Panasonic FV-11VH2 User Manual

Page 1
Model No.
FV-11VH2 FV-11VHL2
FV-11VH2 FV-11VHL2
Thank you very much for having purchased our Ventilating Fan.
I
II
III
Maintenance (Cleaning) Maintenance (Replacement of lamp)
I
II
back cover back cover
Page 2
UNPACKING
Unpack and carefully remove unit from carton. Refer to the Supplied Accessories list to verify that all parts are present.
SUPPLIED ACCESSORIES
FOR MODEL FV-11VH2
FOR MODEL FV-11VH2
POURLE MODELE FV-11VHL2
POURLE MODELE FV-11VHL2
DESCRIPTION
The Panasonic ceiling mount ventilating fans uses a sirocco fan driven by a capacitor motor. The motor is designed to have an extended service life with reduced energy consumption. It also incorporates a thermal cut-off for safety. The grille covering the main body is a spring-loaded, quick-release type. A damper for preventing counterflow is provided. The blower uses a high-capacity sirocco fan developed to reduce the noise level. The heater for this unit is a 1400 W sheathed heater. A thermostat and thermal cut-off switch have been added for safety in case of an abnormal temperature rise in the heater. The lighting unit is an energy-saving, lighting device which uses two 18 W fluorescent lamps and produces almost the same illumination as a standard 100 W incandescent lamp (FV-11VHL2).
Page 3
DIMENSIONS
19 1/2 (497)
16 (407)
18 1/8 (460)
7 3/4 (196)
1 (25)
2 1/2 (62)
7 5/8 (195)
19 1/2 (497)
16 (407)
18 1/8 (460)
7 5/8 (195)
11 7/8 (301)
13 1/4 (337.8)
5 (128.7)
2 1/8 (54.8)
7 3/4 (196)
2 1/2 (62)
11 7/8 (301)
14 (357.8)
5 (128.7)
11 1/4 (285.5)
11 1/4 (285.5)
Ventilating unit
Page 4
SPECIFICATIONS
Exhaust & Circulation
29.5
GENERAL SAFETY INFORMATION
AC 120V, 60Hz.
1540
650
720
Vent (0.1" WG)
(cfm)
Noise
Vent
(sone)
0.6
0.7
15.6 (7.1)
17.8 (8.1)
8. Make sure that all duct work is properly vented.
9. DO NOT INSTALL THIS UNIT OVER A BATHTUB OR SHOWER ENCLOSURE.
10. This product (FV-11VHL2) has a fluorescent lamp that contains mercury. Disposal may be regulated in your community due to environmental considerations. For disposal or recycling information, please contact your local authorities or the Electronics Industries Alliance:http://www.eiae.org
Only for FV-11VHL2.
3. This product must be properly grounded.
Page 5
GENERAL SAFETY INFORMATION CONTINUED
WARNING:
To reduce the risk of fire, electric shock or injury to persons, observe the following:
Use this unit only in the manner intended by the manufacturer. If you have any questions, please contact
A.
the manufacturer. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable
B.
codes and standards, including fire-rated construction. Neither unauthorized modification, repair nor disassembly is allowed.
Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel
C.
buming equipment to prevent backdrafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating Refrigeration and Air Conditioning Engineers (ASHRAE) and the local code authorities.
D.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. Ducted fans must always be vented to the outdoors.
E.
Solid state controls may cause harmonic distortion which can cause motor humming noise. To reduce the
F.
risk of fire or electric shock, do not use this unit with any solid-state control device. Before servicing or cleaning unit, switch power off at service panel and lock panel cabinet to prevent
G.
power from being switched on accidentally. If the panel cabinet cannot be locked, securely fasten a clearly visible warning label to the service panel.
H.
Never place a switch where it can be reached from a tub or shower. Not to be installed in a ceiling thermally insulated to a value greater than R40. (This is required for
I.
installation in Canada only.) Use only on 20 ampere branch circuit.
