603
ZD3
ZD1
TP
L5
12uH
L7.5
5V6 0.5W
ZD7.5
TP TP
BATT1
3V6/300mA
CNT2P\2.5
2
1M
R0603
NA
R0603
1
R80
Q9
SOT-23
VBAT
D1
D\362
3.9V 0V
R73
NA
R0603
R81
1M
R0603
R85
1K
R0603
RSSI
R86
100K
R0603
C72
104
C0603
C69
104
C0603
ROW5
ROW4
ROW3
ROW2
ROW1
ROW0
0V to 5V
While charging
C73
104
C0603
C64
103
C0603
32.768kHz
R59 2K2 R0603
R60 2K2 R0603
R62 2K2 R0603
R66 2K2 R0603
R67 2K2 R0603
R69 2K2 R0603
R77 10K R0603
0V
0V
3.9V
R91(LOW BATT)
R87
100K
R0603
Q11
SOT-23
C74
473
C0603
3.5Vp-p
ALERT
CHARGE DE T
TX DATA
ROW5
ROW4
ROW3
ROW2
ROW1
ROW0
CR-DET
C65
15P
C0603
C66
15P
C0603
33
32
31
30
29
28
27
26
25
24
23
X2
32.768KHz
XTAL\2R
3435363738394041424344
P15
P16
P17
P20
P14
P13
P12
P11
P10
P51
IC2
P50
QFP-44P
P67
P66
P65
P64
P61
P62
P63
R83
0
R0603
0V
R104
NA
R0603
L2
12uH
L4
C67
NA
C0603
BUZ CNTL
R105 10K R0603
P77
P76
P75
P74
VDD
XTIN
P73
XTOUT
P72
P71
P70
P07
3.9V
P06
P05
P04
P03
P02
P01
P00
TEST
RESET
XIN
XOUT
VSSNCP60
1213141516171819202122
TES T
XOU T VDD
XIN
RESET
X3
4.0 MHZ
XTAL\10
C70
33P
C0603
L3
12uH
L4
3.9V to 0V
While charging
R111
1K
R0603
C68
NA
C0603
R57 3K3 R0603
R58 47 R0603
DATA
R63 10K R0603
1
CLOCK
R64 10K R0603
2
RX PWR
3
RX DATA
R68 10K R0603
4
BACKLED
R70 2K2 R0603
5
TALK LED
6
LOW LED
7
COL3
8
COL2
9
COL1
10
COL0
11
4MHz
R82 0
R0603
R84
1M
R0603
C71
33P
C0603
LED2 LED3
GREEN
LED\SQ
R53
82
R0603
LED4
GREEN
LED\SQ
R61 330
R0603
R65 330
R0603
R74 100K R0603
R75 100K R0603
R76 100K R0603
R78 100K R0603
LED5
LED6
TALK
RECHG
GREEN
LED\SQ
RED
LEC\SQ
C84
102
C0603
VOL1
VOL2
RF-STB
D2
D\362
R54
100K
R0603
R56
2K2
R0603
D3
D\362
R55
39
R0603
Q7
STO-23
TP
BZ1
BZ
BZ12
RF-DATA
RF-CLK
VTX
RX DATA
LED1
GREEN
LED\SQ
1
2
GREEN
LED\SQ
Q8
SOT-23
2Vp-p
K1 RINGER
1 2
K5 PROG
1 2
ROW5
K8 *
1 2
ROW4
K11 7
1 2
ROW3
K14 4
1 2
ROW2
K17 1
1 2
ROW1
K20 TALK
1 2
ROW0
L7 120 OHM COIL SMD R0805
1 2
1 2
1 2
1 2
1 2
TP TP
1 2
1 2
K2 FLASH
K6 PAUSE
K9 0
K12 8
K15 5
K18 2
K21 AUTO
K3 LOUD
1 2
K7 CH
1 2
K10 #
1 2
K13 9
1 2
K16 6
1 2
