NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET
HHR75AAA/B Cylindrical AAA size (HR 1 1/45)
Dimensions (with T ube) (mm)
+-0
10.5
0
(+)
+-0
44.5
1.0
( )
Specifications
mm inch
Diameter
Height
Approximate
Weight
10.5+0/-0.7
44.5+0/-1.0
Grams
12 0.42
0.41+0/-0.03
1.75+0/-0.04
Ounces
Typical Charge Characteristics
2.0
1.9
1.8
1.7
1.6
1.5
1.4
1.3
1.2
Voltage (V)
1.1
1.0
0.9
0.8
0 10 20 30 40 50 60 70 90 100 110 12
Charge Time (minutes)
Charge: 450mA (0.64 It) x 1.7hrs
80
Typical Discharge Characteristics
1.8
1.7
1.6
1.5
1.4
1.3
1.2
Voltage (V)
1.1
1.0
0.9
0.8
012345
Charge: 450mA (0.64It) x 1.7 hrs, 20˚C.
Discharge T emperature: 20˚C.
Discharge Time (hours)
20˚C
45˚C
140mA
(0.2It)
0˚C
Nominal V oltage 1.2V
Discharge
Capacity*
Average**
Rated (Min.)
Approx. Internal impedance
at 1000Hz at charged state.
Charge
Standard
Rapid
Charge
Standard
Rapid
Discharge
Ambient
Storage
Temperature
< 1 year
< 3 months
< 1 month
0˚C to 45˚C
0˚C to 40˚C
-10˚C to 65˚C
-20˚C to 35˚C
-20˚C to 45˚C
-20˚C to 55˚C
730 mAh
700 mAh
35mΩ
70mA x 16hrs.
450mA x 1.7 hrs.
C
˚
32˚F to 113˚F
32˚F to 104˚F
14˚F to 149˚F
-4˚F to 95˚F
-4˚F to 113˚F
-4˚F to 131˚F
F
˚
* After charging at 0.1It for 16 hours, discharging at 0.2It.
** For reference only.
Battery performance and cycle life are strongly affected by how they
are used. In order to maximize battery safety, please consult Panasonic
when determining charge / discharge specs, warning label contents
and unit design.
Note: [It] was previously expressed as [C]. [It] is an IEC standard expression
for the amount of charge or discharge current and is expressed as:
It(A) = Cn (Ah)/1h.
• [It] is the reference test current in ampres
• [Cn] is the rated capacity of the cell or battery in Ampere-hours.
n = the time base [hours] for which the rated capacity is declared
1.8
1.7
1.6
1.5
1.4
1.3
1.2
Voltage (V)
1.1
1.0
0.9
0.8
0 102030405060708
Charge: 450mA (0.64It) x 1.7hrs, 20˚C.
Discharge Temperature: 20˚C.
Discharge Time (hours)
700mA (1It)
1400mA (2It)
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to
modification without notice. Contact Panasonic for the latest information.
NICKEL METAL HYDRIDE HANDBOOK
AUGUST 2005