J.
WIRING DIAGRAM
Circulating fan unit
Black Red
Motor(C)
White
Ventilating fan unit
Red White
Motor(V)
Black
Junction box
Green
Earth ground
Switch(not
Black
PCB
White
Capacitor
Black
White
ON
OFF
included)
Power Supply AC120V 60Hz
Thermal cut-off
Fuse
(230 F (110C))
(20A)
Heater (1400W)
Thermostat
oo
(140 F (60C))
Black
White
ON
OFF
Switch(not
Power Supply AC120V 60Hz
oo
included)
Circulating fan unit
Black Red
Motor(C)
White
Ventilating fan unit
Earth ground
Motor(V)
Junction box
Green
Red White
Black
Switch(not
Power Supply AC120V 60Hz
PCB
Capacitor
Black
ON
included)
Black
White
White
OFF
Fuse
Thermal cut-off
(20A)
(230 F (110C))
Heater (1400W)
Thermostat
oo
(140 F (60 C))
White
Black
ON
OFF
Power Supply AC120V 60Hz
Switch(not
oo
White
Black
ON
OFF
included)
Power Supply AC120V 60Hz
Lighting unit
Fluorescent lamp
Electronic
ballast
Fuse
White
Night lamp
Black
ON
OFF
Switch(not
Black
(3.15A)
included)
Page 6
INSTALLATION (JOIST MOUNTING- )
Illustrations in this manual common use the image of FV-11VHL2, and mark for FV-11VHL2 only, others are same for FV-11VH2.
1. Before installation, remove warning lable and the tape that is securing the adapter and the damper. (Fig.1)
Warning label
Tape
Fan body
Fig.1
2. Insert the suspension bracket into the fan body. (Select the suspension bracket as shown below.)
Suspension bracket
Fan body
Suspension bracket
Fan body
Suspension bracket
Suspension bracket
Suspension bracket
Fan body
Fig.2-1
Suspension bracket
Fig.2-2
Suspension bracket
Fig.2-3
Joists
16 inches and 19.2 inches horizontal joists
2 Screw (ST4.2X8)
Suspension bracket
Suspension bracket
(Fig.3)
16 inches and 19.2 inches horizontal joists refer to Fig.4-1, 19.2 inches vertical joists and 24 inches refer to Fig.4-2.
Joist
Screw (ST4.2X12)
2 Long screws (ST4.2X20)
Fan body
4 Long screws (ST4.2X20)
2 Long screws (ST4.2X20)
Screw (ST4.2X12)
Fig.4-1
Joist
Fig.4-2
Fig.3
Joist
Page 7
INSTALLATION (JOIST MOUNTING- ) CONTINUED
5. Remove the lighting cord out from hook (FV-11VHL2), then remove junction box plate and secure conduit or stress relief to wiring box knock-out hole.(Fig.5)
6. Refer to wiring diagram (Page.5) Follow all the local electrical safety codes. As well as the National Electrical Code (NEC). Using UL approved wire nuts, connect house power wires to ventilating fan wires (Fig.6): Black to black; white to white; green to green. Make sure all connections are fastened firmly after wiring is finished. Replace the junction box plate, and then replace lighting cord to hook. (Fig.5)
Lighting cord
Junction box plate
Black to black
White to white
Conduit
Joist
Hook
Black to black
White to white
Fan body
Screw driver
White to white
Black to black
Junction box plate
Screw
Fig.5
Green to green
Wire nut
Black to black
Junction box
Conduit
Fig.6
Circular duct
Duct tape or clamps
7. Install the circular duct (4 inches) to the adaptor and secure it with duct tape or clamps. (Fig.7)
8. Finish ceiling work. Ceiling hole should be aligned with the edge of the flange. (Fig.8)
9. Install the fluorescent lamps and then install the night lamp. (Fig.8)
10. Insert mounting springs into slots as shown and mount grille to fan body. (Fig.9)
Note:Do not mount grille and springs conversely. If the grille is mounted in the opposite direction, the grille can not be fitted to the ceiling, so then reverse the grille position and try to mount again.
