NICKEL METAL HYDRIDE BATTERIES: INDIVIDUAL DATA SHEET
HHR300CH Cylindrical C size (HR 26/50) for backup use
Dimensions (with T ube) (mm)
+
0
25.8
1
-
(+)
+
0
50.0
1.
-
( )
Specifications
Diameter
Height
Approximate
Weight
mm
25.8+0/-1.0
50.0+0/-1.5
Grams
80 2.82
inch
1.02+0/-0.04
1.97+0/-0.06
Ounces
Typical Charge Characteristics
2.0
1.8
1.6
1.4
Voltage (V)
1.2
1.0
0.8
0246810203040506
Charge Time (hours)
Charge: 300mA(0.1 It) x 16hrs.
Typical Discharge Characteristics
120
110
100
90
80
70
Charge: 300mA (0.1 It) x 16 hrs.
60
Charge Temperature: -10 to 60˚C
Capacity Ratio (%)
50
Discharge: 600mA (0.2 It)
Cut-off Voltage: 1.0V
40
Discharge Temperature: 25˚C
30
-20 -10 0 10 20 30 40 50 60 7
Temperature (°C)
10˚C
25˚C
60˚C
Nominal V oltage 1.2V
Discharge
Capacity
1
Average
Rated (Min.)
2
Approx. Internal impedance
at 1000Hz at charged state.
Standard
Charge
Rapid
3
Low Rate
Standard
Charge
Rapid
Low Rate
Discharge
Ambient
Temperature
Storage
1
After charging at 0.1It for 16 hours, discharging at 0.2It.
2
For reference only.
3
Need specially designed control system
Control System:
dT/dt cut-off; 1 to 2°C/min
-UV cut-off; -UV per cell = 5 to 10 mV
T-control; T=65°C
Rapid charger timer; 2.4h (at 1.25a)
Trickle timer; within 2h
4
With control system
Battery performance and cycle life are strongly affected by how they are used. In
order to maximize battery safety, please consult Panasonic when determining
charge / discharge specs, warning label contents and unit design.
< 1 year
< 3 months
< 1 month
0˚C to 45˚C
10˚C to 40˚C
-10˚C to 45˚C
-10˚C to 65˚C
-20˚C to 35˚C
-20˚C to 35˚C
-20˚C to 55˚C
3300 mAh
3100 mAh
5mΩ
300mA (0.1It) x 16hrs.
1500mA (1It) x 2.4 hrs.
155mA x 32 hrs.
C
˚
100mA x 48 hrs.
F
˚
32˚F to 113˚F
32˚F to 104˚F
14˚F to 149˚F
14˚F to 113˚F
-4˚F to 95˚F
-4˚F to 95˚F
-4˚F to 131˚F
4
1.8
1.6
1.4
1.2
Voltage (V)
1.0
0.8
0 5 10 15 20 25 3
Note: [It] was previously expressed as [C]. [It] is an IEC standard expression
for the amount of charge or discharge current and is expressed as:
It(A) = Cn (Ah)/1h.
• [It] is the reference test current in ampres
• [Cn] is the rated capacity of the cell or battery in Ampere-hours.
n = the time base [hours] for which the rated capacity is declared
Charge: 300mA(0.1It) x 16 hrs., 25°C
Discharge: 10A, 20A, 25°C
Discharge Time (minutes)
10A
20A
This information is generally descriptive only and is not intended to make or imply any representation, guarantee or warranty with respect to any cells and batteries. Cell and battery designs/specifications are subject to
modification without notice. Contact Panasonic for the latest information.
NICKEL METAL HYDRIDE HANDBOOK
AUGUST 2005