K19 3
1 2
K22 DIRT
1 2
K4 REDIAL
1 2
KP\RO\4.5C
KX-TC1205RUB/W/S/F SCHEMATIC DIAGRAM (Handset)
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
Page 63
27.2. RF Unit (Handset)
ANT1
ANTENNA
PAD3
TP
L1
0.68UH
L7.5
TP
3
ANT
GRX
GTXRXTX
425
1
TP
C0603
C22
39P
DPX1
DPX0830
DUP\25P
R10
82K
R0603
Q1
C5
104
C0603
T3
1440
IFT\7
2
SOT-23\EBC
TX
T5
1856
IFT\7
3
4
5
C3
39P
C0603
1
63
27P
C0603
C11
NA
C0603
C0603
1
3
R0603
2
C54
10P
R106
150
R0603
6
4
C88
104
C0603
R11
5K6
TP
Q5
SOT-23\EBC
R14
15K
R0603
R47
2K2
R0603
RX
C18
2.2U/50V
EC5/2.5
C27
104
C0603
TP
C50
103
C0603
+
C31
103
C0603
2U2/50V
R43
100K
R0603
C55
103
C0603
C26
103
C0603
R24
4K7
R0603
C43
EC5/2.5
C17
102
C0603
R97
100K
R0603
R0603
+
L6
1.8uH
L7.5
R15
0
C40
103
C0603
C60
27P
C0603
R38
0
R0603
C0603
C24
22P
C0603
C56
1P
C15
10U/16V
EC5/2.5
2.1V
+
+
C29
2.2U/50V
EC5/2.5
0V
C42
47U/10V
EC5/2.5
C6
102
C0603
+
36
37
36
37
MIX
IN
10.7MHz
3.9V
2
3
2
3
C36
18P
C0603
C0603
C41
22P
10U/16V
EC5/2.5
R1
330
R0603
C8
473
C0603
35
35
N-REC 2ND
MIX
OUT
4
456
VR8
VC1
20P
R34
220K
R0603
TP
C51
Q6
SOT-23\EBC
R52
680
R0603
1 5
34
34
5
R108
1K
R0603
+
CF1 10.7MHZ
FILTER\1
123
C12
2U2/50V
EC5/2.5
IST
MIX
OUT
38
38
39
39
E-REC
VREF
40
40
IST Mix IN
41
41
VCC2
42
42
VCO CONT
43
43
VCO1
44
44
VCO2
45
45
C-RECT
46
46
RX CP
47
47
TX CP
PLL GND
48
48
VCC3 LO1 LO2 S-OUT DATA STB FL-OUT
1
1
TX IN
C44
+
105
C0603
X1
10.245MHZ
XTAL\10A
R40
33
R0603
C2
C1
473
47UF/10V
C0603
EC5/2.5
C85
+
105
C0603
T1
1431
CF2
455E
FILTER\2
234
VCC1 2ND
IFT\7
C7
104
C0603
30
31
32
33
33
30
31
32
GND2 DEC IF
IN
3.9V 0V
450kHz
IC1
CLK
6
7
8
9
7
8
C0603
C39
150P
R110
R109
1K
1K
R0603
R0603
R44
39K
R0603
C57 15P
C59
C0603
27P
C0603
C62
56P
C0603
9
C35
680P
C0603
1 3
C0603
29
29
OUT
FL-IN
R0603
R35 47K
R0603
C52
103
C0603
C13
27P
QUAD IF
10
10
R26
10K
T6 1960
R0603
28
IFT\7
VBAT
TP
R93
10K
R0603
R2
15K
C76
470P
C0603
R95 39K
R0603
26
27
26
27
28
OUT
COMP
OUT
11
11
R25
56K
R0603
C47
682
C0603
FIL-IN F OUT DET.