(Fig.10)
4 Long screws (ST4.2X20)
17 3/8 (441)
Night lamp
Fluorescent lamp
Slot
Correct
Incorrect
For Model FV-11VHL2 For Model FV-11VH2
Mounting spring
Grille
Switch labels
12 5
/8 (319)
Switch labels
Fig.7
Fig.8
Fig.9
Fig.10
Page 8
INSTALLATION (BETWEEN JOIST MOUNTING)
Illustrations in this manual common use the image of FV-11VHL2.
1. Before installation, remove warning lable and the tape that is securing the adapter and the damper. (Fig.1)
Fig.11 (Select the suspension bracket according to spacing A as shown below.)
B
Suspension bracket
Fan body
Suspension bracket
Suspension bracket
Joists
Fig.11
Spacing A on center joists 16 inches
19.2 inches horizontal joists
19.2 inches vertical joists
13 1/4 ~ 15 1/2 (336~394) 14 3/4 ~ 16 3/4 (374~425) 16 1/2 ~ 18 3/4 (419~476)
B
Fig.12
Keep the distance C (1/2 inch, 12.7 mm) for the thickness of ceiling board.
Fan body
Suspension bracket
Adaptor
Junction box
C
Fig.12
Page 9
INSTALLATION (BETWEEN JOIST MOUNTING) CONTINUED
Fig.13, Fig.14
Joist
2 Long screws (ST4.2X20)
Fig.13
Fig.14
2-Screw (ST4.2X12)
4 Long screws (ST4.2X20)
6. Follow step 5 of installation (page 7) to complete the installation work.
INSTALLATION (WOODEN HEADER INSTALLATION)
1. Before installation, remove warning lable and the tape that is securing the adapter and the damper. (Fig.1)
(Fig.15, Fig.16)
Ceiling joist
11 3/8 (290)
Fan body
Joist
Fig.14
Header
Ceiling joist
19 7/8 (505)
Adaptor
4. Follow step 5 of installation (page 7) to complete the installation work.
Adaptor
Long screw (ST4.2X20)
Circular duct
Fig.15
Fig.16
Page 10
MAINTENANCE (CLEANING)
Slot
Mounting spring
Do not allow any water to get into the motor.
oo
60 C(140 F).
Fig.17
Fig.18
Fig.19
Gloves
Grille
Vacuum cleaner
1
1
2
Fig.17
Fig.18
Fig.19
5. Replace grille.
Fig.20
Fig.20
Page 11
MAINTENANCE (REPLACEMENT OF LAMP)
4. Be sure to remove the night lamp before removing fluorescent lamps.
(Fig.17 of page 10)
2. Remove the 4 W night lamp.(Fig.21)
3. Change the fluorescent lamps (FDS18E35/4, 18 W) (Fig.22) or the 4 W night lamp(Fig.21), replace the grille.
Night lamp
Fluorescent lamp
Fluorescent lamp
Fig.21
Fig.22
Page 12
PRACTICAL GUIDE TO INSTALLATION
Properly insulate the area around the fan to
Fig.23
Dryer-hood type vent with backdraft flap (s).
Caulk termination to duct. 2-3 ft straight run before elbow. In attic installation,
caulk box to drywall.
Short piece of flexible duct helps alignment and absorbs sound. Use clamps plus tape at all flex joints.
Foil tape tightly covers all metal duct joints (glue PVC joints).
Insulation
Fig.23
PANASONIC CONSUMER ELECTRONICS COMPANY
Division de Panasonic Corporation of North America, One Panasonic Way, Secaucus, NJ 07094 www.panasonic.com
PANASONIC CANADA INC.
5770 Ambler Drive, Mississauga, ON L4W 2T3 www.panasonic.ca
X0308-0 11VH24200