Panasonic IMAGECHECKER A110, IMAGECHECKER A210, MICRO-IMAGECHECKER A210, MICRO-IMAGECHECKER A110 Installation Manual

MICRO-IMAGECHECKER
®
Image Processing Device
A210•A110
It wont stop advancing. The monstrously small A Series!
MICRO-IMAGECHECKER® A210•A110 MultiChecker V2 Series
Table of Product Numbers
System configuration diagram
Camera cable
Double-speed random camera cable
Camera extension cable
3 m 3 m: CE 2 m extension: total 5 m 7 m extension : total 10 m 12 m extension: total 15 m 17 m extension: total 20 m 2 m extension : total 5 m: CE 7 m extension: total 10 m: CE 12 m extension: total 15 m: CE 17 m extension: total 20 m: CE
ANM84303 ANM84303CE ANM84002 ANM84007 ANM84012 ANM84017 ANM84002CE ANM84007CE ANM84012CE ANM84017CE
Vision Backup-Tool Ver.2 English version
ANM70131V2
ANM8828 ANM88281 ANM8804 ANM88041 ANM8808 ANM88081 ANB842 ANB843 ANB843L ANB845N ANB845NL ANB846N ANB846NL ANB847 ANB847L ANM8850 ANM88501 ANB84805 ANB848
CS mount lens
C mount lens
Middle ring
f2.8 CS mount compact lens f2.8 CS mount compact lens with lock f4 CS mount compact lens f4 CS mount compact lens with lock f8 CS mount compact lens f8 CS mount compact lens with lock f6.5 C mount lens f8.5 C mount lens f8.5 C mount lens with lock f16 C mount compact lens f16 C mount compact lens with lock f25 C mount compact lens f25 C mount compact lens with lock f50 C mount lens f50 C mount lens with lock f50 C mount compact lens f50 C mount compact lens with lock 5 mm middle ring (0.5/1/5/10/20/40 mm) middle ring
Item
ANMA212V2 ANMA218V2
ANMA212
A210 Multi-Checker V2 : CE
A210 Multi-Checker : CE
A110 Multi-Checker V2 : CE
A110 Multi-Checker : CE
ANMA112V2 ANMA118V2
ANMA112
Specifications Part No.
NPN Output PhotoMos Output
NPN Output NPN Output
PhotoMos Output NPN Output
Part No.
Part No.
Part No.
Part No.
Item Specifications
Serial Cable
Lens / middle ring
Item Specifications
Data backup software
*1 The A100 series connects to one camera. *2 Use where necessary. *3 When using 2 cameras with the A200 series, connect the same type of camera.
Unless otherwise specified, estimate and delivery prices do not include technician dispatching and other related services. Therefore, for the situations given below, additional charges may be added.
Installation and trial operation guidance Inspections, adjustments, and repairs
Technical support and instruction
Item Specifications
I/O terminal block BNC connector
For input: 1 piece, for output, 1 piece Monitor BNC jack to PIN jack adapter
ANMA8001 ANM8606
Accessories
Item Specifications
To USA Customer
Products sold by seller are covered by the warranty and patent indemnification provisions in its Terms and Conditions of Sale only.
PC
ENTER
A
C
B
High-speed random trigger camera
High-speed random cable
Lens
Middle ring
CS mount camera
Keypad
Monitor
Camera extension cable
*2
*1
*3
Serial cable
Controller
PLC (refer to P5)
Panasonic
V-HOLD BLIGHT
CONTRAST
Video Monitor GP-BM
Microsoft windows NT4.0/95/98/Me/2000 compatible. An operating system is not included with this software.
MICRO-IMAGECHECKER
A100 Series
MICRO-IMAGECHECKER
A200 Series
Item
Progressive Double-speed Random: CE support electric-shutter with 3 m cable support electric-shutter with 3 m cable: CE with 2 m cable with 3 m cable with 2 m cable: CE with 3 m cable: CE Panasonic GPBM910 (100 V AC/12 V DC)
C mount camera CS mount camera
Keypad
Monitor
ANM831 ANM832 ANM832CE ANM85202
ANM85202CE ANM85203CE AUGPBM910
ANM85203
Specifications
Part No.