C-NF
12
121314
+
C37
10U/16V
EC5/2.5
C49
223
C0603
C53
223
C0603
R49
47K
R0603
DV1
VCD2
25
25
DATA I/P
DATA O/P
RSSI
BAT. ALM
RO2
RO1
REC IN
EXP OUT
AF
OUT
13
R0603
C75
103
C0603
C77
470P
C0603
24
24
23
23
22
22
21
21
C23
102
20
20
C0603
19
19
C28
6800P
C0603
18
18
17
17
C32 104
C0603
REF
16
16
OUT
REF
15
IN
15
14
AF-IN
C38
100P
C0603
R28
120K
C87
N/A
C0603
R101 0 R0603
R45
100K
R0603
R50
8K2
R0603
C61
104
C0603
R94
330K
R0603
R29
6K8
R0603
R102
333
C34
100P
C0603
C79
103
C0603
C0603
R5
10K
R0603
C9
103
C0603
C0603
R0603
R6 10K
R0603
C16
473
R13
12K
R0603
R18
10K
R21
82K
R0603
R0603
C46
NA
C0603
RX
C78
103
C0603
R30
0
C20
NA
C0603
R16
10K
R0603
SOT-23\ECB
C0603
R41
68K
R0603
R51
2K7
R0603
C10
NA
C0603
R0603
Q3
C30
104
C0603
R20
1K8
C45
683
R7
NA
R0603
SOT-23\ECB
R36
2K
R0603
R98
4M7
R0603
R46
430K
R0603
TP
TP
R17
5K1
R0603
Q2
R103
1M
R0603
C48
47U/10V
EC5/2.5
R96
0
R0603
R23
47K
R0603
C80
103
C0603
REC1
SD153
SIP2
C33
104
C0603
+
R48
22K
R0603
R3
6K8
R0603
C14
103
C0603
R37
1K
R0603
R42
22K
R0603
TP
TP
C0603
R12
220K
R0603
R19
4K7
R0603
R91
R0603
0
R22
4K7
R0603
TP
MIC
TP
SOT-23\ECB
C58
103
C0603
R8
220K
R0603
R9
C21
82K
223
R0603
3.1V
(In Talk Mode)
MC1
Q4
R39
220K
R0603
R107
2K2
R0603
R99
4K7
R0603
TP
VOL1
VOL2
VB
RX DATA
RSSI
IC2-22
RF-STB
RF-DATA
RF-CLK
VTX
TXDATA
GND
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
TX
KX-TC1205RUB/W/S/F SCHEMATIC DIAGRAM (Handset (RF Unit))
Page 64
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
64
Page 65
28 CIRCUIT BOARD (Base Unit)
28.1. Component View
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
IC5
65
KX-TC1205RUB/W/S/F CIRCUIT BOARD (Component View (Base Unit))
Page 66
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
28.2. Flow Solder Side View
+12V
GND
TXPOWER
TXGND
TX DATA
(DV1)
RX-VCO
TX-VCO
2nd Mix
(RF IC: 36)
IC1
IF IN
(RF IC: 32)
T.P ( CH change at test mode)
R98: for Changing the channel
IC2
XOUT
(CPU: 1)
VDD (CPU: 28)
CHG LD
(CPU: 26)
DETOUT
(RF IC: 27)
RST
(CPU: 27)
RX DATA
(CPU: 10)
RX DATA
(RF IC: 23)
RING
TIP
CHG DET
(CPU: 18)
TX DATA
(CPU: 17)
IC3
IC4
RING DET
(CPU: 24)
66
KX-TC1205RUB/W/S/F CIRCUIT BOARD (Flow Solder Side View (Base Unit))
Page 67
29 CIRCUIT BOARD (Handset)
29.1. Component View
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
IC2
TX DATA
(DV1)
TX DATA
(CPU: 36)
67
VDD (CPU: 40)
(A) Battery Low
(G) Noise Squelch
KX-TC1205RUB/W/S/F CIRCUIT BOARD (Component View (Handset))
CHG DET
(CPU: 37)
Page 68
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
29.2. Flow Solder Side View
V Bat
(RF IC: 33)
IF IN
(RF IC: 32)
RX VCO
TX VCO
IC1
2nd Mix
(RF IC: 36)
TXPOWER
KX-TC1205RUB/W/S/F CIRCUIT BOARD (Flow Solder Side View (Handset))
TXGND
68
Page 69
KX-TC1205RUB / KX-TC1205RUW / KX-TC1205RUS / KX-TC1205RUF
69
I
KXTC1205RUB
KXTC1205RUW
KXTC1205RUS