Monitor cable
(Pin-BNC)
However, it is not possible to directly restore type data backed up using Vision Backup-Tool with the previous product (Ver. 1) to V2 (Ver. 2). In this case, use the dedicated data conversion software (freeware) to convert the Ver. 1 type data for V2 use, then transfer it to V2 and perform a backup again. If you require the data conversion software, contact your Matsushita Automation Controls Co. Ltd. representative.
*
Vision Backup-Tool Ver.2
The product data created with the MICRO-IMAGECHECKER A series and the image data stored in the controller can be stored on a PC using Windows. Stored data can be restored to the A series controller.
COM port connecting cable
COM port and PC (D-SUB : 9 pin) connection, 3 m
Part No.Item
Specifications
COM port and PLC (discrete-wire cable) connection, 3 m
TOOL port connecting cable
COM port and PC (D-SUB : 9 pin) connection, 10 cm
ANM81103 ANM81303
ANM812001
MICRO-IMAGECHECKER A-Series Controller
Camera / Keypad / Monitor
These materials are printed on ECF pulp. These materials are printed with earth-friendly vegetable-based (soybean oil) ink.
COPYRIGHT © 2001 All Rights Reserved Specifications are subject to change without notice.
쮿
Head Office: 1048, Kadoma, Kadoma-shi, Osaka 571-8686, Japan
ARCT1B178E 200111-2YT
Matsushita Electric Works, Ltd.
Automation Controls Company
Type switching not required!
First field of vision
(Block 1)
Second field of vision
(Block 2)
Third field of vision
(Block 3)
3
Type 1
User-Defined Mode
New
New
Multiple inspections of up to three blocks with no switching time!
Conventional method
User-Defined Mode
Handled by type switching using an external device.
Type switching requires time and usage restrictions
apply.
Internally switches to the process block via an external signal.
External device is not used, so inspection time is greatly reduced! *Can be executed from the keypad as well.
When you wish to perform multiple continuous inspections because the work will not fit in the field of view of a single image capture.
Example
Type 2 Type 64
Execute All Mode
Three times the number of checkers can now be registered per type, so you can inspect many points at one time!
Multiple simultaneous point inspection possible for applications such as inspecting LED lighting.
Plenty of external outputs for judgment results (96 points for the A210 and 48 points for the A110) allow simultaneous output of judgment results for multiple inspection points.
Example
Branch inspection without complicated settings provides great convenience!
Conventional method
Automatic Switch Mode
Execute all checkers and output results
Perform direction judgment externally and compare results
Perform direction judgment and execute the required checker
Execute block 1
(5 msec)
Detect the direction judgment marker
Normal direction
Reverse direction
Execute Block 2
(30msec)
Execute Block 3
(30msec)
MICRO-IMAGECHECKER A210 and A110 Multichecker V2 (Photo shows A210)
It is possible to first make a direction judgment, and then perform a separate inspection (character appearance or mark width measurement) based on this direction.
Execution time: 65msec.
Execution time:
35msec!
Direction judgment
2
Example
Execution time
Execution time
reduced by half!
reduced by half!
Our highly acclaimed, compact A210 and A110 MultiChecker image processing units are now even more powerful! The V2 (Ver. 2) upgrade includes new functions for even greater convenience. To meet your diverse range of inspection requirements, we have increased the number of checkers by a factor of three. In addition to making more inspection locations possible, they now come equipped with a new mode that allows two-level branch inspection using one image checker, and an extensive range of functions that allow use in a wide range of applications.
You can now register three times more checkers per type!
A210 MultiChecker: increased from 32 to 96
A110 MultiChecker: increased from 16 to 48
Possible to choose from three execution modes to suit your
inspection requirements!
Automatic Switch Mode
The MultiChecker V2 Series - more powerful than ever!
Three times the processing capacity of their predecessors! Designed to meet a diverse variety of inspection needs!
Execution time
reduced by half!
Loading...
+ 4 hidden pages